1
|
Nawacki Ł, Gorczyca-Głowacka I, Zieliński P, Znamirowski P, Kozłowska-Geller M, Ciba-Stemplewska A, Kołomańska M. A 22-G or a 25-G Needle: Which One to Use in the Diagnostics of Solid Pancreatic Lesions? A Systematic Review and Meta-Analysis. Cancers (Basel) 2024; 16:2266. [PMID: 38927971 PMCID: PMC11202301 DOI: 10.3390/cancers16122266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Revised: 06/04/2024] [Accepted: 06/12/2024] [Indexed: 06/28/2024] Open
Abstract
With the 12th highest incidence and a common late diagnostic at advanced stages, neoadjuvant therapies for pancreatic cancer are important, but they require a confirmed diagnosis. Being a diagnostic standard, the clarification of the clinical relevance of needle gauges is needed, as larger ones may retrieve more tissue for diagnostics, but may also increase the risk of complications. We performed a meta-analysis to compare the efficiency of the most commonly used 22-G and 25-G needles for EUS guided biopsy in solid pancreatic lesions. The MEDLINE (via PubMed), Embase, Cochrane (CENTRAL), and Scopus databases were searched with "EUS", "needle", "FNA", "pancreas", "prospective", "22G", and "25G" keywords. Mixed effects were assessed in the model, with a mean of 86% and a 95% confidence interval. Fourteen prospective studies that compared the efficiency of 22-G and 25-G biopsy needles in 508 and 524 lesions, respectively, were analyzed, along with 332 specimens biopsied using both needle sizes. The groups did not significantly differ in the outcomes. A low degree of heterogeneity was observed overall, except for specimen adequacy. Moreover, 22-G and 25-G needles have comparable safety and efficacy for focal pancreatic lesion biopsies without a high risk of complications.
Collapse
Affiliation(s)
- Łukasz Nawacki
- Collegium Medicum, The Jan Kochanowski University in Kielce, Aleja IX Wieków Kielc 19A, 25-317 Kielce, Poland (M.K.)
| | | | | | | | | | | | | |
Collapse
|
2
|
Coban S, Zahid KS, Brugge WR. The future of EUS. ENDOSCOPIC ULTRASONOGRAPHY 2024:287-293. [DOI: 10.1002/9781119697893.ch31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2025]
|
3
|
Usefulness of Adding Maspin Staining to p53 Staining for EUS-FNA Specimens of Pancreatic Ductal Adenocarcinoma. J Clin Med 2022; 11:jcm11206097. [PMID: 36294419 PMCID: PMC9605637 DOI: 10.3390/jcm11206097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2022] [Revised: 10/11/2022] [Accepted: 10/13/2022] [Indexed: 11/05/2022] Open
Abstract
Background: Endoscopic ultrasound-guided puncture aspiration biopsy (EUS-FNA) of pancreatic ductal adenocarcinoma (PDAC) is highly diagnostic, but it is difficult to distinguish from benign disease. Our objective was to determine the usefulness of maspin staining, in addition to conventional p53 staining, in the diagnosis of PDAC by EUS-FNA. Methods: Of the patients who underwent EUS-FNA and were diagnosed with PDAC, we retrospectively identified 90 cases in which both maspin and p53 staining were performed. In addition, we identified 28 cases of benign pancreatic disease diagnosed using EUS-FNA and these were selected as a control group. For analysis of EUS-FNA specimens, Cohen’s Kappa (κ) coefficient and the prevalence and bias adjusted Kappa statistic (PABAK) were applied to assess the significance of sensitivity and specificity, comparing p53, maspin, p53+maspin. Results: The sensitivity and specificity of p53 staining were 48.9% and 100%. The κ coefficient was 0.31 (95%CI 0.18−0.44) (p < 0.01) and the PABAK coefficient was 0.22 (95%CI 0.03−0.40). The results for maspin staining were 88.9% and 92.9%. The κ coefficient was 0.72 (95%CI 0.54−0.90) (p < 0.01) and the PABAK coefficient was 0.78 (95%CI 0.64−0.88). The results for the combination of maspin and p53 staining were 94.4% and 92.2%. The κ coefficient was 0.82 (95%CI 0.64−1.00) (p < 0.01) and the PABAK coefficient was 0.86 (95%CI 0.74−0.94). Conclusion: Adding maspin staining to p53 staining showed high sensitivity and specificity. Our results demonstrated the usefulness of their combined use that might contribute to the improvement of tissue diagnostic performance of PDAC by EUS-FNA.
Collapse
|
4
|
Sakai T, Udagawa H, Kirita K, Nomura S, Itotani R, Tamiya Y, Sugimoto A, Ota T, Naito T, Izumi H, Nosaki K, Ikeda T, Zenke Y, Matsumoto S, Yoh K, Niho S, Nakai T, Ishii G, Goto K. Comparison of the efficiency of endobronchial ultrasound-guided transbronchial needle aspiration using a 22G needle versus 25G needle for the diagnosis of lymph node metastasis in patients with lung cancer: a prospective randomized, crossover study. Transl Lung Cancer Res 2021; 10:3745-3758. [PMID: 34733625 PMCID: PMC8512458 DOI: 10.21037/tlcr-21-480] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Accepted: 08/24/2021] [Indexed: 12/25/2022]
Abstract
Background Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is generally performed for the diagnosis of hilar/mediastinal lymph node metastasis in patients with lung cancer. Recently, a 25-gauge (G) needle became available, but robust evidence of its usefulness in routine clinical practice is still lacking. Methods A prospective randomized crossover trial was performed, in which patients with suspected hilar/mediastinal lymph node metastasis of lung cancer underwent EBUS-TBNA. The primary endpoint was the rate of yield histology specimens containing malignant cells. Results From December 2018 to February 2020, 102 patients were randomly assigned to EBUS-TBNA using a 22G needle first, followed by a 25G needle (n=50) or EBUS-TBNA using a 25G needle first, followed by a 22G needle (n=52). There was no difference in the diagnostic yield of malignancy between the histology specimens obtained by using the 22G and 25G needles (75% vs. 75%, respectively, P=0.37). The sizes of the tissue samples (16.4 vs. 4.9 mm2, respectively) and number of malignant cells in the tissue samples (626 vs. 400, respectively) were both significantly higher when using the 22G needle than when using the 25G needle. Conclusions No significant difference in the diagnostic yield between the 22G and 25G needles was observed for the diagnosis of lymph node metastasis of lung cancer, suggesting that needles of either gauge could be used for the biopsy. However, we would recommend use of the 22G needle, because it provided larger specimens and specimens containing larger numbers of malignant cells. Trial Registration University hospital Medical Information Network Clinical Trial Registry (ID: UMIN000036680).
Collapse
Affiliation(s)
- Tetsuya Sakai
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Hibiki Udagawa
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Keisuke Kirita
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Shogo Nomura
- Biostatistics Division, Center for Research Administration and Support, National Cancer Center, Kashiwa, Japan
| | - Ryo Itotani
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Yutaro Tamiya
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Akira Sugimoto
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Takahiro Ota
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Tomoyuki Naito
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Hiroki Izumi
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Kaname Nosaki
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Takaya Ikeda
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Yoshitaka Zenke
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Shingo Matsumoto
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Kiyotaka Yoh
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Seiji Niho
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| | - Tokiko Nakai
- Department of Pathology and Clinical Laboratories, National Cancer Center Hospital East, Kashiwa, Japan
| | - Genichiro Ishii
- Department of Pathology and Clinical Laboratories, National Cancer Center Hospital East, Kashiwa, Japan
| | - Koichi Goto
- Department of Thoracic Oncology, National Cancer Center Hospital East, Kashiwa, Japan
| |
Collapse
|
5
|
Tomita Y, Torisu Y, Chiba M, Kinoshita Y, Akasu T, Shimamoto N, Abe T, Kanazawa K, Takakura K, Tsukinaga S, Nakano M, Toyoizumi H, Kato M, Saruta M. Endoscopic ultrasound-guided fine-needle biopsy histology with a 22-gauge Franseen needle and fine-needle aspiration liquid-based cytology with a conventional 25-gauge needle provide comparable diagnostic accuracy in solid pancreatic lesions. JGH OPEN 2021; 5:1092-1096. [PMID: 34584980 PMCID: PMC8454471 DOI: 10.1002/jgh3.12642] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 08/10/2021] [Accepted: 08/10/2021] [Indexed: 11/22/2022]
Abstract
Background and Aim Fine‐needle biopsy (FNB) needles obtain more core samples and support the shift from cytologic to histologic evaluation; however, recent studies have proposed a superior diagnostic potential for liquid‐based cytology (LBC). This study compared the diagnostic ability of endoscopic ultrasound (EUS)‐guided FNB histology with a 22‐gauge Franseen needle (22G‐FNB‐H) and fine‐needle aspiration (FNA) LBC with a conventional 25‐gauge needle (25G‐FNA‐LBC). Methods We analyzed 46 patients who underwent both 22G‐FNB‐H and 25G‐FNA‐LBC in the same lesion during the same endoscopic procedure. This study evaluated the diagnostic ability of each needle, diagnostic concordance between needles, and incremental diagnostic effect of both needles compared to using each needle alone. Results The agreement rate for malignancy between both techniques was 93.5% (kappa value = 0.82). There was no significant difference in the diagnostic ability of both methods. 22G‐FNB‐H and 25G‐FNA‐LBC provided an incremental diagnostic accuracy in two (4.3%) cases and one (2.2%) case, respectively. Conclusion Our study demonstrated that the diagnostic accuracy of 25G‐FNA‐LBC and 22G‐FNA‐H for solid pancreatic lesions were comparable. A conventional 25‐gauge needle that punctures lesions with ease can be used in difficult cases and according to the skill of the endoscopist.
Collapse
Affiliation(s)
- Yoichi Tomita
- Division of Gastroenterology and Hepatology, Department of Internal Medicine The Jikei University School of Medicine Tokyo Japan
| | - Yuichi Torisu
- Division of Gastroenterology and Hepatology, Department of Internal Medicine The Jikei University School of Medicine Tokyo Japan
| | - Masafumi Chiba
- Department of Endoscopy The Jikei University School of Medicine Tokyo Japan
| | - Yuji Kinoshita
- Division of Gastroenterology and Hepatology, Department of Internal Medicine The Jikei University School of Medicine Tokyo Japan
| | - Takafumi Akasu
- Division of Gastroenterology and Hepatology, Department of Internal Medicine The Jikei University School of Medicine Tokyo Japan
| | - Nana Shimamoto
- Department of Endoscopy The Jikei University School of Medicine Tokyo Japan
| | - Takahiro Abe
- Department of Endoscopy The Jikei University School of Medicine Tokyo Japan
| | - Keisuke Kanazawa
- Department of Endoscopy The Jikei University School of Medicine Tokyo Japan
| | - Kazuki Takakura
- Division of Gastroenterology and Hepatology, Department of Internal Medicine The Jikei University School of Medicine Tokyo Japan
| | - Shintaro Tsukinaga
- Department of Endoscopy The Jikei University School of Medicine Tokyo Japan
| | - Masanori Nakano
- Division of Gastroenterology and Hepatology, Department of Internal Medicine The Jikei University School of Medicine Tokyo Japan
| | - Hirobumi Toyoizumi
- Department of Endoscopy The Jikei University School of Medicine Tokyo Japan
| | - Masayuki Kato
- Department of Endoscopy The Jikei University School of Medicine Tokyo Japan
| | - Masayuki Saruta
- Division of Gastroenterology and Hepatology, Department of Internal Medicine The Jikei University School of Medicine Tokyo Japan
| |
Collapse
|
6
|
Del Vecchio Blanco G, Palmieri G, Giannarelli D, Formica V, Portarena I, Nardecchia A, Troncone E, Benassi M, Giudice E, Anselmo A, Tisone G, Roselli M, Monteleone G, Paoluzi OA. Factors influencing diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic and biliary tumors. Scand J Gastroenterol 2021; 56:498-504. [PMID: 33539716 DOI: 10.1080/00365521.2021.1880628] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND AND AIM Diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is influenced by several factors, primarily operator expertise. Formal training in EUS-FNA, as suggested by the European Society of Gastrointestinal Endoscopy and the American Society for Gastrointestinal Endoscopy guidelines, is not always available and is often expensive and time-consuming. In this study we evaluate factors influencing the diagnostic accuracy of pancreatic EUS-FNA. METHODS In a retrospective study, 557 consecutive EUS-FNAs were evaluated. Several variables relating to the procedures were considered to calculate the EUS-FNA performance over eight years. RESULTS A total of 308 out of 557 EUS-FNAs were selected. Overall sensitivity of EUS-FNA was 66% (95% CI: 60.8-71.8), specificity 100%, and diagnostic accuracy 69% (95% CI: 64.0-74.4). An increase in diagnostic accuracy was observed to >90% using a new fine-needle biopsy (FNB) needle and in the case of simultaneous sampling of primary and metastatic lesions. Diagnostic accuracy >80% was observed after 250 procedures, in the absence of rapid on-site cytopathological examination (ROSE). Multivariate logistic regression analysis confirmed that the FNB needle, operator skill, and double EUS-FNA sampling are associated with high diagnostic accuracy. CONCLUSIONS The learning curve for EUS-FNA may be longer and a considerable number of procedures are needed to achieve high diagnostic accuracy in the absence of ROSE. However, the use of FNB needles and the simultaneous sampling of primary and metastatic lesions can rapidly improve the diagnostic accuracy of the procedure.
