Copyright
©The Author(s) 2016. Published by Baishideng Publishing Group Inc. All rights reserved.
World J Orthop. Aug 18, 2016; 7(8): 501-506
Published online Aug 18, 2016. doi: 10.5312/wjo.v7.i8.501
Published online Aug 18, 2016. doi: 10.5312/wjo.v7.i8.501
Four corner fusion using a multidirectional angular stable locking plate
Tahseen Chaudhry, Michelle Spiteri, Dominic Power, Mark Brewster, Department of Hand Surgery, Queen Elizabeth Hospital, Birmingham B15 2TH, United Kingdom
Author contributions: Chaudhry T contributed to design and planning, protocol, data collection and processing, literature review, paper write up and revisions; Spiteri M contributed to data collection and processing, literature review; Power D contributed to study design and setup, data collection, paper review; Brewster M contributed to design and planning, protocol, data collection and processing, literature review.
Institutional review board statement: The study met the requirements of our hospital Institutional Review Board for clinical research. None of the authors have any conflict of interest to declare.
Informed consent statement: All study participants, or their legal guardian, provided informed written consent prior to study enrollment.
Conflict-of-interest statement: None of the individual authors of this paper have any conflicts of interest.
Data sharing statement: No additional data are available for this study. All data are included in the paper itself.
Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Correspondence to: Dr. Tahseen Chaudhry, Department of Hand Surgery, Queen Elizabeth Hospital, Edgbaston, Birmingham B15 2TH, United Kingdom. tahseen_c@hotmail.com
Telephone: +44-1217-775956 Fax: +44-1213-712000
Received: January 31, 2016
Peer-review started: February 1, 2016
First decision: March 24, 2016
Revised: May 11, 2016
Accepted: June 1, 2016
Article in press: June 3, 2016
Published online: August 18, 2016
Processing time: 198 Days and 20.1 Hours
Peer-review started: February 1, 2016
First decision: March 24, 2016
Revised: May 11, 2016
Accepted: June 1, 2016
Article in press: June 3, 2016
Published online: August 18, 2016
Processing time: 198 Days and 20.1 Hours
Core Tip
Core tip: This paper demonstrates that a multi angle locking plate is a suitable device for four corner fusion. It demonstrates that results are comparable to those of other means of fusion in the short to medium term.