1
|
Masciangelo G, Campana D, Ricci C, Andrini E, Rakichevikj E, Fusaroli P, Lisotti A. Endoscopic Ultrasound-Guided Locoregional Treatments for Pancreatic Neuroendocrine Neoplasms. Curr Oncol 2025; 32:113. [PMID: 39996913 PMCID: PMC11854204 DOI: 10.3390/curroncol32020113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2025] [Revised: 02/09/2025] [Accepted: 02/13/2025] [Indexed: 02/26/2025] Open
Abstract
Pancreatic neuroendocrine neoplasms (pNENs) represent approximately 2% of all solid pancreatic tumors. The incidence of pNENs has been increasing in the last decade. The clinical manifestations of pNENs range from hormone secretion syndromes in functioning neoplasms (F-pNENs) to local infiltration or distant metastases in late-stage diagnoses or incidental findings in small non-functioning neoplasms (NF-pNENs). While surgery is the gold-standard treatment for larger and more aggressive tumors, small and low-grade tumors (G1) may be followed-up due to the indolent course of disease. Recently, endoscopic ultrasound (EUS)-guided ablative techniques, such as ethanol injection (EUS-EI) and radiofrequency ablation (EUS-RFA), have emerged as promising options for loco-regional ablations in selected cases. Despite promising safety profile and efficacy, high-quality evidence is needed to support their widespread adoption. This article reviews the current state of EUS-guided locoregional therapies, patient selection criteria, procedural details, and associated risks.
Collapse
Affiliation(s)
- Graziella Masciangelo
- Gastroenterology Unit, Hospital of Imola, University of Bologna, 40026 Bologna, Italy; (G.M.); (E.R.); (P.F.)
| | - Davide Campana
- Department of Medical and Surgical Sciences (DIMEC), Medical Oncology Unit, Alma Mater Studiorum-University of Bologna, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy; (D.C.); (E.A.)
| | - Claudio Ricci
- Department of Internal Medicine and Surgery (DIMEC), Alma Mater Studiorum, University of Bologna, 40126 Bologna, Italy;
| | - Elisa Andrini
- Department of Medical and Surgical Sciences (DIMEC), Medical Oncology Unit, Alma Mater Studiorum-University of Bologna, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy; (D.C.); (E.A.)
| | - Emilija Rakichevikj
- Gastroenterology Unit, Hospital of Imola, University of Bologna, 40026 Bologna, Italy; (G.M.); (E.R.); (P.F.)
| | - Pietro Fusaroli
- Gastroenterology Unit, Hospital of Imola, University of Bologna, 40026 Bologna, Italy; (G.M.); (E.R.); (P.F.)
| | - Andrea Lisotti
- Gastroenterology Unit, Hospital of Imola, University of Bologna, 40026 Bologna, Italy; (G.M.); (E.R.); (P.F.)
| |
Collapse
|
2
|
Gheorghiu MI, Seicean A, Pojoga C, Hagiu C, Seicean R, Sparchez Z. Contrast-enhanced guided endoscopic ultrasound procedures. World J Gastroenterol 2024; 30:2311-2320. [PMID: 38813054 PMCID: PMC11130571 DOI: 10.3748/wjg.v30.i17.2311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2024] [Revised: 03/10/2024] [Accepted: 04/15/2024] [Indexed: 04/30/2024] Open
Abstract
Contrast-enhanced endoscopic ultrasound (CH-EUS) can overcome the limitations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of these tumours. Despite the initial enthusiasm that oriented needle sampling under CH-EUS guidance could provide better diagnostic yield in pancreatic solid lesions, further studies did not confirm the supplementary values in cases of tissue acquisition guided by CH-EUS. This review details the knowledge based on the available data on contrast-guided procedures. The indications for CH-EUS tissue acquisition include isoechoic EUS lesions with poor visible delineation where CH-EUS can differentiate the lesion vascularisation from the surrounding parenchyma and also the mural nodules within biliopancreatic cystic lesions, which occur in select cases. Additionally, the roles of CH-EUS-guided therapy in patients whose pancreatic fluid collections or bile ducts that have an echogenic content have indications for drainage, and patients who have nonvisualized vessels that need to be highlighted via Doppler EUS are presented. Another indication is represented if there is a need for an immediate assessment of the post-radiofrequency ablation of pancreatic neuroendocrine tumours, in which case CH-EUS can be used to reveal the incomplete tumour destruction.
