Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects. However, with the use of the jumbo cup, the center of the hip joint may become elevated relative to the primary acetabulum, and the diameter of the large cup is greater.
To study the height and the significance of the elevation of the hip joint center.
Eighty-eight patients matched the criteria for this condition and were included in the study. The center height of the hip joint was measured relative to the opposite normal hip joint. The diameter of the jumbo cup was measured and checked according to operation notes, and the diameter of the jumbo cup was measured with a prosthesis label. Then, the horizontal and vertical centers of rotation were measured on the surgical side and opposite side. The average center height of the hip joint on the renovated side and the opposite side and the position of the hip cup relative to the teardrop were compared using a paired t-test.
Radiometric analysis showed that the average hip joint center was elevated by 7.6 mm. The rotational center height delta of the renovated hip was 7.6 ± 5.6 mm, and there was an obvious difference between the two groups (P = 0.00). The difference in horizontal distance was 0.5 ± 5.1 mm (-11.5 -14.0 mm), and there was no obvious difference between the two groups (P = 0.38). According to the foreign standard, the rotational center height delta of the renovated hip was 7.5 ± 6.2 mm, and there was a significant difference between the two groups (P = 0.00). There was no obvious difference between the domestic and foreign standards (P > 0.05) between the two groups.
The application of the jumbo cup elevates the rotational center of the hip joint, but it is feasible and effective to use the jumbo cup.
Core Tip: In this study, we discuss the application of the jumbo cup via observing how high the elevation of the center of the hip joint is and its significance in imaging X-rays, and came to the conclusion: The application of the jumbo cup elevates the rotational center of the hip joint, but it is feasible and effective to use the jumbo cup.
- Citation: Peng YW, Shen JM, Zhang YC, Sun JY, Du YQ, Zhou YG. Jumbo cup in hip joint renovation may cause the center of rotation to increase. World J Clin Cases 2021; 9(22): 6300-6307
- URL: https://www.wjgnet.com/2307-8960/full/v9/i22/6300.htm
- DOI: https://dx.doi.org/10.12998/wjcc.v9.i22.6300
Boneless, cement-coated, giant cups (jumbo cups) and bolt-fixed revision total hip arthroplasty (THA) are valid technologies for curing most failed acetabular components with cavities or subtle segmental bone defects[1-3]. In revision THA, giant, hemispheric, boneless concrete acetabular cups (jumbo cups) generally have excellent outcomes in durability and versatility in dealing with cavities or subtle segmental bone defects[1-3]. Compared with other acetabulum renovations, there are several advantages to the use of jumbo cups. First, they offer a large contact area between the principal bone and the surface of porous implants, which is good for reliable biological fixation[4]. Moreover, this method can utilize hemispheric surgical techniques.
Reamer and screw fixation are similar applications in initial THA. However, many bone defects we often confront can be filled by transplanting large acetabular cups and spongy bone, and we sometimes do not need large amounts of allogeneic bone transplantation and reinforcer. A giant cup (jumbo cup) provides a substitute method for filling bone defects and acetabular cavities, which involves the placing of a cup to fill defects in the acetabulum (high hip center) or using a hunch in the anatomical acetabulum[5].
However, to suit implants that are usually larger than the primary acetabulum, the jumbo cup technique requires reaming and preparation of the surface of the ace
Leg length discrepancy is not uncommon after revision THA. However, unlike primary THA, limb shortening is more common than lengthening during revision THA, which can be related to cup positioning[9].
In the present study, there is clinical verification of the computer simulation research. We discuss the application of the jumbo cup through observations based on the height of the elevation of the center of the hip joint and its significance (about limb shortening or not) in imaging X-rays.
Inclusion criteria: One hip joint was normal, another underwent revision hip arthroplasty, and the diameter of the jumbo cup was no less than 64 mm in males and 60 mm in females and had no heel or reinforcer.
Exclusion criteria: (1) The diameter of the jumbo cup was less than 64 mm in males and 60 mm in females; (2) The other hip joint had abnormalities, such as avascular necrosis, or integration; (3) Revision of total hip arthroplasty; (4) The use of a heel or reinforcer; and (5) A jumbo cup was placed with a high center of rotation on the renovated side.