Collapse
Affiliation(s)
| | - Giampiero Palmieri
- Anatomic Pathology Unit, Department of Biomedicine and Prevention, University of Rome Tor Vergata, Rome, Italy
| | - Diana Giannarelli
- Biostatistical Unit, Regina Elena Institute-Hospital Physiotherapy Institutes, Rome, Italy
| | | | | | | | - Edoardo Troncone
- Gastroenterology Unit, Department of Systems Medicine, University of Rome Tor Vergata, Rome, Italy
| | - Michela Benassi
- Radiotherapy Unit, Department of Oncohematology, University of Rome Tor Vergata, Rome, Italy
| | - Emilia Giudice
- Radiotherapy Unit, Department of Oncohematology, University of Rome Tor Vergata, Rome, Italy
| | - Alessandro Anselmo
- Transplant Surgery Unit, Department of Surgery, University of Rome Tor Vergata, Rome, Italy
| | - Giuseppe Tisone
- Transplant Surgery Unit, Department of Surgery, University of Rome Tor Vergata, Rome, Italy
| | - Mario Roselli
- Oncology Unit, University of Rome Tor Vergata, Rome, Italy
| | - Giovanni Monteleone
- Gastroenterology Unit, Department of Systems Medicine, University of Rome Tor Vergata, Rome, Italy
| | - Omero Alessandro Paoluzi
- Gastroenterology Unit, Department of Systems Medicine, University of Rome Tor Vergata, Rome, Italy
| |
Collapse
|
7
|
Watanabe S, Miyoshi J, Toki M, Kambayashi K, Kitada S, Nosaka T, Goto T, Ota H, Ochiai K, Gondo K, Ikeuchi N, Tsuji S, Nakamura K, Shibahara J, Hisamatsu T. Effectiveness of introducing a 20-gauge core biopsy needle with a core trap in EUS-FNA/B for diagnosing pancreatic cancer. BMC Gastroenterol 2021; 21:8. [PMID: 33407181 PMCID: PMC7789690 DOI: 10.1186/s12876-020-01583-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 12/15/2020] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/B) is a standard method for pathological diagnosis of pancreatic solid lesions. The EchoTip ProCore 20G® (PC20), a 20-gauge biopsy needle with a forward-bevel core trap, has been available in Japan since 2015. METHODS We compared the efficacy of the PC20 with that of the EchoTip ProCore 22G® (PC22) and Acquire 22G® (AC22) in EUS-FNA/B for diagnosing pancreatic cancer. This retrospective study included 191 patients with pancreatic cancer who underwent EUS-FNA/B using the PC20, PC22, or AC22 at our facility from April 2013 to October 2019. We investigated the patients' clinical characteristics and the diagnostic accuracy and safety of each needle. RESULTS A sufficient stroke length of puncture was secured in all patients. The maximum length under EUS was shorter with the AC22 (22.1 ± 2.2 mm) than PC20 (30.6 ± 0.7 mm, p < 0.01) and PC22 (30.3 ± 0.8 mm, p < 0.01). The histological accuracy was 96.4% with the PC20 but only 58.8% with the PC22 (adjusted p (p-adj) < 0.0001) and 75.0% with the AC22 (p-adj = 0.06). The diagnostic accuracy of the combination of histology and cytology was 96.4% with the PC20, while it was 72.1% with the PC22 (p-adj < 0.0001) and 91.7% with the AC22 (p-adj > 0.99). One patient (0.9%) in the PC20 group developed mild pancreatitis, but no adverse events occurred with the other needles. CONCLUSIONS The PC20 showed better diagnostic capability than the PC22. The diagnostic efficacy was similar between the PC20 and AC22. The high histological accuracy of the PC20 could be advantageous for lesions in which histological assessment is critical.
Collapse
Affiliation(s)
- Shunsuke Watanabe
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Jun Miyoshi
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan.
| | - Masao Toki
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Komei Kambayashi
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Shuichi Kitada
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Takeshi Nosaka
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Tomoyuki Goto
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Hirotaka Ota
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Kazushige Ochiai
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Koichi Gondo
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Nobuhito Ikeuchi
- Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Shujiro Tsuji
- Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Kenji Nakamura
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
- Department of Gastroenterology and Hepatology, Tokyo Dental College Ichikawa General Hospital, 5-11-13 Sugano, Ichikawa-shi, Chiba, 272-8513, Japan
| | - Junji Shibahara
- Department of Pathology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Tadakazu Hisamatsu
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan.
| |
Collapse
|
8
|
Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions. JOURNAL OF SURGERY AND MEDICINE 2021. [DOI: 10.28982/josam.859352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
9
|
Hassan GM, Wyse JM, Paquin SC, Gariepy G, Albadine R, Mâsse B, Trottier H, Sahai AV. A randomized noninferiority trial comparing the diagnostic yield of the 25G ProCore needle to the standard 25G needle in suspicious pancreatic lesions. Endosc Ultrasound 2021; 10:57-61. [PMID: 33402551 PMCID: PMC7980691 DOI: 10.4103/eus.eus_69_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Background and Objectives The aim of the study was to perform the first randomized trial comparing the diagnostic yield, bloodiness, and cellularity of the 25G standard needle (25S) and the 25G ProCore™ needle (25P). Materials and Methods All patients referred to the tertiary care referral center for EUS guided fine-needle aspiration (EUS-FNA) of suspicious solid pancreatic lesions were eligible. EUS-FNA was performed in each lesion with both 25S and 25P needles (the choice of the first needle was randomized), using a multipass sampling pattern, without stylet or suction. Rapid on-site evaluation was used when possible. Pap-stained slides were read by a single experienced cytopathologist, blinded to the needle type. Results One hundred and forty-three patients were recruited. Samples were positive for cancer in 122/143 (85.3%) with the 25S needle versus 126/143 (88.1%) with the 25P needle, negative in 17/143 (11.9%) with the 25S needle versus 13/143 (9.1%) with the 25P needle, and suspicious in 4/143 (2.8%) with each needle. There was no difference in any outcome based on the type of the first needle. No carryover effect was detected (P = 0.214; NS). Cumulative logistic regression analyses showed no associations between the type of needle and diagnostic yield for cancer, cellularity, or bloodiness. The difference in the yield for cancer was 2.9% (-4.2; 10.1%); with the confidence interval upper within the predetermined noninferiority margin of 15%. Conclusion The 25S needle is noninferior to the 25P needle for diagnosing cancer in suspicious pancreatic lesions.
Collapse
Affiliation(s)
- Galab M Hassan
- Division of Gastroenterology, Department of Medicine, Réseau Hospitalier Neuchâtelois, Switzerland; Department of social and preventive Medicine, School of Public Health, Université de Montréal, Québec, Canada
| | - Jonathan M Wyse
- Division of Gastroenterology, Jewish General Hospital, McGill University, Montreal, Canada
| | - Sarto C Paquin
- Division of Gastroenterology, Centre Hospitalier Universitaire de Montréal, Québec, Canada
| | - Gilles Gariepy
- Department of pathology, Centre Hospitalier Universitaire de Montréal, Québec, Canada
| | - Roula Albadine
- Department of pathology, Centre Hospitalier Universitaire de Montréal, Québec, Canada
| | - Benoît Mâsse
- Department of social and preventive Medicine, School of Public Health, Université de Montréal, Québec, Canada; Research Center, Centre Hospitalier Universitaire Sainte-Justine, Université de Montréal, Québec, Canada
| | - Helen Trottier
- Department of social and preventive Medicine, School of Public Health, Université de Montréal, Québec, Canada; Research Center, Centre Hospitalier Universitaire Sainte-Justine, Université de Montréal, Québec, Canada
| | - Anand V Sahai
- Division of Gastroenterology, Centre Hospitalier Universitaire de Montréal, Québec, Canada
| |
Collapse
|
10
|
Xie C, Bohy K, Abdallah MA, Patel B, Nelson ME, Bleeker J, Askeland R, Abdullah A, Aloreidi K, Kiani R, Atiq M. Finding a needle in a haystack: Endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic masses in the setting of chronic pancreatitis. Ann Gastroenterol 2020; 33:418-425. [PMID: 32624664 PMCID: PMC7315714 DOI: 10.20524/aog.2020.0484] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Accepted: 03/05/2020] [Indexed: 12/22/2022] Open
Abstract
Background: The mainstay for the definitive diagnosis of pancreatic lesions is endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). However, there is evidence that EUS-FNA has low sensitivity in the setting of chronic pancreatitis (CP). This single-center retrospective study aimed to compare and analyze the diagnostic yield of EUS-FNA for solid pancreatic lesions in the presence and absence of CP, and to further investigate strategies for overcoming the low diagnostic yield in the setting of CP. Methods: This study identified patients who underwent EUS-FNA at Sanford USD Medical Center (SD, USA) for a solid pancreatic lesion between July 15, 2011, and November 30, 2017. Data on demographics, clinical features, cross-sectional imaging findings, EUS findings, cytology/pathology, and clinical follow up were collected. Results: The final diagnosis was adenocarcinoma in 156 patients (67%), neuroendocrine tumor in 27 (12%), lymphoma in 6 (3%), metastatic malignancy in 8 (4%), and benign etiologies in 35 (15%). CP was identified in 44/234 (19%) patients. The overall diagnostic sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for EUS-FNA were 92.9%, 97.1%, 99.5%, 70.8%, and 93.5%, respectively. The sensitivity (80% vs. 95%, P=0.020) and accuracy (86% vs. 95%, P=0.043) were significantly lower in patients with CP compared to those without CP. Conclusion: CP can significantly affect the EUS-FNA diagnostic yield of solid pancreatic neoplasms. A high index of clinical suspicion is required in these cases to make a definitive diagnosis.
Collapse
Affiliation(s)
- Chencheng Xie
- Department of Internal Medicine (Chencheng Xie, Mohamed A. Abdallah, Ammar Abdullah, Khalil Aloreidi, Rabia Kiani)
| | | | - Mohamed A Abdallah
- Department of Internal Medicine (Chencheng Xie, Mohamed A. Abdallah, Ammar Abdullah, Khalil Aloreidi, Rabia Kiani)
| | - Bhaveshkumar Patel
- Division of Gastroenterology and Hepatology (Bhaveshkumar Patel, Muslim Atiq)
| | | | - Jonathan Bleeker
- Division of Hematology & Oncology (Jonathan Bleeker), University of South Dakota, Sioux Falls, SD, USA
| | - Ryan Askeland
- Department of Pathology (Kimberlee Bohy, Ryan Askeland)
| | - Ammar Abdullah
- Department of Internal Medicine (Chencheng Xie, Mohamed A. Abdallah, Ammar Abdullah, Khalil Aloreidi, Rabia Kiani)
| | - Khalil Aloreidi
- Department of Internal Medicine (Chencheng Xie, Mohamed A. Abdallah, Ammar Abdullah, Khalil Aloreidi, Rabia Kiani)
| | - Rabia Kiani
- Department of Internal Medicine (Chencheng Xie, Mohamed A. Abdallah, Ammar Abdullah, Khalil Aloreidi, Rabia Kiani)
| | - Muslim Atiq
- Division of Gastroenterology and Hepatology (Bhaveshkumar Patel, Muslim Atiq)
| |
Collapse
|
11
|
Castellani D, Germani U, Bassotti G, Manta R. EUS Standard Devices. ENDOTHERAPY IN BILIOPANCREATIC DISEASES: ERCP MEETS EUS 2020:47-63. [DOI: 10.1007/978-3-030-42569-2_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2025]
|
12
|
Hann A, Walter BM, Epp S, Ayoub YK, Meining A. The "Twist-Needle" - a new concept for endoscopic ultrasound-guided fine needle-biopsy. Endosc Int Open 2019; 7:E1658-E1662. [PMID: 31788549 PMCID: PMC6877432 DOI: 10.1055/a-0998-3997] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Accepted: 06/11/2019] [Indexed: 02/08/2023] Open
Abstract
Background and study aims Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) represents a standard method for tissue acquisition of lesions adjacent to the gastrointestinal wall. Needles of 19 gauge acquire more tissue than needles with a smaller diameter, but are often unable to penetrate solid, rigid masses. In this study we evaluated a novel prototype that links forward movement of the needle to rotation of the needle tip. Materials and methods Two needle-models that generate either a regular axial movement or a combination of axial movement with rotation of the needle tip were compared ex vivo for measurement of pressure needed to penetrate artificial tissue. Furthermore, a standard 19-gauge EUS-FNB needle was compared to a modified model ("Twist Needle") in an ex vivo model to measure the amount of tissue obtained. Results Pressure measurements using the rotating needle revealed that significantly less pressure is needed for penetration compared to the regular axial movement (mean ± SEM; 3.7 ± 0.3 N vs. 5.5 ± 0.3 N). Using the modified 19-gauge "Twist Needle" did not diminish tissue acquisition measured by surface amount compared to a standard needle (37 ± 5 mm² vs. 35 ± 6 mm²). Conclusion The method of rotation of an EUS-FNB needle tip upon forward movement requires less pressure for penetration but does not diminish tissue acquisition. Hence, the concept of our "Twist Needle" may potentially reduce some of the current limitations of standard EUS-FNB.
Collapse
Affiliation(s)
- Alexander Hann
- Interventional and Experimental Endoscopy (InExEn), Internal Medicine II, University Hospital Wuerzburg, Wuerzburg, Germany,Department of Internal Medicine I, Ulm University, Ulm, Germany,Corresponding author PD Dr. med. Alexander Hann Universitätsklinikum WürzburgMedizinische Klinik und Poliklinik II, GastroenterologieOberdürrbacher Str. 697080 Würzburg
| | | | - Sonja Epp
- Interventional and Experimental Endoscopy (InExEn), Internal Medicine II, University Hospital Wuerzburg, Wuerzburg, Germany,Department of Internal Medicine I, Ulm University, Ulm, Germany
| | | | - Alexander Meining
- Interventional and Experimental Endoscopy (InExEn), Internal Medicine II, University Hospital Wuerzburg, Wuerzburg, Germany,Department of Internal Medicine I, Ulm University, Ulm, Germany
| |
Collapse
|
13
|
Tontini GE, Manfredi G, Orlando S, Neumann H, Vecchi M, Buscarini E, Elli L. Endoscopic ultrasonography and small-bowel endoscopy: Present and future. Dig Endosc 2019; 31:627-643. [PMID: 31090965 DOI: 10.1111/den.13429] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 05/13/2019] [Indexed: 12/12/2022]
Abstract
Over the last decade, impressive technological advances have occurred in ultrasonography and small-bowel endoscopy. Nowadays, endoscopic ultrasonography is an essential diagnostic tool and a therapeutic weapon for pancreatobiliary disorders. Capsule endoscopy and device-assisted enteroscopy have quickly become the reference standard for the diagnosis of small-bowel luminal diseases, thereby leading to radical changes in diagnostic and therapeutic pathways. We herein provide an up-to-date overview of the latest advances in endoscopic ultrasonography and small-bowel endoscopy, focusing on the emerging paradigms and technological innovations that might improve clinical practice in the near future.
