X-ray detection of ingested non-metallic foreign bodies
Miguel Saps, John M Rosen, Jacob Ecanow
Miguel Saps, John M Rosen, Division of Pediatric Gastroenterology, Hepatology and Nutrition, Ann and Robert H Lurie Children’s Hospital of Chicago, Northwestern Feinberg School of Medicine, Chicago, IL 60611-2605, United States
Jacob Ecanow, Department of Radiology, Northshore University Health System, University of Chicago Pritzker School of Medicine, Chicago, IL 60611-2605, United States
Author contributions: Saps M and Ecanow J designed the study; Ecanow J carried out the study; Saps M, Rosen JM and Ecanow J interpreted study results; Rosen JM drafted the initial manuscript; all authors revised the article critically for important intellectual content, and gave final approval of the version to be published.
Correspondence to: Miguel Saps, MD, Associate Professor of Pediatrics, Division of Pediatric Gastroenterology, Hepatology, and Nutrition, Ann and Robert H Lurie Children’s Hospital of Chicago, Northwestern Feinberg School of Medicine, 225 E. Chicago Avenue, Box 65, Chicago, IL 60611-2605, United States. msaps@luriechildrens.org
Telephone: +1-31-22274200 Fax: +1-31-22279645
Received: December 17, 2013
Revised: February 21, 2014
Accepted: March 13, 2014
Published online: May 8, 2014
Processing time: 154 Days and 9.8 Hours
Abstract

AIM: To determine the utility of X-ray in identifying non-metallic foreign body (FB) and assess inter-radiologist agreement in identifying non-metal FB.

METHODS: Focus groups of nurses, fellows, and attending physicians were conducted to determine commonly ingested objects suitable for inclusion. Twelve potentially ingested objects (clay, plastic bead, crayon, plastic ring, plastic army figure, glass bead, paperclip, drywall anchor, eraser, Lego™, plastic triangle toy, and barrette) were embedded in a gelatin slab placed on top of a water-equivalent phantom to simulate density of a child’s abdomen. The items were selected due to wide availability and appropriate size for accidental pediatric ingestion. Plain radiography of the embedded FBs was obtained. Five experienced radiologists blinded to number and types of objects were asked to identify the FBs. The radiologist was first asked to count the number of items that were visible then to identify the shape of each item and describe it to a study investigator who recorded all responses. Overall inter-rater reliability was analyzed using percent agreement and κ coefficient. We calculated P value to assess the probability of error involved in accepting the κ value.

RESULTS: Fourteen objects were radiographed including 12 original objects and 2 duplicates. The model’s validity was supported by clear identification of a radiolucent paperclip as a positive control, and lack of identification of plastic beads (negative control) despite repeated inclusion. Each radiologist identified 7-9 of the 14 objects (mean 8, 67%). Six unique objects (50%) were identified by all radiologists and four unique objects (33%) were not identified by any radiologist (plastic bead, Lego™, plastic triangle toy, and barrette). Identification of objects that were not present, false-positives, occurred 1-2 times per radiologist (mean 1.4). An additional 17% of unique objects were identified by less than half of the radiologists. Agreement between radiologists was considered almost perfect (kappa 0.86 ± 0.08, P < 0.0001).

CONCLUSION: We demonstrate potential non-identification of commonly ingested non-metal FBs in children. A registry for radiographic visibility of ingested objects should be created to improve clinical decision-making.

Keywords: Foreign bodies; X-rays; Pediatrics; Radiographic phantom; Diagnostic imaging

Core tip: Foreign body (FB) ingestion is very common in children and results in numerous visits for acute medical evaluation. X-ray identification of FB location and retention is used to guide management decisions including performance of additional imaging studies or FB retrieval. We investigated whether non-metal FB were visible on X-ray using a radiographic phantom. Our results show that expert radiologists are potentially unable to identify ingested non-metal foreign bodies. Creation of a database to catalogue X-ray characteristics of ingested non-metal objects would enable clinicians to improve quality of care by reduction of false-negative tests and prevention of unnecessary procedures.