Eighty-eight patients met the study criteria: 44 were males and 44 were females. The average age was 61 ± 11 years (range from 32-85 years), the average height was 165.1 ± 7.8 cm (range from 146-182 cm), and the average weight was 70.8 ± 13.5 kg (range from 43 -100 kg). We analyzed the images with Medcare software to measure the height and horizontal distance of the bilateral hip joint rotational center, including the abduction angle by utilizing this software.
Prostheses were mainly from Pinnacle, with Gription Acetabular Cups from DePuy Orthopedics, Inc., acetabular cups from Zimmer Inc., America, and Cementless Hip Prostheses (CombiCups PF and TOPII) from Waldemar Link.
All imaging measurements were performed by one experimenter. All imaging was conducted 1 wk after the operation (Figure 1), and measurements were taken with orthotopic X-ray of the pelvis using MedCare software. The main results were compared with those of the opposite side hip joint to assess vertical and horizontal differences between the hip joint centers. To identify the location of the rotational center, we drew a circle in the jumbo and opposite side hip joints, and these circles were aligned with the edge of the acetabulum. The center of this circle was assumed to be the hip joint center (Figure 2). The center height of the hip joint was estimated by measuring the height of the vertical line from the lower edge of the acetabular tear to the center of the hip joint. We could carry out measurements in the hip joint of the jumbo cup side and opposite side, and the difference in the vertical position of the center of the two hips was seen as the measurement of the upward movement of the center of the hip at the jumbo cup side. The lower edge of the acetabular teardrop was used as a reference point for measurement in that teardrop as an independent anatomical structure whose vertical position is not substantially affected by the rotation of the pelvis.
To determine how much of the vertical change in the center of the revision hip was due to the placement of the prosthesis above the teardrop line, the straight-line distance from the jumbo cup to the teardrop line was measured (Figure 3). This was deemed the elevation of the center of the hip join for the placement of the cup above the site originally planned. If the lower lip of the giant cup was under the teardrop line, then the cup was given a negative number. Since the position of the lower edge of the cup body is also affected by the abduction angle, the normal position of the cup should be at a 45° abduction angle.
The diameter of the jumbo cup was measured and checked according to the operation notes and using a prosthesis label. Then, the horizontal and vertical centers of rotation (H-COR and V-COR) were measured on the surgical side and opposite side. The average center height of the hip joint on the renovated side and the opposite side and the position of the hip cup relative to the teardrop were compared using a paired t-test.
The X-ray imaging analysis showed that our jumbo cup technique elevated the center of the hip joint. The average hip joint rotational center height of the jumbo cup was 23.0 ± 6.1 mm (males = 22.1 mm, females = 24.0 mm). The average hip joint opposite side rotational center height was 15.4 ± 3.4 mm (males = 15.3 mm, females = 15.5 mm). This approach produced an average hip joint rotational center height difference of 7.6 mm. The horizontal distance of the jumbo cup was 36.4 ± 4.6 mm (25.3-48.6 mm). The horizontal distance on the opposite side was 35.9 ± 4.4 mm (28.0-47.6 mm). The difference in horizontal distance in the renovated hip joint was 0.5 ± 5.1 mm (-11.5-14.0 mm). The average abduction angle of the horizontal distance in the renovated hip joint was 40.6° ± 6.9° (28.1°-63.0°, Table 1).
Maximum values | Minimum values | Mean values | |
Diameter of acetabular cup (mm) | 60.00 | 72.00 | 65.0000 |
Height of rotating center (mm) | 5.60 | 39.80 | 23.0273 |
Height of contralateral rotating center (mm) | 5.60 | 24.70 | 15.4011 |
Differences (mm) | -6.60 | 19.50 | 7.6261 |
Horizontal distance of jumbo cup (mm) | 25.30 | 48.60 | 36.4398 |
Contralateral horizontal distance (mm) | 28.00 | 47.60 | 35.9398 |
Differences (mm) | -11.50 | 14.00 | 0.5000 |
Abduction angle (°) | 28.10 | 63.00 | 40.6011 |
The results of the paired t test showed that the height difference of the rotational center of renovated hip joints was 7.6 ± 5.6 mm, and that there was an obvious difference between the two groups (P = 0.00); however, the difference in horizontal distance was 0.5 ± 5.1 mm (-11.5-14.0 mm), and there was no obvious difference between the two groups (P = 0.38, Table 2).
