Retrospective Study
Copyright ©The Author(s) 2024. Published by Baishideng Publishing Group Inc. All rights reserved.
World J Radiol. Jun 28, 2024; 16(6): 196-202
Published online Jun 28, 2024. doi: 10.4329/wjr.v16.i6.196
Prediction of hepatic artery occlusion after liver transplantation by ultrasound characteristics and clinical risk factors
Yu-Ting Lai, Yi Chen, Tai-Shi Fang, Zhi-Yan Li, Ning-Bo Zhao
Yu-Ting Lai, Yi Chen, Zhi-Yan Li, Ning-Bo Zhao, Department of Ultrasound, National Clinical Research Centre for Infectious Diseases, The Third People’s Hospital of Shenzhen, The Second Hospital Affiliated with the Southern University of Science and Technology, Shenzhen 518112, Guangdong Province, China
Tai-Shi Fang, Department of Liver Surgery, National Clinical Research Centre for Infectious Diseases, The Third People’s Hospital of Shenzhen, The Second Hospital Affiliated with the Southern University of Science and Technology, Shenzhen 518112, Guangdong Province, China
Co-first authors: Yu-Ting Lai and Yi Chen.
Co-corresponding authors: Zhi-Yan Li and Ning-Bo Zhao.
Author contributions: Lai YT and Chen Y contributed equally to this work; Lai YT designed and preformed the research study; Chen Y collected the primary data and wrote the manuscript; Fang TS sorted the reference literature; Li ZY and Zhao NB were responsible for supervising the study and revising the manuscript; and all authors read and approved the final version.
Supported by The National Natural Science Foundation of China, No. 82172563; and The Research Program Foundation of Shenzhen, No. JCYJ20210324131809027.
Institutional review board statement: This study was reviewed and approved by the Ethics Committee of The Third People’s Hospital of Shenzhen (No. 2019014).
Informed consent statement: All study participants or their legal guardians provided written informed consent for personal and medical data collection before study enrolment.
Conflict-of-interest statement: The authors declare no conflict of interest for this article.
Data sharing statement: The datasets used in this study can be obtained from the corresponding author.
Open-Access: This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/licenses/by-nc/4.0/
Corresponding author: Ning-Bo Zhao, MM, Chief Doctor, Department of Ultrasound, National Clinical Research Centre for Infectious Diseases, The Third People’s Hospital of Shenzhen, The Second Hospital Affiliated with the Southern University of Science and Technology, No. 29 Bulan Road, Shenzhen 518112, Guangdong Province, China. Drzhaoningbo@163.com
Received: February 23, 2024
Revised: May 7, 2024
Accepted: May 28, 2024
Published online: June 28, 2024
Processing time: 123 Days and 22.5 Hours
Core Tip

Core Tip: This research investigated the related risk factors and ultrasound features of hepatic artery occlusion (HAO) following liver transplantation. It highlighted that ultrasound measure parameters, such as resistance index, peak systolic velocity, and portal vein velocity, could effectively predict the development of HAO. Furthermore, clinical risk factors, including complex hepatic artery reconstruction, high gamma-glutamyltransferase level, and so on, also increased HAO occurrence. These findings highlight the key role of selecting and increasing the frequency of ultrasound monitoring to mitigate risk and optimize prognosis, offering valuable insights for clinicians in managing this complex complication effectively.