Caruso D, De Santis D, Tremamunno G, Santangeli C, Polidori T, Bona GG, Zerunian M, Del Gaudio A, Pugliese L, Laghi A. Deep learning reconstruction algorithm and high-concentration contrast medium: feasibility of a double-low protocol in coronary computed tomography angiography. Eur Radiol 2025; 35:2213-2221. [PMID: 39299952 PMCID: PMC11913928 DOI: 10.1007/s00330-024-11059-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 06/28/2024] [Accepted: 08/16/2024] [Indexed: 09/22/2024]
Abstract
OBJECTIVE To evaluate radiation dose and image quality of a double-low CCTA protocol reconstructed utilizing high-strength deep learning image reconstructions (DLIR-H) compared to standard adaptive statistical iterative reconstruction (ASiR-V) protocol in non-obese patients. MATERIALS AND METHODS From June to October 2022, consecutive patients, undergoing clinically indicated CCTA, with BMI < 30 kg/m2 were prospectively included and randomly assigned into three groups: group A (100 kVp, ASiR-V 50%, iodine delivery rate [IDR] = 1.8 g/s), group B (80 kVp, DLIR-H, IDR = 1.4 g/s), and group C (80 kVp, DLIR-H, IDR = 1.2 g/s). High-concentration contrast medium was administered. Image quality analysis was evaluated by two radiologists. Radiation and contrast dose, and objective and subjective image quality were compared across the three groups. RESULTS The final population consisted of 255 patients (64 ± 10 years, 161 men), 85 per group. Group B yielded 42% radiation dose reduction (2.36 ± 0.9 mSv) compared to group A (4.07 ± 1.2 mSv; p < 0.001) and achieved a higher signal-to-noise ratio (30.5 ± 11.5), contrast-to-noise-ratio (27.8 ± 11), and subjective image quality (Likert scale score: 4, interquartile range: 3-4) compared to group A and group C (all p ≤ 0.001). Contrast medium dose in group C (44.8 ± 4.4 mL) was lower than group A (57.7 ± 6.2 mL) and B (50.4 ± 4.3 mL), all the comparisons were statistically different (all p < 0.001). CONCLUSION DLIR-H combined with 80-kVp CCTA with an IDR 1.4 significantly reduces radiation and contrast medium exposure while improving image quality compared to conventional 100-kVp with 1.8 IDR protocol in non-obese patients. CLINICAL RELEVANCE STATEMENT Low radiation and low contrast medium dose coronary CT angiography protocol is feasible with high-strength deep learning reconstruction and high-concentration contrast medium without compromising image quality. KEY POINTS Minimizing the radiation and contrast medium dose while maintaining CT image quality is highly desirable. High-strength deep learning iterative reconstruction protocol yielded 42% radiation dose reduction compared to conventional protocol. "Double-low" coronary CTA is feasible with high-strength deep learning reconstruction without compromising image quality in non-obese patients.
Collapse
Affiliation(s)
- Damiano Caruso
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Domenico De Santis
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Giuseppe Tremamunno
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Curzio Santangeli
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Tiziano Polidori
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Giovanna G Bona
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Marta Zerunian
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Antonella Del Gaudio
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Luca Pugliese
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy
| | - Andrea Laghi
- Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome, Rome, Italy.
| |
Collapse
|
2
|
Andreini D, Belmonte M, Penicka M, Van Hoe L, Mileva N, Paolisso P, Nagumo S, Nørgaard BL, Ko B, Otake H, Koo BK, Jensen JM, Mizukami T, Munhoz D, Updegrove A, Taylor C, Leipsic J, Sonck J, De Bruyne B, Collet C. Impact of coronary CT image quality on the accuracy of the FFR CT Planner. Eur Radiol 2024; 34:2677-2688. [PMID: 37798406 DOI: 10.1007/s00330-023-10228-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 07/03/2023] [Accepted: 07/30/2023] [Indexed: 10/07/2023]
Abstract
OBJECTIVE To assess the accuracy of a virtual stenting tool based on coronary CT angiography (CCTA) and fractional flow reserve (FFR) derived from CCTA (FFRCT Planner) across different levels of image quality. MATERIALS AND METHODS Prospective, multicenter, single-arm study of patients with chronic coronary syndromes and lesions with FFR ≤ 0.80. All patients underwent CCTA performed with recent-generation scanners. CCTA image quality was adjudicated using the four-point Likert scale at a per-vessel level by an independent committee blinded to the FFRCT Planner. Patient- and technical-related factors that could affect the FFRCT Planner accuracy were evaluated. The FFRCT Planner was applied mirroring percutaneous coronary intervention (PCI) to determine the agreement with invasively measured post-PCI FFR. RESULTS Overall, 120 patients (123 vessels) were included. Invasive post-PCI FFR was 0.88 ± 0.06 and Planner FFRCT was 0.86 ± 0.06 (mean difference 0.02 FFR units, the lower limit of agreement (LLA) - 0.12, upper limit of agreement (ULA) 0.15). CCTA image quality was assessed as excellent (Likert score 4) in 48.3%, good (Likert score 3) in 45%, and sufficient (Likert score 2) in 6.7% of patients. The FFRCT Planner was accurate across different levels of image quality with a mean difference between FFRCT Planner and invasive post-PCI FFR of 0.02 ± 0.07 in Likert score 4, 0.02 ± 0.07 in Likert score 3 and 0.03 ± 0.08 in Likert score 2, p = 0.695. Nitrate dose ≥ 0.8mg was the only independent factor associated with the accuracy of the FFRCT Planner (95%CI - 0.06 to - 0.001, p = 0.040). CONCLUSION The FFRCT Planner was accurate in predicting post-PCI FFR independent of CCTA image quality. CLINICAL RELEVANCE STATEMENT Being accurate in predicting post-PCI FFR across a wide spectrum of CT image quality, the FFRCT Planner could potentially enhance and guide the invasive treatment. Adequate vasodilation during CT acquisition is relevant to improve the accuracy of the FFRCT Planner. KEY POINTS • The fractional flow reserve derived from coronary CT angiography (FFRCT) Planner is a novel tool able to accurately predict fractional flow reserve after percutaneous coronary intervention. • The accuracy of the FFRCT Planner was confirmed across a wide spectrum of CT image quality. Nitrates dose at CT acquisition was the only independent predictor of its accuracy. • The FFRCT Planner could potentially enhance and guide the invasive treatment.
Collapse
Affiliation(s)
- Daniele Andreini
- Clinical Cardiology and Cardiovascular Imaging Unit, Galeazzi-Sant'Ambrogio Hospital, IRCCS, Via Cristina Belgioioso 173, 20157, Milan, Italy.
- Department of Biomedical and Clinical Sciences, University of Milan, Milan, Italy.
| | - Marta Belmonte
- Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium
- Department of Advanced Biomedical Sciences, University Federico II, Naples, Italy
| | | | | | - Niya Mileva
- Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium
- Medical University of Sofia, Sofia, Bulgaria
| | - Pasquale Paolisso
- Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium
- Department of Advanced Biomedical Sciences, University Federico II, Naples, Italy
| | - Sakura Nagumo
- Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium
- Department of Cardiology, Showa University Fujigaoka Hospital, Yokohama, Kanagawa, Japan
| | - Bjarne L Nørgaard
- Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
| | - Brian Ko
- Monash Cardiovascular Research Centre, Monash University and Monash Heart, Monash Health, Clayton, VIC, Australia
| | - Hiromasa Otake
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Bon-Kwon Koo
- Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, Korea
| | | | - Takuya Mizukami
- Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium
- Department of Cardiology, Showa University Fujigaoka Hospital, Yokohama, Kanagawa, Japan
| | - Daniel Munhoz
- Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium
- Department of Advanced Biomedical Sciences, University Federico II, Naples, Italy
| | | | | | - Jonathon Leipsic
- Department of Medicine and Radiology, University of British Columbia, Vancouver, BC, Canada
| | - Jeroen Sonck
- Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium
| | - Bernard De Bruyne
- Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Carlos Collet
- Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium
| |
Collapse
|
3
|
Singhal M, Pilania RK, Gupta P, Johnson N, Singh S. Emerging role of computed tomography coronary angiography in evaluation of children with Kawasaki disease. World J Clin Pediatr 2023; 12:97-106. [PMID: 37342454 PMCID: PMC10278081 DOI: 10.5409/wjcp.v12.i3.97] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Revised: 05/08/2023] [Accepted: 05/22/2023] [Indexed: 06/08/2023] Open
Abstract
Coronary artery abnormalities are the most important complications in children with Kawasaki disease (KD). Two-dimensional transthoracic echocardiography currently is the standard of care for initial evaluation and follow-up of children with KD. However, it has inherent limitations with regard to evaluation of mid and distal coronary arteries and, left circumflex artery and the poor acoustic window in older children often makes evaluation difficult in this age group. Catheter angiography (CA) is invasive, has high radiation exposure and fails to demonstrate abnormalities beyond lumen. The limitations of echocardiography and CA necessitate the use of an imaging modality that overcomes these problems. In recent years advances in computed tomography technology have enabled explicit evaluation of coronary arteries along their entire course including major branches with optimal and acceptable radiation exposure in children. Computed tomography coronary angiography (CTCA) can be performed during acute as well as convalescent phases of KD. It is likely that CTCA may soon be considered the reference standard imaging modality for evaluation of coronary arteries in children with KD.
Collapse
Affiliation(s)
- Manphool Singhal
- Departments of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research, Chandigarh 160012, Chandigarh, India
| | - Rakesh Kumar Pilania
- Pediatric Allergy Immunology Unit, Department of Paediatrics, Advanced Pediatrics Center, Postgraduate Institute of Medical Education and Research, Chandigarh 160012, Chandigarh, India
| | - Pankaj Gupta
- Departments of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research, Chandigarh 160012, Chandigarh, India
| | - Nameirakpam Johnson
- Pediatric Allergy Immunology Unit, Department of Paediatrics, Advanced Pediatrics Center, Postgraduate Institute of Medical Education and Research, Chandigarh 160012, Chandigarh, India
| | - Surjit Singh
- Pediatric Allergy Immunology Unit, Department of Paediatrics, Advanced Pediatrics Center, Postgraduate Institute of Medical Education and Research, Chandigarh 160012, Chandigarh, India
| |
Collapse
|
4
|
Coronary Artery Stent Evaluation by CTA: Impact of Deep Learning Reconstruction and Subtraction Technique. AJR Am J Roentgenol 2023; 220:63-72. [PMID: 35946861 DOI: 10.2214/ajr.22.27983] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
BACKGROUND. Coronary CTA with hybrid iterative reconstruction (HIR) is prone to false-positive results for in-stent restenosis due to stent-related blooming artifact. OBJECTIVE. The purpose of this study is to assess the impact of deep learning reconstruction (DLR), subtraction images, and the combination of DLR and subtraction images on the diagnostic performance of coronary CTA for the detection of in-stent restenosis. METHODS. This prospective study included patients with coronary stents who underwent coronary CTA between March 2020 and August 2021. CTA used a technique with two breath-holds (noncontrast and contrast-enhanced acquisitions). Conventional and subtraction images were reconstructed for HIR and DLR. The maximum visible instent lumen diameter was measured. Two readers independently evaluated images for in-stent restenosis (≥ 50% stenosis). A simulated assessment of combined conventional and subtraction images was generated, reflecting assessment of conventional and subtraction images in the presence or absence of severe misregistration artifact, respectively. Invasive angiography served as reference standard. RESULTS. The study enrolled 30 patients (22 men and eight women; mean age, 63.6 ± 7.4 [SD] years) with a total of 59 stents; severe misregistration artifact was present for 32 stents. Maximum visible in-stent lumen diameter was higher for DLR than for HIR (2.3 ± 0.5 vs 2.1 ± 0.5 mm, p < .001), and among stents without severe misregistration artifact, it was higher for subtraction than conventional DLR (3.0 ± 0.5 vs 2.4 ± 0.5, p < .001). Among conventional CTA with HIR, conventional CTA with DLR, combination (conventional and subtraction) approach with HIR, and combination (conventional and subtraction) approach with DLR, the highest patient-level diagnostic performance measures were as follows: for reader 1, sensitivity was identical (62.5%), specificity was highest for combination with DLR (90.1%), PPV was highest for combination with DLR (71.4%), NPV was highest for combination with DLR (87.0%), and accuracy was highest for combination with DLR (83.3%); for reader 2, sensitivity was identical (50.0%), specificity was highest for combination with HIR or DLR (both 95.5%), PPV was highest for combination with HIR or DLR (both 80.0%), NPV was highest for combination with HIR or DLR (84.0%), and accuracy was highest for combination with HIR or DLR (both 83.3%). CONCLUSION. The combined DLR and subtraction technique yielded optimal diagnostic performance for detecting in-stent restenosis by coronary CTA. CLINICAL IMPACT. The described technique could guide patient selection for invasive coronary stent evaluation.