Collapse
Affiliation(s)
- Gian Eugenio Tontini
- Gastroenterology and Endoscopy Unit, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.,Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | | | - Stefania Orlando
- Gastroenterology and Endoscopy Unit, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.,Digestive Endoscopy and Gastroenterology Unit, ASST of Cremona, Cremona, Italy
| | - Helmut Neumann
- Department of Medicine I, University Medical Center Mainz, Mainz, Germany
| | - Maurizio Vecchi
- Gastroenterology and Endoscopy Unit, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.,Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | | | - Luca Elli
- Gastroenterology and Endoscopy Unit, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| |
Collapse
|
14
|
Di Felice C, Young B, Matta M. Comparison of specimen adequacy and diagnostic accuracy of a 25-gauge and 22-gauge needle in endobronchial ultrasound-guided transbronchial needle aspiration. J Thorac Dis 2019; 11:3643-3649. [PMID: 31559072 DOI: 10.21037/jtd.2019.04.20] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Background Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the preferred diagnostic modality for sampling mediastinal and hilar lymph nodes (LNs). The conventional needle used for sampling is either a 21-gauge (21G) or 22-gauge (22G). A 25-gauge (25G) needle has recently been introduced with little known regarding its efficacy. Methods A retrospective study was conducted on patients referred for EBUS-TBNA who had LNs sampled using a 25G or 22G needle. A propensity score matching analysis was performed. After matching the groups, each LN was assessed for adequacy and final diagnosis. Non-diagnostic and benign lymphoid specimens were compared with repeat biopsy findings or long-term clinical and radiological follow-up. Results A total of 158 LNs were included. An adequate sample was obtained in 92.4% (73/79) in the 25G group and 92.4% (73/79) in the 22G group (P=1). The 25G group diagnosed benign lymphoid tissue in 82.3% (65/79), granuloma in 7.6% (6/79) and malignancy in 2.5% (2/79). Six lymph nodes in the 25G group were non-diagnostic (7.6%). The 22G group diagnosed benign lymphoid tissue in 83.5% (66/79), granuloma in 3.8% (3/79) and malignancy in 5.1% (4/79). Six lymph nodes in the 22G group were non-diagnostic (7.6%). The sensitivity, specificity, negative predictive value (NPV) and diagnostic accuracy in the 25G group was 88.9% (95% CI, 51.8-99.7%), 100% (95% CI, 92.1-100%), 97.8% (95% CI, 87.6-99.7%) and 98.2% (95% CI, 90.1-100%), respectively. The sensitivity, specificity, NPV and diagnostic accuracy in the 22G group was 77.8% (95% CI, 40-97.2%), 100% (95% CI, 86.8-100%), 92.9% (95% CI, 79.3-97.8%) and 94.3% (95% CI, 80.8-99.3%), respectively. The 25G and 22G group were comparable in diagnostic accuracy (P=0.7). Conclusions The 25G and 22G needle achieve comparable specimen adequacy and diagnostic accuracy in EBUS-TBNA.
Collapse
Affiliation(s)
- Christopher Di Felice
- University Hospitals Cleveland Medical Center, Department of Pulmonary, Critical Care and Sleep Medicine, Cleveland, Ohio, USA
| | - Benjamin Young
- University Hospitals Cleveland Medical Center, Department of Pulmonary, Critical Care and Sleep Medicine, Cleveland, Ohio, USA
| | - Maroun Matta
- University Hospitals Cleveland Medical Center, Department of Pulmonary, Critical Care and Sleep Medicine, Cleveland, Ohio, USA
| |
Collapse
|
15
|
Bor R, Vasas B, Fábián A, Bálint A, Farkas K, Milassin Á, Czakó L, Rutka M, Molnár T, Szűcs M, Tiszlavicz L, Kaizer L, Hamar S, Szepes Z. Prospective comparison of slow-pull and standard suction techniques of endoscopic ultrasound-guided fine needle aspiration in the diagnosis of solid pancreatic cancer. BMC Gastroenterol 2019; 19:6. [PMID: 30626331 PMCID: PMC6327397 DOI: 10.1186/s12876-018-0921-9] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2017] [Accepted: 12/10/2018] [Indexed: 12/13/2022] Open
Abstract
Background The usage of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for the diagnosis of solid pancreatic cancer is increasing, however mainly retrospective studies are available about the detailed methods of sampling. Methods To compare prospectively the diagnostic yield of EUS-FNA samples obtained with slow-pull (SP) and with standard suction technique (SS). Results EUS-FNA sampling was diagnostic in 72 of 92 cases (78.3%). Diagnostic yield was 67.4% in the SS and 65.2% in the SP group. The number of smear pairs (1.84 vs. 3.56; p < 0.001) and blood contamination (1.50 vs. 2.19; p < 0.001) were significantly higher in the SS group, which resulted in lower rate of diagnostic samples (41.8% vs. 30.0%; p = 0.003). There was no difference in the cellularity (1.58 vs. 1.37; p = 0.2554), or in the sensitivity and specificity in the identification of malignancy between SP and SS subgroups (69.9, 100% vs. 73.5, 100%). Histological samples were obtained in 60 cases (with SP: 49 cases; with SS: 46 cases). There was no difference in the diagnostic yield of histological samples between the groups (63 and 58.7%). Conclusion The diagnostic yield, the cellularity of smears and the rate of acquiring sufficient histological material are similar in the SP and SS group, but due to lower bloodiness and decreased number of slides, the pathological diagnosis is faster and more cost-effective.
Collapse
Affiliation(s)
- Renáta Bor
- First Department of Medicine, University of Szeged, Korányi Fasor 8-10, Szeged, 6720, Hungary
| | - Béla Vasas
- Department of Pathology, University of Szeged, Szeged, Hungary
| | - Anna Fábián
- First Department of Medicine, University of Szeged, Korányi Fasor 8-10, Szeged, 6720, Hungary
| | - Anita Bálint
- First Department of Medicine, University of Szeged, Korányi Fasor 8-10, Szeged, 6720, Hungary
| | - Klaudia Farkas
- First Department of Medicine, University of Szeged, Korányi Fasor 8-10, Szeged, 6720, Hungary
| | - Ágnes Milassin
- First Department of Medicine, University of Szeged, Korányi Fasor 8-10, Szeged, 6720, Hungary
| | - László Czakó
- First Department of Medicine, University of Szeged, Korányi Fasor 8-10, Szeged, 6720, Hungary
| | - Mariann Rutka
- First Department of Medicine, University of Szeged, Korányi Fasor 8-10, Szeged, 6720, Hungary
| | - Tamás Molnár
- First Department of Medicine, University of Szeged, Korányi Fasor 8-10, Szeged, 6720, Hungary
| | - Mónika Szűcs
- Department of Medical Physics and Informatics, University of Szeged, Szeged, Hungary
| | | | - László Kaizer
- Department of Pathology, University of Szeged, Szeged, Hungary
| | - Sándor Hamar
- Department of Pathology, University of Szeged, Szeged, Hungary
| | - Zoltán Szepes
- First Department of Medicine, University of Szeged, Korányi Fasor 8-10, Szeged, 6720, Hungary.
| |
Collapse
|
16
|
Abstract
EUS-guided tissue acquisition technique plays an essential role for evaluation of gastrointestinal tumors. Several components affect the yield of EUS-guided tissue acquisition outcomes such as sampling techniques, use of ROSE (rapid onsite evaluation), training and experience, and needle designs. In this review we discuss advancement in EUS-guided fine needle sampling.
Collapse
|
17
|
Tian G, Bao H, Li J, Jiang T. Systematic Review and Meta-Analysis of Diagnostic Accuracy of Endoscopic Ultrasound (EUS)-Guided Fine-Needle Aspiration (FNA) Using 22-gauge and 25-gauge Needles for Pancreatic Masses. Med Sci Monit 2018; 24:8333-8341. [PMID: 30452433 PMCID: PMC6257123 DOI: 10.12659/msm.911405] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Accepted: 07/10/2018] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has been used for detecting pancreatic cancer. We aimed to compare the diagnostic yield of both 22-gauge and 25-gauge EUS-FNA for the detection of pancreatic cancer. MATERIAL AND METHODS We searched the electronic databases including PubMed, EMBASE, Web of Science, Scopus, and Cochrane Library up to June 13, 2017. Two reviewers independently screened studies and extracted data. RESULTS We analyzed data from 1824 patients from 16 included studies. The estimated pooled data for the 22-gauge needles reported sensitivity was 0.89 (0.83-0.93), specificity was 1.00 (0.74-1.00), positive LR was 485.28 (2.55-92 000) and negative LR was 0.11 (0.07-0.17). Results for the 25-gauge needles showed the pooled sensitivity, specificity, positive and negative LR was 0.90 (0.86-0.93), 0.99 (0.89-1.00), 59.53 (7.99-443.66), and 0.10 (0.07-0.14), respectively. The 25-gauge needle had significantly higher pooled sensitivity than the 22-gauge needle (0.90 vs. 0.87, χ²=5.26, P=0.02) while there was no difference in the pooled specificity (0.96 vs. 0.98, χ²=2.12, P=0.15). The quality of most studies was assessed favorable using QUADAS-2 (quality assessment of diagnostic accuracy studies-2). CONCLUSIONS Our findings revealed that the 25-gauge EUS-FNA used for pancreatic lesions could have a higher diagnostic yield than using 22-gauge EUS-FNA. Nevertheless, well-designed prospective studies recruiting more patients are needed.
Collapse
Affiliation(s)
- Guo Tian
- Department of Ultrasound Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, P.R. China
- Key Laboratory of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Tumor of Zhejiang Province, Hangzhou, Zhejiang, P.R. China
| | - Haiwei Bao
- Department of Hepatobiliary and Pancreatic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, P.R. China
| | - Ju Li
- Department of Hepatobiliary and Pancreatic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, P.R. China
| | - Tian’an Jiang
- Department of Ultrasound Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, P.R. China
- Key Laboratory of Precision Diagnosis and Treatment for Hepatobiliary and Pancreatic Tumor of Zhejiang Province, Hangzhou, Zhejiang, P.R. China
| |
Collapse
|
18
|
Lee JM, Lee HS, Hyun JJ, Lee JM, Yoo IK, Kim SH, Choi HS, Kim ES, Keum B, Seo YS, Jeen YT, Chun HJ, Um SH, Kim CD. Slow-Pull Using a Fanning Technique Is More Useful Than the Standard Suction Technique in EUS-Guided Fine Needle Aspiration in Pancreatic Masses. Gut Liver 2018; 12:360-366. [PMID: 29409303 PMCID: PMC5945268 DOI: 10.5009/gnl17140] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2017] [Revised: 09/09/2017] [Accepted: 09/20/2017] [Indexed: 12/21/2022] Open
Abstract
Background/Aims Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is useful for obtaining pancreatic mass samples. The combination of modified techniques (i.e., slow-pull technique and fanning technique) may improve the quality of the sample obtained by EUS-FNA. We investigated the effectiveness of a combined slow-pull fanning technique in EUS-FNA for pancreatic mass. Methods This prospective comparative study investigated EUS-FNA performed for pancreatic solid masses between August 2015 and July 2016. Pairwise specimens were alternately obtained using the following two techniques for targeted pancreatic lesions: standard suction or slow-pull with fanning. We compared the specimen quality, blood contamination, and diagnostic accuracy of these techniques. Results Forty-eight consecutive patients were included (29 men; mean age, 68.1±11.9 years), and 96 pancreatic mass specimens were obtained. The slow-pull with fanning technique had a significantly superior diagnostic accuracy than the suction technique (88% vs 71%, p=0.044). Furthermore, blood contamination was significantly reduced using the slow-pull with fanning technique (ratio of no or slight contamination, 77% vs 56%, p=0.041). No difference was observed in the acquisition of adequate cellularity between the groups. In the subgroup analysis, the tumor size and sampling technique were related to the EUS-FNA diagnostic accuracy. Conclusions The slow-pull with needle fanning technique showed a good diagnostic yield for EUS-FNA for pancreatic mass. This technique can be useful for performing EUS-guided sampling for diagnosing pancreatic disease.
Collapse
Affiliation(s)
- Jae Min Lee
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Hong Sik Lee
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Jong Jin Hyun
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Jung Min Lee
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - In Kyung Yoo
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Seung Han Kim
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Hyuk Soon Choi
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Eun Sun Kim
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Bora Keum
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Yeon Seok Seo
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Yoon Tae Jeen
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Hoon Jai Chun
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Soon Ho Um
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| | - Chang Duck Kim
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
| |
Collapse
|
19
|
Cazacu IM, Luzuriaga Chavez AA, Saftoiu A, Vilmann P, Bhutani MS. A quarter century of EUS-FNA: Progress, milestones, and future directions. Endosc Ultrasound 2018; 7:141-160. [PMID: 29941723 PMCID: PMC6032705 DOI: 10.4103/eus.eus_19_18] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Accepted: 03/21/2018] [Indexed: 12/11/2022] Open
Abstract
Tissue acquisition using EUS has considerably evolved since the first EUS-FNA was reported 25 years ago. Its introduction was an important breakthrough in the endoscopic field. EUS-FNA has now become a part of the diagnostic and staging algorithm for the evaluation of benign and malignant diseases of the gastrointestinal tract and of the organs in its proximity, including lung diseases. This review aims to present the history of EUS-FNA development and to provide a perspective on the recent developments in procedural techniques and needle technologies that have significantly extended the role of EUS and its clinical applications. There is a bright future ahead for EUS-FNA in the years to come as extensive research is conducted in this field and various technologies are continuously implemented into clinical practice.
Collapse
Affiliation(s)
- Irina Mihaela Cazacu
- Department of Gastroenterology, Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy, Craiova, Romania
- Department of Gastroenterology, Hepatology, and Nutrition, University of Texas – MD Anderson Cancer Center, Houston, Texas, USA
| | | | - Adrian Saftoiu
- Department of Gastroenterology, Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy, Craiova, Romania
| | - Peter Vilmann
- Gastrounit, Division of Surgery, Copenhagen University Hospital Herlev, Copenhagen, Denmark
| | - Manoop S. Bhutani
- Department of Gastroenterology, Hepatology, and Nutrition, University of Texas – MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
20
|
Guedes HG, de Moura DTH, Duarte RB, Cordero MAC, dos Santos MEL, Cheng S, Matuguma SE, Chaves DM, Bernardo WM, de Moura EGH. A comparison of the efficiency of 22G versus 25G needles in EUS-FNA for solid pancreatic mass assessment: A systematic review and meta-analysis. Clinics (Sao Paulo) 2018; 73:e261. [PMID: 29451621 PMCID: PMC5773825 DOI: 10.6061/clinics/2018/e261] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Accepted: 10/31/2017] [Indexed: 12/17/2022] Open
Abstract
Our aim in this study was to compare the efficiency of 25G versus 22G needles in diagnosing solid pancreatic lesions by EUS-FNA. We performed a systematic review and meta-analysis. Studies were identified in five databases using an extensive search strategy. Only randomized trials comparing 22G and 25G needles were included. The results were analyzed by fixed and random effects. A total of 504 studies were found in the search, among which 4 randomized studies were selected for inclusion in the analysis. A total of 462 patients were evaluated (233: 25G needle/229: 22G needle). The diagnostic sensitivity was 93% for the 25G needle and 91% for the 22G needle. The specificity of the 25G needle was 87%, and that of the 22G needle was 83%. The positive likelihood ratio was 4.57 for the 25G needle and 4.26 for the 22G needle. The area under the sROC curve for the 25G needle was 0.9705, and it was 0.9795 for the 22G needle, with no statistically significant difference between them (p=0.497). Based on randomized studies, this meta-analysis did not demonstrate a significant difference between the 22G and 25G needles used during EUS-FNA in the diagnosis of solid pancreatic lesions.
