Retrospective Study
Copyright ©The Author(s) 2024. Published by Baishideng Publishing Group Inc. All rights reserved.
World J Clin Cases. Jun 16, 2024; 12(17): 2989-2994
Published online Jun 16, 2024. doi: 10.12998/wjcc.v12.i17.2989
Application of multi-planar reconstruction technique in endovascular repair of aortic dissection
Guo-Jie Li, Ming-Xian Zhao
Guo-Jie Li, Ming-Xian Zhao, Department of Vascular Surgery, Qinghai Province Cardiovascular and Cerebrovascular Disease Specialist Hospital, Xining 810000, Qinghai Province, China
Author contributions: Li GJ collected the data and wrote the manuscript; Zhao MX performed the statistical analysis; and both authors read and approved the final manuscript.
Supported by Qinghai Province Medical and Health Technology Project, No. 2021-wjzdx-88.
Institutional review board statement: This study was approved by the Medical Ethics Committee of Qinghai Province Cardiovascular and Cerebrovascular Disease Specialist Hospital.
Informed consent statement: All study participants provided written informed consent before enrollment.
Conflict-of-interest statement: We have no financial relationships or conflicts of interest to disclose.
Data sharing statement: No additional data are available.
Open-Access: This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/licenses/by-nc/4.0/
Corresponding author: Ming-Xian Zhao, MBChB, Associate Chief Physician, Department of Vascular Surgery, Qinghai Province Cardiovascular and Cerebrovascular Disease Specialist Hospital, No. 7 Zhuanchang Road, Chengzhong District, Xining 810000, Qinghai Province, China. mingxian_9zhao@163.com
Received: February 19, 2024
Revised: March 21, 2024
Accepted: April 15, 2024
Published online: June 16, 2024
Processing time: 106 Days and 7.8 Hours
Core Tip

Core Tip: Stent placement for the endovascular repair of aortic dissection is performed once and cannot be adjusted repeatedly during surgery. Therefore, it is necessary to fully understand the branch status, position, angle, and other information of aortic arch dissection before the operation. Tulti planar reconstruction is a technique that can achieve omnidirectional rotational imaging by adjusting the slice thickness and can help doctors observe the details of blood vessels.