Collapse
|
5
|
Canan A, Barbosa MF, Nomura CH, Abbara S, Kay FU. Cardiac CT Perfusion Imaging. CURRENT RADIOLOGY REPORTS 2022. [DOI: 10.1007/s40134-022-00406-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
6
|
Chun SH, Suh YJ, Han K, Kwon Y, Kim AY, Choi BW. Deep learning-based reconstruction on cardiac CT yields distinct radiomic features compared to iterative and filtered back projection reconstructions. Sci Rep 2022; 12:15171. [PMID: 36071138 PMCID: PMC9452656 DOI: 10.1038/s41598-022-19546-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 08/30/2022] [Indexed: 11/09/2022] Open
Abstract
We aimed to determine the effects of deep learning-based reconstruction (DLR) on radiomic features obtained from cardiac computed tomography (CT) by comparing with iterative reconstruction (IR), and filtered back projection (FBP). A total of 284 consecutive patients with 285 cardiac CT scans that were reconstructed with DLR, IR, and FBP, were retrospectively enrolled. Radiomic features were extracted from the left ventricular (LV) myocardium, and from the periprosthetic mass if patients had cardiac valve replacement. Radiomic features of LV myocardium from each reconstruction were compared using a fitting linear mixed model. Radiomics models were developed to diagnose periprosthetic abnormality, and the performance was evaluated using the area under the receiver characteristics curve (AUC). Most radiomic features of LV myocardium (73 of 88) were significantly different in pairwise comparisons between all three reconstruction methods (P < 0.05). The radiomics model on IR exhibited the best diagnostic performance (AUC 0.948, 95% CI 0.880-1), relative to DLR (AUC 0.873, 95% CI 0.735-1) and FBP (AUC 0.875, 95% CI 0.731-1), but these differences did not reach significance (P > 0.05). In conclusion, applying DLR to cardiac CT scans yields radiomic features distinct from those obtained with IR and FBP, implying that feature robustness is not guaranteed when applying DLR.
Collapse
Affiliation(s)
- Sei Hyun Chun
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Young Joo Suh
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea.
| | - Kyunghwa Han
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Yonghan Kwon
- Department of Biostatistics and Computing, Yonsei University Graduate School, Seoul, Korea
| | | | - Byoung Wook Choi
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| |
Collapse
|
7
|
Adebo DA, Schoeneberg L. Dual-source and prospective gated low dose neonatal cardiac computed tomography in evaluation of congenital heart disease. PROGRESS IN PEDIATRIC CARDIOLOGY 2022. [DOI: 10.1016/j.ppedcard.2021.101447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
8
|
Wang Y, Chen Y, Liu P, Lv W, Wu J, Wei M, Shi D, Wu X, Liu W, Tao X, Hu H, Ma X, Yang X, Xue H, Jin Z. Clinical effectiveness of contrast medium injection protocols for 80-kV coronary and craniocervical CT angiography-a prospective multicenter observational study. Eur Radiol 2022; 32:3808-3818. [PMID: 35103828 DOI: 10.1007/s00330-021-08505-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 10/22/2021] [Accepted: 12/04/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND AND OBJECTIVE Decreasing X-ray tube voltage is an effective way to reduce radiation and contrast dose, especially in non-obese patients. The current study focuses on CTA in non-obese patients to evaluate image quality and feasibility of 80-kV acquisition protocols with varying iodine delivery rates (IDR) and contrast concentrations in routine clinical practice. METHODS A prospective observational study in patients ≥ 18 years and ≤ 90 kg referred for coronary or craniocervical CTA at 10 centers in China (ClinicalTrials.gov: NCT02840903). Patients were divided into four groups: a standard 100-kV protocol (370 mgI/ml, IDR 1.48 gI/s), and three 80-kV protocols (370 mgI/ml, IDR 1.2 gI/s; 300 mgI/ml, IDR 1.2 gI/s; 300 mgI/ml, IDR 0.96gI/s). The primary outcome was contrast opacification of target vascular segments. Secondary outcomes were image quality (contrast-to-noise ratio, signal-to-noise ratio, visual image quality, and diagnostic confidence assessment), radiation, and iodine dose. RESULTS From July 2016 to July 2017, 1213 patients were enrolled: 614 coronary and 599 craniocervical CTA. The mean contrast opacification was ≥ 300 HU for 80-kV 1.2 gI/s IDR scanned segments; IDR 0.96 gI/s led to lower opacification. Image quality and diagnostic confidence were fair to excellent (≥ 98% of images), despite lower contrast-to-noise ratios and signal-to-noise ratios in 80-kV images. Compared to the standard protocol, 80-kV protocols led to 44-52% radiation dose reductions (p < 0.001) and 19% iodine dose reductions (p < 0.001). CONCLUSION Eighty-kilovolt 1.2 gI/s IDR protocols can be recommended for coronary and craniocervical CTA in non-obese patients, reducing radiation and iodine dose without compromising image quality. KEY POINTS • Using low-voltage scanning CTA protocols, in which tube voltage and iodine delivery rate are reduced proportionally (voltage: 80 kV, IDR: 1.2 gI/s), reduces radiation and contrast dose without compromising image quality in routine clinical practice. • Reducing iodine delivery rate beyond direct proportionality to tube voltage is not beneficial.
Collapse
Affiliation(s)
- Yining Wang
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Yu Chen
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Peijun Liu
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Wan Lv
- The First People's Hospital of Yulin, # 495, JiaoYu Central Road, Yulin, 537000, Guangxi, China
| | - Jianlin Wu
- Affiliated Zhongshan Hospital of Dalian University, # 6, Jiefang Road Zhongshan District, Dalian, 116001, Liaoning, China
| | - Mengqi Wei
- The First Affiliated Hospital of Air Force Medical University, # 15 Changle West Road, Xian, 710032, Shanxi, China
| | - Dapeng Shi
- Henan Provincial People's Hospital, # 7, Weiwu Road, Zhengzhou, 450000, Henan, China
| | - Xianheng Wu
- The Second People's Hospital of Shantou, # 28, Waimalu Road, Shantou, 515031, Guangdong, China
| | - Wenya Liu
- The First Affiliated Hospital of Xinjiang Medical University, # 137, Liyushan South Road, Urumqi, 830054, Xinjiang, China
| | - Xiaofeng Tao
- Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, # 639, Zaoju Road, Shanghai, 200011, China
| | - Hongjie Hu
- Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 Qinchun East Road, Hangzhou, 310016, Zhejiang, China
| | - Xiangxing Ma
- Qilu Hospital of Shandong University (Qingdao), North District, # 758, Hefei Road, Qingdao, 266035, Shandong, China
| | - Xiaozheng Yang
- Medical Affairs, Bayer Healthcare Co. Ltd, Dongshanhuan Central Road, Beijing, 100010, China
| | - Huadan Xue
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Zhengyu Jin
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China.
| |
Collapse
|
9
|
Ngaile JE, Msaki PK, Suleiman SA, Chuma FM, Muhogora WE, Jusabani AM. ESTIMATION OF PATIENT RADIATION DOSES FROM MULTI-DETECTOR COMPUTED TOMOGRAPHY ANGIOGRAPHY PROCEDURES IN TANZANIA. RADIATION PROTECTION DOSIMETRY 2021; 197:63-77. [PMID: 34729602 DOI: 10.1093/rpd/ncab159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Revised: 09/08/2021] [Accepted: 10/05/2021] [Indexed: 06/13/2023]
Abstract
The aim of the present study was to estimate the volume CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED) to patients from five multi-detector computed tomography angiography (MDCTA) procedures: brain, carotid, coronary, entire aorta and lower limb from four medical institutions in Tanzania; to compare these doses to those reported in the literature, and to compare the data obtained with ICRP 103 and Monte Carlo software. The radiation doses for 217 patients were estimated using patient demographics, patient-related exposure parameters, the geometry of examination and CT-Expo V 2.4 Monte Carlo-based software. The median values of the CTDIvol, DLP and ED for MDCTA procedures of the brain and carotids were 36.8 mGy, 1481.0 mGy∙cm and 5.2 mSv, and 15.9 mGy, 1224.0 mGy∙cm and 7.8 mSv, respectively; while for the coronary, entire aortic, and lower limbs were 49.4 mGy, 1493.0 mGy∙cm and 30.6 mSv; 16.2 mGy, 2287.0 mGy∙cm and 41.1 mSv; and 6.4 mGy, 1406.0 mGy∙cm and 10.5 mSv, respectively. The ratio of the maximum to minimum ED values to individual patients across the four medical centers were 41.4, 11.1, 4.6, 9.5 and 37.4, respectively, for the brain, carotid, coronary, entire aortic and lower limb CT angiography procedures. The mean values of CTDIvol, DLP and ED in the present study were typically higher than the values reported from Kenya, Korea and Saudi Arabia. The 75th percentile values of the DLP were above the preliminary diagnostic references levels proposed by Kenya, Switzerland and Korea. The observed wide range of examination scanning protocols and patient doses for similar MDCTA procedures within and across hospitals; and the observed relatively high patient doses compared to those reported in the literature, call for the need to standardize scanning protocols and optimise patient dose from MDCTA procedures.
Collapse
Affiliation(s)
- J E Ngaile
- Radiation Control Directorate, Tanzania Atomic Energy Commission, P O Box 743 Arusha, Tanzania
- Department of Physics, University of Dar es Salaam, P O Box 35063 Dar es Salaam, Tanzania
| | - P K Msaki
- Department of Physics, University of Dar es Salaam, P O Box 35063 Dar es Salaam, Tanzania
| | - S A Suleiman
- Radiation Control Directorate, Tanzania Atomic Energy Commission, P O Box 743 Arusha, Tanzania
| | - F M Chuma
- Radiation Control Directorate, Tanzania Atomic Energy Commission, P O Box 743 Arusha, Tanzania
| | - W E Muhogora
- Radiation Control Directorate, Tanzania Atomic Energy Commission, P O Box 743 Arusha, Tanzania
| | - A M Jusabani
- Department of Radiology, The Agha Khan Hospital, P O Box 2289 Dar es Salaam, Tanzania
| |
Collapse
|
10
|
John S, Schoeneberg L, Greenleaf CE, Salazar JD, Adebo DA. Pre- and post-operative cardiovascular CT in Stage I single ventricle palliation. J Card Surg 2021; 37:322-328. [PMID: 34845746 DOI: 10.1111/jocs.16162] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Accepted: 11/18/2021] [Indexed: 12/25/2022]
Abstract
OBJECTIVES The aim of this study is to describe clinical utility of low dose cardiac computed tomography (CT) in the evaluation of single ventricle physiology before and after Stage I palliation. BACKGROUND Despite the increased utilization of CT imaging and advancement of CT technology, there are limited studies describing the routine clinical use of cardiac CT and radiation dose parameters in the single ventricle Stage I palliation. METHODS This single center, retrospective study included 57 infants with single ventricle physiology who underwent cardiac CT scans between January 1, 2016 and November 30, 2020. Patients' demographic information, diagnosis, indication, total dose length product (DLP), computed tomographic dose index volume (CTDIvol), cardiac CT findings and intraoperative or intraprocedural findings were reviewed. Estimated effective radiation dose was calculated using a previously published conversion rate. RESULTS The studies were performed using different generations of CT scanners over the 4 years period: Somatom AS 128, Somatom definition edge, Somatom Force (Siemens Medical Solutions). The studies performed with dual source scanner with prospective gated technique have lower radiation dose exposure with median effective radiation dose of 0.32 mSv. CONCLUSION Pre- and post-operative cardiovascular CT in Stage I single ventricle palliation using newer generation scanners with prospective gated technique can be done with minimal radiation exposure and good image quality. Cardiac CT is a powerful imaging modality for better management planning in this group of patients.