Collapse
Affiliation(s)
- Hugo Gonçalo Guedes
- Divisao de Endoscopia Gastrointestinal, Faculdade de Medicina FMUSP, Universidade de Sao Paulo, Sao Paulo, SP, BR
- *Corresponding author. E-mail:
| | | | - Ralph Braga Duarte
- Divisao de Endoscopia Gastrointestinal, Faculdade de Medicina FMUSP, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | | | | | - Spencer Cheng
- Divisao de Endoscopia Gastrointestinal, Faculdade de Medicina FMUSP, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | - Sergio Eiji Matuguma
- Divisao de Endoscopia Gastrointestinal, Faculdade de Medicina FMUSP, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | - Dalton Marques Chaves
- Divisao de Endoscopia Gastrointestinal, Faculdade de Medicina FMUSP, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | - Wanderley Marques Bernardo
- Divisao de Endoscopia Gastrointestinal, Faculdade de Medicina FMUSP, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | | |
Collapse
|
21
|
El Hajj II, Al-Haddad M. Endoscopic ultrasound-guided tissue acquisition of pancreatic masses. TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY 2018. [DOI: 10.1016/j.tgie.2018.01.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
22
|
Abstract
Endoscopic ultrasound (EUS)-guided tissue acquisition has greatly evolved since the first EUS-guided fine-needle aspiration was reported nearly 25 years ago. EUS-guided tissue acquisition has become the procedure of choice for sampling of the pancreas, subepithelial lesions, and other structures adjacent to the gastrointestinal tract. This review focuses on recent developments in procedural techniques and needle technologies for EUS-guided tissue acquisition.
Collapse
|
23
|
Best LMJ, Rawji V, Pereira SP, Davidson BR, Gurusamy KS. Imaging modalities for characterising focal pancreatic lesions. Cochrane Database Syst Rev 2017; 4:CD010213. [PMID: 28415140 PMCID: PMC6478242 DOI: 10.1002/14651858.cd010213.pub2] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
BACKGROUND Increasing numbers of incidental pancreatic lesions are being detected each year. Accurate characterisation of pancreatic lesions into benign, precancerous, and cancer masses is crucial in deciding whether to use treatment or surveillance. Distinguishing benign lesions from precancerous and cancerous lesions can prevent patients from undergoing unnecessary major surgery. Despite the importance of accurately classifying pancreatic lesions, there is no clear algorithm for management of focal pancreatic lesions. OBJECTIVES To determine and compare the diagnostic accuracy of various imaging modalities in detecting cancerous and precancerous lesions in people with focal pancreatic lesions. SEARCH METHODS We searched the CENTRAL, MEDLINE, Embase, and Science Citation Index until 19 July 2016. We searched the references of included studies to identify further studies. We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. SELECTION CRITERIA We planned to include studies reporting cross-sectional information on the index test (CT (computed tomography), MRI (magnetic resonance imaging), PET (positron emission tomography), EUS (endoscopic ultrasound), EUS elastography, and EUS-guided biopsy or FNA (fine-needle aspiration)) and reference standard (confirmation of the nature of the lesion was obtained by histopathological examination of the entire lesion by surgical excision, or histopathological examination for confirmation of precancer or cancer by biopsy and clinical follow-up of at least six months in people with negative index tests) in people with pancreatic lesions irrespective of language or publication status or whether the data were collected prospectively or retrospectively. DATA COLLECTION AND ANALYSIS Two review authors independently searched the references to identify relevant studies and extracted the data. We planned to use the bivariate analysis to calculate the summary sensitivity and specificity with their 95% confidence intervals and the hierarchical summary receiver operating characteristic (HSROC) to compare the tests and assess heterogeneity, but used simpler models (such as univariate random-effects model and univariate fixed-effect model) for combining studies when appropriate because of the sparse data. We were unable to compare the diagnostic performance of the tests using formal statistical methods because of sparse data. MAIN RESULTS We included 54 studies involving a total of 3,196 participants evaluating the diagnostic accuracy of various index tests. In these 54 studies, eight different target conditions were identified with different final diagnoses constituting benign, precancerous, and cancerous lesions. None of the studies was of high methodological quality. None of the comparisons in which single studies were included was of sufficiently high methodological quality to warrant highlighting of the results. For differentiation of cancerous lesions from benign or precancerous lesions, we identified only one study per index test. The second analysis, of studies differentiating cancerous versus benign lesions, provided three tests in which meta-analysis could be performed. The sensitivities and specificities for diagnosing cancer were: EUS-FNA: sensitivity 0.79 (95% confidence interval (CI) 0.07 to 1.00), specificity 1.00 (95% CI 0.91 to 1.00); EUS: sensitivity 0.95 (95% CI 0.84 to 0.99), specificity 0.53 (95% CI 0.31 to 0.74); PET: sensitivity 0.92 (95% CI 0.80 to 0.97), specificity 0.65 (95% CI 0.39 to 0.84). The third analysis, of studies differentiating precancerous or cancerous lesions from benign lesions, only provided one test (EUS-FNA) in which meta-analysis was performed. EUS-FNA had moderate sensitivity for diagnosing precancerous or cancerous lesions (sensitivity 0.73 (95% CI 0.01 to 1.00) and high specificity 0.94 (95% CI 0.15 to 1.00), the extremely wide confidence intervals reflecting the heterogeneity between the studies). The fourth analysis, of studies differentiating cancerous (invasive carcinoma) from precancerous (dysplasia) provided three tests in which meta-analysis was performed. The sensitivities and specificities for diagnosing invasive carcinoma were: CT: sensitivity 0.72 (95% CI 0.50 to 0.87), specificity 0.92 (95% CI 0.81 to 0.97); EUS: sensitivity 0.78 (95% CI 0.44 to 0.94), specificity 0.91 (95% CI 0.61 to 0.98); EUS-FNA: sensitivity 0.66 (95% CI 0.03 to 0.99), specificity 0.92 (95% CI 0.73 to 0.98). The fifth analysis, of studies differentiating cancerous (high-grade dysplasia or invasive carcinoma) versus precancerous (low- or intermediate-grade dysplasia) provided six tests in which meta-analysis was performed. The sensitivities and specificities for diagnosing cancer (high-grade dysplasia or invasive carcinoma) were: CT: sensitivity 0.87 (95% CI 0.00 to 1.00), specificity 0.96 (95% CI 0.00 to 1.00); EUS: sensitivity 0.86 (95% CI 0.74 to 0.92), specificity 0.91 (95% CI 0.83 to 0.96); EUS-FNA: sensitivity 0.47 (95% CI 0.24 to 0.70), specificity 0.91 (95% CI 0.32 to 1.00); EUS-FNA carcinoembryonic antigen 200 ng/mL: sensitivity 0.58 (95% CI 0.28 to 0.83), specificity 0.51 (95% CI 0.19 to 0.81); MRI: sensitivity 0.69 (95% CI 0.44 to 0.86), specificity 0.93 (95% CI 0.43 to 1.00); PET: sensitivity 0.90 (95% CI 0.79 to 0.96), specificity 0.94 (95% CI 0.81 to 0.99). The sixth analysis, of studies differentiating cancerous (invasive carcinoma) from precancerous (low-grade dysplasia) provided no tests in which meta-analysis was performed. The seventh analysis, of studies differentiating precancerous or cancerous (intermediate- or high-grade dysplasia or invasive carcinoma) from precancerous (low-grade dysplasia) provided two tests in which meta-analysis was performed. The sensitivity and specificity for diagnosing cancer were: CT: sensitivity 0.83 (95% CI 0.68 to 0.92), specificity 0.83 (95% CI 0.64 to 0.93) and MRI: sensitivity 0.80 (95% CI 0.58 to 0.92), specificity 0.81 (95% CI 0.53 to 0.95), respectively. The eighth analysis, of studies differentiating precancerous or cancerous (intermediate- or high-grade dysplasia or invasive carcinoma) from precancerous (low-grade dysplasia) or benign lesions provided no test in which meta-analysis was performed.There were no major alterations in the subgroup analysis of cystic pancreatic focal lesions (42 studies; 2086 participants). None of the included studies evaluated EUS elastography or sequential testing. AUTHORS' CONCLUSIONS We were unable to arrive at any firm conclusions because of the differences in the way that study authors classified focal pancreatic lesions into cancerous, precancerous, and benign lesions; the inclusion of few studies with wide confidence intervals for each comparison; poor methodological quality in the studies; and heterogeneity in the estimates within comparisons.
Collapse
Affiliation(s)
- Lawrence MJ Best
- Royal Free Campus, UCL Medical SchoolDepartment of SurgeryRowland Hill StreetLondonUKNW32PF
| | - Vishal Rawji
- University College London Medical SchoolLondonUK
| | - Stephen P Pereira
- Royal Free Hospital CampusUCL Institute for Liver and Digestive HealthUpper 3rd FloorLondonUKNW3 2PF
| | - Brian R Davidson
- Royal Free Campus, UCL Medical SchoolDepartment of SurgeryRowland Hill StreetLondonUKNW32PF
| | | | | |
Collapse
|
24
|
Xu MM, Jia HY, Yan LL, Li SS, Zheng Y. Comparison of two different size needles in endoscopic ultrasound-guided fine-needle aspiration for diagnosing solid pancreatic lesions: A meta-analysis of prospective controlled trials. Medicine (Baltimore) 2017; 96:e5802. [PMID: 28151856 PMCID: PMC5293419 DOI: 10.1097/md.0000000000005802] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND This meta-analysis aimed to provide a pooled analysis of prospective controlled trials comparing the diagnostic accuracy of 22-G and 25-G needles on endoscopic ultrasonography (EUS-FNA) of the solid pancreatic mass. METHODS We established a rigorous study protocol according to Cochrane Collaboration recommendations. We systematically searched the PubMed and Embase databases to identify articles to include in the meta-analysis. Sensitivity, specificity, and corresponding 95% confidence intervals were calculated for 22-G and 25-G needles of individual studies from the contingency tables. RESULTS Eleven prospective controlled trials included a total of 837 patients (412 with 22-G vs 425 with 25-G). Our outcomes revealed that 25-G needles (92% [95% CI, 89%-95%]) have higher sensitivity than 22-G needles (88% [95% CI, 84%-91%]) on solid pancreatic mass EUS-FNA (P = 0.046). However, there were no significant differences between the 2 groups in overall diagnostic specificity (P = 0.842). The pooled positive and negative likelihood ratio of the 22-G needle were 12.61 (95% CI, 5.65-28.14) and 0.16 (95% CI, 0.12-0.21), respectively. The pooled positive likelihood ratio was 12.61 (95% CI, 5.65-28.14), and the negative likelihood ratio was 0.16 (95% CI, 0.12-0.21) for the 22-G needle. The pooled positive likelihood ratio was 8.44 (95% CI, 3.87-18.42), and the negative likelihood ratio was 0.13 (95% CI, 0.09-0.18) for the 25-G needle. The area under the summary receiver operating characteristic curve was 0.97 for the 22-G needle and 0.96 for the 25-G needle. CONCLUSION Compared to the study of 22-G EUS-FNA needles, our study showed that 25-G needles have superior sensitivity in the evaluation of solid pancreatic lesions by EUS-FNA.
Collapse
|
25
|
Facciorusso A, Stasi E, Di Maso M, Serviddio G, Ali Hussein MS, Muscatiello N. Endoscopic ultrasound-guided fine needle aspiration of pancreatic lesions with 22 versus 25 Gauge needles: A meta-analysis. United European Gastroenterol J 2016; 5:846-853. [PMID: 29026598 DOI: 10.1177/2050640616680972] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2016] [Accepted: 10/24/2016] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Robust data in favour of a clear superiority of 22 versus 25 Gauge needles for endoscopic ultrasound-guided fine needle aspiration are still lacking. OBJECTIVE We aimed to compare the diagnostic sensitivity, specificity and safety of these two needles for endoscopic ultrasound-guided fine needle aspiration of solid pancreatic lesions. METHODS A computerized bibliographic search was restricted to randomized controlled trials only. Pooled effects were calculated using a random-effects model and expressed in terms of risk ratio and 95% confidence interval. RESULTS We analysed seven trials with 689 patients and 732 lesions (295 sampled with 22 Gauge needle, 309 with 25 Gauge needle, and 128 with both needles). A non-significant superiority of 25 Gauge in terms of pooled sensitivity (risk ratio: 0.93, 0.91-0.95 versus 0.89, 0.85-0.94 of 22 Gauge needle; p = 0.13) and no difference in terms of specificity (1.00, 0.98-1.00 in both groups; p = 0.85) were observed. Sample adequacy was similar between the two devices (risk ratio: 1.03, 0.99-1.06; p = 0.15). Very few adverse events were observed and did not impact on patient outcomes. CONCLUSION Our meta-analysis reveals non-superiority of 25 Gauge over 22 Gauge; hence no definitive recommendations over the use of one particular device can be made.
Collapse
Affiliation(s)
- Antonio Facciorusso
- Gastroenterology Unit, Department of Medical Sciences, University of Foggia, Foggia, Italy
| | - Elisa Stasi
- Gastroenterology Unit, IRCCS Saverio De Bellis, Castellana Grotte (Ba), Italy
| | - Marianna Di Maso
- Gastroenterology Unit, Department of Medical Sciences, University of Foggia, Foggia, Italy
| | | | - Mohammed Salah Ali Hussein
- Gastroenterology Unit, Department of Medical Sciences, University of Foggia, Foggia, Italy.,Department of Internal Medicine, Al-Azhar University, Cairo, Egypt
| | - Nicola Muscatiello
- Gastroenterology Unit, Department of Medical Sciences, University of Foggia, Foggia, Italy
| |
Collapse
|
26
|
Oh HC, Kang H, Lee JY, Choi GJ, Choi JS. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis. Korean J Intern Med 2016; 31:1073-1083. [PMID: 27586867 PMCID: PMC5094933 DOI: 10.3904/kjim.2016.066] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Revised: 06/13/2016] [Accepted: 06/28/2016] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND/AIMS To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. METHODS Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. RESULTS The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). CONCLUSIONS Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.
