Minireviews
Copyright ©The Author(s) 2017. Published by Baishideng Publishing Group Inc. All rights reserved.
World J Cardiol. Mar 26, 2017; 9(3): 230-240
Published online Mar 26, 2017. doi: 10.4330/wjc.v9.i3.230
Paroxysmal atrial fibrillation ablation: Achieving permanent pulmonary vein isolation by point-by-point radiofrequency lesions
Alonso Pedrote, Juan Acosta, Beatriz Jáuregui-Garrido, Manuel Frutos-López, Eduardo Arana-Rueda
Alonso Pedrote, Juan Acosta, Beatriz Jáuregui-Garrido, Manuel Frutos-López, Eduardo Arana-Rueda, Arrhythmia Section, Cardiology Department, Virgen del Rocío University Hospital, 41013 Seville, Spain
Author contributions: Pedrote A and Acosta J performed the majority of the writing; Jáuregui-Garrido B contributed to writing; Frutos-López M and Arana-Rueda E prepared figures and tables, contributed to review of the literature and discussed the manuscript; Pedrote A designed the outline and coordinated the writing of the paper.
Conflict-of-interest statement: There is no conflict of interest associated with any of the authors.
Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Correspondence to: Alonso Pedrote, MD, PhD, Arrhythmia Section, Cardiology Department, Virgen del Rocío University Hospital, C/ Manuel Siurot s/n, 41013 Seville, Spain. pedrote@hotmail.com
Telephone: +34-659-108232
Received: October 27, 2016
Peer-review started: November 2, 2016
First decision: December 1, 2016
Revised: December 14, 2016
Accepted: January 11, 2017
Article in press: January 14, 2017
Published online: March 26, 2017
Processing time: 150 Days and 15.7 Hours
Core Tip

Core tip: Results of pulmonary vein isolation remains suboptimal in terms of long-term outcomes. Improving lesion durability could reduce atrial fibrillation recurrence rate after pulmonary vein isolation. This manuscript reviews current techniques proposed in order to achieve more durable pulmonary vein isolation by point-by-point radiofrequency ablation. The role and potential benefits of these techniques are discussed according to current clinical evidence. Furthermore a stepwise approach to achieve permanent pulmonary vein isolation is proposed.