Meta-Analysis Open Access
Copyright ©The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved.
World J Gastroenterol. Oct 28, 2015; 21(40): 11481-11488
Published online Oct 28, 2015. doi: 10.3748/wjg.v21.i40.11481
Diagnostic accuracy of fluorine-18-fluorodeoxyglucose positron emission tomography in gallbladder cancer: A meta-analysis
Salvatore Annunziata, Daniele Antonio Pizzuto, Carmelo Caldarella, Institute of Nuclear Medicine, Department of Bioimaging and Radiological Sciences, Catholic University of the Sacred Heart, 00168 Rome, Italy
Federica Galiandro, Postgraduate School of General Surgery, Catholic University of the Sacred Heart, 00168 Rome, Italy
Ramin Sadeghi, Nuclear Medicine Research Center, Mashhad University of Medical Sciences, 91735315 Mashhad, Iran
Giorgio Treglia, Department of Nuclear Medicine and PET Center, Oncology Institute of Southern Switzerland, 6500 Bellinzona, Switzerland
Author contributions: Annunziata S, Galiandro F and Treglia G designed research; Annunziata S and Pizzuto DA performed research; Caldarella C and Sadeghi R analyzed data; Annunziata S, Pizzuto DA and Treglia G wrote the paper.
Conflict-of-interest statement: The authors declare that they have no conflicts of interest.
Data sharing statement: No additional data are available.
Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Correspondence to: Salvatore Annunziata, MD, Institute of Nuclear Medicine, Department of Bioimaging and Radiological Sciences, Catholic University of the Sacred Heart, Largo Agostino Gemelli 8, 00168 Rome, Italy. salvatoreannunziata@live.it
Telephone: +39-6-30154978 Fax: +39-6-3058185
Received: May 26, 2015
Peer-review started: May 29, 2015
First decision: June 19, 2015
Revised: July 15, 2015
Accepted: September 14, 2015
Article in press: September 15, 2015
Published online: October 28, 2015
Processing time: 149 Days and 19 Hours

Abstract

AIM: To meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the evaluation of primary tumor in patients with gallbladder cancer (GBCa).

METHODS: A comprehensive literature search of studies published through 30th June 2014 regarding the role of 18F-FDG PET and PET/CT in the evaluation of primary gallbladder cancer (GBCa) was performed. All retrieved studies were reviewed. Pooled sensitivity and specificity of 18F-FDG PET or PET/CT in the evaluation of primary GBCa were calculated. The area under the summary receiving operator characteristics curve (AUC) was calculated to measure the accuracy of these methods. Sub-analyses considering the device used (PET vs PET/CT) were carried out.

RESULTS: Twenty-one studies comprising 495 patients who underwent 18F-FDG PET or PET/CT for suspicious GBCa were selected for the systematic review. The meta-analysis of 13 selected studies provided the following results: sensitivity 87% (95%CI: 82%-92%), specificity 78% (95%CI: 68%-86%). The AUC was 0.88. Improvement of sensitivity and specificity was observed when PET/CT was used.

CONCLUSION: 18F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of primary tumor in GBCa patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. PET/CT seems to have a better diagnostic accuracy than PET alone in this setting.

Key Words: Positron emission tomography; Positron emission tomography/computed tomography; Fluorine-18-fluorodeoxyglucose; Gallbladder cancer

Core tip: Fluorine-18-fluorodeoxyglucose-positron emission tomography (PET) and PET/computed tomography (CT) demonstrated to be useful diagnostic imaging methods in the assessment of primary tumor in gallbladder carcinoma patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. PET/CT seems to have a better diagnostic accuracy than PET alone in this setting.



INTRODUCTION

Gallbladder carcinoma (GBCa) is the most common carcinoma derived from biliary cells. It is one of the most common carcinoma of gastro-enteric system[1].

The only curative treatment is surgery, but the anatomical complexity of the porto-hepatic system, the morbidity and mortality of liver resection and the risk of tumoral spread induced by the manipulation of unknown GBCa, as well as the absence of effective chemotherapy, explain the high mortality resulting from these tumors[1].

Consequently, accurate evaluation and staging are critical to provide indication to surgery and to avoid unnecessary surgical interventions[2].