Collapse
Affiliation(s)
- Sheba John
- Division of Pediatric Cardiology, Children's Heart Institute, University of Texas Medical School at Houston, Houston, Texas, USA
| | - Laura Schoeneberg
- Division of Pediatric Cardiology, Children's Heart Institute, University of Texas Medical School at Houston, Houston, Texas, USA
| | - Christopher E Greenleaf
- Division of Cardiothoracic Surgery, Children's Heart Institute, Memorial Hermann Hospital, University of Texas Health McGovern Medical School, Houston, Texas, USA
| | - Jorge D Salazar
- Division of Cardiothoracic Surgery, Children's Heart Institute, Memorial Hermann Hospital, University of Texas Health McGovern Medical School, Houston, Texas, USA
| | - Dilachew A Adebo
- Division of Pediatric Cardiology, Children's Heart Institute, University of Texas Medical School at Houston, Houston, Texas, USA
| |
Collapse
|
11
|
Yi Y, Xu C, Xu M, Yan J, Li YY, Wang J, Yang SJ, Guo YB, Wang Y, Li YM, Jin ZY, Wang YN. Diagnostic Improvements of Deep Learning-Based Image Reconstruction for Assessing Calcification-Related Obstructive Coronary Artery Disease. Front Cardiovasc Med 2021; 8:758793. [PMID: 34805313 PMCID: PMC8595262 DOI: 10.3389/fcvm.2021.758793] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Accepted: 10/01/2021] [Indexed: 11/17/2022] Open
Abstract
Objectives: The objective of this study was to explore the diagnostic value of deep learning-based image reconstruction (DLR) and hybrid iterative reconstruction (HIR) for calcification-related obstructive coronary artery disease (CAD) evaluation by using coronary CT angiography (CCTA) images and subtraction CCTA images. Methods: Forty-two consecutive patients with known or suspected coronary artery disease who underwent coronary CTA on a 320-row CT scanner and subsequent invasive coronary angiography (ICA), which was used as the reference standard, were enrolled. The DLR and HIR images were reconstructed as CTADLR and CTAHIR, and, based on which, the corresponding subtraction CCTA images were established as CTAsDLR and CTAsHIR, respectively. Qualitative images quality comparison was performed by using a Likert 4 stage score, and quantitative images quality parameters, including image noise, signal-to-noise ratio, and contrast-to-noise ratio were calculated. Diagnostic performance on the lesion level was assessed and compared among the four CCTA approaches (CTADLR, CTAHIR, CTAsDLR, and CTAsHIR). Results: There were 166 lesions of 86 vessels in 42 patients (32 men and 10 women; 62.9 ± 9.3 years) finally enrolled for analysis. The qualitative and quantitative image qualities of CTAsDLR and CTADLR were superior to those of CTAsHIR and CTAHIR, respectively. The diagnostic accuracies of CTAsDLR, CTADLR, CTAsHIR, and CTAHIR to identify calcification-related obstructive diameter stenosis were 83.73%, 69.28%, 75.30%, and 65.66%, respectively. The false-positive rates of CTAsDLR, CTADLR, CTAsHIR, and CTAHIR for luminal diameter stenosis ≥50% were 15%, 31%, 24%, and 34%, respectively. The sensitivity and the specificity to identify ≥50% luminal diameter stenosis was 90.91% and 83.23% for CTAsDLR. Conclusion: Our study showed that deep learning–based image reconstruction could improve the image quality of CCTA images and diagnostic performance for calcification-related obstructive CAD, especially when combined with subtraction technique.
Collapse
Affiliation(s)
- Yan Yi
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Cheng Xu
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Min Xu
- Canon Medical System, Beijing, China
| | - Jing Yan
- Canon Medical System, Beijing, China
| | - Yan-Yu Li
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jian Wang
- Canon Medical System, Beijing, China
| | - Si-Jie Yang
- Medical Science Research Center, Peking Union Medical College Hospital, Beijing, China
| | - Yu-Bo Guo
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yun Wang
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yu-Mei Li
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Zheng-Yu Jin
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yi-Ning Wang
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
12
|
Xu C, Yi Y, Han Y, Xie H, Lu X, Vembar M, Leiner T, Jin Z, Wang Y. Incremental improvement of diagnostic performance of coronary CT angiography for the assessment of coronary stenosis in the presence of calcium using a dual-layer spectral detector CT: validation by invasive coronary angiography. Int J Cardiovasc Imaging 2021; 37:2561-2572. [PMID: 34176031 DOI: 10.1007/s10554-021-02205-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Accepted: 02/22/2021] [Indexed: 01/10/2023]
Abstract
To investigate value of spectral reconstructions for the quantification of coronary stenosis in the presence of calcified or partially calcified plaques using a dual-layer spectral detector CT (SDCT). Seventy-two consecutive patients were retrospectively enrolled. Conventional 120 kVp images, eight virtual monoenergetic images (VMI) (70 to 140 keV), the effective atomic number (Z effective) and iodine no water images were reconstructed. Invasive coronary angiography was used as the reference standard. Parallel and serial testing were used to assess the incremental diagnostic value of Z effective and iodine no water images to the best VMI series. 122 coronary lesions of 72 patients (49 men and 23 women; 63.7 ± 10.2 years) were enrolled in analysis. Reconstruction at 100 keV yielded optimal diagnostic performance, the sensitivity, specificity, PPV, NPV and diagnostic accuracy to identify stenosis ≥ 50% or ≥ 70% were 84%, 70%, 80%, 76%, 79% and 78%, 98%, 93%, 91%, 92%, respectively. A serial combination (100 keV VMI followed by Z effective images) resulted in an improved specificity (from 70 to 80%) with a moderate loss of sensitivity (81% from 84%) in identifying ≥ 50% stenosis (P = 0.021). For patients with high Agatston score, this combination could further reduce false positive cases and improve diagnostic accuracy. 100 keV VMI provide optimal diagnostic performance for the detection of coronary stenosis in the presence of calcified or partially calcified plaques using a dual-layer SDCT, with further improvements obtained with the combined use of Z effective images.
Collapse
Affiliation(s)
- Cheng Xu
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College , No.1, Shuaifuyuan, Dongcheng District, Beijing, 100730, China
| | - Yan Yi
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College , No.1, Shuaifuyuan, Dongcheng District, Beijing, 100730, China
| | - Yechen Han
- Department of Cardiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Hongzhi Xie
- Department of Cardiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xiaomei Lu
- Clinical Science, Philips Healthcare, Beijing, China
| | - Mani Vembar
- CT Clinical Science, Philips Healthcare, Cleveland, OH, USA
| | - Tim Leiner
- Department of Radiology, University Medical Center of Utrecht, Utrecht, The Netherlands
| | - Zhengyu Jin
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College , No.1, Shuaifuyuan, Dongcheng District, Beijing, 100730, China
| | - Yining Wang
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College , No.1, Shuaifuyuan, Dongcheng District, Beijing, 100730, China.
| |
Collapse
|
13
|
Ha S, Jung S, Park HB, Shin S, Arsanjani R, Hong Y, Lee BK, Jang Y, Jeon B, Park SI, Shim H, Chang HJ. Assessment of Image Quality for Selective Intracoronary Contrast-Injected CT Angiography in a Hybrid Angio-CT System: A Feasibility Study in Swine. Yonsei Med J 2021; 62:200-208. [PMID: 33635009 PMCID: PMC7934100 DOI: 10.3349/ymj.2021.62.3.200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 12/03/2020] [Accepted: 12/14/2020] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To compare image quality in selective intracoronary contrast-injected computed tomography angiography (Selective-CTA) with that in conventional intravenous contrast-injected CTA (IV-CTA). MATERIALS AND METHODS Six pigs (35 to 40 kg) underwent both IV-CTA using an intravenous injection (60 mL) and Selective-CTA using an intracoronary injection (20 mL) through a guide-wire during/after percutaneous coronary intervention. Images of the common coronary artery were acquired. Scans were performed using a combined machine comprising an invasive coronary angiography suite and a 320-channel multi-slice CT scanner. Quantitative image quality parameters of CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), mean lumen diameter (MLD), and mean lumen area (MLA) were measured and compared. Qualitative analysis was performed using intraclass correlation coefficient (ICC), which was calculated for analysis of interobserver agreement. RESULTS Quantitative image quality, determined by assessing the uniformity of CT attenuation (399.06 vs. 330.21, p<0.001), image noise (24.93 vs. 18.43, p<0.001), SNR (16.43 vs. 18.52, p=0.005), and CNR (11.56 vs. 13.46, p=0.002), differed significantly between IV-CTA and Selective-CTA. MLD and MLA showed no significant difference overall (2.38 vs. 2.44, p=0.068, 4.72 vs. 4.95, p=0.078). The density of contrast agent was significantly lower for selective-CTA (13.13 mg/mL) than for IV-CTA (400 mg/mL). Agreement between observers was acceptable (ICC=0.79±0.08). CONCLUSION Our feasibility study in swine showed that compared to IV-CTA, Selective-CTA provides better image quality and requires less iodine contrast medium.
Collapse
Affiliation(s)
- Seongmin Ha
- Graduate School of Biomedical Engineering, Yonsei University College of Medicine, Seoul, Korea
- CONNECT-AI R&D Center, Yonsei University College of Medicine, Seoul, Korea
| | - Sunghee Jung
- CONNECT-AI R&D Center, Yonsei University College of Medicine, Seoul, Korea
- Brain Korea 21 PLUS Project for Medical Science, Yonsei University, Seoul, Korea
| | - Hyung Bok Park
- Division of Cardiology, Cardiovascular Center, Myongji Hospital, Seonam University College of Medicine, Goyang, Korea
| | - Sanghoon Shin
- Division of Cardiology, National Health Insurance Corporation Ilsan Hospital, Goyang, Korea
| | - Reza Arsanjani
- Cardiovascular Center, Mayo Clinic Scottsdale, Scottsdale, Arizona, USA
| | - Youngtaek Hong
- CONNECT-AI R&D Center, Yonsei University College of Medicine, Seoul, Korea
| | - Byoung Kwon Lee
- Division of Cardiology, Department of Internal Medicine, Heart Center, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Yeonggul Jang
- CONNECT-AI R&D Center, Yonsei University College of Medicine, Seoul, Korea
| | - Byunghwan Jeon
- CONNECT-AI R&D Center, Yonsei University College of Medicine, Seoul, Korea
| | - Se Il Park
- Cardiovascular Product Evaluation Center, Yonsei University College of Medicine, Seoul, Korea
| | - Hackjoon Shim
- Cardiovascular Research Institute, Yonsei University College of Medicine, Seoul, Korea
| | - Hyuk Jae Chang
- CONNECT-AI R&D Center, Yonsei University College of Medicine, Seoul, Korea
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University Health System, Seoul, Korea.
| |
Collapse
|
14
|
Bathla G, Priya S, Samaniego E, Deo SK, Fain NH, Soni N, Ward C, Derdeyn CP. Cerebral computed tomographic angiography using third-generation reconstruction algorithm provides improved image quality with lower contrast and radiation dose. Neuroradiology 2020; 62:965-970. [PMID: 32277245 DOI: 10.1007/s00234-020-02406-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Accepted: 03/13/2020] [Indexed: 02/03/2023]
Abstract
PURPOSE We hypothesized that cerebral CT angiogram performed using third-generation reconstruction algorithm and lower contrast dose-low-kVp technique (LD-CTA) will provide better image quality when compared with regular contrast dose CTA at 120 kVp using a sinogram-affirmed iterative reconstruction algorithm (ND-CTA). METHODS Retrospective imaging review of 100 consecutive patients (50 each in LD- and ND-CTA groups). Two readers independently assessed the subjective image quality across multiple vascular segments on a Likert-like scale. Differences in contrast dose, CT dose index (CTDI), and dose length product (DLP) were compared using Mann-Whitney U test. Fisher's exact test was used to compare subjective image quality. Similarly, contrast- and signal-to-noise ratios (CNR and SNR) were compared in the mid-M1 MCA vessels bilaterally and the mid-basilar artery using Mann-Whitney U test. Interclass correlation coefficient (ICC) was calculated for the SNR/CNR values. RESULTS Both observers showed excellent correlation in subjective image quality (mean percentage agreement of 95.2% for group 1 versus 89.2% for group 2). LD-CTA group showed better SNR and CNR (p < 0.0001) for both MCA vessels and the mid-basilar artery. Interclass correlation coefficient showed moderate correlation (0.51-0.63) between readers. LD-CTA group also used lower contrast (49 cc versus 97 cc in ND-CTA) and had lower radiation exposure (DLP/CTDI for both groups 268.3/80.7 vs 519.5/36.08, both < 0.0001). CONCLUSION Next-generation reconstruction algorithm and low-kV scanning significantly improved image quality on cerebral CTA images despite lower contrast dose and, in addition, have lower radiation exposure.