Collapse
Affiliation(s)
- Hyoung-Chul Oh
- Division of Gastroenterology, Department of Internal Medicine, Chung-Ang University College of Medicine, Seoul, Korea
- Correspondence to Hyoung-Chul Oh, M.D. Division of Gastroenterology, Department of Internal Medicine, Chung-Ang University College of Medicine, 102 Heukseok-ro, Dongjak-gu, Seoul 06973, Korea Tel: +82-2-6299-3149 Fax: +82-2-6299-2040 E-mail:
| | - Hyun Kang
- Department of Anesthesiology, Chung-Ang University College of Medicine, Seoul, Korea
| | - Jae Young Lee
- Division of Gastroenterology, Department of Internal Medicine, Chung-Ang University College of Medicine, Seoul, Korea
| | - Geun Joo Choi
- Department of Anesthesiology, Chung-Ang University College of Medicine, Seoul, Korea
| | - Jung Sik Choi
- Division of Gastroenterology, Department of Internal Medicine, Inje University Busan Paik Hospital, Busan, Korea
| |
Collapse
|
27
|
Ishiwatari H, Hayashi T, Kawakami H, Isayama H, Hisai H, Itoi T, Ono M, Kawakubo K, Yamamoto N, Tanaka M, Itokawa F, Oshiro H, Sonoda T, Hasegawa T. Randomized trial comparing a side-port needle and standard needle for EUS-guided histology of pancreatic lesions. Gastrointest Endosc 2016; 84:670-8. [PMID: 26995688 DOI: 10.1016/j.gie.2016.03.1329] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2015] [Accepted: 03/06/2016] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS A side-port needle has been developed to improve diagnostic accuracy by obtaining more cellular material during EUS-guided FNA (EUS-FNA). We compared the accuracy rate of histology and the quality of histologic specimens from 22-gauge (G) side-port and standard needles for EUS-FNA of a solid pancreatic mass in a multicenter, prospective, randomized control trial. METHODS Between January 2013 and September 2013, 160 consecutive patients with a suspected solid pancreatic mass at 5 tertiary referral centers were enrolled. Patients were randomized to the 22G side-port needle or 22G standard needle group. The primary endpoint was the diagnostic accuracy of histology. Secondary endpoints were the quality of the histologic specimen (quantity of tissue, degree of GI contamination, and amount of blood). RESULTS An analysis of 154 patients (side-port, 76, vs standard, 78) was performed. Six patients were excluded because of no pancreatic mass on EUS. There was no significant difference in the rate of diagnostic accuracy of histology (side-port, 87% [66/76], vs standard, 82% [64/78]; P = .51). Samples that enabled histologic interpretation were obtained in 64% (47/73) and 43% (33/77) of patients from the side-port and standard groups, respectively (P = .009). No significant difference was seen in the degree of GI contamination and amount of blood between groups. CONCLUSIONS There was no significant difference in the accuracy rate of histology between needle types. The side-port needle was superior to the standard needle in terms of obtaining samples that enabled histologic interpretation.
Collapse
Affiliation(s)
- Hirotoshi Ishiwatari
- Department of Medical Oncology and Hematology, Sapporo Medical University, Sapporo, Japan
| | - Tsuyoshi Hayashi
- Department of Medical Oncology and Hematology, Sapporo Medical University, Sapporo, Japan
| | - Hiroshi Kawakami
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Sapporo, Japan
| | - Hiroyuki Isayama
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Hiroyuki Hisai
- Department of Gastroenterology, Japanese Red Cross Date General Hospital, Hokkaido, Japan
| | - Takao Itoi
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Michihiro Ono
- Department of Medical Oncology and Hematology, Sapporo Medical University, Sapporo, Japan
| | - Kazumichi Kawakubo
- Department of Gastroenterology and Hepatology, Hokkaido University Hospital, Sapporo, Japan
| | - Natsuyo Yamamoto
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Mariko Tanaka
- Department of Pathology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Fumihide Itokawa
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Hisashi Oshiro
- Department of Pathology, Tokyo Medical University, Tokyo, Japan
| | - Tomoko Sonoda
- Department of Public Health, Sapporo Medical University School of Medicine, Sapporo, Japan
| | - Tadashi Hasegawa
- Department of Surgical Pathology, Sapporo Medical University School of Medicine, Sapporo, Japan
| | | |
Collapse
|
28
|
Yamabe A, Irisawa A, Bhutani MS, Shibukawa G, Fujisawa M, Sato A, Yoshida Y, Arakawa N, Ikeda T, Igarashi R, Maki T, Yamamoto S. Efforts to improve the diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration for pancreatic tumors. Endosc Ultrasound 2016; 5:225-32. [PMID: 27503153 PMCID: PMC4989402 DOI: 10.4103/2303-9027.187862] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2016] [Accepted: 06/09/2016] [Indexed: 02/06/2023] Open
Abstract
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is widely used to obtain a definitive diagnosis of pancreatic tumors. Good results have been reported for its diagnostic accuracy, with high sensitivity and specificity of around 90%; however, technological developments and adaptations to improve it still further are currently underway. The endosonographic technique can be improved when several tips and tricks useful to overcome challenges of EUS-FNA are known. This review provides various techniques and equipment for improvement in the diagnostic accuracy in EUS-FNA.
Collapse
Affiliation(s)
- Akane Yamabe
- Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan
| | - Atsushi Irisawa
- Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan
| | | | - Goro Shibukawa
- Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan
| | - Mariko Fujisawa
- Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan
| | - Ai Sato
- Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan
| | | | - Noriyuki Arakawa
- Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan
| | - Tsunehiko Ikeda
- Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan
| | - Ryo Igarashi
- Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan
| | - Takumi Maki
- Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan
| | - Shogo Yamamoto
- Aizu Medical Center, Fukushima Medical University, Aizuwakamatsu, Japan
| |
Collapse
|
29
|
Park SW, Chung MJ, Lee SH, Lee HS, Lee HJ, Park JY, Park SW, Song SY, Kim H, Chung JB, Bang S. Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses. PLoS One 2016; 11:e0154401. [PMID: 27149404 PMCID: PMC4858215 DOI: 10.1371/journal.pone.0154401] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2015] [Accepted: 04/13/2016] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND AND AIMS Although thicker needles theoretically allow more tissue to be collected, their decreased flexibility can cause mechanical damage to the endoscope, technical failure, and sample blood contamination. The effects of needle gauge on diagnostic outcomes of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of pancreatic mass lesions remain unknown. This study compared procurement rates of histologic cores obtained from EUS-FNB of pancreatic masses using 25- and 22-gauge core biopsy needles. PATIENTS AND METHODS From March 2014 to July 2014, 66 patients with solid pancreatic mass underwent EUS-FNB with both 25- and 22-gauge core biopsy needles. Among them, 10 patients were excluded and thus 56 patients were eligible for the analyses. Needle sequences were randomly assigned, and two passes were made with each needle, consisting of 10 uniform to-and-fro movements on each pass with 10 mL syringe suction. A pathologist blinded to needle sequence evaluated specimens for the presence of histologic core. RESULTS The mean patient age was 65.8 ± 9.5 years (range, 44-89 years); 35 patients (62.5%) were men. The mean pancreatic mass size was 35.3 ± 17.1 mm (range 14-122.3 mm). Twenty-eight patients (50%) had tumors at the pancreas head or uncinate process. There were no significant differences in procurement rates of histologic cores between 25-gauge (49/56, 87.5%) and 22-gauge (46/56, 82.1%, P = 0.581) needles or diagnostic accuracy using only histologic cores (98% and 95%). There were no technical failures or procedure-related adverse events. CONCLUSIONS The 25-gauge core biopsy needle could offer acceptable and comparable outcomes regarding diagnostic performance including histologic core procurement rates compared to the 22-gauge core biopsy needle, although the differences were not statistically significant. TRIAL REGISTRATION ClinicalTrials.gov NCT01795066.
Collapse
Affiliation(s)
- Se Woo Park
- Division of Gastroenterology, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Gyeonggi-do, Korea
| | - Moon Jae Chung
- Division of Gastroenterology, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Sang Hoon Lee
- Division of Gastroenterology, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Hee Seung Lee
- Division of Gastroenterology, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Hyun Jik Lee
- Division of Gastroenterology, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Jeong Yup Park
- Division of Gastroenterology, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Seung Woo Park
- Division of Gastroenterology, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Si Young Song
- Division of Gastroenterology, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Hoguen Kim
- Department of Pathology and Brain Korea 21 Projects for Medical Science, Yonsei University College of Medicine, Seoul, Korea
| | - Jae Bock Chung
- Division of Gastroenterology, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Seungmin Bang
- Division of Gastroenterology, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
30
|
Kamata K, Kitano M, Omoto S, Kadosaka K, Miyata T, Minaga K, Yamao K, Imai H, Kudo M. New endoscopic ultrasonography techniques for pancreaticobiliary diseases. Ultrasonography 2016; 35:169-79. [PMID: 27214660 PMCID: PMC4939715 DOI: 10.14366/usg.15042] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Revised: 04/10/2016] [Accepted: 04/12/2016] [Indexed: 12/20/2022] Open
Abstract
Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS. EUS-guided fine needle aspiration (EUS-FNA) has been used for diagnosing pancreatic tumors. In order to improve the histological diagnostic yield, a EUS-FNA needle with a core trap has recently been developed. Contrast-enhanced harmonic EUS is a new imaging modality that uses an ultrasonographic contrast agent to visualize blood flow in fine vessels. This technique is useful in the diagnosis of pancreatic solid lesions and in confirming the presence of vascularity in mural nodules for cystic lesions. EUS elastography analyzes several different variables to measure tissue elasticity, color patterns, and strain ratio, using analytical techniques such as hue-histogram analysis, and artificial neural networks, which are useful for the diagnosis of chronic pancreatitis and pancreatic cancer.
Collapse
Affiliation(s)
- Ken Kamata
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Masayuki Kitano
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Shunsuke Omoto
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Kumpei Kadosaka
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Takeshi Miyata
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Kosuke Minaga
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Kentaro Yamao
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Hajime Imai
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| | - Masatoshi Kudo
- Department of Gastroenterology and Hepatology, Kinki University Faculty of Medicine, Osaka-Sayama, Japan
| |
Collapse
|
31
|
Ikeura T, Takaoka M, Uchida K, Shimatani M, Miyoshi H, Kato K, Ohe C, Uemura Y, Kaibori M, Kwon AH, Okazaki K. Fluorescence cytology with 5-aminolevulinic acid in EUS-guided FNA as a method for differentiating between malignant and benign lesions (with video). Gastrointest Endosc 2016; 81:1457-62. [PMID: 25865388 DOI: 10.1016/j.gie.2015.01.031] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2014] [Accepted: 01/11/2015] [Indexed: 12/11/2022]
Abstract
BACKGROUND EUS-guided FNA (EUS-FNA) has been increasingly performed to obtain specimens for the pathological evaluation of patients with GI and pancreaticobiliary masses as well as lymphadenopathies of unknown origin. Photodynamic diagnosis by using 5-aminolebulinic acid (ALA) has been reported to be useful for enabling the visual differentiation between malignant and normal tissue in various cancers. OBJECTIVE To evaluate the diagnostic accuracy of fluorescence cytology with ALA in EUS-FNA. DESIGN A prospective study. SETTING A single center. PATIENTS A total of 28 consecutive patients who underwent EUS-FNA for the pathological diagnosis of a pancreaticobiliary mass lesion or intra-abdominal lymphadenopathy of unknown origin. INTERVENTIONS Patients were orally administered ALA 3 to 6 hours before EUS-FNA. The sample was obtained via EUS-FNA for fluorescence cytology and conventional cytology. A single gastroenterologist performed the fluorescence cytology by using fluorescence microscopy after the procedure, independently of the conventional cytology by pathologists. MAIN OUTCOME MEASUREMENTS The accuracy of fluorescence cytology with ALA in the differentiation between benign and malignant lesions by comparing the results of fluorescence cytology with the final diagnosis. RESULTS Of the 28 patients included in the study, 22 were considered as having malignant lesions and 6 patients as having benign lesions. Fluorescence cytology could correctly discriminate between benign and malignant lesions in all patients. Therefore, both the sensitivity and specificity of fluorescence cytology were 100% in our study. LIMITATIONS Fluorescence cytology was performed by only 1 gastroenterologist with a small number of patients. CONCLUSION Fluorescence cytology with ALA in EUS-FNA may be an effective and simple method for differentiating between benign and malignant lesions.
Collapse
Affiliation(s)
- Tsukasa Ikeura
- The Third Department of Internal Medicine, Kansai Medical University, Osaka, Japan
| | - Makoto Takaoka
- The Third Department of Internal Medicine, Kansai Medical University, Osaka, Japan
| | - Kazushige Uchida
- The Third Department of Internal Medicine, Kansai Medical University, Osaka, Japan
| | - Masaaki Shimatani
- The Third Department of Internal Medicine, Kansai Medical University, Osaka, Japan
| | - Hideaki Miyoshi
- The Third Department of Internal Medicine, Kansai Medical University, Osaka, Japan
| | - Kota Kato
- The Third Department of Internal Medicine, Kansai Medical University, Osaka, Japan
| | - Chisato Ohe
- Department of Pathology, Kansai Medical University, Hirakata Hospital, Osaka, Japan
| | - Yoshiko Uemura
- Department of Pathology, Kansai Medical University, Hirakata Hospital, Osaka, Japan
| | - Masaki Kaibori
- Department of Surgery, Kansai Medical University, Osaka, Japan
| | - A-Hon Kwon
- Department of Surgery, Kansai Medical University, Osaka, Japan
| | - Kazuichi Okazaki
- The Third Department of Internal Medicine, Kansai Medical University, Osaka, Japan
| |
Collapse
|
32
|
Eliminating the Residual Negative Pressure in the Endoscopic Ultrasound Aspirating Needle Enhances Cytology Yield of Pancreas Masses. Dig Dis Sci 2016; 61:890-9. [PMID: 26346997 PMCID: PMC4976479 DOI: 10.1007/s10620-015-3860-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2015] [Accepted: 08/25/2015] [Indexed: 12/20/2022]
Abstract
BACKGROUND Prior to withdrawing the EUS-FNA needle from the lesion, the stopcock of the suction syringe is closed to reduce contamination. Residual negative pressure (RNP) may persist in the needle despite closing the stopcock. AIMS To determine whether neutralizing RNP before withdrawing the needle will improve the cytology yield. METHODS Bench-top testing was done to confirm the presence of RNP followed by a prospective, randomized, cross-over study on patients with pancreas mass. Ten milliliters of suction was applied to the FNA needle. Before withdrawing the needle from the lesion, the stopcock was closed. Based on randomization, the first pass was done with the stopcock either attached to the needle (S+) or disconnected (S-) to allow air to enter and neutralize RNP and accordingly the second pass was crossed over to S+ or S-. On-site cytopathologist was blinded to S+/S-. RESULTS Bench tests confirmed the presence of RNP which was successfully neutralized by disconnecting the syringe (S-) from the needle. Sixty patients were enrolled, 120 samples analyzed. S+ samples showed significantly greater GI tract contamination compared to S- samples (16.7 vs. 6.7%, p = 0.03). Of the 53 patients confirmed to have pancreas adenocarcinoma, FNA using S- approach was positive in 49 (93%) compared to 40 using the S+ approach (76%, p = 0.02). CONCLUSIONS Despite closing the stopcock of the suction syringe, RNP is present in the FNA needle. Neutralizing RNP prior to withdrawing the needle from the target lesion significantly decreased GI tract contamination of the sample thereby improving the FNA cytology yield. CLINICAL TRIALS REGISTRATION NUMBER NCT01995474.