Several diagnostic tools have been used in this setting, including ultrasonography (US), computed tomography (CT), magnetic resonance (MR), endoscopic retrograde cholangiopancreatography (ERCP) and percutaneous transhepatic cholangiography (PTC).

Fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) and PET/CT have been proposed as non-invasive imaging methods to assess the disease extent in cancer patients. Since 18F-FDG is a glucose analogue, this radiopharmaceutical may be very useful in detecting malignant lesions which usually present high glucose metabolism[3]. Hybrid PET/CT device allows enhanced detection and characterization of neoplastic lesions, by combining the functional data obtained by PET with morphological data obtained by CT[3].

Several studies have evaluated the diagnostic accuracy of 18F-FDG-PET or PET/CT in the evaluation of primary tumor in patients with GBCa, reporting different values of sensitivity and specificity[1,2,4-22]. The purpose of our study is to systematically review and meta-analyze published data on this setting in order to provide more evidence-based data.

MATERIALS AND METHODS
Search strategy

A comprehensive computer literature search of PubMed/MEDLINE and EMBASE databases was carried out to find relevant published articles concerning the evaluation of primary tumor in patients with GBCa.

We used a search algorithm based on a combination of the terms: (1) “PET” OR “positron emission tomography”; and (2) “gallbladder” or “gall” or ”gall-bladder”. Only articles in English language were considered. The search was performed from inception to June 30th, 2014. To expand our search, references of the retrieved articles were also screened for additional studies.

Study selection

Studies or subsets in studies investigating the accuracy of 18F-FDG PET or PET/CT in the evaluation of primary GBCa were eligible for inclusion. Case reports, small case series, review articles, letters, editorials, and conference proceedings were excluded. The following inclusion criteria were applied to select studies for this meta-analysis: (1) original studies in which 18F-FDG PET or PET/CT were performed in patients with GBCa or suspicious GBCa; (2) a sample size of at least nine patients with GBCa or suspicious GBCa; (3) sufficient data to reassess sensitivity and specificity of 18F-FDG PET or PET/CT in detecting the primary tumor in patients with GBCa; and (4) no data overlap.

Three researchers (SA, DAP and CC) independently reviewed titles and abstracts of the retrieved articles, applying the above-mentioned selection criteria. Articles were rejected if clearly ineligible. The same three researchers then independently evaluated the full-text version of the included articles to determine their eligibility for inclusion.

Data extraction

Information about basic study (authors, year of publication, country of origin), study design (prospective or retrospective), patients’ characteristics (number of patients with biliary ducts lesions performing 18F-FDG-PET or PET/CT, mean age, gender) and technical aspects (injected activity of 18F-FDG, time between injection and image acquisition) were collected.

Each study was analyzed to retrieve the number of true-positive (TP), true-negative (TN), false-positive (FP), and false-negative (FN) findings of 18F-FDG PET or PET/CT in patients with GBCa or suspicious GBCa, according to the reference standard. Only studies providing such complete information were finally included in the meta-analysis.

Quality assessment

The 2011 Oxford Center for Evidence-Based Medicine checklist for diagnostic studies was used for quality assessment of the studies included in the meta-analysis. This checklist has 5 major parts as follows: representative spectrum of the patients, consecutive patient recruitment, ascertainment of the gold standard regardless of the index test results, independent blind comparison between the gold standard and index test results, enough explanation of the test to permit replication.

Statistical analysis

Sensitivity and specificity of 18F-FDG PET and PET/CT in the evaluation primary GBCa were obtained from the individual studies, on a per patient-based analysis. We considered as positive a biliary ducts lesion with increased uptake of 18F-FDG, according to the criteria reported by the different authors. When a positive lesion was histologically confirmed as malignant, this was considered a TP lesion, whereas an histologically confirmed benign lesion was considered as a FP lesion. We considered as negative a lesion with no uptake of 18F-FDG: when the lesion was histologically confirmed as malignant, this was considered a FN lesion, whereas a histologically confirmed benign lesion was considered as a TN lesion.

Sensitivity was determined according to the following formula: TP/(TP+FN); specificity was determined according to this formula: TN/(TN+FP). Statistical pooling of the data was performed by means of a random effects model. Pooled data are presented with 95% confidence intervals (95%CI). Heterogeneity between studies was assessed by a I2 index. A summary receiving operator characteristics (ROC) curve was obtained for selected studies and area under the curve (AUC) was calculated to assess the overall accuracy of 18F-FDG PET and PET/CT.

