Published online Jul 27, 2012. doi: 10.4240/wjgs.v4.i7.177
Revised: July 23, 2012
Accepted: July 24, 2012
Published online: July 27, 2012
AIM: To investigate the use of the V-Loc wound closure device for transabdominal preperitoneal hernia repair.
METHODS: We performed conventional transabdominal preperitoneal hernia repair in 19 patients, including one single incisional case using V-Loc. Except for the use of V-Loc for peritoneal closure, the procedures were the same as those used in conventional techniques.
RESULTS: Although the operators included 2 residents who have no experience in laparoscopic herniorrhaphy and intracorporeal suture, the operations were completed. We believe that V-Loc is especially suitable for inexperienced surgeons and the use of V-Loc reduces the operative time by a small amount but reduces operator stress significantly.
CONCLUSION: We conclude that V-Loc is the ideal peritoneal closure device for transabdominal preperitoneal hernia repair.