Collapse
|
33
|
Carrara S, Anderloni A, Jovani M, Di Tommaso L, Rahal D, Hassan C, Ridola L, Federico D, Loriga A, Repici A. A prospective randomized study comparing 25-G and 22-G needles of a new platform for endoscopic ultrasound-guided fine needle aspiration of solid masses. Dig Liver Dis 2016; 48:49-54. [PMID: 26607829 DOI: 10.1016/j.dld.2015.09.017] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2015] [Revised: 09/18/2015] [Accepted: 09/27/2015] [Indexed: 12/11/2022]
Abstract
BACKGROUND A new needle platform for endoscopic ultrasound-guided fine-needle aspiration biopsy has been developed that allows interchangeability of all needle sizes. AIMS To prospectively compare the efficacy of the new 25-G needles and 22-G needles for obtaining an adequate aspirate of solid masses. METHODS Randomized controlled trial of 144 patients referred for endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic masses, intraparietal tumours, or lymph-nodes, randomized to the 25-G or 22-G needle arms. RESULTS An adequate specimen was obtained from 74.3% of cases. The sample tended to be more adequate in the 25-G compared to the 22-G group (81% vs. 68%; p=0.09). Crossover was required in 14 (19%) and 12 (17%) cases in the 22-G and in the 25-G groups, respectively (p=0.7). The overall rate of adequacy improved from 74% before crossover to 90% after crossover (p<0.01). When comparing the two groups after crossover, the rate of obtaining adequate samples was significantly higher in the 25-G arm than in the 22-G arm (95.8% vs. 86.1%; p=0.03). CONCLUSIONS The 25-G needle was superior to the 22-G needle for endoscopic ultrasound-guided fine-needle aspiration biopsy. The adequacy and diagnostic accuracy improved after crossover, reaching 90%.
Collapse
Affiliation(s)
- Silvia Carrara
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy.
| | - Andrea Anderloni
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Manol Jovani
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Luca Di Tommaso
- Department of Pathology, Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Daoud Rahal
- Department of Pathology, Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Cesare Hassan
- Endoscopy Unit, Nuovo Regina Margherita Hospital, Rome, Italy
| | - Lorenzo Ridola
- Endoscopy Unit, Nuovo Regina Margherita Hospital, Rome, Italy
| | - Davide Federico
- Department of Pathology, Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Alessandra Loriga
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Alessandro Repici
- Digestive Endoscopy Unit, Division of Gastroenterology, Humanitas Research Hospital, Rozzano, Milan, Italy
| |
Collapse
|
34
|
Kongkam P, Pittayanon R, Sampatanukul P, Angsuwatcharakon P, Aniwan S, Prueksapanich P, Sriuranpong V, Navicharern P, Treeprasertsuk S, Kullavanijaya P, Rerknimitr R. Endoscopic ultrasound-guided needle-based confocal laser endomicroscopy for diagnosis of solid pancreatic lesions (ENES): a pilot study. Endosc Int Open 2016; 4:E17-23. [PMID: 26793780 PMCID: PMC4713175 DOI: 10.1055/s-0034-1393183] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2015] [Accepted: 08/17/2015] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND AND STUDY AIMS Endoscopic ultrasound-guided needle-based confocal laser endomicroscopy (EUS-nCLE) has been shown to aid in the diagnosis of cystic pancreatic lesions. This is a pilot project to study its findings in patients with solid pancreatic lesions (SPLs) with a prospective single-blinded study design. METHODS Patients with SPLs undergoing trans-gastric EUS fine needle aspiration (EUS-FNA) from July 2013 to March 2014 were prospectively enrolled. The nCLE diagnoses were compared with the final diagnoses. Researchers learned about the EUS-nCLE findings from previously published studies and applied it to diagnose SPLs. In the meantime, the findings were recorded. RESULTS In total, 22 patients were recruited (mean age 62.7 years, SD 13.8 years; 14 men and eight women). The mean maximal tumor diameter was 36.0 mm (SD 10.9 mm). EUS-nCLE yielded satisfactory images in all patients during the first EUS procedure and diagnosed benign and malignant SPLs in 3 and 19 patients, respectively. Final diagnoses of malignant SPLs were made in 19 patients. Benign SPLs were eventually diagnosed in three patients, with confirmed the cytology and disease stability during the 12-month follow-up period. At the end of the project, based on the results of this current study, EUS-nCLE findings for malignant SPLs were dark clumping with or without dilated vessels (> 40 μm). There were two criteria for diagnosing benign lesions which were white fibrous bands and normal acini cells. The accuracy rate of EUS-nCLE was 90.9 % (20/22). One falsely diagnosed malignant SPL was an inflammatory mass from a recent acute pancreatitis. Another one with a pancreatic neuroendocrine tumor presenting with a symptomatic pseudocyst was incorrectly diagnosed as an inflammatory mass. This was likely from sampling error of the EUS-nCLE probe in an inflammatory area. Only one patient had post EUS-FNA bleeding but did not require a blood transfusion. The inter-observer agreement among three blinded endoscopists was almost perfect (Kappa 0.82). CONCLUSION EUS-nCLE is a promising technique for the diagnosis of SPLs with good inter-observer agreement. Study registration: TCTR20140402001.
Collapse
Affiliation(s)
- Pradermchai Kongkam
- Gastrointestinal Endoscopy Excellent Center, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand,Corresponding author Pradermchai Kongkam, MD Gastrointestinal Endoscopy Excellence CenterDepartment of MedicineFaculty of MedicineChulalongkorn University and King Chulalongkorn Memorial HospitalThai Red Cross Society1873, Rama 4 RoadPatumwanBangkokThailand 10500+66-2-6524219
| | - Rapat Pittayanon
- Gastrointestinal Endoscopy Excellent Center, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Pichet Sampatanukul
- Department of Pathology, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Phonthep Angsuwatcharakon
- Gastrointestinal Endoscopy Excellent Center, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Satimai Aniwan
- Gastrointestinal Endoscopy Excellent Center, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Piyapan Prueksapanich
- Gastrointestinal Endoscopy Excellent Center, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Virote Sriuranpong
- Gastrointestinal Endoscopy Excellent Center, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Patpong Navicharern
- Department of Surgery, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Sombat Treeprasertsuk
- Gastrointestinal Endoscopy Excellent Center, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Pinit Kullavanijaya
- Gastrointestinal Endoscopy Excellent Center, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| | - Rungsun Rerknimitr
- Gastrointestinal Endoscopy Excellent Center, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Bangkok, Thailand
| |
Collapse
|
35
|
Yang MJ, Yim H, Hwang JC, Lee D, Kim YB, Lim SG, Kim SS, Kang JK, Yoo BM, Kim JH. Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles. BMC Gastroenterol 2015; 15:122. [PMID: 26419845 PMCID: PMC4589185 DOI: 10.1186/s12876-015-0352-9] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2014] [Accepted: 09/21/2015] [Indexed: 01/06/2023] Open
Abstract
Background Biopsy needles have recently been developed to obtain both cytological and histological specimens during endoscopic ultrasound (EUS). We conducted this study to compare 22-gauge (G) fine needle aspiration (FNA) needles, which have been the most frequently used, and new 25G fine needle biopsy (FNB) needles for EUS-guided sampling of solid pancreatic masses. Methods We conducted a retrospective cohort study of all EUS-guided sampling performed between June 2010 and October 2013. During the study period, 76 patients with pancreatic masses underwent EUS-guided sampling with a 22G FNA needle (n = 38) or a 25G FNB needle (n = 38) for diagnosis. An on-site cytopathologist was not present during the procedure. Technical success, the number of needle passes, cytological diagnostic accuracy, cytological sample quality (conventional smear and liquid-based preparation), histological diagnostic accuracy, and complications were reviewed and compared. Results There were no significant differences in technical success (100 % for both), the mean number of needle passes (5.05 vs. 5.55, P = 0.132), or complications (0 % for both) between the 22G FNA group and the 25G FNB group. The 22G FNA and 25G FNB groups exhibited comparable outcomes with respect to cytological diagnostic accuracy (97.4 % vs. 89.5 %, P = 0.358) and histological diagnostic accuracy (34.2 % vs. 52.6 %, P = 0.105). In the cytological sample quality analysis, the 25G FNB group exhibited higher scores for the amount of diagnostic cellular material present (22G FNA: 0.92 vs. 25G FNB: 1.32, P = 0.030) and the retention of appropriate architecture (22G FNA: 0.97 vs. 25G FNB: 1.42, P = 0.010) in the liquid-based preparation. The 25G FNB group showed a better histological diagnostic yield for specific tumor discrimination compared with the 22G FNA group (60 % vs. 32.4 %, P = 0.018). Conclusions Use of the 25G FNB needle was technically feasible, safe, efficient, and comparable to use of the standard 22G FNA needle in patients with solid pancreatic masses in the absence of an on-site cytopathologist. The cytological sample quality in the liquid-based preparation and the histological diagnostic yield for specific tumor discrimination of EUS-guided sampling using a 25G FNB needle were significantly higher than those using a 22G FNA needle.
Collapse
Affiliation(s)
- Min Jae Yang
- Department of Gastroenterology, Ajou University School of Medicine, San-5, Woncheon-dong, Yongtong-gu, 443-721, Suwon, Korea.
| | - Hyunee Yim
- Department of Pathology, Ajou University School of Medicine, San-5, Woncheon-dong, Yongtong-gu, 443-721, Suwon, Korea.
| | - Jae Chul Hwang
- Department of Gastroenterology, Ajou University School of Medicine, San-5, Woncheon-dong, Yongtong-gu, 443-721, Suwon, Korea.
| | - Dakeun Lee
- Department of Pathology, Ajou University School of Medicine, San-5, Woncheon-dong, Yongtong-gu, 443-721, Suwon, Korea.
| | - Young Bae Kim
- Department of Pathology, Ajou University School of Medicine, San-5, Woncheon-dong, Yongtong-gu, 443-721, Suwon, Korea.
| | - Sun Gyo Lim
- Department of Gastroenterology, Ajou University School of Medicine, San-5, Woncheon-dong, Yongtong-gu, 443-721, Suwon, Korea.
| | - Soon Sun Kim
- Department of Gastroenterology, Ajou University School of Medicine, San-5, Woncheon-dong, Yongtong-gu, 443-721, Suwon, Korea.
| | - Joon Koo Kang
- Department of Gastroenterology, Ajou University School of Medicine, San-5, Woncheon-dong, Yongtong-gu, 443-721, Suwon, Korea.
| | - Byung Moo Yoo
- Department of Gastroenterology, Ajou University School of Medicine, San-5, Woncheon-dong, Yongtong-gu, 443-721, Suwon, Korea.
| | - Jin Hong Kim
- Department of Gastroenterology, Ajou University School of Medicine, San-5, Woncheon-dong, Yongtong-gu, 443-721, Suwon, Korea.
| |
Collapse
|
36
|
Kin T, Katanuma A, Yane K, Takahashi K, Osanai M, Takaki R, Matsumoto K, Gon K, Matsumori T, Tomonari A, Maguchi H, Shinohara T, Nojima M. Diagnostic ability of EUS-FNA for pancreatic solid lesions with conventional 22-gauge needle using the slow pull technique: a prospective study. Scand J Gastroenterol 2015; 50:900-7. [PMID: 25732902 DOI: 10.3109/00365521.2014.983155] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE Endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) using the slow pull technique (SP-FNA) has recently attracted attention as an effective tissue acquisition technique. However, efficacy of SP-FNA with a 22-gauge conventional needle remains unclear. The aim of this study is to evaluate the diagnostic ability of SP-FNA with a 22-gauge needle. MATERIAL AND METHODS Patients with a pancreatic solid lesion were prospectively enrolled in this study. SP-FNA was performed at two needle passes with a 22-gauge needle. One dedicated pathologist evaluated the obtained samples in terms of quantity (Grade 0: scant; Grade 1: inadequate; Grade 2: adequate), quality (Grade 0: poor; Grade 1: moderate; Grade 2: good), and blood contamination (Grade 0: significant; Grade 1: moderate; Grade 2: low), and provided a pathological diagnosis. Additional EUS-FNA was performed by applying suction (SA-FNA). The evaluation points were as follows: diagnostic accuracy of SP-FNA compared with that of SA-FNA, and the quantity, quality, and blood contamination level of SP-FNA-obtained samples. RESULTS We enrolled 40 cases. The diagnostic accuracy of SP-FNA was 90% (36/40). There was no significant difference in the accuracy between SP-FNA and SA-FNA (90% vs. 90%, p = 1.000). The samples obtained using SP-FNA were assessed as Grade 2 for quantity in 29 cases (73%), quality in 31 (78%), and blood contamination in 25 (63%). CONCLUSIONS Adequate, high-quality, and unsubstantially blood-contaminated samples could be obtained using SP-FNA. The diagnostic ability of SP-FNA was 90%, which appeared to be similar to that of SA-FNA.
Collapse
Affiliation(s)
- Toshifumi Kin
- Center for Gastroenterology, Teine-Keijinkai Hospital , 1-40/1-12 Maeda, Teine-ku, Sapporo, Hokkaido, 006-8555 , Japan
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Majori M, Anghinolfi M, Scarascia A, Nizzoli R, Casalini AG. Conventional transbronchial needle aspiration with 23 gauge needle: a preliminary study. J Thorac Dis 2015; 7:758-63. [PMID: 25973244 DOI: 10.3978/j.issn.2072-1439.2015.04.26] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Accepted: 02/28/2015] [Indexed: 11/14/2022]
Abstract
BACKGROUND Conventional transbronchial needle aspiration (cTBNA) is a safe and minimally invasive procedure with a high yield for the diagnosis of large lymph nodes (LNs) in favourable locations (LNs >1.5 cm in stations #4R and/or #7). However, it is usually underutilized by pulmonologist. One of the main reasons given for not performing cTBNA is the risk of puncturing vascular structures of the mediastinum. Recently, with the twofold objective of minimize the risk of bleeding and reduce the cTBNA cost, a thinner and less expensive needle has been commercialized. It is a 23 gauge (G) needle that costs 34, 37 €. The aim of our study was to analyze the sample adequacy, diagnostic accuracy and safety of this needle in comparison with 21 and 22 G needles (average cost: 6,400 €). METHODS We retrospectively analysed medical records from patients who underwent bronchoscopy with cTBNA for the diagnosis of LNs >1.5 cm in stations #4R and/or #7 at the Thoracic Endoscopy Unit of the University Hospital of Parma from January 1st, 2007 to October 31(st), 2011. Five hundred patients underwent cTBNA from January 1(st), 2007 to October 31(st), 2011. In order to reduce the technical and personal bias for sampling procedure we analyzed only cases sampled by a single well-trained bronchoscopist, particularly skilful at cTBNA. RESULTS A total of 222 patients (186 men; mean age 63 years±12, range 6-89) with LNs >1.5 cm in stations #4R and/or #7 were identified. A 23 G needle was used in 84 patients (38%), a 21 G needle in 88 patients (40%) and a 22 G needle in 50 patients (22%). No statistically significant differences between the 23 G group and the 21 or 22 G group in sample adequacy (P=0.78 and P=0.12, respectively) and diagnostic accuracy (P=0.9 and P=0.4, respectively) were found. There were no intraprocedural or postprocedural complications irrespective of the size of needle used. CONCLUSIONS Transbronchial 23 G needle is as safe and effective as the 21 and 22 G needle for the sampling of LNs >1.5 cm in stations #4R and/or #7. For this reason, to obtain cytology specimens from large LNs in favourable locations, the 23 G needle may represent an alternative and less expensive choice compared to 21 and 22 G needles, even if our observation needs to be confirmed in a larger prospective study.