Collapse
Affiliation(s)
- Marcel Ioan Gheorghiu
- Department of Gastroenterology, “Prof. Dr. Octavian Fodor” Regional Institute of Gastroenterology and Hepatology, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca 400162, Cluj, Romania
| | - Andrada Seicean
- Department of Gastroenterology, “Prof. Dr. Octavian Fodor” Regional Institute of Gastroenterology and Hepatology, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca 400162, Cluj, Romania
| | - Cristina Pojoga
- Department of Gastroenterology, “Prof. Dr. Octavian Fodor” Regional Institute of Gastroenterology and Hepatology, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca 400162, Cluj, Romania
- Department of Clinical Psychology and Psychotherapy, International Institute for Advanced Study of Psychotherapy and Applied Mental Health, Babeș-Bolyai University, Cluj-Napoca 400375, Cluj, Romania
| | - Claudia Hagiu
- Department of Gastroenterology, “Prof. Dr. Octavian Fodor” Regional Institute of Gastroenterology and Hepatology, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca 400162, Cluj, Romania
| | - Radu Seicean
- The First Surgical Clinic, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj Napoca 400006, Cluj, Romania
| | - Zeno Sparchez
- Department of Gastroenterology, “Prof. Dr. Octavian Fodor” Regional Institute of Gastroenterology and Hepatology, "Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca 400162, Cluj, Romania
| |
Collapse
|
3
|
Katrevula A, Singh AP, Giovannini M, Lakhtakia S, Duvvur NR. Contrast-enhanced harmonic EUS-guided radiofrequency ablation of hepatocellular carcinoma: a new horizon in endohepatology. VIDEOGIE : AN OFFICIAL VIDEO JOURNAL OF THE AMERICAN SOCIETY FOR GASTROINTESTINAL ENDOSCOPY 2023; 8:354-357. [PMID: 37719951 PMCID: PMC10500198 DOI: 10.1016/j.vgie.2023.05.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 09/19/2023]
Abstract
Video 1Contrast-enhanced harmonic EUS-guided radiofrequency ablation of hepatocellular carcinoma.
Collapse
Affiliation(s)
| | | | - Marc Giovannini
- Department of Medico-Surgical Digestive Oncology, Institute Paoli-Calmettes, Marseille, France
| | | | | |
Collapse
|
4
|
Sbeit W, Kadah A, Mahamid M, Mari A, Khoury T. A state-of-the-art comprehensive review summarizing the emerging data on endoscopic ultrasound-guided liver diseases management. Eur J Gastroenterol Hepatol 2021; 33:e13-e20. [PMID: 32804852 DOI: 10.1097/meg.0000000000001893] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Liver diseases are among the most common diseases worldwide accounting for substantial morbidity and mortality. Most liver diseases necessitate radiological evaluation or accurate diagnosis and recently for management as well. In the last decade, the application of therapeutic endoscopic ultrasound (EUS) procedure has been increasingly utilized for the management of various liver diseases. In this comprehensive narrative review article, we provide systematic overview on EUS-guided therapeutic interventions in various liver diseases summarizing most updated data regarding technical success, outcomes and safety profiles. Overall, 35 articles have reported on the use of EUS in the treatment of liver diseases with excellent technical success, favorable radiological response and high safety profiles for EUS-guided treatment of solid and cystic liver lesion and for EUS-guided angiotherapy for gastric varices, except for EUS-guided cyanoacrylate glue injection which was associated with life-threatening fatal systemic embolization adverse events. This suggests that EUS-guided intervention is a new promising therapeutic intervention for the treatment of various liver diseases with durable effect and a limited potential for adverse events.