Mean values | SD | t | Degree of freedom | Significance (two tail) | |
Differences of vertical height | 7.62614 | 5.58741 | 12.804 | 87 | 0.000 |
Differences of horizontal height | 0.50000 | 5.07586 | 0.924 | 87 | 0.358 |
According to European and American definitions of the jumbo cup criteria, we performed the statistical analysis again for patients who met the criteria, which resulted in a total of 88 patients (88 hips) in this study; a total of 54 patients (54 cases; 25 males and 29 females) met the criteria for reanalysis. The average hip joint rotational center height of the jumbo cup was 23.2 ± 6.6 mm (males = 21.0 mm, females = 25.0 mm). The average hip joint rotational center height of the opposite side was 15.7 ± 3.4 mm (males = 15.7 mm, females = 15.7 mm). The results of this analysis showed an average hip joint rotational center height difference, and we found that the difference between the two groups was 7.5 ± 6.2 mm (-6.6-19.5 mm). The horizontal distance of the jumbo cup was 36.8 ± 4.5 mm (26.4-48.6 mm), and the horizontal distance on the opposite side was 36.0 ± 4.0 mm (28.1-46.3 mm). The difference in horizontal distance in the renovated hip joint was 0.8 ± 5.0 mm (-11.5-13.7 mm). The average abduction angle of the horizontal distance in the renovated hip joint was 41.2° ± 7.0° (28.1°-61.5°). The height difference in the rotational center of the renovated hip joint was 7.5 ± 6.2 mm, and there was an obvious difference between the two groups (paired t test P = 0.00); however, the difference in horizontal distance was 0.8 ± 5.0 mm (-11.5-13.7 mm), and there was no obvious difference between the two groups (P = 0.26, Table 3).
Mean values | SD | t | Degree of freedom | Significance (two tail) | |
Differences of vertical height | 7.50926 | 6.24353 | 8.838 | 53 | 0.000 |
Differences of horizontal height | 0.76667 | 4.96030 | 1.136 | 53 | 0.261 |
There were no significant differences between the domestic and foreign standards (Table 4).
The test of variance equivalence | Mean isotropic t-test | ||||
F | Significance | t | Degree of freedom | Significance (two tail) | |
Differences of height | |||||
Assumed equivariance | 988 | 0.322 | 0.116 | 140 | 0.908 |
No assumed equivariance | 0.113 | 102.772 | 0.911 | ||
Differences of horizon | |||||
Assumed equivariance | 0 | 0.997 | -0.307 | 140 | 0.76 |
No assumed equivariance | -0.308 | 114.256 | 0.758 |
Compared with other methods of acetabulum renovation, there are many advantages in applying the jumbo cup such as a large contact area between the principal bone and the surface of porous implants, which is good for reliable biological fixation. The jumbo cup also permits relatively direct and repeatable hemispheric surgical tech
A vertical hip center shift during revision THA may result in leg length discrepancies, altered hip biomechanics, and soft tissue laxity. A retrospective study involving 79 THA revisions by Dou et al[9] showed that acetabular cup placement contributes to hip center elevation and leg length discrepancies after revision THA. In addition to its role in leg length changes, an elevated hip center can result in suboptimum bio
Despite the elevation of the rotational center of the hip joint, it was not sufficient to match the definition of a high rotational center, the elevation was a minimal. Although Nwankwo et al[11] and others found that the average rotational center rose 11 mm in their study, the rise in the average rotational center was only 7.5 mm in our study. These values represent excellent outcomes in numerous research reports regarding the placement of jumbo cups with high rotational centers in treating lateral acetabular defects[12-15]. Kelley[16]’s study of 23 jumbo cups placed with a high rotational center did not show loosening at an average of 35 mo of follow-up. In the longer series reported by Dearborn et al[17], there was only a 6% rate of mechanical loosening with a mean follow-up of 10.4 years. Utilizing a high center of the hip joint has a negative influence on the function of the abductor muscles, and differences in mean limb length were reduced after femoral reconstruction. This finding suggests that increasing the length of the femoral head may help to avoid limb shortening when using jumbo cup technology in revision THA. Some authors have reported encouraging clinical results with jumbo cups[10,18-21].
There are some limitations in our research design. There were deviations in the measurements from radiographic plain films. Measurements were made from specific anatomical marks used by an observer in every patient to reduce measurement errors. However, we were unable to identify accurately the reliability of the measurement techniques because there were no repeatability tests of intra-observer and inter-observer variability included in the study. We also did not utilize an established taxonomy to quantify acetabular lesions in this series of patients.