Collapse
Affiliation(s)
- Girish Bathla
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA.
| | - Sarv Priya
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| | - Edgar Samaniego
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
- Department of Neurology, University of Iowa Hospitals and Clinics, Iowa City, IA, USA
| | - Simmi K Deo
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| | - Nicholas H Fain
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| | - Neetu Soni
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| | - Caitlin Ward
- Department of Biostatistics, University of Iowa, Iowa City, IA, USA
| | - Colin P Derdeyn
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| |
Collapse
|
15
|
Muscogiuri G, Chiesa M, Trotta M, Gatti M, Palmisano V, Dell'Aversana S, Baessato F, Cavaliere A, Cicala G, Loffreno A, Rizzon G, Guglielmo M, Baggiano A, Fusini L, Saba L, Andreini D, Pepi M, Rabbat MG, Guaricci AI, De Cecco CN, Colombo G, Pontone G. Performance of a deep learning algorithm for the evaluation of CAD-RADS classification with CCTA. Atherosclerosis 2019; 294:25-32. [PMID: 31945615 DOI: 10.1016/j.atherosclerosis.2019.12.001] [Citation(s) in RCA: 68] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Revised: 12/01/2019] [Accepted: 12/06/2019] [Indexed: 12/22/2022]
Abstract
BACKGROUND AND AIMS Artificial intelligence (AI) is increasing its role in diagnosis of patients with suspicious coronary artery disease. The aim of this manuscript is to develop a deep convolutional neural network (CNN) to classify coronary computed tomography angiography (CCTA) in the correct Coronary Artery Disease Reporting and Data System (CAD-RADS) category. METHODS Two hundred eighty eight patients who underwent clinically indicated CCTA were included in this single-center retrospective study. The CCTAs were stratified by CAD-RADS scores by expert readers and considered as reference standard. A deep CNN was designed and tested on the CCTA dataset and compared to on-site reading. The deep CNN analyzed the diagnostic accuracy of the following three Models based on CAD-RADS classification: Model A (CAD-RADS 0 vs CAD-RADS 1-2 vs CAD-RADS 3,4,5), Model 1 (CAD-RADS 0 vs CAD-RADS>0), Model 2 (CAD-RADS 0-2 vs CAD-RADS 3-5). Time of analysis for both physicians and CNN were recorded. RESULTS Model A showed a sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 47%, 74%, 77%, 46% and 60%, respectively. Model 1 showed a sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 66%, 91%, 92%, 63%, 86%, respectively. Conversely, Model 2 demonstrated the following sensitivity, specificity, negative predictive value, positive predictive value and accuracy: 82%, 58%, 74%, 69%, 71%, respectively. Time of analysis was significantly lower using CNN as compared to on-site reading (530.5 ± 179.1 vs 104.3 ± 1.4 sec, p=0.01) CONCLUSIONS: Deep CNN yielded accurate automated classification of patients with CAD-RADS.
Collapse
Affiliation(s)
| | | | - Michela Trotta
- Department of Electrical, Computer and Biomedical Engineering, University of Pavia, Pavia, Italy
| | - Marco Gatti
- Department of Surgical Sciences, Radiology Institute, University of Turin, Turin, Italy
| | - Vitanio Palmisano
- Department of Medical Imaging, University of Cagliari, Monserrato, Italy
| | - Serena Dell'Aversana
- Department of Advanced Biomedical Sciences, University of Naples "Federico II,", Naples, Italy
| | - Francesca Baessato
- Section of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | - Annachiara Cavaliere
- Department of Medicine, Institute of Radiology, University of Padova, Padua, Italy
| | - Gloria Cicala
- Section of Radiology, Department of Medicine and Surgery, University of Parma, Parma, Italy
| | | | - Giulia Rizzon
- Department of Medicine, Institute of Radiology, University of Padova, Padua, Italy
| | | | | | - Laura Fusini
- Centro Cardiologico Monzino, IRCCS, Milan, Italy
| | - Luca Saba
- Department of Medical Imaging, University of Cagliari, Monserrato, Italy
| | - Daniele Andreini
- Centro Cardiologico Monzino, IRCCS, Milan, Italy; Department of Cardiovascular Sciences and Community Health, University of Milan, Italy
| | - Mauro Pepi
- Centro Cardiologico Monzino, IRCCS, Milan, Italy
| | - Mark G Rabbat
- Loyola University of Chicago, Chicago, IL, USA; Edward Hines Jr. VA Hospital, Hines, IL, USA
| | - Andrea I Guaricci
- Institute of Cardiovascular Disease, Department of Emergency and Organ Transplantation, University Hospital "Policlinico Consorziale" of Bari, Bari, Italy
| | - Carlo N De Cecco
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA
| | | | | |
Collapse
|
16
|
Richards CE, Obaid DR. Low-Dose Radiation Advances in Coronary Computed Tomography Angiography in the Diagnosis of Coronary Artery Disease. Curr Cardiol Rev 2019; 15:304-315. [PMID: 30806322 PMCID: PMC8142354 DOI: 10.2174/1573403x15666190222163737] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Revised: 12/24/2018] [Accepted: 12/26/2018] [Indexed: 01/16/2023] Open
Abstract
Background
Coronary computed tomography angiography (CCTA) is now widely used in the diagnosis of coronary artery disease since it is a rapid, minimally invasive test with a diagnostic accuracy comparable to coronary angiography. However, to meet demands for increasing spatial and temporal resolution, higher x-ray radiation doses are required to circumvent the resulting increase in image noise. Exposure to high doses of ionizing radiation with CT imaging is a major health concern due to the potential risk of radiation-associated malignancy. Given its increasing use, a number of dose saving algorithms have been implemented to CCTA to minimize radiation exposure to “as low as reasonably achievable (ALARA)” without compromising diagnostic image quality. Objective
The purpose of this review is to outline the most recent advances and current status of dose saving techniques in CCTA. Method
PubMed, Medline, EMBASE and Scholar databases were searched to identify feasibility studies, clinical trials, and technology guidelines on the technical advances in CT scanner hardware and reconstruction software. Results
Sub-millisievert (mSv) radiation doses have been reported for CCTA due to a combination of strategies such as prospective electrocardiogram-gating, high-pitch helical acquisition, tube current modulation, tube voltage reduction, heart rate reduction, and the most recent novel adaptive iterative reconstruction algorithms. Conclusion
Advances in radiation dose reduction without loss of image quality justify the use of CCTA as a non-invasive alternative to coronary catheterization in the diagnosis of coronary artery disease.
Collapse
Affiliation(s)
- Caryl E Richards
- Department of Cardiology, Morriston Hospital, Heol Maes Eglwys, Morriston, Swansea, SA6 6NL, United Kingdom
| | - Daniel R Obaid
- Department of Cardiology, Morriston Hospital, Heol Maes Eglwys, Morriston, Swansea, SA6 6NL, United Kingdom.,Swansea University Medical School, Swansea University, Grove Building, Singleton Park, Sketty, Swansea SA2 8PP, United Kingdom
| |
Collapse
|
17
|
Abazid RM, Smettei OA, Almeman A, Sayed S, Alsaqqa H, Abdelmageed SM, Alharbi FJ, Alhabib AM, Al-Mallah MH. Fat volume measurements as a predictor of image noise in coronary computed tomography angiography. J Saudi Heart Assoc 2018; 31:32-40. [PMID: 30559578 PMCID: PMC6289940 DOI: 10.1016/j.jsha.2018.11.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Revised: 08/19/2018] [Accepted: 11/12/2018] [Indexed: 11/16/2022] Open
Abstract
Introduction Image noise can negatively affect the overall quality of coronary computed tomography angiography (CCTA). Objectives The purpose of this study was to evaluate the relationship between image noise and fat volumes in the chest wall. We also aimed to compare these with other patient-specific predictors of image noise, such as body weight (BW) and body mass index (BMI). Methods We undertook a cross-sectional, single-center study. A tube voltage of 100 kV was used for patients with BW <85 kg and 120 kV for BW ≥85 kg. The image noise in the aortic root, single-slice fat volume (SFV) at the level of the left main coronary artery and the total fat volume of the chest (TFV) were analyzed. Results A total of 132 consecutive patients were enrolled (mean age ± standard deviation, 51 ± 11 years; 64% male). The mean image noise was 30.5 ± 11 Hounsfield units (HU). We found that patients with image noise >30 HU had significantly higher SFV (75 ± 33 vs. 51 ± 24, p < 0.0001) and TFV (2206 ± 927 vs. 1815 ± 737, p < 0.01) compared with patients having noise ≤30 HU, whereas BW and BMI showed no significant difference (78 ± 13 vs. 81 ± 14, p < 0.34) and (28.7 ± 4.7 vs. 26.8 ± 3.8, p < 0.19), respectively. Linear regression analysis showed that image noise has better correlation with SFV (R = 0.399; p < 0.0001); and TFV (R = 0, p < 0.009) than BMI (R = 0.154, p < 0.039) and BW (R = -0.102, p = 0.12). Conclusions Fat volume measurements of the chest wall can predict CCTA image noise better than other patient-specific predictors, such as BW and BMI.
Collapse
Affiliation(s)
- Rami M. Abazid
- Department of Cardiology, Cardiac Imaging, Prince Sultan Cardiac Center–Qassim PSCCQ, King Fahad Specialist Hospital, Buraydah, Saudi Arabia
- Corresponding author at: Department of Cardiology, Prince Sultan Cardiac Center–Qassim (PSCCQ), Postal Code 2290, Buraydah, Al-Qassim, Saudi Arabia.
| | - Osama A. Smettei
- Department of Cardiology, Cardiac Imaging, Prince Sultan Cardiac Center–Qassim PSCCQ, King Fahad Specialist Hospital, Buraydah, Saudi Arabia
| | - Ahmad Almeman
- Department of pharmacology, Qassim University, Qassim, Buraydah, Saudi Arabia
| | - Sawsan Sayed
- Department of Cardiology, Cardiac Imaging, Prince Sultan Cardiac Center–Qassim PSCCQ, King Fahad Specialist Hospital, Buraydah, Saudi Arabia
| | - Hanaa Alsaqqa
- Department of Cardiology, Cardiac Imaging, Prince Sultan Cardiac Center–Qassim PSCCQ, King Fahad Specialist Hospital, Buraydah, Saudi Arabia
| | - Salma M. Abdelmageed
- Department of Cardiology, Cardiac Imaging, Prince Sultan Cardiac Center–Qassim PSCCQ, King Fahad Specialist Hospital, Buraydah, Saudi Arabia
| | - Fahad J. Alharbi
- Department of Cardiology, Cardiac Imaging, Prince Sultan Cardiac Center–Qassim PSCCQ, King Fahad Specialist Hospital, Buraydah, Saudi Arabia
| | - Abdullah M. Alhabib
- Department of Cardiology, Cardiac Imaging, Prince Sultan Cardiac Center–Qassim PSCCQ, King Fahad Specialist Hospital, Buraydah, Saudi Arabia
| | - Mouaz H. Al-Mallah
- Department of Medicine, Wayne State University, Detroit, MI, USA
- Cardiac Imaging, King Abdul-Aziz Cardiac Center, National Guard Health Affairs, Riyadh, Saudi Arabia
| |
Collapse
|
18
|
Impact of a New Adaptive Statistical Iterative Reconstruction (ASIR)-V Algorithm on Image Quality in Coronary Computed Tomography Angiography. Acad Radiol 2018; 25:1305-1313. [PMID: 29602723 DOI: 10.1016/j.acra.2018.02.009] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2017] [Revised: 01/28/2018] [Accepted: 02/03/2018] [Indexed: 11/22/2022]
Abstract
RATIONALE AND OBJECTIVES A new postprocessing algorithm named adaptive statistical iterative reconstruction (ASIR)-V has been recently introduced. The aim of this article was to analyze the impact of ASIR-V algorithm on signal, noise, and image quality of coronary computed tomography angiography. MATERIALS AND METHODS Fifty consecutive patients underwent clinically indicated coronary computed tomography angiography (Revolution CT; GE Healthcare, Milwaukee, WI). Images were reconstructed using filtered back projection and ASIR-V 0%, and a combination of filtered back projection and ASIR-V 20%-80% and ASIR-V 100%. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for left main coronary artery (LM), left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA) and were compared between the different postprocessing algorithms used. Similarly a four-point Likert image quality score of coronary segments was graded for each dataset and compared. A cutoff value of P < .05 was considered statistically significant. RESULTS Compared to ASIR-V 0%, ASIR-V 100% demonstrated a significant reduction of image noise in all coronaries (P < .01). Compared to ASIR-V 0%, SNR was significantly higher with ASIR-V 60% in LM (P < .01), LAD (P < .05), LCX (P < .05), and RCA (P < .01). Compared to ASIR-V 0%, CNR for ASIR-V ≥60% was significantly improved in LM (P < .01), LAD (P < .05), and RCA (P < .01), whereas LCX demonstrated a significant improvement with ASIR-V ≥80%. ASIR-V 60% had significantly better Likert image quality scores compared to ASIR-V 0% in segment-, vessel-, and patient-based analyses (P < .01). CONCLUSIONS Reconstruction with ASIR-V 60% provides the optimal balance between image noise, SNR, CNR, and image quality.