Collapse
Affiliation(s)
- Maria Majori
- 1 Pulmonology Unit and Thoracic Endoscopy, 2 Respiratory Disease Unit, 3 Medical Oncology Unit, University Hospital of Parma, Parma, Italy
| | - Miriam Anghinolfi
- 1 Pulmonology Unit and Thoracic Endoscopy, 2 Respiratory Disease Unit, 3 Medical Oncology Unit, University Hospital of Parma, Parma, Italy
| | - Alessandro Scarascia
- 1 Pulmonology Unit and Thoracic Endoscopy, 2 Respiratory Disease Unit, 3 Medical Oncology Unit, University Hospital of Parma, Parma, Italy
| | - Rita Nizzoli
- 1 Pulmonology Unit and Thoracic Endoscopy, 2 Respiratory Disease Unit, 3 Medical Oncology Unit, University Hospital of Parma, Parma, Italy
| | - Angelo Gianni Casalini
- 1 Pulmonology Unit and Thoracic Endoscopy, 2 Respiratory Disease Unit, 3 Medical Oncology Unit, University Hospital of Parma, Parma, Italy
| |
Collapse
|
38
|
Huang JYL, Chang KJ. Improvements and innovations in endoscopic ultrasound guided fine needle aspiration. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2015; 22:E37-46. [PMID: 25762125 DOI: 10.1002/jhbp.232] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2014] [Accepted: 01/29/2015] [Indexed: 12/11/2022]
Affiliation(s)
- Jason Yan-Lin Huang
- H.H. Chao Comprehensive Digestive Disease Center, University of California, Irvine Medical Center, 101 The City Dr. Blvd, Orange, CA, 92686, USA.
| | - Kenneth J Chang
- H.H. Chao Comprehensive Digestive Disease Center, University of California, Irvine Medical Center, 101 The City Dr. Blvd, Orange, CA, 92686, USA
| |
Collapse
|
39
|
Katanuma A, Itoi T, Baron TH, Yasuda I, Kin T, Yane K, Maguchi H, Yamazaki H, Sano I, Minami R, Manabu SY, Ikarashi S, Osanai M, Takahashi K. Bench-top testing of suction forces generated through endoscopic ultrasound-guided aspiration needles. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2015; 22:379-85. [PMID: 25557010 DOI: 10.1002/jhbp.201] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
BACKGROUND Adequate needle size and tissue acquisition techniques for endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) need further elucidation. Moreover, the actual negative pressure and suction forces of FNA needles remain unknown. We evaluated the suction forces of 19-gauge, 22-gauge, and 25-gauge conventional FNA needles and side hole aspiration needles using conventional negative pressure and the slow pull technique. METHODS Using a manometer, we determined the mean (SD) negative pressure and suction force for needle gauge, aspiration volume, and aspiration technique. We also evaluated the time to reach the maximum negative pressure. RESULTS Suction force was comparatively higher in the 19-gauge needle when 50 ml of negative pressure was applied. Suction force using the slow pull method was very weak at 5% of pressure found with conventional methods. With the use of a 20-ml syringe, the time to reach the maximum negative pressure was 4 s in the 19-gauge needle, 11 s in the 22-gauge needle, and 80 s in the 25-gauge needle. CONCLUSIONS Bench-top testing showed that suction force increases with a larger gauge needle and larger aspiration volume. The slow pull method produces a very weak suction force. The time to reach the maximum negative pressure was longest in the 25-gauge needle.
Collapse
Affiliation(s)
- Akio Katanuma
- Center for Gastroenterology, Teine-Keijinkai Hospital, 1-40-1-12 Maeda, Teine-ku, Sapporo, 006-8555, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Kudo T, Kawakami H, Hayashi T, Yasuda I, Mukai T, Inoue H, Katanuma A, Kawakubo K, Ishiwatari H, Doi S, Yamada R, Maguchi H, Isayama H, Mitsuhashi T, Sakamoto N. High and low negative pressure suction techniques in EUS-guided fine-needle tissue acquisition by using 25-gauge needles: a multicenter, prospective, randomized, controlled trial. Gastrointest Endosc 2014; 80:1030-7.e1. [PMID: 24890422 DOI: 10.1016/j.gie.2014.04.012] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2013] [Accepted: 04/03/2014] [Indexed: 12/15/2022]
Abstract
BACKGROUND EUS-guided FNA (EUS-FNA) has a high diagnostic accuracy for pancreatic diseases. However, although most reports have typically focused on cytology, histological tissue quality has rarely been investigated. The effectiveness of EUS-FNA combined with high negative pressure (HNP) suction was recently indicated for tissue acquisition, but has not thus far been tested in a prospective, randomized clinical trial. OBJECTIVE To evaluate the adequacy of EUS-FNA with HNP for the histological diagnosis of pancreatic lesions by using 25-gauge needles. DESIGN Prospective, single-blind, randomized, controlled crossover trial. SETTING Seven tertiary referral centers. PATIENTS Patients referred for EUS-FNA of pancreatic solid lesions. From July 2011 to April 2012, 90 patients underwent EUS-FNA of pancreatic solid masses by using normal negative pressure (NNP) and HNP with 2 respective passes. The order of the passes was randomized, and the sample adequacy, quality, and histology were evaluated by a single expert pathologist. INTERVENTION EUS-FNA by using NNP and HNP. MAIN OUTCOME MEASUREMENTS The adequacy of tissue acquisition and the accuracy of histological diagnoses made by using the EUS-FNA technique with HNP. RESULTS We found that 72.2% (65/90) and 90% (81/90) of the specimens obtained using NNP and HNP, respectively, were adequate for histological diagnosis (P = .0003, McNemar test). For 73.3% (66/90) and 82.2% (74/90) of the specimens obtained by using NNP and HNP, respectively, an accurate diagnosis was achieved (P = .06, McNemar test). Pancreatitis developed in 1 patient after this procedure, which subsided with conservative therapy. LIMITATIONS This was a single-blinded, crossover study. CONCLUSION Biopsy procedures that combine the EUS-FNA with HNP techniques are superior to EUS-FNA with NNP procedures for tissue acquisition. ( CLINICAL TRIAL REGISTRATION NUMBER UMIN000005939.).
Collapse
Affiliation(s)
- Taiki Kudo
- Department of Gastroenterology and Hepatology, Hokkaido University Graduate School of Medicine, Sapporo, Japan
| | - Hiroshi Kawakami
- Department of Gastroenterology and Hepatology, Hokkaido University Graduate School of Medicine, Sapporo, Japan
| | - Tsuyoshi Hayashi
- Department of Medical Oncology and Hematology, Sapporo Medical University, Sapporo, Japan
| | - Ichiro Yasuda
- The First Department of Internal Medicine, Gifu University Hospital, Gifu, Japan
| | - Tsuyoshi Mukai
- Department of Gastroenterology, Gifu Municipal Hospital, Gifu, Japan
| | - Hiroyuki Inoue
- Department of Gastroenterology and Hepatology, Mie University, Mie, Japan
| | - Akio Katanuma
- Center for Gastroenterology, Teine-Keijinkai Hospital, Sapporo, Japan
| | - Kazumichi Kawakubo
- Department of Gastroenterology and Hepatology, Hokkaido University Graduate School of Medicine, Sapporo, Japan; Department of Gastroenterology, The University of Tokyo, Tokyo, Japan
| | - Hirotoshi Ishiwatari
- Department of Medical Oncology and Hematology, Sapporo Medical University, Sapporo, Japan
| | - Shinpei Doi
- The First Department of Internal Medicine, Gifu University Hospital, Gifu, Japan
| | - Reiko Yamada
- Department of Gastroenterology and Hepatology, Mie University, Mie, Japan
| | - Hiroyuki Maguchi
- Center for Gastroenterology, Teine-Keijinkai Hospital, Sapporo, Japan
| | - Hiroyuki Isayama
- Department of Gastroenterology, The University of Tokyo, Tokyo, Japan
| | - Tomoko Mitsuhashi
- Department of Surgical Pathology, Hokkaido University Hospital, Sapporo, Japan
| | - Naoya Sakamoto
- Department of Gastroenterology and Hepatology, Hokkaido University Graduate School of Medicine, Sapporo, Japan
| |
Collapse
|
41
|
EUS-guided tissue acquisition: an evidence-based approach (with videos). Gastrointest Endosc 2014; 80:939-59.e7. [PMID: 25434654 DOI: 10.1016/j.gie.2014.07.066] [Citation(s) in RCA: 93] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2014] [Accepted: 07/17/2014] [Indexed: 02/08/2023]
|
42
|
Harada R, Kato H, Fushimi S, Iwamuro M, Inoue H, Muro S, Sakakihara I, Noma Y, Yamamoto N, Horiguchi S, Tsutsumi K, Okada H, Yamamoto K. An expanded training program for endosonographers improved self-diagnosed accuracy of endoscopic ultrasound-guided fine-needle aspiration cytology of the pancreas. Scand J Gastroenterol 2014; 49:1119-23. [PMID: 24896656 DOI: 10.3109/00365521.2014.915051] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE Rapid on-site evaluation (ROSE) of cytologic adequacy improves the diagnostic yield of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). However, on-site advice from a cytotechnologist or cytopathologist is not always available during EUS-FNA. To enhance endosonographers' ability to assess the adequacy of EUS-FNA specimens, we designed an intensive, 2-h interactive training program. The aim of this study was to determine the usefulness of the program. METHODS Four cytological pictures were selected by a trained cytotechnologist and board-certified cytopathologist from each of the seven patients who underwent EUS-FNA for pancreatic mass in Okayama University Hospital. In total, 28 pictures were used in this study. Twenty endosonographers and 14 cytologists with different levels of EUS-FNA experience evaluated cytological pictures independently before and after the training program. RESULTS Endosonographers' skill in evaluating the adequacy of EUS-FNA specimens was significantly improved after the completion of the training program (p < 0.001). In contrast, almost all cytologists correctly judged the adequacy of the specimens before taking the training program. CONCLUSIONS This intensive, 2-h interactive training program is useful for endosonographers and capable of improving ROSE of EUS-FNA specimens.
Collapse
Affiliation(s)
- Ryo Harada
- Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences , Okayama , Japan
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Nakai Y, Isayama H, Chang KJ, Yamamoto N, Hamada T, Uchino R, Mizuno S, Miyabayashi K, Yamamoto K, Kawakubo K, Kogure H, Sasaki T, Hirano K, Tanaka M, Tada M, Fukayama M, Koike K. Slow pull versus suction in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid masses. Dig Dis Sci 2014; 59:1578-85. [PMID: 24429514 DOI: 10.1007/s10620-013-3019-9] [Citation(s) in RCA: 130] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2013] [Accepted: 12/29/2013] [Indexed: 12/16/2022]
Abstract
BACKGROUND Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) of pancreatic masses is an established procedure for obtaining a pathological specimen. However, application of suction during EUS-FNA is still controversial and the efficacy of the slow-pull technique was recently reported for new core biopsy needles. AIM The purpose of this study was to compare the suction and slow-pull techniques using regular FNA needles. METHODS The diagnostic yield of the suction and slow-pull techniques was retrospectively studied for patients who underwent EUS-FNA for pancreatic solid lesions. RESULTS A total of 367 passes (181 by suction and 186 by the slow-pull technique) were performed during 97 EUS-FNA procedures for 93 patients with pancreatic solid lesions. The slow-pull technique resulted in lower scores for cellularity (≥2 for 37.5 % vs. 76.7 %) but scores for contamination with blood were lower (≥2 for 25.0 % vs. 66.7 %) and sensitivity of diagnosis of malignancy was higher (90.0 % vs. 67.9 %) when a 25-gauge FNA needle was used. There were no significant differences between the two techniques when a 22-gauge needle was used. In multivariate analysis of 82 cases with malignancy, the slow-pull technique (odds ratio (OR) 1.92, P = 0.028), tumor size ≥25 mm (OR 4.64, P < 0.001), and tumor location in the body or tail (OR 2.82, P < 0.001) were associated with greater sensitivity. CONCLUSION The slow-pull technique was associated with less contamination with blood and can potentially increase the diagnostic yield compared with the suction technique in EUS-FNA of pancreatic solid masses, especially with a 25-gauge FNA needle.
Collapse
Affiliation(s)
- Yousuke Nakai
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Buscarini E, Pezzilli R, Cannizzaro R, De Angelis C, Gion M, Morana G, Zamboni G, Arcidiacono P, Balzano G, Barresi L, Basso D, Bocus P, Calculli L, Capurso G, Canzonieri V, Casadei R, Crippa S, D'Onofrio M, Frulloni L, Fusaroli P, Manfredi G, Pacchioni D, Pasquali C, Rocca R, Ventrucci M, Venturini S, Villanacci V, Zerbi A, Falconi M. Italian consensus guidelines for the diagnostic work-up and follow-up of cystic pancreatic neoplasms. Dig Liver Dis 2014; 46:479-93. [PMID: 24809235 DOI: 10.1016/j.dld.2013.12.019] [Citation(s) in RCA: 83] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2013] [Revised: 12/07/2013] [Accepted: 12/30/2013] [Indexed: 12/11/2022]
Abstract
This report contains clinically oriented guidelines for the diagnostic work-up and follow-up of cystic pancreatic neoplasms in patients fit for treatment. The statements were elaborated by working groups of experts by searching and analysing the literature, and then underwent a consensus process using a modified Delphi procedure. The statements report recommendations regarding the most appropriate use and timing of various imaging techniques and of endoscopic ultrasound, the role of circulating and intracystic markers and the pathologic evaluation for the diagnosis and follow-up of cystic pancreatic neoplasms.