Based on our findings, we suggest that applying a jumbo cup in revision THA increases the height of the rotational center of the hip joint, but it is feasible and effective to utilize jumbo cups in revision THA with a limited height.
Utilizing the large jumbo cup in revision total hip arthroplasty (THA) is an effective approach to cure many lacunar and segmental peripheral bone defects. However, with the use of the jumbo cup, the center of the hip joint may become elevated relative to the primary acetabulum, and the diameter of the large cup is greater.
In order to explore the height and significance of X-rays used to study the height of the hip joint center, as a guide for clinical work.
X-rays were applied to study the height and the significance of the elevation of the hip joint center.
Eighty-eight patients were included in the study. The center height of the hip joint was measured relative to the opposite normal hip joint. The diameter of the jumbo cup was measured and checked according to operation notes, and the diameter of the jumbo cup was measured with a prosthesis label.
Radiometric analysis showed that the average hip joint center was elevated by 7.6 mm. The rotational center height delta of the renovated hip was 7.6 ± 5.6 mm, and there was an obvious difference between the two groups. For the difference in horizontal distance, there was no obvious difference between the two groups. The rotational center height delta of the renovated hip was 7.5 ± 6.2 mm, and there was a significant difference between the two groups.
The application of the jumbo cup elevates the rotational center of the hip joint, but it is feasible and effective to use the jumbo cup.
Applying a jumbo cup in revision THA increases the height of the rotational center of the hip joint, but it is feasible and effective to utilize jumbo cups in revision THA with a limited height.
Manuscript source: Unsolicited manuscript
Specialty type: Orthopedics
Country/Territory of origin: China
Peer-review report’s scientific quality classification
Grade A (Excellent): 0
Grade B (Very good): 0
Grade C (Good): C
Grade D (Fair): 0
Grade E (Poor): 0
P-Reviewer: Goudeau YR S-Editor: Wang JL L-Editor: Filipodia P-Editor: Yuan YY
1. | Dearborn JT, Harris WH. Acetabular revision arthroplasty using so-called jumbo cementless components: an average 7-year follow-up study. J Arthroplasty. 2000;15:8-15. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 98] [Cited by in F6Publishing: 104] [Article Influence: 4.3] [Reference Citation Analysis (0)] |
2. | Patel JV, Masonis JL, Bourne RB, Rorabeck CH. The fate of cementless jumbo cups in revision hip arthroplasty. J Arthroplasty. 2003;18:129-133. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 69] [Cited by in F6Publishing: 60] [Article Influence: 2.9] [Reference Citation Analysis (0)] |
3. | Whaley AL, Berry DJ, Harmsen WS. Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty. J Bone Joint Surg Am. 2001;83:1352-1357. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 178] [Cited by in F6Publishing: 149] [Article Influence: 6.5] [Reference Citation Analysis (0)] |
4. | Jasty M. Jumbo cups and morsalized graft. Orthop Clin North Am. 1998;29:249-254. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 80] [Cited by in F6Publishing: 77] [Article Influence: 3.0] [Reference Citation Analysis (0)] |
5. | Brooks PJ. The jumbo cup: the 95% solution. Orthopedics. 2008;31:913, 915. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 4] [Cited by in F6Publishing: 5] [Article Influence: 0.3] [Reference Citation Analysis (0)] |
6. | Vasavada AN, Delp SL, Maloney WJ, Schurman DJ, Zajac FE. Compensating for changes in muscle length in total hip arthroplasty. Effects on the moment generating capacity of the muscles. Clin Orthop Relat Res. 1994;121-133. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 13] [Cited by in F6Publishing: 13] [Article Influence: 0.4] [Reference Citation Analysis (0)] |
7. | Tanzer M. Role and results of the high hip center. Orthop Clin North Am. 1998;29:241-247. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 27] [Cited by in F6Publishing: 27] [Article Influence: 1.0] [Reference Citation Analysis (0)] |
8. | Delp SL, Wixson RL, Komattu AV, Kocmond JH. How superior placement of the joint center in hip arthroplasty affects the abductor muscles. Clin Orthop Relat Res. 1996;137-146. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 122] [Cited by in F6Publishing: 126] [Article Influence: 4.5] [Reference Citation Analysis (0)] |