Collapse
|
19
|
Annoni AD, Andreini D, Pontone G, Mancini ME, Formenti A, Mushtaq S, Baggiano A, Conte E, Guglielmo M, Muscogiuri G, Muratori M, Fusini L, Trabattoni D, Teruzzi G, Coutinho Santos AI, Agrifoglio M, Pepi M. CT angiography prior to TAVI procedure using third-generation scanner with wide volume coverage: feasibility, renal safety and diagnostic accuracy for coronary tree. Br J Radiol 2018; 91:20180196. [PMID: 30004788 DOI: 10.1259/bjr.20180196] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
OBJECTIVE: To evaluate feasibility, image quality and accuracy of a reduced contrast volume protocol for pre-procedural CT imaging in transcatheter aortic valve implantation (TAVI) using a third generation wide array CT scanner. METHODS: 115 consecutive patients (51F, mean age 82.5 ± 6.2 y, mean BMI 26.7 ± 3.6) referred for TAVI were examined with wide-array CT scanner with a combined scan protocol and a total amount of 50 ml contrast agent. A 4-point visual scale (4-1) was used to assess image quality . Contrast attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries. Coronary tree was assessed and compared with invasive coronary angiography (ICA). Aortic annulus measurements were compared with final procedural results. Patients creatinine was monitored at the baseline and 72 h after procedure. RESULTS: Median quality score value was >3. Mean CNR at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries were 14.8 ± 2.3, 15.7 ± 1.7, 14.9 ± 3.1, 15.8 ± 4.7, 20.3 ± 9.9, 20.8 ± 6.9 respectively. Only 1 patient had moderate paravalvular regurgitation. In comparison with ICA for coronary assessment CTA showed in a segment based analysis sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 97, 85, 99,62 and 88% respectively. Mean creatinine before CT and 72 h after procedure were 1.21 ± 0.52 and1.22 ± 0.49 mg dl-1. Mean DLP was 442.4 ± 21.2 mGy/cm. CONCLUSION: CT with low contrast volume is feasible and clinically useful, allowing precise pre-procedural TAVI planning with accurate assessment of coronary tree. ADVANCES IN KNOWLEDGE: third generation CT scanner with whole heart coverage allows examinations for assessment of aorta and coronary arteries in TAVI planning using low dose of contrast medium maintaining good quality and high diagnostic accuracy.
Collapse
Affiliation(s)
- Andrea D Annoni
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Daniele Andreini
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Gianluca Pontone
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | | | - Alberto Formenti
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Saima Mushtaq
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | | | - Edoardo Conte
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Marco Guglielmo
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Giuseppe Muscogiuri
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Manuela Muratori
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Laura Fusini
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Daniela Trabattoni
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Giovanni Teruzzi
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Ana I Coutinho Santos
- 2 Imaging Department, Centro Hospitalar de Lisboa Ocidental, E.P.E , Lisboa , Portugal
| | - Marco Agrifoglio
- 3 Department of Clinical Sciences and Community Health, University of Milan , Milan , Italy.,4 Cardiac Surgery Department, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| | - Mauro Pepi
- 1 Department of Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS , Milan , Italy
| |
Collapse
|
20
|
Image Quality, Overall Evaluability, and Effective Radiation Dose of Coronary Computed Tomography Angiography With Prospective Electrocardiographic Triggering Plus Intracycle Motion Correction Algorithm in Patients With a Heart Rate Over 65 Beats Per Minute. J Thorac Imaging 2018; 33:225-231. [PMID: 29346192 DOI: 10.1097/rti.0000000000000320] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
PURPOSE Recently, a new intracycle motion correction algorithm (MCA) was introduced to reduce motion artifacts from heart rate (HR) in coronary computed tomography angiography (cCTA). The aim of the study was to evaluate the image quality, overall evaluability, and effective radiation dose (ED) of cCTA with prospective electrocardiographic (ECG) triggering plus MCA as compared with standard protocol with retrospective ECG triggering in patients with HR≥65 bpm. MATERIALS AND METHODS One hundred consecutive patients (67±10 y) scheduled for cCTA with 65<HR<80 bpm were retrospectively analyzed. The patients were assigned to 2 groups undergoing prospective (group 1) or retrospective (group 2) triggered cCTA. The study protocol was approved by the Institutional Ethics Committee and a written informed consent was obtained from all patients. Image noise, signal to noise ratio, contrast to noise ratio, Likert image quality score (score 1, nondiagnostic; score 2, adequate; score 3, good; score 4, excellent), overall image evaluability, and ED were measured and compared between the 2 groups. Both vessel-based and patient-based analyses were evaluated. Student test or Wilcoxon test were used to evaluate differences of continuous variables, whereas the χ test was used to study differences with regard to categorical data. A P-value <0.05 was considered statistically significant. RESULTS cCTA was successfully performed in all patients. In a segment-based model, group 1 compared with group 2 showed a lower rate of overall artifacts (67% vs. 83%; P<0.001) and motion artifacts (49% vs. 66%; P<0.001), resulting in a better Likert image quality score (2.83±1.03 vs. 2.37±1.02; P<0.01) and overall evaluability (85% vs. 75%; P<0.01). Group 1 showed a lower ED as compared with group 2 (3.1±1.9 vs. 11.9±3.3 mSv; P<0.01). CONCLUSION MCA and cCTA with prospective ECG-triggering acquisition in patients with high HR improves image quality and overall evaluability compared with cCTA with standard retrospective ECG triggering.
Collapse
|
21
|
Lee HS, Suh YJ, Han K, Kim JY, Chang S, Im DJ, Hong YJ, Lee HJ, Hur J, Kim YJ, Choi BW. Effectiveness of automatic tube potential selection with tube current modulation in coronary CT angiography for obese patients: Comparison with a body mass index-based protocol using the propensity score matching method. PLoS One 2018; 13:e0190584. [PMID: 29304060 PMCID: PMC5755873 DOI: 10.1371/journal.pone.0190584] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2017] [Accepted: 11/21/2017] [Indexed: 01/09/2023] Open
Abstract
Background Reduced image quality from increased X-ray scatter and image noise can be problematic when coronary computed tomography angiography (CCTA) imaging is performed in obese patients. The aim of this study was to compare the image quality and radiation dose obtained using automatic tube potential selection with tube current modulation (APSCM) with those obtained using a body mass index (BMI)-based protocol for CCTA in obese patients. Methods A total of 203 consecutive obese (BMI > 30 kg/m2) patients were retrospectively enrolled, of whom 96 underwent CCTA with APSCM and 107 underwent a BMI-based protocol. After applying the propensity score matching method, the clinical parameters, subjective and objective image quality, and radiation dose were compared between the APSCM group and the matched BMI-based group. These parameters were also compared among different tube potential subgroups. Results No significant differences were observed between the APSCM group and the BMI-based group with respect to image quality or radiation dose assessment (p > 0.05). Twenty patients (21%) examined with 140 kV in the APSCM group were exposed to significantly more radiation (p < 0.05) than patients in the BMI-based group or patients in the other APSCM kV subgroups; significant improvement in image quality was not observed in the 140 kV subgroup. Patients with a high BMI and a large effective diameter tended to be examined with 140 kV (p < 0.05). Conclusion The use of APSCM for CCTA in obese patients did not significantly reduce the radiation dose or improve image quality compared with those in the matched BMI-based group. Our data indicate that it is better to avoid using APSCM when 140 kV is automatically selected, due to increased radiation dose and lack of significant improvement in image quality.
Collapse
Affiliation(s)
- Hong Seon Lee
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Korea
| | - Young Joo Suh
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Korea
- * E-mail:
| | - Kyunghwa Han
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Korea
| | - Jin Young Kim
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Korea
| | - Suyon Chang
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Korea
| | - Dong Jin Im
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Korea
| | - Yoo Jin Hong
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Korea
| | - Hye-Jeong Lee
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Korea
| | - Jin Hur
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Korea
| | - Young Jin Kim
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Korea
| | - Byoung Wook Choi
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Korea
| |
Collapse
|
22
|
Si-Mohamed S, Greffier J, Bobbia X, Larbi A, Delicque J, Khasanova E, Beregi JP, Macri F. Diagnostic performance of a low dose triple rule-out CT angiography using SAFIRE in emergency department. Diagn Interv Imaging 2017; 98:881-891. [DOI: 10.1016/j.diii.2017.09.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 08/07/2017] [Accepted: 09/07/2017] [Indexed: 12/13/2022]
|
23
|
|
24
|
Shirota G, Maeda E, Namiki Y, Bari R, Ino K, Torigoe R, Abe O. Pediatric 320-row cardiac computed tomography using electrocardiogram-gated model-based full iterative reconstruction. Pediatr Radiol 2017; 47:1463-1470. [PMID: 28667349 PMCID: PMC5608791 DOI: 10.1007/s00247-017-3901-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Revised: 04/05/2017] [Accepted: 05/09/2017] [Indexed: 12/03/2022]
Abstract
BACKGROUND Full iterative reconstruction algorithm is available, but its diagnostic quality in pediatric cardiac CT is unknown. OBJECTIVE To compare the imaging quality of two algorithms, full and hybrid iterative reconstruction, in pediatric cardiac CT. MATERIALS AND METHODS We included 49 children with congenital cardiac anomalies who underwent cardiac CT. We compared quality of images reconstructed using the two algorithms (full and hybrid iterative reconstruction) based on a 3-point scale for the delineation of the following anatomical structures: atrial septum, ventricular septum, right atrium, right ventricle, left atrium, left ventricle, main pulmonary artery, ascending aorta, aortic arch including the patent ductus arteriosus, descending aorta, right coronary artery and left main trunk. We evaluated beam-hardening artifacts from contrast-enhancement material using a 3-point scale, and we evaluated the overall image quality using a 5-point scale. We also compared image noise, signal-to-noise ratio and contrast-to-noise ratio between the algorithms. RESULTS The overall image quality was significantly higher with full iterative reconstruction than with hybrid iterative reconstruction (3.67±0.79 vs. 3.31±0.89, P=0.0072). The evaluation scores for most of the gross structures were higher with full iterative reconstruction than with hybrid iterative reconstruction. There was no significant difference between full and hybrid iterative reconstruction for the presence of beam-hardening artifacts. Image noise was significantly lower in full iterative reconstruction, while signal-to-noise ratio and contrast-to-noise ratio were significantly higher in full iterative reconstruction. CONCLUSION The diagnostic quality was superior in images with cardiac CT reconstructed with electrocardiogram-gated full iterative reconstruction.