Subsequently, subgroup analyses were also performed, calculating the pooled sensitivity and specificity of 18F-FDG PET and PET/CT in two groups based on the different device used (PET or PET/CT).

Statistical analyses were performed using Meta-DiSc statistical software version 1.4.

RESULTS
Literature search

The comprehensive computer literature search from PubMed/MEDLINE and EMBASE databases revealed 250 articles. Reviewing titles and abstracts, 229 records were excluded as reviews, editorials or letters, case reports or case series or no direct link with the main subject. Finally, 21 articles including 495 patients were selected and were eligible for the systematic review[1,2,4-22]; no additional studies were found screening the references of these articles. The characteristics of the included studies are presented in Table 1, Table 2 and Table 3.

Table 1 Basic characteristics of the studies included in the systematic review.
Ref.YearCountryStudy designPatients performing 18F-FDG-PET or PET/CT with GB lesionsMean age (yr)Gender (%male)
Koh et al[4]2003JapanNR166844%
Anderson et al[5]2004United StatesNR146557%
Rodríguez-Fernández et al[6]2004SpainNR166831%
Wakabayashi et al[7]2005JapanProspective307150%
Nishiyama et al[8]2006JapanRetrospective327037%
Oe et al[9]2006JapanRetrospective126866%
Petrowsky et al[10]2006SwitzerlandProspective14NRNR
Shukla et al[11]2008IndiaNR244533%
Corvera et al[12]2008United StatesRetrospective416252%
Furukawa et al[13]2008JapanRetrospective18NRNR
Furukawa et al[14]2009JapanRetrospective18NRNR
Butte et al[15]2009ChileProspective535720%
Lee et al[16]2010South KoreaRetrospective16NRNR
Zhu et al[17]2010United StatesNR10NRNR
Lee et al[18]2012South KoreaRetrospective206545%
Kumar et al[19]2012IndiaRetrospective495231%
Yamada et al[20]2012JapanRetrospective14NRNR
Albazaz et al[2]2013United KingdomRetrospective30NRNR
Lee et al[21]2013South KoreaRetrospective9NRNR
Onal et al[22]2013TurkeyRetrospective106370%
Ramos-Font et al[1]2014SpainProspective496843%
Table 2 Technical characteristics of the studies included in the systematic review.
Ref.YearDevice18F-FDG mean injected dose (MBq)Time between 18F-FDG injection and image acquisition (min)Image analysisOther imaging methods performed
Koh et al[4]2003PET18560VisualCT
Anderson et al[5]2004PET37060VisualCT, MRI
Rodríguez-Fernández et al[6]2004PET37045-60Visual and semiquantitativeUS, CT
Wakabayashi et al[7]2005PET18560VisualCT
Nishiyama et al[8]2006PET185-37040-55Visual and semiquantitativeUS, CT
Oe et al[9]2006PET3/kg62-146Visual and semiquantitativeUS, CT, MRI
Petrowsky et al[10]2006PET/CT37045Visual and semiquantitativeCT
Shukla et al[11]2008PET/CT37060VisualCT
Corvera et al[12]2008PET370-555NRVisual and semiquantitativeCT, MRI
Furukawa et al[13]2008PET200-25060VisualCT
Furukawa et al[14]2009PET200-25060Visual and SemiquantitativeCT, MRI, PTC
Butte et al[15]2009PET/CT37060Visual and semiquantitativeNR
Lee et al[16]2010PET/CT370-55560Visual and semiquantitativeCT
Zhu et al[17]2010PET or PET/TC370-55545Visual and SemiquantitativeCT
Lee et al[18]2012PET/CT37045-60VisualNR
Kumar et al[19]2012PET/CT5.5/kg60Visual and semiquantitativeNR
Yamada et al[20]2012PET4.5/kg60Visual and semiquantitativeNR
Albazaz et al[2]2013PET/CT40060Visual and semiquantitativeCT, MRI
Lee et al[21]2013PET/CT370-55560Visual and semiquantitativeCT, MRCP, ERCP, EUS
Onal et al[22]2013PET/CT370-55560Visual and SemiquantitativeMRI, CT
Ramos-Font et al[1]2014PET/CT37060Visual and semiquantitativeNR
Table 3 Diagnostic accuracy data of fluorine-18-fluorodeoxyglucose-positron emission tomography and positron emission tomography/computed tomography on a per patient-based analysis.
Ref.YearOverall
PET
PET/CT
TPFPFNTNTPFPFNTNTPFPFNTN
Koh et al[4]200361276127NRNRNRNR
Anderson et al[5]200471247124NRNRNRNR
Rodríguez-Fernández et al[6]200442194219NRNRNRNR
Nishiyama et al[8]20061954419544NRNRNRNR
Oe et al[9]200631023102NRNRNRNR
Petrowsky et al[10]200614100NRNRNRNR14100
Corvera et al[12]20082414224142NRNRNRNR
Furukawa et al[13]20081701217010NRNRNRNR
Lee et al[16]201014020NRNRNRNR14020
Lee et al[18]2012166424NRNRNRNR166424
Yamada et al[20]201291409140NRNRNRNR
Albazaz et al[2]201315100NRNRNRNR15100
Ramos-Font et al[1]2014202015NRNRNRNR252022
Qualitative analysis (systematic review)

