Successful leadless pacemaker implantation in a patient with dextroversion of the heart: A case report
Na Li, Hai-Xiong Wang, Yue-Hui Sun, Yan Shu, Department of Cardiology, Shanxi Cardiovascular Hospital, Taiyuan 030000, Shanxi Province, China
Co-first authors: Na Li and Yue-Hui Sun.
Co-corresponding authors: Yan Shu and Hai-Xiong Wang.
Author contributions: Shu Y and Wang HX made an equal contribution to this work, and were responsible for the design of the research study; Li N and Sun YH analyzed the data and wrote the manuscript; Every author has reviewed and given their approval to the final draft of the manuscript.
Supported by Shanxi Provincial Health Commission “Four batch” Science and Technology Innovation Project of Medical Development , No. 2021XM45 ; Natural Science Foundation of Shanxi Province , No. 20210302123346 ; Scientific Research Incentive Fund of Shanxi Cardiovascular Hospital , No. XYS20220205 ; and Traditional Chinese Medicine research project of Shanxi Province , No. 2023ZYYA028 .
Informed consent statement: All study participants, or their legal guardian, provided informed written consent prior to study enrollment.
Conflict-of-interest statement: All the authors have no conflicts of interest to declare.
CARE Checklist (2016) statement: The authors have read the CARE Checklist (2016), and the manuscript was prepared and revised according to the CARE Checklist (2016).
Open-Access: This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/
Corresponding author: Yan Shu, Doctor, PhD, Chief Pharmacist, Department of Cardiology, Shanxi Cardiovascular Hospital, No. 18 Yifen Street, Taiyuan 030000, Shanxi Province, China. shuyan20230919@163.com
Received: September 19, 2023
Peer-review started: September 19, 2023
First decision: October 17, 2023
Revised: October 22, 2023
Accepted: November 14, 2023
Article in press: November 14, 2023
Published online: November 26, 2023
Processing time: 66 Days and 1.3 Hours
Peer-review started: September 19, 2023
First decision: October 17, 2023
Revised: October 22, 2023
Accepted: November 14, 2023
Article in press: November 14, 2023
Published online: November 26, 2023
Processing time: 66 Days and 1.3 Hours
Core Tip
Core Tip: Dextroversion can be even more challenging given the distortion of normal anatomical relationships and the uncertainty of the accurate location and borders of the cardiac structures caused by the shift and rotation effected by the pathologic process. We present a complicated but successful case of implantation of a leadless pacemaker in a patient with cardiac dextroversion.