Collapse
Affiliation(s)
- Go Shirota
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
| | - Eriko Maeda
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan
| | - Yoko Namiki
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan
| | - Razibul Bari
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan
| | - Kenji Ino
- Imaging Center, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan
| | - Rumiko Torigoe
- Toshiba Medical Systems, 2-1-6, Tsukuda, Chuo-ku, Tokyo, 104-0051 Japan
| | - Osamu Abe
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655 Japan
| |
Collapse
|
25
|
Low-Voltage, High-Pitch Computerized Tomography Angiography of the Infrarenal Aorta and Lower Extremity Vessels: Assessment of Radiation Dose, Image Quality With Hybrid Iterative Reconstruction, and Efficacy of Test Injection Using a Monitoring Scan at Knee Level. J Comput Assist Tomogr 2016; 40:402-8. [PMID: 26854413 DOI: 10.1097/rct.0000000000000365] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Our aim was to assess image quality and radiation dose of low-voltage high-pitch computed tomography angiography of the infrarenal aorta and lower extremities and evaluate the efficacy of test injection technique using a monitoring scan at knee level. METHODS A total of 60 patients with suspected peripheral arterial disease were divided into 2 groups: group 1 (30 patients, 80 kVp, high pitch [3.2], and hybrid iterative reconstruction [sinogram-affirmed iterative reconstruction]) and group 2 (30 patients, 120 kVp, low pitch [1.0], and filtered back projection reconstruction). The test injection technique at knee level was used to determine the scan delay time in group 1. The image quality and radiation exposure were compared. RESULTS There were significant differences between the 2 groups in mean (SD) arterial attenuation (80 vs 120 kVp: 507.78 [103.01] vs 317.54 [62.03] Hounsfield units, P < 0.001), mean (SD) signal-to-noise ratio (51.04 [20.29] vs 34.66 [9.94], P < 0.001), and contrast-to-noise ratio (44.83 [17.93] vs 28.26 [9.60], P < 0.001). No difference in subjective image quality was found between the 2 groups (all P > 0.05). The imaging time was significantly shorter in group 1 (2.70 [0.11] vs 14.65 [0.90s], P < 0.001). The mean (SD) effective dose was significantly lower in the 80 kVp group (0.76 [0.06] vs 4.29 [0.63] mSv, P < 0.001). CONCLUSIONS The 80-kVp high-pitch computed tomography angiography of the lower limbs using sinogram-affirmed iterative reconstruction yields reduction of radiation exposure as well as obtains acceptable image quality if acquisition protocols are used in conjunction with the test injection technique using monitoring scan at knee level to determine the delay time.
Collapse
|
26
|
Dyakov I, Stoinova V, Groudeva V, Vassileva J. The influence of novel CT reconstruction technique and ECG-gated technique on image quality and patient dose of cardiac computed tomography. RADIATION PROTECTION DOSIMETRY 2015; 165:182-184. [PMID: 25836680 DOI: 10.1093/rpd/ncv114] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The aim of the present study was to compare image quality and patient dose in cardiac computed tomography angiography (CTA) in terms of volume computed tomography dose index (CTDI vol), dose length product (DLP) and effective dose, when changing from filtered back projection (FBP) to adaptive iterative dose reduction (AIDR) reconstruction techniques. Further aim was to implement prospective electrocardiogram (ECG) gating for patient dose reduction. The study was performed with Aquilion ONE 320-row CT of Toshiba Medical Systems. Analysis of cardiac CT protocols was performed before and after integration of the new software. The AIDR technique showed more than 50 % reduction in CTDIvol values and 57 % in effective dose. The subjective evaluation of clinical images confirmed the adequate image quality acquired by the AIDR technique. The preliminary results indicated significant dose reduction when using prospective ECG gating by keeping the adequate diagnostic quality of clinical images.
Collapse
Affiliation(s)
- I Dyakov
- National Centre of Radiobiology and Radiation Protection, Sofia, Bulgaria
| | - V Stoinova
- University Hospital St. Ekaterina, Sofia, Bulgaria
| | - V Groudeva
- University Hospital St. Ekaterina, Sofia, Bulgaria
| | - J Vassileva
- National Centre of Radiobiology and Radiation Protection, Sofia, Bulgaria
| |
Collapse
|
27
|
Litmanovich DE, Tack DM, Shahrzad M, Bankier AA. Dose reduction in cardiothoracic CT: review of currently available methods. Radiographics 2015; 34:1469-89. [PMID: 25310412 DOI: 10.1148/rg.346140084] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Radiation exposure from computed tomography (CT) has received much attention lately in the medical literature and the media, given the relatively high radiation dose that characterizes a CT examination. Although there are a variety of possible strategies for reducing radiation exposure from CT in an individual patient, optimal CT image acquisition requires that the radiologist understand new scanner technology and how to implement the most effective means of dose reduction while maintaining image quality. The authors describe a practical approach to dose reduction in cardiothoracic radiology, discussing CT radiation dose metrics (eg, CT dose index, dose-length product, effective diameter, and size-specific dose estimate) as well as CT scanner parameters that directly or indirectly influence radiation dose (eg, scan length, x-ray tube output, tube current modulation, pitch, image reconstruction techniques [including iterative reconstruction], and noise reduction). These variables are discussed in terms of their relative importance to image quality and the implications of parametric changes for image quality and diagnostic content, and practical recommendations are made for their immediate implementation in the clinical setting. Taken together, the principles of physics and key parameters involved in reducing radiation dose while maintaining image quality can serve as a "survival guide" for a diagnostic radiology practice.
Collapse
Affiliation(s)
- Diana E Litmanovich
- From the Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave, Shapiro 4, Boston, MA 02215 (D.E.L., M.S., A.A.B.); and Department of Radiology, Epicura Hospital, Baudour, Belgium (D.M.T.)
| | | | | | | |
Collapse
|
28
|
Non-invasive prediction of hemodynamically significant coronary artery stenoses by contrast density difference in coronary CT angiography. Eur J Radiol 2015; 84:1502-1508. [PMID: 26001435 DOI: 10.1016/j.ejrad.2015.04.024] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2014] [Revised: 02/19/2015] [Accepted: 04/24/2015] [Indexed: 01/28/2023]
Abstract
OBJECTIVES Coronary computed tomography angiography (CTA) allows the detection of obstructive coronary artery disease. However, its ability to predict the hemodynamic significance of stenoses is limited. We assessed differences in plaque characteristics and contrast density difference between hemodynamically significant and non-significant stenoses, as defined by invasive fractional flow reserve (FFR). METHODS Lesion characteristics of 59 consecutive patients (72 lesions) in whom invasive FFR was performed in at least one coronary artery with moderate to high-grade stenoses in coronary CTA were evaluated by two experienced readers. Coronary CTA data sets were acquired on a second-generation dual-source CT scanner using retrospectively ECG-gated spiral acquisition or prospectively ECG-triggered axial acquisition mode. Plaque volume and composition (non-calcified, calcified), remodeling index as well as contrast density difference (defined as the percentage decline in luminal CT attenuation/cross-sectional area over the lesion) were assessed using a semi-automatic software tool (Autoplaq). Additionally, the transluminal attenuation gradient (defined as the linear regression coefficient between intraluminal CT attenuation and length from the ostium) was determined. Differences in lesion characteristics between hemodynamically significant (invasively measured FFR ≤0.80) and non-significant lesions (FFR >0.80) were determined. RESULTS Mean patient age was 64±11 years with 44 males (75%). 21 out of 72 coronary artery lesions (29%) were hemodynamically significant according to invasive FFR. Mean invasive FFR was 0.66±0.12 vs. 0.91±0.05 for hemodynamically significant versus non-significant lesions. Hemodynamically significant lesions showed a significantly greater percentage of non-calcified plaque compared to non-hemodynamically relevant lesions (51.3±15.3% vs. 43.6±16.5%, p=0.021). Contrast density difference was significantly increased in hemodynamically relevant lesions (26.0±20.2% vs. 16.6±10.9% for non-significant lesions; p=0.013). At a threshold of ≥24%, the contrast density difference predicted hemodynamically significant lesions with a specificity of 75%, sensitivity of 33%, PPV of 35% and NPV of 73%. The transluminal attenuation gradient showed no significant difference between hemodynamically significant and non-significant lesions (-1.4±1.4HU/mm vs. -1.1±1.3HU/mm, p=n.s.). CONCLUSIONS Quantitative contrast density difference across coronary lesions in coronary CTA data sets may be applied as a non-invasive tool to identify hemodynamically significant stenoses.
Collapse
|
29
|
Impact of an intra-cycle motion correction algorithm on overall evaluability and diagnostic accuracy of computed tomography coronary angiography. Eur Radiol 2015; 26:147-56. [PMID: 25953001 DOI: 10.1007/s00330-015-3793-1] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2014] [Revised: 03/15/2015] [Accepted: 04/13/2015] [Indexed: 10/23/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate the impact of a novel intra-cycle motion correction algorithm (MCA) on overall evaluability and diagnostic accuracy of cardiac computed tomography coronary angiography (CCT). METHODS From a cohort of 900 consecutive patients referred for CCT for suspected coronary artery disease (CAD), we enrolled 160 (18 %) patients (mean age 65.3 ± 11.7 years, 101 male) with at least one coronary segment classified as non-evaluable for motion artefacts. The CCT data sets were evaluated using a standard reconstruction algorithm (SRA) and MCA and compared in terms of subjective image quality, evaluability and diagnostic accuracy. RESULTS The mean heart rate during the examination was 68.3 ± 9.4 bpm. The MCA showed a higher Likert score (3.1 ± 0.9 vs. 2.5 ± 1.1, p < 0.001) and evaluability (94%vs.79 %, p < 0.001) than the SRA. In a 45-patient subgroup studied by clinically indicated invasive coronary angiography, specificity, positive predictive value and accuracy were higher in MCA vs. SRA in segment-based and vessel-based models, respectively (87%vs.73 %, 50%vs.34 %, 85%vs.73 %, p < 0.001 and 62%vs.28 %, 66%vs.51 % and 75%vs.57 %, p < 0.001). In a patient-based model, MCA showed higher accuracy vs. SCA (93%vs.76 %, p < 0.05). CONCLUSIONS MCA can significantly improve subjective image quality, overall evaluability and diagnostic accuracy of CCT. KEY POINTS Cardiac computed tomographic coronary angiography (CCT) allows non-invasive evaluation of coronary arteries. Intra-cycle motion correction algorithm (MCA) allows for compensation of coronary motion. An MCA improves image quality, CCT evaluability and diagnostic accuracy.
Collapse
|
30
|
Application of low tube voltage coronary CT angiography with low-dose iodine contrast agent in patients with a BMI of 26–30 kg/m2. Clin Radiol 2015; 70:138-45. [PMID: 25468636 DOI: 10.1016/j.crad.2014.10.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2014] [Revised: 09/26/2014] [Accepted: 10/08/2014] [Indexed: 10/24/2022]
|
31
|
Lu C, Wang Z, Ji J, Wang H, Hu X, Chen C. Evaluation of a chest circumference-adapted protocol for low-dose 128-slice coronary CT angiography with prospective electrocardiogram triggering. Korean J Radiol 2015; 16:13-20. [PMID: 25598671 PMCID: PMC4296260 DOI: 10.3348/kjr.2015.16.1.13] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2014] [Accepted: 11/10/2014] [Indexed: 01/16/2023] Open
Abstract
Objective To assess the effect of chest circumference-adapted scanning protocol on radiation exposure and image quality in patients undergoing prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). Materials and Methods One hundred-eighty-five consecutive patients, who had undergone prospective ECG triggering CCTA with a 128-slice CT, were included in the present study. Nipple-level chest circumference, body weight and height were measured before CT examinations. Patients were divided into four groups based on kV/ref·mAs = 100/200, 100/250, 120/200, and 120/250, when patient's chest circumference was ≤ 85.0 (n = 56), 85.0-90.0 (n = 53), 90.0-95.0 (n = 44), and > 95.0 (n = 32), respectively. Image quality per-segment was independently assessed by two experienced observers. Image noise and attenuation were also measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The effective radiation dose was calculated using CT dose volume index and the dose-length product. Results A significant correlation was observed between patients' chest circumference and body mass index (r = 0.762, p < 0.001). Chest circumference ranged from 74 to 105 cm, and the mean effective radiation dose was 1.9-3.8 mSv. Diagnostic image quality was obtained in 98.5% (2440/2478) of all evaluated coronary segments without any significant differences among the four groups (p = 0.650). No significant difference in image noise was observed among the four groups (p = 0.439), thus supporting the validity of the chest circumference-adapted scanning protocol. However, vessel attenuation, SNR and CNR were significantly higher in the 100 kV groups than in the 120 kV groups (p < 0.05). Conclusion A measure of chest circumference can be used to adapt tube voltage and current for individualized radiation dose control, with resultant similar image noise and sustained diagnostic image quality.