9. | Dou Y, Zhou Y, Tang Q, Yang D, Liu J. Leg-length discrepancy after revision hip arthroplasty: are modular stems superior? J Arthroplasty. 2013;28:676-679. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 15] [Cited by in F6Publishing: 15] [Article Influence: 1.4] [Reference Citation Analysis (0)] |
10. | Lachiewicz PF, Soileau ES. Fixation, survival, and dislocation of jumbo acetabular components in revision hip arthroplasty. J Bone Joint Surg Am. 2013;95:543-548. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 36] [Cited by in F6Publishing: 41] [Article Influence: 3.7] [Reference Citation Analysis (0)] |
11. | Nwankwo CD, Ries MD. Do jumbo cups cause hip center elevation in revision THA? Clin Orthop Relat Res. 2014;472:2793-2798. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 22] [Cited by in F6Publishing: 26] [Article Influence: 2.6] [Reference Citation Analysis (0)] |
12. | Shen J, Sun J, Ma H, Du Y, Li T, Zhou Y. High Hip Center Technique in Total Hip Arthroplasty for Crowe Type II-III Developmental Dysplasia: Results of Midterm Follow-up. Orthop Surg. 2020;12:1245-1252. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 9] [Cited by in F6Publishing: 16] [Article Influence: 4.0] [Reference Citation Analysis (0)] |
13. | Montalti M, Castagnini F, Giardina F, Tassinari E, Biondi F, Toni A. Cementless Total Hip Arthroplasty in Crowe III and IV Dysplasia: High Hip Center and Modular Necks. J Arthroplasty. 2018;33:1813-1819. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 47] [Cited by in F6Publishing: 47] [Article Influence: 7.8] [Reference Citation Analysis (0)] |
14. | Galea VP, Laaksonen I, Donahue GS, Fukui K, Kaneuji A, Malchau H, Bragdon C. Developmental Dysplasia Treated With Cementless Total Hip Arthroplasty Utilizing High Hip Center Reconstruction: A Minimum 13-Year Follow-up Study. J Arthroplasty. 2018;33:2899-2905. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 20] [Cited by in F6Publishing: 20] [Article Influence: 3.3] [Reference Citation Analysis (0)] |
15. | Chen M, Luo ZL, Wu KR, Zhang XQ, Ling XD, Shang XF. Cementless Total Hip Arthroplasty With a High Hip Center for Hartofilakidis Type B Developmental Dysplasia of the Hip: Results of Midterm Follow-Up. J Arthroplasty. 2016;31:1027-1034. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 27] [Cited by in F6Publishing: 28] [Article Influence: 3.5] [Reference Citation Analysis (0)] |
16. | Kelley SS. High hip center in revision arthroplasty. J Arthroplasty. 1994;9:503-510. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 98] [Cited by in F6Publishing: 83] [Article Influence: 2.8] [Reference Citation Analysis (0)] |
17. | Dearborn JT, Harris WH. High placement of an acetabular component inserted without cement in a revision total hip arthroplasty. Results after a mean of ten years. J Bone Joint Surg Am. 1999;81:469-480. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 119] [Cited by in F6Publishing: 113] [Article Influence: 4.5] [Reference Citation Analysis (0)] |
18. | Zhang J, Huang Y, Zhou B, Zhou Y. Mid-Term Follow-Up of Acetabular Revision Arthroplasty Using Jumbo Cups. Orthop Surg. 2019;11:811-818. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 5] [Cited by in F6Publishing: 6] [Article Influence: 1.2] [Reference Citation Analysis (0)] |
19. | von Roth P, Abdel MP, Harmsen WS, Berry DJ. Uncemented jumbo cups for revision total hip arthroplasty: a concise follow-up, at a mean of twenty years, of a previous report. J Bone Joint Surg Am. 2015;97:284-287. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 46] [Cited by in F6Publishing: 43] [Article Influence: 4.8] [Reference Citation Analysis (0)] |
20. | Moon JK, Ryu J, Kim Y, Yang JH, Hwang KT, Kim YH. Acetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up study. Arch Orthop Trauma Surg. 2019;139:1149-1160. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 8] [Cited by in F6Publishing: 9] [Article Influence: 1.8] [Reference Citation Analysis (0)] |
21. | Gustke KA, Levering MF, Miranda MA. Use of jumbo cups for revision of acetabulae with large bony defects. J Arthroplasty. 2014;29:199-203. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 44] [Cited by in F6Publishing: 48] [Article Influence: 4.8] [Reference Citation Analysis (0)] |