Using the database search, 21 original articles written over the past 11 years were selected[1,2,4-22]. About the study design, 4 of these studies were prospective[1,7,10,15], 12 retrospective[2,8,9,12-14,16,18-22] and in 5 articles this information was not provided[4-6,11,17]. Ten studies used hybrid PET/CT[1,2,10,11,15,16,18,19,21,22], ten studies used PET only[4-9,12-14,20], one study used both PET or PET/CT[17]. Heterogeneous technical aspects between the included studies were found (Table 2). PET image analysis was performed by using qualitative criteria (visual analysis) in all the included studies[1,2,4-22] and adjunctive semi-quantitative criteria [based on the calculation of the standardized uptake value (SUV)] in 15 articles[1,2,6,8-10,12,14-17,19-22].

The reference standard used to validate the 18F-FDG PET or PET/CT findings in the included studies were quite different.

Quantitative analysis (meta-analysis)

Only 13 over 21 studies included in the systematic review had sufficient data to calculate the pooled sensitivity[1,2,4-6,8-10,12,13,16,18,20], whereas only 9 studies[1,4-9,12,13,18] provided information about TN and FP lesions, thus allowing to assess pooled specificity. The diagnostic accuracy values of 18F-FDG PET and PET/CT in the studies included in the meta-analysis are presented in Figures 1 and 2.

Figure 1
Figure 1 Sensitivity values of fluorine-18-fluorodeoxyglucose positron emission tomography and positron emission tomography/computed tomography in the studies (n = 13) included in the meta-analysis.
Figure 2
Figure 2 Specificity values of fluorine-18-fluorodeoxyglucose positron emission tomography and positron emission tomography/computed tomography in the studies (n = 9) included in the meta-analysis.

Sensitivity and specificity values of 18F-FDG PET or PET/CT on a per patient-based analysis ranged from 69% to 100% and from 44% to 100%, with pooled estimates of 87% (95%CI: 82%-92%) and 78% (95%CI: 68%-86%), respectively. The area under the summary ROC curve was 0.88 (Figure 3). The included studies showed mild statistical heterogeneity (I2: 42%) in their estimate of sensitivity only.

Figure 3
Figure 3 Receiving operator characteristics curve analysis of accuracy values of studies (n = 9) included in the meta-analysis.

Subgroup analyses considering the different device used (PET or PET/CT) were performed. In studies in which 18F-FDG PET was used, values of sensitivity (8 eligible studies) and specificity (8 eligible studies) on a per patient-based analysis ranged from 69% to 100% and from 0% to 100%, respectively, with pooled estimates of 83% (95%CI: 75%-90%) and 71% (95%CI: 55%-84%), respectively. No statistical heterogeneity was found in these sub-analyses.

In studies in which hybrid 18F-FDG PET/CT was used, values of sensitivity (5 eligible studies) and specificity (4 eligible studies) on a per patient-based analysis ranged from 80% to 100% and from 0% to 88%, respectively, with pooled estimates of 93% (95%CI: 85%-97%) and 80% (95%CI: 66%-90%), respectively. Statistical heterogeneity was found both in their estimate of sensitivity (I2 = 65%) and specificity (I2 = 59%).

