Successful endoscopic removal of three embedded esophageal self-expanding metal stents
Xiao-Qin Liu, Min Zhou, Wen-Xin Shi, Yi-Ying Qi, Hui Liu, Bin Li, Hong-Wei Xu, Department of Gastroenterology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China
Author contributions: Liu XQ, Li B and Xu HW designed and performed the operation and wrote the manuscript; Zhou M, Shi WX, Qi YY and Liu H collected the data and revised the manuscript.
Supported by Shandong Provincial Science and Technology Committee of China, No. 2014GGH218034.
Institutional review board statement: The research hcrcby is approved by the Medical Ethics Committee of Shandong Provincial Hospital affiliated to Shandong University.
Informed consent statement: The participants provide written informed consent to participate in this research.
Conflict-of-interest statement: No conflict of interest exits in the submission of this manuscript, and manuscript is approved by all authors for publication.
Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Correspondence to: Hong-Wei Xu, MD, PhD, Department of Gastroenterology, Shandong Provincial Hospital Affiliated to Shandong University, 324, Jing 5 Rd, Jinan 250021, Shandong Province, China. xu_hong_wei@sina.com
Telephone: +86-531-68776350 Fax: +86-531-87902348
Received: February 9, 2017
Peer-review started: February 14, 2017
First decision: May 17, 2017
Revised: July 1, 2017
Accepted: July 21, 2017
Article in press: July 24, 2017
Published online: September 16, 2017
Processing time: 213 Days and 9 Hours
Peer-review started: February 14, 2017
First decision: May 17, 2017
Revised: July 1, 2017
Accepted: July 21, 2017
Article in press: July 24, 2017
Published online: September 16, 2017
Processing time: 213 Days and 9 Hours
Core Tip
Core tip: Stent embedding is a common complication that precludes the safe removal of stents. The article reports a case of benign esophageal strictures with three stents embedded and remained in place for over a year. We successfully removed the three embedded stents by using the stent-in-stent technique. The stent-in-stent technique is effective for the removal of multiple stents that are embedded in the esophageal wall.