Feng Q, Yan YQ, Zhu J, Tong JL, Xu JR. Optimal b value of diffusion-weighted imaging on a 3.0T magnetic resonance scanner in Crohn’s disease. World J Gastroenterol 2014; 20(35): 12621-12627 [PMID: 25253967 DOI: 10.3748/wjg.v20.i35.12621]
Corresponding Author of This Article
Jian-Rong Xu, Director, Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, No. 1630, Dongfang Road, Pudong New District, Shanghai 200127, China. renjixujianrong@126.com
Research Domain of This Article
Gastroenterology & Hepatology
Article-Type of This Article
Prospective Study
Open-Access Policy of This Article
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Table 2 Mean contrast-to-noise ratios of four b value diffusion-weighted imaging sequences
b = 800
b = 1500
b = 2000
b = 2500
b = 800
79.30 ± 34.59
P = 0.006
P < 0.01
P < 0.01
b = 1500
P = 0.006
57.66 ± 23.95
P = 0.007
P = 0.003
b = 2000
P < 0.01
P = 0.007
36.52 ± 14.95
P = 0.820
b = 2500
P < 0.01
P = 0.003
P = 0.820
34.78 ± 24.83
Table 3 Mean signal-to-noise ratios of four b value diffusion-weighted imaging sequences
b = 800
b = 1500
b = 2000
b = 2500
b = 800
113.98 ± 48.92
P = 0.007
P < 0.01
P < 0.01
b = 1500
P = 0.007
84.77 ± 33.24
P = 0.004
P = 0.001
b = 2000
P < 0.01
P = 0.004
53.58 ± 23.45
P = 0.567
b = 2500
P < 0.01
P = 0.001
P = 0.567
47.58 ± 29.67
Table 4 Apparent diffusion coefficient values of four b value diffusion-weighted imaging sequences
b value (s/mm2)
ADC value (×10-3mm2/s)
P value
Inflammatory segments
Normal segments
800
1.38 ± 0.28
2.00 ± 0.38
< 0.01
1500
1.09 ± 0.20
1.50 ± 0.28
< 0.01
2000
0.95 ± 0.19
1.34 ± 0.28
< 0.01
2500
0.88 ± 0.14
1.20 ± 0.21
< 0.01
Table 5 Overall diagnostic assessment of active Crohn's lesions on diffusion-weighted imaging
b value (s/mm2)
TP
FP
FN
TN
Sensitivity
Specificity
Lesion detection rate
800
71
20
12
145
83.53%
88.96%
87.10%
1500
69
8
16
155
81.18%
95.10%
90.32%
2000
62
9
23
154
72.94%
94.48%
87.10%
2500
55
8
30
155
64.71%
95.10%
84.68%
Citation: Feng Q, Yan YQ, Zhu J, Tong JL, Xu JR. Optimal b value of diffusion-weighted imaging on a 3.0T magnetic resonance scanner in Crohn’s disease. World J Gastroenterol 2014; 20(35): 12621-12627