Copyright
©The Author(s) 2016.
World J Gastroenterol. Mar 21, 2016; 22(11): 3220-3226
Published online Mar 21, 2016. doi: 10.3748/wjg.v22.i11.3220
Published online Mar 21, 2016. doi: 10.3748/wjg.v22.i11.3220
Table 1 Characteristics of colon polyps visualized in the exam
n (%) | ||
Size | < 5 mm | 19 (47.5) |
5 ≥ and < 10 mm | 12 (30.0) | |
≥ 10 mm | 9 (22.5) | |
Type | Sessile | 23 (57.5) |
Semi pedunculated | 8 (20.0) | |
Pedunculated | 5 (12.5) | |
LST | 4 (10.0) | |
Location | Rectum | 3 (7.5) |
Sigmoid colon | 8 (20.0) | |
Descending colon | 7 (17.5) | |
Transverse colon | 9 (22.5) | |
Ascending colon | 11 (27.5) | |
Cecum | 2 (5.0) | |
Histology | TA with LGD | 27 (67.5) |
TA with HGD | 3 (7.5) | |
Chronic colitis | 6 (15.0) | |
Serrated polyp | 3 (7.5) | |
Inflammatory polyp | 1 (2.5) |
Table 2 Diagnostic accuracy and error range of the estimation of colon polyp size
Visual estimation | Forceps estimation | P value | |
Diagnostic accuracy | |||
Beginners | 0.613 | 0.734 | < 0.001 |
Experts | 0.680 | 0.784 | < 0.001 |
Total | 0.639 | 0.754 | < 0.001 |
Error range (mm) | |||
Beginners | 1.68 ± 1.30 | 1.38 ± 1.08 | < 0.001 |
Experts | 1.42 ± 1.11 | 1.12 ± 1.11 | < 0.001 |
Total | 1.48 ± 1.18 | 1.20 ± 1.10 | < 0.001 |
Table 3 Diagnostic accuracy and error range of the estimation of colon polyp size according to the actual polyp size
Visual estimation | Forceps estimation | P value | |
Diagnostic accuracy | |||
≤ 5 mm | 0.834 | 0.929 | < 0.001 |
6-9 mm | 0.508 | 0.692 | < 0.001 |
≥ 10 mm | 0.403 | 0.469 | 0.018 |
Error range (mm) | |||
≤ 5 mm | 0.90 ± 0.27 | 0.70 ± 0.17 | < 0.001 |
6-9 mm | 1.85 ± 0.82 | 1.30 ± 0.59 | < 0.001 |
≥ 10 mm | 2.71 ± 0.76 | 2.40 ± 0.67 | < 0.001 |
Table 4 Diagnostic accuracy of the estimation of colon polyp size according to the polyp type
Visual estimation | Forceps estimation | P value | |
Sessile type | 0.709 | 0.818 | < 0.001 |
Semi pedunculated type | 0.627 | 0.703 | 0.344 |
Pedunculated type | 0.608 | 0.638 | 0.432 |
LST type | 0.556 | 0.757 | 0.012 |
- Citation: Kim JH, Park SJ, Lee JH, Kim TO, Kim HJ, Kim HW, Lee SH, Baek DH, (BIGS) BUGISGS. Is forceps more useful than visualization for measurement of colon polyp size? World J Gastroenterol 2016; 22(11): 3220-3226
- URL: https://www.wjgnet.com/1007-9327/full/v22/i11/3220.htm
- DOI: https://dx.doi.org/10.3748/wjg.v22.i11.3220