Collapse
Affiliation(s)
- Chenying Lu
- Department of Radiology, Lishui Central Hospital, The Fifth Affiliated Hospital of Wenzhou Medical College, Lishui, Zhejiang 323000, China
| | - Zufei Wang
- Department of Radiology, Lishui Central Hospital, The Fifth Affiliated Hospital of Wenzhou Medical College, Lishui, Zhejiang 323000, China
| | - Jiansong Ji
- Department of Radiology, Lishui Central Hospital, The Fifth Affiliated Hospital of Wenzhou Medical College, Lishui, Zhejiang 323000, China
| | - Hailin Wang
- Department of Radiology, Lishui Central Hospital, The Fifth Affiliated Hospital of Wenzhou Medical College, Lishui, Zhejiang 323000, China
| | - Xianghua Hu
- Department of Radiology, Lishui Central Hospital, The Fifth Affiliated Hospital of Wenzhou Medical College, Lishui, Zhejiang 323000, China
| | - Chunmiao Chen
- Department of Radiology, Lishui Central Hospital, The Fifth Affiliated Hospital of Wenzhou Medical College, Lishui, Zhejiang 323000, China
| |
Collapse
|
32
|
Hell MM, Bittner D, Schuhbaeck A, Muschiol G, Brand M, Lell M, Uder M, Achenbach S, Marwan M. Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: feasibility, image quality, radiation dose, and effect of iterative reconstruction. J Cardiovasc Comput Tomogr 2014; 8:418-25. [PMID: 25439789 DOI: 10.1016/j.jcct.2014.09.003] [Citation(s) in RCA: 70] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Revised: 08/28/2014] [Accepted: 09/03/2014] [Indexed: 12/16/2022]
Abstract
BACKGROUND Low tube voltage reduces radiation exposure in coronary CT angiography (CTA). Using 70 kVp tube potential has so far not been possible because CT systems were unable to provide sufficiently high tube current with low voltage. OBJECTIVE We evaluated feasibility, image quality (IQ), and radiation dose of coronary CTA using a third-generation dual-source CT system capable of producing 450 mAs tube current at 70 kVp tube voltage. METHODS Coronary CTA was performed in 26 consecutive patients with suspected coronary artery disease, selected for body weight <100 kg and heart rate <60 beats/min. High-pitch spiral acquisition was used. Filtered back projection (FBP) and iterative reconstruction (IR) algorithms were applied. IQ was assessed using a 4-point rating scale (1 = excellent, 4 = nondiagnostic) and objective parameters. RESULTS Mean age was 62 ± 9 years (46% males; mean body mass index, 27.7 ± 3.8 kg/m(2); mean heart rate, 54 ± 5 beats/min). Mean dose-length product was 20.6 ± 1.9 mGy × cm; mean estimated effective radiation dose was 0.3 ± 0.03 mSv. Diagnostic IQ was found in 365 of 367 (FBP) and 366 of 367 (IR) segments (P nonsignificant). IQ was rated "excellent" in 53% (FBP) and 86% (IR) segments (P = .001) and "nondiagnostic" in 2 (FBP) and 1 segment (IR) (P nonsignificant). Mean IQ score was lesser in FBP vs IR (1.5 ± 0.4 vs 1.1 ± 0.2; P < .001). Image noise was lower in IR vs FBP (60 ± 10 HU vs 74 ± 8 HU; P < .001). CONCLUSION In patients <100 kg and with a regular heart rate <60 beats/min, third-generation dual-source CT using high-pitch spiral acquisition and 70 kVp tube voltage is feasible and provides both robust IQ and very low radiation exposure.
Collapse
Affiliation(s)
- Michaela M Hell
- Department of Cardiology, University of Erlangen, Erlangen, Germany.
| | - Daniel Bittner
- Department of Cardiology, University of Erlangen, Erlangen, Germany
| | | | - Gerd Muschiol
- Department of Cardiology, University of Erlangen, Erlangen, Germany
| | - Michael Brand
- Department of Radiology, University of Erlangen, Erlangen, Germany
| | - Michael Lell
- Department of Radiology, University of Erlangen, Erlangen, Germany
| | - Michael Uder
- Department of Radiology, University of Erlangen, Erlangen, Germany
| | | | - Mohamed Marwan
- Department of Cardiology, University of Erlangen, Erlangen, Germany
| |
Collapse
|
33
|
Penzkofer T, Donandt E, Isfort P, Allmendinger T, Kuhl CK, Mahnken AH, Bruners P. Influence of trigger type, tube voltage and heart rate on calcified plaque imaging in dual source cardiac computed tomography: phantom study. BMC Med Imaging 2014; 14:30. [PMID: 25178653 PMCID: PMC4174388 DOI: 10.1186/1471-2342-14-30] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2013] [Accepted: 08/03/2014] [Indexed: 11/10/2022] Open
Abstract
Background To investigate the impact of high pitch cardiac CT vs. retrospective ECG gated CT on the quantification of calcified vessel stenoses, with assessment of the influence of tube voltage, reconstruction kernel and heart rate. Methods A 4D cardiac movement phantom equipped with three different plaque phantoms (12.5%, 25% and 50% stenosis at different calcification levels), was scanned with a 128-row dual source CT scanner, applying different trigger types (gated vs. prospectively triggered high pitch), tube voltages (100-120 kV) and heart rates (50–90 beats per minute, bpm). Images were reconstructed using different standard (B26f, B46f, B70f) and iterative (I26f, I70f) convolution kernels. Absolute and relative plaque sizes were measured and statistically compared. Radiation dose associated with the different methods (gated vs. high pitch, 100 kV vs. 120 kV) were compared. Results Compared to the known diameters of the phantom plaques and vessels both CT-examination techniques overestimated the degrees of stenoses. Using the high pitch CT-protocol plaques appeared larger (0.09 ± 0.31 mm, 2 ± 8 percent points, PP) in comparison to the ECG-gated CT-scans. Reducing tube voltage had a similar effect, resulting in higher grading of the same stenoses by 3 ± 8 PP. In turn, sharper convolution kernels lead to a lower grading of stenoses (differences of up to 5%). Pairwise comparison of B26f and I26f, B46f and B70f, and B70f and I70f showed differences of 0–1 ± 6–8 PP of the plaque depiction. Motion artifacts were present only at 90 bpm high pitch experiments. High-pitch protocols were associated with significantly lower radiation doses compared with the ECG-gated protocols (258.0 mGy vs. 2829.8 mGy CTDIvol, p ≤ 0.0001). Conclusion Prospectively triggered high-pitch cardiac CT led to an overestimation of plaque diameter and degree of stenoses in a coronary phantom. This overestimation is only slight and probably negligible in a clinical situation. Even at higher heart rates high pitch CT-scanning allowed reliable measurements of plaque and vessel diameters with only slight differences compared ECG-gated protocols, although motion artifacts were present at 90 bpm using the high pitch protocols.
Collapse
Affiliation(s)
- Tobias Penzkofer
- Department of Diagnostic and Interventional Radiology, Aachen University Hospital, RWTH Aachen University, Pauwelsstr, 30, 52074 Aachen, Germany.
| | | | | | | | | | | | | |
Collapse
|
34
|
Kim SM, Cho YK, Choe YH. Adenosine-stress dynamic myocardial perfusion imaging using 128-slice dual-source CT in patients with normal body mass indices: effect of tube voltage, tube current, and iodine concentration on image quality and radiation dose. Int J Cardiovasc Imaging 2014; 30 Suppl 2:95-103. [PMID: 25156692 DOI: 10.1007/s10554-014-0524-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2014] [Accepted: 08/15/2014] [Indexed: 10/24/2022]
Abstract
The aim of this study was to evaluate the image quality and radiation dose in adenosine-stress dynamic myocardial CT perfusion (CTP) imaging using different tube voltages, tube current settings, and contrast materials containing different iodine concentrations in subjects with normal body mass indices (BMI). We included 92 patients (BMI range, 18.5-24.8) who underwent dynamic CTP for the evaluation of coronary artery disease using a 128-slice dual-source computed tomography. The protocols employed the following dynamic scan parameters: protocol I with 100 kV, fixed tube current (FTC), and medium-concentration contrast material (MC, 350 mg iodine/mL); protocol II with 100 kV, automatic tube current modulation (ATCM), and MC; protocol III with 100 kV, ATCM, and high-concentration contrast material (HC, 400 mg iodine/mL); protocol IV with 80 kV, adopted FTC, and HC. Subjective image quality on a 1-3 point scale and objective image quality with respect to the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were assessed. Protocol IV showed higher CNR and SNR than the other protocols (P < 0.01), while the CNR and SNR values did not significantly differ among the other three protocols. There was no significant difference in subjective image quality among the protocols. The radiation dose in protocol IV was the lowest among the protocols (P < 0.01), while protocol IV resulted in a 54% overall reduction in mean effective radiation dose compared with protocol I. Dynamic myocardial CTP performed at 80 kV with adapted FTC provided high CNR and SNR while preserving subjective image quality and reducing radiation exposure.
Collapse
Affiliation(s)
- Sung Mok Kim
- Department of Radiology and Cardiovascular Imaging Center, Cardiac and Vascular Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Ilwon-ro, Gangnam-gu, Seoul, 135-710, Korea
| | | | | |
Collapse
|
35
|
Correlation between low tube voltage in dual source CT coronary artery imaging with image quality and radiation dose. ACTA ACUST UNITED AC 2014; 34:616-620. [PMID: 25135738 DOI: 10.1007/s11596-014-1326-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2013] [Revised: 04/16/2014] [Indexed: 01/12/2023]
Abstract
The influence of low tube voltage in dual source CT (DSCT) coronary artery imaging on image quality and radiation dose and its application value in clinical practice were investigated. Totally, 300 cases of chest pain with low body mass index (BMI <18.5 kg/m(2)) subjected to DSCT coronary artery imaging were prospectively enrolled. The heart rate in all patients were greater than 65/min. The retrospective ECG gated scanning mode and simple random sampling method were used to assign the patients into groups A, B and C (n=100 each). The patients in groups A, B and C experienced 120-, 100-, and 80-kV tube voltage imaging respectively, and the image quality was evaluated. The CT volume dose index (CTDIvol) and dose length product (DLP) were recorded, and the effective dose (ED) was calculated in each group. The image quality scores and radiation doses in groups were compared, and the influence of tube voltage on image quality and radiation dose was analyzed. The results showed that the excellent rate of image quality in groups A, B and C was 95.69%, 94.72% and 96.33% respectively with the difference being not statistically significant among the three groups (P>0.05). The CTDIvol values in groups A, B and C were 51.35±12.21, 21.28±7.13 and 6.34±3.34 mGy, respectively, with the difference being statistically significant (P<0.05). The ED values in groups A, B and C were 9.27±1.63, 4.56±2.29 and 2.29±1.69 mSv, respectively, with the difference being statistically significant (P<0.05). It was suggested that for the patients with low BMI, the application of DSCT coronary artery imaging with low tube voltage can obtain satisfactory image quality, and simultaneously, significantly reduce the radiation dose.
Collapse
|
36
|
Layritz C, Schmid J, Achenbach S, Ulzheimer S, Wuest W, May M, Ropers D, Klinghammer L, Daniel WG, Pflederer T, Lell M. Accuracy of prospectively ECG-triggered very low-dose coronary dual-source CT angiography using iterative reconstruction for the detection of coronary artery stenosis: comparison with invasive catheterization. Eur Heart J Cardiovasc Imaging 2014; 15:1238-45. [DOI: 10.1093/ehjci/jeu113] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
37
|
Ultra-low contrast computed tomographic angiography (CTA) with 20-mL total dose for transcatheter aortic valve implantation (TAVI) planning. J Comput Assist Tomogr 2014; 38:105-9. [PMID: 24378883 DOI: 10.1097/rct.0b013e3182a14358] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Transcatheter aortic valve implantation workup includes assessment of the aorta and the iliofemoral arteries by computed tomographic angiography. An important group of transcatheter aortic valve implantation candidates have severe renal failure. We tested a novel computed tomographic angiography protocol (128-detector-row dual-source scanner, high-pitch helical mode) with ultralow contrast volume (20 mL) in 8 patients, compared with 8 controls. Contrast-to-noise ratio and subjective image quality, albeit lower than in the controls, were suitable for interpretation in the ultralow contrast volume group throughout all measured locations.
