Table 1 Basic demographics and laboratory characteristics of the study population and factors associated with the liver stiffness measurements measured by shear wave elastography and transient elastography in univariate and multivariate linear regression analyses
Variables | SWE (P value) | TE (P value) | ||||
Univariate analysis | Multivariate analysis | Univariate analysis | Multivariate analysis | |||
Gender (M/F) | 41 (76%)/13 (24%) | 0.217 | 0.072 | |||
Age (yr) | 36.7 ± 9.96, 19.0-61.01 | 0.823 | 0.509 | |||
BMI (kg/m2) | 23.9 (21.9-25.0) (16.4-30.3)2 | 0.818 | 0.232 | |||
HAI | HAI 0–4 | 11 (20.4%) | 0.659 | 0.184 | ||
HAI 5–6 | 18 (33.3%) | |||||
HAI 7-12 | 25 (46.3%) | |||||
Fibrosis | F0 | 3 (5.6%) | 0.000 | 0.000 | 0.000 | 0.037 |
F1 | 4 (7.4%) | |||||
F2 | 20 (37.0%) | |||||
F3 | 22 (40.7%) | |||||
≥F4 | 5 (9.3%) | |||||
WBC (109/L) | 5.5 (4.3-6.6) (1.7-9.4)2 | 0.078 | 0.173 | |||
NEU (109/L) | 3.1 (2.3-3.9) (1.0-7.5)2 | 0.490 | 0.500 | |||
HB (109/L) | 151.0 (139-165) (100.0-180.0)2 | 0.053 | 0.184 | |||
PLT (109/L) | 166.5 (128.3-219.8) (65.0-327.0)2 | 0.088 | 0.006 | 0.089 | ||
ALT (IU/L) | 50.4 (28.8-129.2) (12.5-402.9)2 | 0.737 | 0.059 | |||
AST (IU/L) | 38.9 (26.5-67.0) (16.1-179.2)2 | 0.338 | 0.531 | |||
TBIL (μmol/L) | 14.5 (11.9-20.7) (7.2-45.0)2 | 0.046 | 0.512 | 0.000 | 0.013 | |
CHE (IU/L) | 7635 (6335-9076) (2138-16444)2 | 0.925 | 0.191 | |||
SCR (μmol/L) | 70.1 (55.7-81.5) (40.0-120.2)2 | 0.719 | 0.916 | |||
PT (s) | 11 (10.5-11.8) (9.2-13.7)2 | 0.879 | 0.125 | |||
APTT (s) | 14.5 (31.9-36.3) (0.9-43.1)2 | 0.754 | 0.587 | |||
PTA (%) | 101.0 (90.0-111.5) (69.0-122.0)2 | 0.612 | 0.091 | |||
INR | 1.03 (0.9-1.1) (0.9-1.6)2 | 0.106 | 0.475 | |||
HBsAb (-/+) | 46 (85%)/7 (13%) | 0.270 | 0.167 | |||
HBeAg (-/+) | 21 (39%)/33 (61%) | 0.772 | 0.405 | |||
HBeAb (-/+) | 27 (50%)/27 (50%) | 0.539 | 0.523 | |||
Log10HBV DNA | 4.8 (2.7-6.3) (1.3-8.4)2 | 0.045 | 0.148 | 0.711 |
Table 2 Performance characteristics of shear wave elastography and transient elastography for staging liver fibrosis in chronic hepatitis B patients
Parameters | AUROC | Cutoff Value (kPa) | Sensitivity, % | Specificity, % | PPV, % | NPV, % | LR+ | LR- |
SWE | 0.786 | 9.05 | 77.78 | 77.78 | 77.78 | 77.78 | 3.50 | 0.29 |
TE | 0.714 | 8.15 | 59.26 | 66.67 | 64.00 | 62.07 | 1.78 | 0.61 |
FIB-4 | 0.551 | 0.91 | 74.07 | 44.44 | 57.14 | 63.16 | 1.33 | 0.58 |
APRI | 0.556 | 0.37 | 81.48 | 44.44 | 59.46 | 70.59 | 1.47 | 0.42 |
- Citation: Yao TT, Pan J, Qian JD, Cheng H, Wang Y, Wang GQ. Shear wave elastography may be sensitive and more precise than transient elastography in predicting significant fibrosis. World J Clin Cases 2020; 8(17): 3730-3742
- URL: https://www.wjgnet.com/2307-8960/full/v8/i17/3730.htm
- DOI: https://dx.doi.org/10.12998/wjcc.v8.i17.3730