DISCUSSION

To the best of our knowledge, this meta-analysis is the first to evaluate the diagnostic accuracy of 18F-FDG PET and PET/CT in the evaluation of primary tumor in patients with GBCa. Several studies have used 18F-FDG PET or PET/CT in this setting reporting different values of sensitivity and specificity. However, many of these studies have limited power, analyzing only relatively small numbers of patients. In order to derive more robust estimates of the diagnostic accuracy of 18F-FDG PET or PET/CT in this setting we pooled published studies. A systematic review process was adopted in ascertaining studies, thereby avoiding selection bias[23].

Pooled results of our meta-analysis indicate that 18F-FDG PET or PET/CT have a good sensitivity (87%) and specificity (78%) in the evaluation of primary tumor in patients with GBCa. Furthermore, the value of the AUC (0.88) demonstrates that 18F-FDG PET or PET/CT are accurate diagnostic methods in this setting.

Possible sources of false-positive results (such as inflammatory diseases of the gallbladder) and false negative results (such as small size and/or low-grade tumors) should be considered.

A subgroup analysis considering different device used (PET vs PET/CT) was performed. We found higher pooled sensitivity and specificity when PET/CT was used compared to PET. This is not surprising considering the higher diagnostic accuracy of PET/CT compared to PET imaging[3].

Regarding the diagnostic work-up of patients with GBCa, 18F-FDG PET and PET/CT may have little diagnostic advantage over traditional imaging modalities in detecting primary GBCa[2]. 18F-FDG PET and PET/CT can be complementary to US, MR, CT, PTC and ERCP in staging GBCa patients. Since 18F-FDG PET is a whole-body scanning technique, it allows detection of unsuspected metastatic lymph nodes or distant spread that may lead to major changes in the surgical management of patients with biliary tract cancer[20]. Nevertheless, the diagnostic performance of 18F-FDG PET or PET/CT in detecting metastatic lymph nodes or distant spread was not object of our analysis.

This meta-analysis has some limitations such as the heterogeneity between the studies, the publication bias and the limited number of articles available for the subgroup analysis.

Heterogeneity between studies may represent a potential source of bias in a meta-analysis. This heterogeneity is likely to arise through diversity in methodological aspects between different studies. The baseline differences among the patients in the included studies, the reference standard used, and the study quality may contribute to the heterogeneity of the results too. In our pooled analysis the included studies were statistically mild heterogeneous in their estimate of pooled sensitivity only.

Publication bias is a major concern in all meta-analyses as studies reporting significant findings are more likely to be published than those reporting non-significant results. Indeed, it is not unusual for small-sized early studies to report a positive relationship that subsequent larger studies fail to replicate. We cannot exclude a publication bias in our meta-analysis.

Only a limited number of articles were available for the subgroup analysis based on the different device used (PET vs PET/CT) and this could limit the statistical power of the subgroup analysis.

Overall, 18F-FDG PET and PET/CT demonstrated to be quite accurate non-invasive tools in the evaluation of primary tumors in patients with GBCa. Nevertheless, multicentric studies and cost-effectiveness analyses about the role of 18F-FDG PET/CT in this setting are needed.

18F-FDG-PET and PET/CT demonstrated to be quite accurate diagnostic imaging methods in the evaluation of primary tumors in patients with GBCa. PET/CT seems to have a better diagnostic accuracy than PET alone in this setting.

COMMENTS
Background

Several studies have evaluated the diagnostic accuracy of fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) or PET/computed tomography (CT) in the evaluation of primary tumor in patients with gallbladder cancer (GBCa), reporting different values of sensitivity and specificity.

Applications

18F-FDG-PET and PET/CT demonstrated to be quite accurate diagnostic imaging methods in the evaluation of primary tumors in patients with GBCa. PET/CT seems to have a better diagnostic accuracy than PET alone in this setting.

Peer-review

It is an interesting article. This article was well designed meta-analysis about gallbladder cancer diagnosis.