Collapse
Affiliation(s)
- Wisam Sbeit
- Department of Gastroenterology, Galilee Medical Center, Nahariya
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed
| | - Anas Kadah
- Department of Gastroenterology, Galilee Medical Center, Nahariya
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed
| | - Mahmud Mahamid
- Gastroenterology Department, Sharee Zedek Medical Center, Jerusalem
| | - Amir Mari
- Gastroenterology and Endoscopy Units, The Nazareth Hospital, EMMS, Nazareth
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed, Israel
| | - Tawfik Khoury
- Department of Gastroenterology, Galilee Medical Center, Nahariya
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed
| |
Collapse
|
5
|
Dhar J, Samanta J. Role of endoscopic ultrasound in the field of hepatology: Recent advances and future trends. World J Hepatol 2021; 13:1459-1483. [PMID: 34904024 PMCID: PMC8637671 DOI: 10.4254/wjh.v13.i11.1459] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 07/19/2021] [Accepted: 09/03/2021] [Indexed: 02/06/2023] Open
Abstract
The role of endoscopic ultrasound (EUS) as a diagnostic and therapeutic modality for the management of various gastrointestinal diseases has been expanding. The imaging or intervention for various liver diseases has primarily been the domain of radiologists. With the advances in EUS, the domain of endosonologists is rapidly expanding in the field of hepatology. The ability to combine endoscopy and sonography in one hybrid device is a unique property of EUS, together with the ability to bring its probe/transducer near the liver, the area of interest. Its excellent spatial resolution and ability to provide real-time images coupled with several enhancement techniques, such as contrast-enhanced (CE) EUS, have facilitated the growth of EUS. The concept of "Endo-hepatology" encompasses the wide range of diagnostic and therapeutic procedures that are now gradually becoming feasible for managing various liver diseases. Diagnostic advancements can enable a wide array of techniques from elastography and liver biopsy for liver parenchymal diseases, to CE-EUS for focal liver lesions to portal pressure measurements for managing various liver conditions. Similarly, therapeutic advancements range from EUS-guided eradication of varices, drainage of bilomas and abscesses to various EUS-guided modalities of liver tumor management. We provide a comprehensive review of all the different diagnostic and therapeutic EUS modalities available for the management of various liver diseases. A synopsis of all the technical details involving each procedure and the available data has been tabulated, and the future trends in this area have been highlighted.
Collapse
Affiliation(s)
- Jahnvi Dhar
- Department of Gastroenterology, Post Graduate Institute of Medical Education and Research, Chandigarh 160012, India
| | - Jayanta Samanta
- Department of Gastroenterology, Post Graduate Institute of Medical Education and Research, Chandigarh 160012, India.
| |
Collapse
|
6
|
Pavic T, Mikolasevic I, Kralj D, Blazevic N, Skrtic A, Budimir I, Lerotic I, Hrabar D. Role of Endoscopic Ultrasound in Liver Disease: Where Do We Stand? Diagnostics (Basel) 2021; 11:2021. [PMID: 34829368 PMCID: PMC8618190 DOI: 10.3390/diagnostics11112021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 10/25/2021] [Accepted: 10/29/2021] [Indexed: 12/13/2022] Open
Abstract
As the burden of liver disease in the general populace steadily increases, so does the need for both advanced diagnostic and treatment options. Endoscopic ultrasound is a reliable diagnostic and therapeutic method that has an established role, foremost in pancreatobiliary pathology. This paper aims to summarize the growing role of endoscopic ultrasound in hepatology based on the search of the current literature. A number of applications of endoscopic ultrasound are reviewed, including both noninvasive methods and tissue acquisition in focal and diffuse liver disease, portal hypertension measurement, detection and management of gastric and esophageal varices, treatment of focal liver lesions and staging of pancreatobiliary malignancies, treatment of cystic and solid liver lesions, as well as liver abscess drainage. Both hepatologists and endoscopists should be aware of the evolving role of endoscopic ultrasound in liver disease. The inherent invasive nature of endoscopic examination limits its use to a targeted population identified using noninvasive methods. Endoscopic ultrasound is one the most versatile methods in gastroenterology, allowing immediate access with detection, sampling, and treatment of digestive tract pathology. Further expansion of its use in hepatology is immanent.
