Original Article
Copyright ©2012 Baishideng Publishing Group Co.
World J Radiol. May 28, 2012; 4(5): 207-214
Published online May 28, 2012. doi: 10.4329/wjr.v4.i5.207
Table 1 Overall patient- and region-based diagnostic accuracy of diffusion-weighted imaging and positron emission tomography and computed tomography n (%)
SensitivitySpecificityPPVNPVAccuracy
Patient-based DWI (n = 25)8/9 (88.9)7/16 (43.8)8/17 (47.1)7/8 (87.5)15/25 (60.0)
PET/CT (n = 25)4/9 (44.4)15/16 (93.8)4/5 (80.0)15/20 (75.0)16/25 (64.0)
Region-based DWI (n = 200)30/36 (83.3)84/164 (51.2)30/110 (27.3)84/90 (93.3)114/200 (57.0)
PET/CT (n = 200)14/36 (38.9)158/164 (96.3)14/20 (70.0)158/180 (87.8)172/200 (86.0)
Table 2 Region-based diagnostic accuracy of diffusion-weighted imaging and positron emission tomography and computed tomography n (%)
SensitivitySpecificityAccuracy
Common iliac LNs
DWI (n = 50)6/7 (85.7)22/43 (51.2)28/50 (56.0)
PET/CT (n = 50)3/7 (42.9)41/43 (95.3)44/50 (88.0)
External iliac LNs
DWI (n = 50)6/7 (85.7)22/43 (51.2)28/50 (56.0)
PET/CT (n = 50)3/7 (42.9)41/43 (95.3)44/50 (88.0)
Internal iliac LNs
DWI (n = 50)8/10 (80.0)20/40 (50.0)28/50 (56.0)
PET/CT (n = 50)4/10 (40.0)39/40 (97.5)43/50 (86.0)
Obturator LNs
DWI (n = 50)10/12 (83.3)20/38 (52.6)30/50 (60.0)
PET/CT (n = 50)4/12 (33.3)37/38 (97.4)41/50 (82.0)
Table 3 Node-based sensitivity of diffusion-weighted imaging and positron emission tomography and computed tomography according to the node size n (%)
Node size (mm)DWIPET/CT
1-918/24 (75.0)4/24 (16.7)
10-1812/12 (100.0)10/12 (83.3)
Total30/36 (83.3)14/36 (38.9)
Table 4 Patient-stage based diagnostic accuracy of diffusion-weighted imaging and positron emission tomography and computed tomography n (%)
SensitivitySpecificityAccuracy
Stage I
DWI (n = 13)1/2 (50.0)5/11 (45.5)6/13 (46.2)
PET/CT (n = 13)0/2 (42.9)11/11 (100.0)11/13 (84.6)
Stage II
DWI (n = 9)4/4 (100.0)2/5 (40.0)6/9 (66.7)
PET/CT (n = 9)2/4 (50.0)4/5 (80.0)6/9 (66.7)
Stage III
DWI (n = 3)3/3 (100.0)0/0 (0)3/3 (100.0)
PET/CT (n = 3)2/3 (66.7)0/0 (0)2/3 (66.7)