Footnotes

P- Reviewer: Cariati A, Lee KG S- Editor: Ma YJ L- Editor: A E- Editor: Liu XM

References
1.  Ramos-Font C, Gómez-Rio M, Rodríguez-Fernández A, Jiménez-Heffernan A, Sánchez Sánchez R, Llamas-Elvira JM. Ability of FDG-PET/CT in the detection of gallbladder cancer. J Surg Oncol. 2014;109:218-224.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 39]  [Cited by in F6Publishing: 45]  [Article Influence: 4.1]  [Reference Citation Analysis (1)]
2.  Albazaz R, Patel CN, Chowdhury FU, Scarsbrook AF. Clinical impact of FDG PET-CT on management decisions for patients with primary biliary tumours. Insights Imaging. 2013;4:691-700.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 24]  [Cited by in F6Publishing: 27]  [Article Influence: 2.5]  [Reference Citation Analysis (0)]
3.  Treglia G, Cason E, Fagioli G. Recent applications of nuclear medicine in diagnostics (first part). Ital J Med. 2010;4:84-91.  [PubMed]  [DOI]  [Cited in This Article: ]
4.  Koh T, Taniguchi H, Yamaguchi A, Kunishima S, Yamagishi H. Differential diagnosis of gallbladder cancer using positron emission tomography with fluorine-18-labeled fluoro-deoxyglucose (FDG-PET). J Surg Oncol. 2003;84:74-81.  [PubMed]  [DOI]  [Cited in This Article: ]
5.  Anderson CD, Rice MH, Pinson CW, Chapman WC, Chari RS, Delbeke D. Fluorodeoxyglucose PET imaging in the evaluation of gallbladder carcinoma and cholangiocarcinoma. J Gastrointest Surg. 2004;8:90-97.  [PubMed]  [DOI]  [Cited in This Article: ]
6.  Rodríguez-Fernández A, Gómez-Río M, Llamas-Elvira JM, Ortega-Lozano S, Ferrón-Orihuela JA, Ramia-Angel JM, Mansilla-Roselló A, Martínez-del-Valle MD, Ramos-Font C. Positron-emission tomography with fluorine-18-fluoro-2-deoxy-D-glucose for gallbladder cancer diagnosis. Am J Surg. 2004;188:171-175.  [PubMed]  [DOI]  [Cited in This Article: ]
7.  Wakabayashi H, Akamoto S, Yachida S, Okano K, Izuishi K, Nishiyama Y, Maeta H. Significance of fluorodeoxyglucose PET imaging in the diagnosis of malignancies in patients with biliary stricture. Eur J Surg Oncol. 2005;31:1175-1179.  [PubMed]  [DOI]  [Cited in This Article: ]
8.  Nishiyama Y, Yamamoto Y, Fukunaga K, Kimura N, Miki A, Sasakawa Y, Wakabayashi H, Satoh K, Ohkawa M. Dual-time-point 18F-FDG PET for the evaluation of gallbladder carcinoma. J Nucl Med. 2006;47:633-638.  [PubMed]  [DOI]  [Cited in This Article: ]
9.  Oe A, Kawabe J, Torii K, Kawamura E, Higashiyama S, Kotani J, Hayashi T, Kurooka H, Tsumoto C, Kubo S. Distinguishing benign from malignant gallbladder wall thickening using FDG-PET. Ann Nucl Med. 2006;20:699-703.  [PubMed]  [DOI]  [Cited in This Article: ]
10.  Petrowsky H, Wildbrett P, Husarik DB, Hany TF, Tam S, Jochum W, Clavien PA. Impact of integrated positron emission tomography and computed tomography on staging and management of gallbladder cancer and cholangiocarcinoma. J Hepatol. 2006;45:43-50.  [PubMed]  [DOI]  [Cited in This Article: ]
11.  Shukla PJ, Barreto SG, Arya S, Shrikhande SV, Hawaldar R, Purandare N, Rangarajan V. Does PET-CT scan have a role prior to radical re-resection for incidental gallbladder cancer? HPB (Oxford). 2008;10:439-445.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 42]  [Cited by in F6Publishing: 37]  [Article Influence: 2.3]  [Reference Citation Analysis (0)]
12.  Corvera CU, Blumgart LH, Akhurst T, DeMatteo RP, D’Angelica M, Fong Y, Jarnagin WR. 18F-fluorodeoxyglucose positron emission tomography influences management decisions in patients with biliary cancer. J Am Coll Surg. 2008;206:57-65.  [PubMed]  [DOI]  [Cited in This Article: ]