Collapse
Affiliation(s)
- Tajana Pavic
- Department of Gastroenterology and Hepatology, University Hospital Center Sestre Milosrdnice, 10000 Zagreb, Croatia; (D.K.); (N.B.); (I.B.); (I.L.); (D.H.)
| | - Ivana Mikolasevic
- Department of Gastroenterology, University Hospital Center Rijeka, 51000 Rijeka, Croatia;
| | - Dominik Kralj
- Department of Gastroenterology and Hepatology, University Hospital Center Sestre Milosrdnice, 10000 Zagreb, Croatia; (D.K.); (N.B.); (I.B.); (I.L.); (D.H.)
| | - Nina Blazevic
- Department of Gastroenterology and Hepatology, University Hospital Center Sestre Milosrdnice, 10000 Zagreb, Croatia; (D.K.); (N.B.); (I.B.); (I.L.); (D.H.)
| | - Anita Skrtic
- Department of Pathology, Merkur University Hospital, 10000 Zagreb, Croatia;
| | - Ivan Budimir
- Department of Gastroenterology and Hepatology, University Hospital Center Sestre Milosrdnice, 10000 Zagreb, Croatia; (D.K.); (N.B.); (I.B.); (I.L.); (D.H.)
| | - Ivan Lerotic
- Department of Gastroenterology and Hepatology, University Hospital Center Sestre Milosrdnice, 10000 Zagreb, Croatia; (D.K.); (N.B.); (I.B.); (I.L.); (D.H.)
| | - Davor Hrabar
- Department of Gastroenterology and Hepatology, University Hospital Center Sestre Milosrdnice, 10000 Zagreb, Croatia; (D.K.); (N.B.); (I.B.); (I.L.); (D.H.)
| |
Collapse
|
7
|
Binda C, Coluccio C, Marocchi G, Sbrancia M, Fabbri C. The Role of Contrast-Enhanced Harmonic Endoscopic Ultrasound in Interventional Endoscopic Ultrasound. MEDICINA (KAUNAS, LITHUANIA) 2021; 57:1085. [PMID: 34684120 PMCID: PMC8539792 DOI: 10.3390/medicina57101085] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 10/06/2021] [Accepted: 10/07/2021] [Indexed: 01/03/2023]
Abstract
Over the last decades, contrast-enhanced harmonic endoscopic ultrasound (CH-EUS) has emerged as an important diagnostic tool for the diagnosis and differentiation of several gastrointestinal diseases. The key advantage of CH-EUS is that the influx and washout of contrast in the target lesion can be observed in real time, accurately depicting microvasculature. CH-EUS is established as an evidence-based technique complementary to B-mode EUS to differentiate solid appearing structures, to characterize mass lesions, and to improve the staging of gastrointestinal and pancreatobiliary cancer. In the last few years, interest has increased in the use of CH-EUS in interventional procedures such as tissue acquisition, tumor ablation, biliary drainage, and the management of pancreatic fluid collections. The aim of this narrative review is to evaluate the available evidence and future expectations of CH-EUS in interventional EUS.
Collapse
Affiliation(s)
- Cecilia Binda
- Gastroenterology and Digestive Endoscopy Unit, Forlì-Cesena Hospitals, AUSL Romagna, 47121 Forlì, Italy; (C.C.); (G.M.); (M.S.); (C.F.)
| | - Chiara Coluccio
- Gastroenterology and Digestive Endoscopy Unit, Forlì-Cesena Hospitals, AUSL Romagna, 47121 Forlì, Italy; (C.C.); (G.M.); (M.S.); (C.F.)
| | - Gianmarco Marocchi
- Gastroenterology and Digestive Endoscopy Unit, Forlì-Cesena Hospitals, AUSL Romagna, 47121 Forlì, Italy; (C.C.); (G.M.); (M.S.); (C.F.)
