Luo J, Chen JD, Chen Q, Yue LX, Zhou G, Lan C, Li Y, Wu CH, Lu JQ. Contrast-enhanced ultrasound improved performance of breast imaging reporting and data system evaluation of critical breast lesions. World J Radiol 2016; 8(6): 610-617 [PMID: 27358689 DOI: 10.4329/wjr.v8.i6.610]
Corresponding Author of This Article
Qing Chen, BM, Department of Ultrasound, Sichuan Provincial People’s Hospital, No. 32 First Ring Road, Chengdu 610072, Sichuan Province, China. 1718686103@qq.com
Research Domain of This Article
Radiology, Nuclear Medicine & Medical Imaging
Article-Type of This Article
Clinical Trials Study
Open-Access Policy of This Article
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
World J Radiol. Jun 28, 2016; 8(6): 610-617 Published online Jun 28, 2016. doi: 10.4329/wjr.v8.i6.610
Table 1 Final pathological diagnosis of 235 breast lesions and breast imaging reporting and data system after contrast- enhanced ultrasound
Histopathological diagnosis
BI-RADS after CEUS
Total
3
4A
4B
4C
5
Benign lesions
139
Fibroadenoma
47
3
1
2
53
Fibrocystic mastopathy
34
1
35
Complex sclerosing adenosis
2
2
1
5
Hyperplasia
2
1
1
4
Chronic mastitis
12
5
3
1
21
Granulomatous mastitis
2
1
1
4
Intraductal papilloma
4
2
3
9
Benign phyllodes tumor
2
1
3
Hamartoma
1
1
2
Radial scar
2
2
Bolus material after operation
1
1
Malignant lesions
96
IDC
7
1
3
5
62
78
DCIS
2
1
3
3
9
Mucinous carcinoma
2
1
3
Infiltrating lobular carcinoma
2
2
Diffused large B-cell lymphoma
1
1
2
Malignant phyllodes tumor
1
1
Solid neuroendocrine carcinoma
1
1
Total
235
Table 2 Enhancement patterns of invasive malignant tumors classified as breast lesions and breast imaging reporting and data system S 3
No.
Size (mm)
LN
Histology
Mammography
1
18 × 15
Negative
IDC (triple negative)
Hyperplasia fibrocystic
2
14.6 × 10.7
Negative
IDC (triple negative)
Mastopathy
3
12 × 8
Negative
IDC (HER2)
Solid lesion
4
19 × 15
Negative
Mixed mucinous carcinoma(Luminal A)
Hyperplasia
5
25 × 17
Negative
IDC (triple negative)
Phyllodes tumor
6
30 × 15
Positive
IDC (triple negative)
Solid lesion
7
30 × 25
Negative
IDC (Luminal B)
Without
8
18.8 × 15.7
Negative
IDC (triple negative)
Solid lesion
9
38 × 37
Negative
Diffused B-cell lymphoma
Without
10
11 × 10
Negative
Mucinous carcinoma
Without
11
17 × 14
Negative
Mucinous carcinoma
Adenoma
Table 3 Enhancement patterns of invasive malignant tumors classified as breast lesions and breast imaging reporting and data system S 4A (false negative lesions)
No.
Enhancement patterns
Time
Intensity
Scope after enhancement
Direction
Craw-like pattern
Nourishing vessel
Shape after enhancement
1
Rapid
Hyper
Equal
Complex
Absent
Absent
Regular
2
Synchronous
Iso
Equal
Complex
Absent
Absent
Irregular
3
Rapid
Hyper
Smaller
Centripetal
Absent
Absent
Regular
4
Rapid
Hyper
Equal
Complex
Absent
Absent
Regular
5
Rapid
Hyper
Equal
Centripetal
Absent
Absent
Regular
6
Rapid
Hyper
Larger
Complex
Absent
Present
Regular
7
Rapid
Hyper
Larger
Complex
Absent
Absent
Irregular
8
Synchronous
Hyper
Equal
Complex
Absent
Absent
Regular
9
Slow
Hypo
Equal
Centripetal
Absent
Absent
Regular
10
Rapid
Hyper
Smaller
Complex
Absent
Present
Irregular
11
Slow
Hypo
Smaller
Centripetal
Absent
Absent
Regular
Table 4 The effect of increasing biopsy thresholds on biopsy rates, cancer-to-biopsy yields, and malignancies missed
BI-RADS category
Biopsy rate (%)
Invasive cancers recommended for 6 mo follow-up (%)
Cancer-to-biopsy yield (%)
If biopsy performed on all BI-RADS4 lesions
235 (100)
0 (0)
96/235 (40.85)
> BI-RADS 3 (2%-94%)
119 (50.64)
7 (2.98)
87/119 (73.11)
> BI-RADS 4A (10%-94%)
99 (42.13)
11 (4.68)
82/99 (82.83)
> BI-RADS 4B (50%-94%)
86 (36.60)
15 (7.66)
78/86 (90.70)
> BI-RADS 4C (95%-100%)
74 (31.49)
21 (9.79)
69/74 (93.24)
Citation: Luo J, Chen JD, Chen Q, Yue LX, Zhou G, Lan C, Li Y, Wu CH, Lu JQ. Contrast-enhanced ultrasound improved performance of breast imaging reporting and data system evaluation of critical breast lesions. World J Radiol 2016; 8(6): 610-617