Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects. However, with the use of the jumbo cup, the center of the hip joint may become elevated relative to the primary acetabulum, and the diameter of the large cup is greater.
To study the height and the significance of the elevation of the hip joint center.
Eighty-eight patients matched the criteria for this condition and were included in the study. The center height of the hip joint was measured relative to the opposite normal hip joint. The diameter of the jumbo cup was measured and checked according to operation notes, and the diameter of the jumbo cup was measured with a prosthesis label. Then, the horizontal and vertical centers of rotation were measured on the surgical side and opposite side. The average center height of the hip joint on the renovated side and the opposite side and the position of the hip cup relative to the teardrop were compared using a paired t-test.
Radiometric analysis showed that the average hip joint center was elevated by 7.6 mm. The rotational center height delta of the renovated hip was 7.6 ± 5.6 mm, and there was an obvious difference between the two groups (P = 0.00). The difference in horizontal distance was 0.5 ± 5.1 mm (-11.5 -14.0 mm), and there was no obvious difference between the two groups (P = 0.38). According to the foreign standard, the rotational center height delta of the renovated hip was 7.5 ± 6.2 mm, and there was a significant difference between the two groups (P = 0.00). There was no obvious difference between the domestic and foreign standards (P > 0.05) between the two groups.
The application of the jumbo cup elevates the rotational center of the hip joint, but it is feasible and effective to use the jumbo cup.
Core Tip: In this study, we discuss the application of the jumbo cup via observing how high the elevation of the center of the hip joint is and its significance in imaging X-rays, and came to the conclusion: The application of the jumbo cup elevates the rotational center of the hip joint, but it is feasible and effective to use the jumbo cup.