Collapse
Affiliation(s)
| | | | | | - Raffaele Pezzilli
- Pancreas Unit, Department of Digestive Diseases and Internal Medicine, S. Orsola-Malpighi Hospital, Bologna, Italy
| | | | - Claudio De Angelis
- Gastroenterology and Hepatology Department, A.O. San Giovanni Battista/Molinette, University of Turin, Turin, Italy
| | - Massimo Gion
- Department of Clinical Pathology, AULSS 12, Venice, Italy
| | - Giovanni Morana
- Department of Diagnostic Radiology, Ospedale Cà Foncello, Treviso, Italy
| | | | - Paolo Arcidiacono
- Division of Gastroenterology and Gastrointestinal Endoscopy, Vita-Salute, Italy
| | - Gianpaolo Balzano
- Department of Surgery, San Raffaele Scientific Institute, Milan, Italy
| | - Luca Barresi
- Gastroenterology and Endoscopy Unit, ISMETT, Palermo, Italy
| | - Daniela Basso
- Department of Laboratory Medicine, University Hospital, Padua, Italy
| | - Paolo Bocus
- Gastroenterology Unit, Ospedale Sacro Cuore-Don Calabria, Negrar, Verona, Italy
| | - Lucia Calculli
- Department of Radiology, S. Orsola-Malpighi Hospital, Bologna, Italy
| | - Gabriele Capurso
- Digestive and Liver Disease Unit, Faculty of Medicine and Psychology, Sapienza University of Rome at S. Andrea Hospital, Rome, Italy
| | | | - Riccardo Casadei
- Department of Surgery, University of Bologna, S. Orsola-Malpighi Hospital, Bologna, Italy
| | - Stefano Crippa
- Department of Surgery, Pancreas Unit, Università Politecnica delle Marche, Ancona, Italy
| | - Mirko D'Onofrio
- Department of Radiology, University Hospital G.B. Rossi, University of Verona, Verona, Italy
| | - Luca Frulloni
- Department of Surgical and Gastroenterological Sciences, University of Verona, Verona, Italy
| | - Pietro Fusaroli
- Department of Clinical Medicine, University of Bologna, Bologna, Italy
| | | | | | - Claudio Pasquali
- Surgery Unit IV, Department of Medical and Surgical Sciences, University of Padua, Padua, Italy
| | - Rodolfo Rocca
- Gastroenterology Unit, Mauriziano Hospital, Turin, Italy
| | - Maurizio Ventrucci
- Department of Internal Medicine and Gastroenterology, Bentivoglio Hospital, Bologna, Italy
| | - Silvia Venturini
- Department of Diagnostic Radiology, Ospedale Cà Foncello, Treviso, Italy
| | | | - Alessandro Zerbi
- Pancreatic Surgery, Department of Surgery, Humanitas Clinical and Research Center, Milan, Italy
| | - Massimo Falconi
- Department of Surgery, Pancreas Unit, Università Politecnica delle Marche, Ancona, Italy
| | | |
Collapse
|
45
|
Tarantino I, Di Mitri R, Fabbri C, Pagano N, Barresi L, Granata A, Liotta R, Mocciaro F, Maimone A, Baccarini P, Fabio T, Curcio G, Repici A, Traina M. Is diagnostic accuracy of fine needle aspiration on solid pancreatic lesions aspiration-related? A multicentre randomised trial. Dig Liver Dis 2014; 46:523-6. [PMID: 24704290 DOI: 10.1016/j.dld.2014.02.023] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2014] [Revised: 02/19/2014] [Accepted: 02/25/2014] [Indexed: 12/11/2022]
Abstract
BACKGROUND Endoscopic ultrasound fine needle aspiration has a central role in the diagnostic algorithm of solid pancreatic masses. Data comparing the fine needle aspiration performed with different aspiration volume and without aspiration are lacking. We compared endoscopic ultrasound fine needle aspiration performed with the 22 gauge needle with different aspiration volumes (10, 20 and 0 ml), for adequacy, diagnostic accuracy and complications. METHODS Prospective clinical study at four referral centres. Endoscopic ultrasound fine needle aspiration was performed with a 22G needle with both volume aspiration (10 and 20 cc) and without syringe, in randomly assigned sequence. The cyto-pathologist was blinded as to which aspiration was used for each specimen. RESULTS 100 patients met the inclusion criteria, 88 completed the study. The masses had a mean size of 32.21±11.24 mm. Sample adequacy evaluated on site was 87.5% with 20 ml aspiration vs. 76.1% with 10 ml (p=0.051), and 45.4% without aspiration (20 ml vs. 0 ml p<0.001; 10 ml vs. 0 ml p<0.001). The diagnostic accuracy was significantly better with 20 ml than with 10 ml and 0 ml (86.2% vs. 69.0% vs. 49.4% p<0.001). CONCLUSIONS A significantly higher adequacy and accuracy were observed with the 20 ml aspiration puncture, therefore performing all passes with this volume aspiration may improve the diagnostic power of fine needle aspiration.
Collapse
Affiliation(s)
- Ilaria Tarantino
- Gastroenterology Department, ISMETT/UPMC (Mediterranean Institute for Transplantation and Advanced Specialized Therapies/University of Pittsburgh Medical Center in Italy), Palermo, Italy.
| | - Roberto Di Mitri
- Gastroenterology Department, Civico-A.R.N.A.S. Hospital, Palermo, Italy
| | - Carlo Fabbri
- Gastroenterology Department, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy
| | - Nico Pagano
- Gastroenterology Department, Humanitas Irccs, Rozzano, Milano, Italy
| | - Luca Barresi
- Gastroenterology Department, ISMETT/UPMC (Mediterranean Institute for Transplantation and Advanced Specialized Therapies/University of Pittsburgh Medical Center in Italy), Palermo, Italy
| | - Antonino Granata
- Gastroenterology Department, ISMETT/UPMC (Mediterranean Institute for Transplantation and Advanced Specialized Therapies/University of Pittsburgh Medical Center in Italy), Palermo, Italy
| | - Rosa Liotta
- Pathology Unit, ISMETT/UPMC (Mediterranean Institute for Transplantation and Advanced Specialized Therapies/University of Pittsburgh Medical Center in Italy), Italy
| | - Filippo Mocciaro
- Gastroenterology Department, Civico-A.R.N.A.S. Hospital, Palermo, Italy
| | | | - Paola Baccarini
- Pathology Unit, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy
| | - Tuzzolino Fabio
- Office of Research, ISMETT/UPMC (Mediterranean Institute for Transplantation and Advanced Specialized Therapies/University of Pittsburgh Medical Center in Italy), Italy
| | - Gabriele Curcio
- Gastroenterology Department, ISMETT/UPMC (Mediterranean Institute for Transplantation and Advanced Specialized Therapies/University of Pittsburgh Medical Center in Italy), Palermo, Italy
| | - Alessandro Repici
- Gastroenterology Department, Humanitas Irccs, Rozzano, Milano, Italy
| | - Mario Traina
- Gastroenterology Department, ISMETT/UPMC (Mediterranean Institute for Transplantation and Advanced Specialized Therapies/University of Pittsburgh Medical Center in Italy), Palermo, Italy
| |
Collapse
|
46
|
Gimeno‐García AZ, Elwassief A, Paquin SC, Gariépy G, Sahai AV. Randomized controlled trial comparing stylet-free endoscopic ultrasound-guided fine-needle aspiration with 22-G and 25-G needles. Dig Endosc 2014; 26:467-73. [PMID: 24877242 DOI: 10.1111/den.12204] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
BACKGROUND AND AIM Previous studies comparing endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) results with different gauge needles have all been carried out with the stylet in place and show no clear advantage to the larger 22-G needle. Similar data for stylet-free EUS-FNA (SF-EUS-FNA) are unavailable. The aim of the present study was to determine whether diagnostic yield and specimen adequacy is superior with the 22-G needle as compared to the 25-G needle. METHODS All patients ≥ 18 years referred for solid-lesion EUS-FNA were eligible. Patients with suspected diagnosis of lymphoma, gastrointestinal stromal tumor, sarcoidosis, significant coagulopathy (international normalized ratio > 1.5 or platelets < 50000/mm(3)), use of clopidogrel within 7 days of EUS, and pregnancy were excluded. The two needles were compared regarding diagnostic yield, sample adequacy, bloodiness, ease of puncture, visibility, number of passes, failures, and complications. RESULTS One hundred and twenty consecutive patients were included and 126 lesions were sampled. Sensitivity, specificity, positive predictive value and negative predictive value for the 22-G SF-EUS-FNA were 83%, 100%, 100% and 56%, respectively, and for the 25-G SF-EUS-FNA were 88.8%, 100%, 100% and 76.5%, respectively (P=NS). There were no significant differences between the 22-G and the 25-G FNA needles in sample adequacy, bloodiness, ease of puncture, FNA failure, visibility, number of passes and complications; and no significant differences between either needle were found in relation to lesion site. CONCLUSION For SF-EUS-FNA, the larger 22-G needle offers no advantage over the smaller 25-G needle.
Collapse
Affiliation(s)
| | - Ahmed Elwassief
- Internal Medicine Department, Gastroenterology UnitAlhossien Hospital, Alazhar University Cairo Egypt
| | - Sarto C. Paquin
- Department of GastroenterologyCentre Hospitalier de l'Université de Montréal Montreal Canada
| | - Gilles Gariépy
- Department of PathologyCentre Hospitalier de l'Université de Montréal Montreal Canada
| | - Anand V. Sahai
- Department of GastroenterologyCentre Hospitalier de l'Université de Montréal Montreal Canada
| |
Collapse
|
47
|
Matynia AP, Schmidt RL, Barraza G, Layfield LJ, Siddiqui AA, Adler DG. Impact of rapid on-site evaluation on the adequacy of endoscopic-ultrasound guided fine-needle aspiration of solid pancreatic lesions: a systematic review and meta-analysis. J Gastroenterol Hepatol 2014; 29:697-705. [PMID: 24783248 DOI: 10.1111/jgh.12431] [Citation(s) in RCA: 96] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Rapid on-site evaluation (ROSE) has the potential to improve adequacy rates for endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic lesions, but its impact is context-dependent. No studies exist that summarize the relationship between ROSE, number of needle passes, and resulting adequacy rates. AIMS To analyze data from previous studies to establish if ROSE is associated with improved adequacy rates; to evaluate the relationship between ROSE, number of needle passes, and the resulting adequacy rates of EUS-FNA for solid pancreatic lesions. METHODS Systematic review and meta-analysis of studies reporting the adequacy rates for EUS-FNA of solid pancreatic lesions. RESULTS The search produced 3822 original studies, of which 70 studies met our inclusion criteria. The overall average adequacy rate was 96.2% (95% confidence interval: 95.5, 96.9). ROSE was associated with a statistically significant improvement of up to 3.5% in adequacy rates. There was heterogeneity in adequacy rates across all subgroups. No association between the assessor type and adequacy rates was found. Studies with ROSE have high per-case adequacy and a relatively high number of needle passes in contrast to non-ROSE studies. ROSE is an effect modifier of the relationship between number of needle passes and adequacy. CONCLUSIONS ROSE is associated with up to 3.5% improvement in adequacy rates for EUS-FNA of solid pancreatic lesions. ROSE assessor type has no impact on adequacy rates. ROSE is an effect modifier on the relationship between needle passes and per-case adequacy for EUS-FNA of solid pancreatic lesions.
Collapse
|
48
|
Layfield LJ, Schmidt RL, Hirschowitz SL, Olson MT, Ali SZ, Dodd LL. Significance of the diagnostic categories "atypical" and "suspicious for malignancy" in the cytologic diagnosis of solid pancreatic masses. Diagn Cytopathol 2014; 42:292-6. [PMID: 24578254 DOI: 10.1002/dc.23078] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2013] [Accepted: 12/03/2013] [Indexed: 12/12/2022]
Abstract
Endoscopic ultrasound guided (EUS) fine-needle aspiration (FNA) investigation of solid pancreatic lesions has been shown to have good sensitivity and specificity. Many lesions can be definitely classified as benign or malignant but some can only be cytologically classified as "atypical" or "suspicious for malignancy". Risk for malignancy in these indeterminate categories has not been well categorized. The cytology records of four University Medical centers were searched for all EUS guided FNAs of solid pancreatic lesions. All cases with a diagnosis of "atypical", or "suspicious for malignancy" were selected for analysis when histologic biopsy or over 18 months clinical follow-up was available. Two hundred and ninety-two cases with a diagnosis of "atypical" or "suspicious for malignancy" and adequate follow-up were obtained from the combined data of the four institutions. The percentage malignant for the categories "atypical" and "suspicious for malignancy" were 79.2 and 96.3%, respectively. If the category "atypical" was classified as benign and "suspicious for malignancy" was classified as malignant, the resulting positive predictive value was 96.3 (95% CI: 92.6-98.5) and the negative predictive value 20.8 (95% CI: 13.4-30.0). The categories of "atypical" and "suspicious for malignancy" stratify risk for malignancy in a fashion, which may aid in patient counseling and selection of follow-up protocols. Classification of "suspicious for malignancy" as malignant optimizes diagnostic sensitivity and specificity.
Collapse
Affiliation(s)
- Lester J Layfield
- Department of Pathology and Anatomical Sciences, University of Missouri, Columbia, Missouri
| | | | | | | | | | | |
Collapse
|
49
|
Vilmann P, Seicean A, Săftoiu A. Tips to overcome technical challenges in EUS-guided tissue acquisition. Gastrointest Endosc Clin N Am 2014; 24:109-24. [PMID: 24215763 DOI: 10.1016/j.giec.2013.08.009] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The diagnostic yield of EUS-FNA depends on several factors, such as the experience of the endosonographer, the characteristics of the lesion, the clinical status of the patient, the size and type of needles, the methods of specimen preparation, as well as cytopathologist expertise. The endosonographic technique can be improved when several tips and tricks useful to overcome challenges of FNA are known. Technical challenges of FNA are related to the characteristics of the lesion and its surroundings, sonographic imaging, and limitations related to the needle. Several tips and tricks necessary to overcome them are presented in this review.
Collapse
Affiliation(s)
- Peter Vilmann
- Department of Endoscopy, Gastrointestinal Unit, Copenhagen University Hospital, Herlev Ringvej 75, Herlev 2730, Denmark
| | | | | |
Collapse
|
50
|
Yasuda I, Iwashita T, Doi S. Tips for endoscopic ultrasound-guided fine needle aspiration of various pancreatic lesions. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2013; 21:E29-33. [PMID: 24353093 DOI: 10.1002/jhbp.60] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is a well-established procedure for diagnosis of pancreatic solid masses. This technique is highly accurate and safe and can be performed uneventfully in most cases. However, factors such as unstable scope position, inappropriate location of the lesion, lesion mobility, and lesion characteristics may complicate the procedure. To overcome such difficulties, it is necessary to select the most suitable needle and consider several technical points according to each situation. We introduce our standard technique for EUS-FNA and provide several tips for ensuring a successful procedure.
Collapse
Affiliation(s)
- Ichiro Yasuda
- First Department of Internal Medicine, Gifu University Hospital, 1-1 Yanagido, Gifu, 501-1194, Japan.
| | | | | |
Collapse
|