13.  Furukawa H, Ikuma H, Asakura-Yokoe K, Uesaka K. Preoperative staging of biliary carcinoma using 18F-fluorodeoxyglucose PET: prospective comparison with PET+CT, MDCT and histopathology. Eur Radiol. 2008;18:2841-2847.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 36]  [Cited by in F6Publishing: 25]  [Article Influence: 1.6]  [Reference Citation Analysis (0)]
14.  Furukawa H, Ikuma H, Asakura K, Uesaka K. Prognostic importance of standardized uptake value on F-18 fluorodeoxyglucose-positron emission tomography in biliary tract carcinoma. J Surg Oncol. 2009;100:494-499.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 25]  [Cited by in F6Publishing: 26]  [Article Influence: 1.7]  [Reference Citation Analysis (0)]
15.  Butte JM, Redondo F, Waugh E, Meneses M, Pruzzo R, Parada H, Amaral H, De La Fuente HA. The role of PET-CT in patients with incidental gallbladder cancer. HPB (Oxford). 2009;11:585-591.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 39]  [Cited by in F6Publishing: 39]  [Article Influence: 2.6]  [Reference Citation Analysis (0)]
16.  Lee SW, Kim HJ, Park JH, Park DI, Cho YK, Sohn CI, Jeon WK, Kim BI. Clinical usefulness of 18F-FDG PET-CT for patients with gallbladder cancer and cholangiocarcinoma. J Gastroenterol. 2010;45:560-566.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 95]  [Cited by in F6Publishing: 81]  [Article Influence: 5.8]  [Reference Citation Analysis (0)]
17.  Zhu AX, Meyerhardt JA, Blaszkowsky LS, Kambadakone AR, Muzikansky A, Zheng H, Clark JW, Abrams TA, Chan JA, Enzinger PC. Efficacy and safety of gemcitabine, oxaliplatin, and bevacizumab in advanced biliary-tract cancers and correlation of changes in 18-fluorodeoxyglucose PET with clinical outcome: a phase 2 study. Lancet Oncol. 2010;11:48-54.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 213]  [Cited by in F6Publishing: 217]  [Article Influence: 14.5]  [Reference Citation Analysis (0)]
18.  Lee J, Yun M, Kim KS, Lee JD, Kim CK. Risk stratification of gallbladder polyps (1-2 cm) for surgical intervention with 18F-FDG PET/CT. J Nucl Med. 2012;53:353-358.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 40]  [Cited by in F6Publishing: 32]  [Article Influence: 2.7]  [Reference Citation Analysis (0)]
19.  Kumar R, Sharma P, Kumari A, Halanaik D, Malhotra A. Role of 18F-FDG PET/CT in detecting recurrent gallbladder carcinoma. Clin Nucl Med. 2012;37:431-435.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 30]  [Cited by in F6Publishing: 20]  [Article Influence: 1.7]  [Reference Citation Analysis (0)]
20.  Yamada I, Ajiki T, Ueno K, Sawa H, Otsubo I, Yoshida Y, Shinzeki M, Toyama H, Matsumoto I, Fukumoto T. Feasibility of (18)F-fluorodeoxyglucose positron-emission tomography for preoperative evaluation of biliary tract cancer. Anticancer Res. 2012;32:5105-5110.  [PubMed]  [DOI]  [Cited in This Article: ]
21.  Lee JY, Kim HJ, Yim SH, Shin DS, Yu JH, Ju DY, Park JH, Park DI, Cho YK, Sohn CI. Primary tumor maximum standardized uptake value measured on 18F-fluorodeoxyglucose positron emission tomography-computed tomography is a prognostic value for survival in bile duct and gallbladder cancer. Korean J Gastroenterol. 2013;62:227-233.  [PubMed]  [DOI]  [Cited in This Article: ]
22.  Onal C, Topuk S, Yapar AF, Yavuz M, Topkan E, Yavuz A. Comparison of computed tomography- and positron emission tomography-based radiotherapy planning in cholangiocarcinoma. Onkologie. 2013;36:484-490.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 8]  [Cited by in F6Publishing: 8]  [Article Influence: 0.7]  [Reference Citation Analysis (0)]
23.  Treglia G, Sadeghi R. Meta-analyses and systematic reviews on PET and PET/CT in oncology: the state of the art. Clin Transl Imaging. 2013;1:73-75.  [PubMed]  [DOI]  [Cited in This Article: ]