Collapse
|
38
|
Pontone G, Bertella E, Mushtaq S, Loguercio M, Cortinovis S, Baggiano A, Conte E, Annoni A, Formenti A, Beltrama V, Guaricci AI, Andreini D. Coronary artery disease: diagnostic accuracy of CT coronary angiography--a comparison of high and standard spatial resolution scanning. Radiology 2014; 271:688-94. [PMID: 24520943 DOI: 10.1148/radiol.13130909] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
PURPOSE To compare the image quality, evaluability, diagnostic accuracy, and radiation exposure of high-spatial-resolution (HR, 0.23-mm) computed tomographic (CT) coronary angiography with standard spatial resolution (SR, 0.625-mm) 64-section imaging in patients at high risk for coronary artery disease (CAD) by using invasive coronary angiography (ICA) as the reference method. MATERIALS AND METHODS Written informed consent was obtained from all patients, and the study protocol was approved by the institutional ethical committee. Patients at high risk for CAD (n = 184) who were scheduled for ICA were randomly assigned for study with SR (n = 91) or HR (n = 93) coronary CT angiography before they underwent ICA. To compare the two groups, the Student t test or Wilcoxon test were used to evaluate differences in continuous variables. The χ(2) test or Fisher exact test were used, as appropriate, for categorical data. The McNemar test was used to compare the diagnostic performance of coronary CT angiography versus that of ICA in each group. RESULTS HR coronary CT angiography showed a higher image quality score (3.7 vs 3.4, P < .001) and evaluability (97% vs 92%, P < .002). In a segment-based analysis, HR coronary CT angiography showed a higher specificity, positive predictive value, and accuracy in comparison with SR coronary CT angiography (98%, 91%, and 99% vs 95%, 80%, and 95%, respectively; P < .001). Moreover, HR coronary CT angiography showed a better agreement with ICA for calcified plaques compared with SR coronary CT angiography and ICA (83% vs 53%, P < .001). In a patient-based analysis, HR coronary CT angiography showed higher specificity and accuracy compared with SR coronary CT angiography (91% and 98% vs 46% and 92%, respectively; P < .01). No differences in radiation exposure were found between the two groups. CONCLUSION Improved evaluability and accuracy were seen with HR compared with SR coronary CT angiography of calcified coronary artery lesions, suggesting a potential use for this technology in patients at high risk for CAD.
Collapse
Affiliation(s)
- Gianluca Pontone
- From the Centro Cardiologico Monzino, IRCCS, Via C. Parea 4, 20138 Milan, Italy (G.P., E.B., S.M., M.L., S.C., A.B., E.C., A.A., A.F., V.B., D.A.); Department of Cardiology, University of Foggia, Foggia, Italy (A.I.G.); and Department of Cardiovascular Sciences and Community Health, University of Milan, Milan, Italy (D.A.)
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
39
|
Cao JX, Wang YM, Lu JG, Zhang Y, Wang P, Yang C. Radiation and contrast agent doses reductions by using 80-kV tube voltage in coronary computed tomographic angiography: A comparative study. Eur J Radiol 2014; 83:309-14. [DOI: 10.1016/j.ejrad.2013.06.032] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2013] [Revised: 06/10/2013] [Accepted: 06/17/2013] [Indexed: 02/04/2023]
|
40
|
Sarapata A, Stayman JW, Finkenthal M, Siewerdsen JH, Pfeiffer F, Stutman D. High energy x-ray phase contrast CT using glancing-angle grating interferometers. Med Phys 2014; 41:021904. [PMID: 24506625 PMCID: PMC3981561 DOI: 10.1118/1.4860275] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2013] [Revised: 12/10/2013] [Accepted: 12/17/2013] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. METHODS DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. RESULTS Using a glancing angle interferometer at high x-ray energy (∼ 45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. CONCLUSIONS DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.
Collapse
Affiliation(s)
- A Sarapata
- Department of Physics and Astronomy, Johns Hopkins University, Baltimore, Maryland 21218 and Department of Physics and Institute of Medical Engineering, Technische Universität München, 85748 Garching, Germany
| | - J W Stayman
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21218
| | - M Finkenthal
- Department of Physics and Astronomy, Johns Hopkins University, Baltimore, Maryland 21218
| | - J H Siewerdsen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21218
| | - F Pfeiffer
- Department of Physics and Institute of Medical Engineering, Technische Universität München, 85748 Garching, Germany
| | - D Stutman
- Department of Physics and Astronomy, Johns Hopkins University, Baltimore, Maryland 21218
| |
Collapse
|
41
|
Coronary CT angiography with iterative reconstruction in early triage of patients with acute chest pain. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2013. [DOI: 10.1016/j.ejrnm.2013.07.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
42
|
Gimelli A, Coceani M. State of the Art Hybrid Technology: SPECT/CT. CURRENT CARDIOVASCULAR IMAGING REPORTS 2013. [DOI: 10.1007/s12410-013-9205-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
43
|
Maluenda G, Goldstein MA, Weissman G, Weigold WG, Desai MY, Taylor AJ. The Role of Cardiac CT Prior to Reoperative Cardiac Surgery. CURRENT CARDIOVASCULAR IMAGING REPORTS 2013. [DOI: 10.1007/s12410-013-9202-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
44
|
A Community Hospital's Experience With an Effective, Affordable, and Easily Implemented CT Radiation Dose Reduction Initiative. J Am Coll Radiol 2013; 10:378-80. [DOI: 10.1016/j.jacr.2012.10.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2012] [Accepted: 10/03/2012] [Indexed: 11/23/2022]
|
45
|
Computed tomography to diagnose coronary artery disease: A reduction in radiation dose increases applicability. Clin Radiol 2013; 68:340-5. [DOI: 10.1016/j.crad.2012.05.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2012] [Revised: 05/07/2012] [Accepted: 05/17/2012] [Indexed: 11/20/2022]
|
46
|
Hou Y, Zheng J, Wang Y, Yu M, Vembar M, Guo Q. Optimizing radiation dose levels in prospectively electrocardiogram-triggered coronary computed tomography angiography using iterative reconstruction techniques: a phantom and patient study. PLoS One 2013; 8:e56295. [PMID: 23437110 PMCID: PMC3577795 DOI: 10.1371/journal.pone.0056295] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2012] [Accepted: 01/07/2013] [Indexed: 11/18/2022] Open
Abstract
Aim To investigate the potential of reducing the radiation dose in prospectively electrocardiogram-triggered coronary computed tomography angiography (CCTA) while maintaining diagnostic image quality using an iterative reconstruction technique (IRT). Methods and Materials Prospectively-gated CCTA were first performed on a phantom using 256-slice multi-detector CT scanner at 120 kVp, with the tube output gradually reduced from 210 mAs (Group A) to 125, 105, 84, and 63 mAs (Group B–E). All scans were reconstructed using filtered back projection (FBP) algorithm and five IRT levels (L2-6), image quality (IQ) assessment was performed. Based on the IQ assessment, Group D(120 kVp, 84 mAs) reconstructed with L5 was found to provide IQ comparable to that of Group A with FBP. In the patient study, 21 patients underwent CCTA using 120 kV, 210 mAs with FBP reconstruction (Group 1) followed by 36 patients scanned with 120 kV, 84 mAs with IRT L5 (Group 2). Subjective and objective IQ and effective radiation dose were compared between two groups. Results In the phantom scans, there were no significant differences in image noise, contrast-to-noise ratio (CNR) and modulation transfer function (MTF) curves between Group A and the 84 mAs, 63 mAs groups (Groups D and E). Group D (120 kV, 84 mAs and L5) provided an optimum balance, producing equivalent image quality to Group A, at the lowest possible radiation dose. In the patient study, there were no significant difference in image noise, signal-to-noise ratio (SNR) and CNR between Group 1 and Group 2 (p = 0.71, 0.31, 0.5, respectively). The effective radiation dose in Group 2 was 1.21±0.14 mSv compared to 3.20±0.58 mSv (Group 1), reflecting dose savings of 62.5% (p<0.05). Conclusion iterative reconstruction technique used in prospectively ECG-triggered 256-slice coronary CTA can provide radiation dose reductions of up to 62.5% with acceptable image quality.
Collapse
Affiliation(s)
- Yang Hou
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Jiahe Zheng
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Yuke Wang
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Mei Yu
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Mani Vembar
- CT Clinical Science Philips Healthcare, Cleveland, Ohio, United States of America
| | - Qiyong Guo
- Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China
- * E-mail:
| |
Collapse
|
47
|
Abstract
OBJECTIVE Various applications for dual-energy CT (DECT) have been investigated and have shown substantial clinical benefits. However, only limited data are available regarding the radiation dose associated with DECT imaging. The purpose of this article is to review the available literature regarding the radiation dose associated with DECT imaging applications in comparison with conventional single-energy CT techniques. CONCLUSION The rediscovery of DECT and the increasing availability of this technique on clinical CT systems have opened new dimensions for CT. The advanced spectral differentiation of materials within the human body as well as the selective visualization or subtraction of iodinated contrast material or xenon provides both advanced visualization of disease-specific molecular substrates as well as additional functional information within a single scan.
Collapse
|
48
|
Patient-specific predictors of image noise in coronary CT angiography. J Cardiovasc Comput Tomogr 2013; 7:39-45. [DOI: 10.1016/j.jcct.2012.10.011] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2012] [Revised: 08/02/2012] [Accepted: 10/05/2012] [Indexed: 01/23/2023]
|
49
|
Xia Y, Junjie Y, Ying Z, Bai H, Qi W, Qinhua J, Yundai C. Accuracy of 128-slice dual-source CT using high-pitch spiral mode for the assessment of coronary stents: first in vivo experience. Eur J Radiol 2012; 82:617-22. [PMID: 23265926 DOI: 10.1016/j.ejrad.2012.11.033] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2012] [Revised: 10/18/2012] [Accepted: 11/14/2012] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To investigate the accuracy of 128-slice dual-source CT using high-pitch spiral mode (HPS) for the assessment of coronary stents. METHODS We conducted a prospective study on patients with previous stent implantation due to recurred suspicious symptoms of angina with positive findings at stress testing scheduled for coronary angiography (CA), while dual source computed tomography (DSCT) examinations were randomly done by one of the three different scan modes [HPS, sequential mode (SEQ), low-pitch spiral mode (LPS)] one week before CA examinations. The image quality, radiation dose and stent patency of DSCT were evaluated blinded to the results of CA. RESULTS 180 patients with total 256 stents were enrolled in this study. There was no significant difference on the image quality of DSCT by HPS (1.4±0.5), SEQ (1.5±0.5) and LPS (1.3±0.6) (P>0.05). The noise of images reconstructed with B26f kernel in HPS is significantly increased than in SEQ/LPS (P<0.05), while no significant difference with images reconstructed with B46f kernel (P>0.05). Heart rate (HR) variability had a slight impact on the image quality for HPS (P<0.05), not for LPS/SEQ (P>0.05). In the assessment of stent restenosis compared with CA on per-stent basis, there was no significant difference on sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of DSCT using HPS (100%, 97.1%, 83.3%, 100%), LPS (92.3%, 95.9%, 80%, 98.6%) and SEQ (93.3%, 97.3%, 87.5%, 98.6%) (P>0.05). The effective dose of DSCT by HPS (1.0±0.5mSv) is significant less than that by SEQ (3.0±1.4mSv) or LPS (13.0±5.4mSv) (P<0.01). CONCLUSIONS DSCT using HPS provides good diagnostic accuracy on coronary stent patency compared with CA, similar to that by SEQ/LPS, whereas with lower effective dose in patients with HR lower than 65bpm.
Collapse
Affiliation(s)
- Yang Xia
- Cardiology Department, Chinese PLA General Hospital, Beijing 100853, China.
| | | | | | | | | | | | | |
Collapse
|
50
|
Krissak R, Henzler T, Prechel A, Reichert M, Gruettner J, Sueselbeck T, Schoenberg SO, Fink C. Triple-rule-out dual-source CT angiography of patients with acute chest pain: Dose reduction potential of 100kV scanning. Eur J Radiol 2012; 81:3691-6. [PMID: 21163600 DOI: 10.1016/j.ejrad.2010.11.021] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2010] [Accepted: 11/17/2010] [Indexed: 10/18/2022]
|