- Department of Medical and Surgical Sciences-DIMEC, Alma Mater Studiorum University of Bologna, 40138 Bologna, Italy
| | - Monica Sbrancia
- Gastroenterology and Digestive Endoscopy Unit, Forlì-Cesena Hospitals, AUSL Romagna, 47121 Forlì, Italy; (C.C.); (G.M.); (M.S.); (C.F.)
| | - Carlo Fabbri
- Gastroenterology and Digestive Endoscopy Unit, Forlì-Cesena Hospitals, AUSL Romagna, 47121 Forlì, Italy; (C.C.); (G.M.); (M.S.); (C.F.)
| |
Collapse
|
8
|
Hashimoto R, Chang KJ. Endoscopic ultrasound guided hepatic interventions. Dig Endosc 2021; 33:54-65. [PMID: 32145117 DOI: 10.1111/den.13661] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2019] [Accepted: 03/03/2020] [Indexed: 02/08/2023]
Abstract
Intervention for liver disease has predominantly been performed through the percutaneous approach. However, as endoscopic ultrasound (EUS) applications have expanded, there have emerged various EUS-guided interventions for liver disease, a space we call "Endo-Hepatology". EUS-guided liver biopsy can be considered the "forerunner" of Endo-Hepatology and has become a clinical option for patients requiring histologic diagnosis and staging of their liver disease. EUS also enables direct access to the portal vein. Subsequently, many procedures are being explored, such as angiography, measurement of the portosystemic pressure gradient, portal vein sampling to detect cancer cell or DNA, and EUS-guided transhepatic intrahepatic portosystemic shunt creation. Since the transducer is close to the liver, especially the left and caudate lobes, EUS can be used as a rescue when the percutaneous approach is not favorable and EUS-guided treatments of liver tumor, cyst and abscess have been reported. This review summarizes the available studies of EUS-guided intervention in the liver.
Collapse
Affiliation(s)
- Rintaro Hashimoto
- H. H. Chao Comprehensive Digestive Center, University of California Irvine Medical Center, Orange, USA
| | - Kenneth J Chang
- H. H. Chao Comprehensive Digestive Center, University of California Irvine Medical Center, Orange, USA
| |
Collapse
|
9
|
Marocchi G, Lisotti A, Fusaroli P. Contrast Harmonic-Enhanced Endoscopic Ultrasound (EUS) Is the Perfect Companion of EUS-Guided Tumor Ablation. Gut Liver 2020; 14:669-670. [PMID: 32773387 PMCID: PMC7492498 DOI: 10.5009/gnl20077] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 03/31/2020] [Accepted: 04/04/2020] [Indexed: 12/13/2022] Open
Affiliation(s)
- Gianmarco Marocchi
- Gastrointestinal Unit, Department of Medical and Surgical Sciences, Hospital of Imola, University of Bologna, Imola, Italy
| | - Andrea Lisotti
- Gastrointestinal Unit, Department of Medical and Surgical Sciences, Hospital of Imola, University of Bologna, Imola, Italy
| | - Pietro Fusaroli
- Gastrointestinal Unit, Department of Medical and Surgical Sciences, Hospital of Imola, University of Bologna, Imola, Italy
| |
Collapse
|
10
|
Sbeit W, Kadah A, Mari A, Mahamid M, Khoury T. A Comprehensive Narrative Review on the Evolving Role of Endoscopic Ultrasound in Focal Solid Liver Lesions Diagnosis and Management. Diagnostics (Basel) 2020; 10:688. [PMID: 32932960 PMCID: PMC7554970 DOI: 10.3390/diagnostics10090688] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 09/05/2020] [Accepted: 09/10/2020] [Indexed: 12/11/2022] Open
Abstract
The implications of endoscopic ultrasound (EUS) have expanded considerably in recent years to cover more fields in invasive gastroenterology practice, as both an investigative and therapeutic modality. The utility of EUS in the diagnosis and management of focal liver lesions has gained a special attractiveness recently. The EUS probe proximity to the liver and its excellent spatial resolution enables real-time images coupled with several enhancement techniques, such as contrast-enhanced (CE) EUS. Aside from its notable capability to execute targeted biopsies and therapeutic interventions, EUS has developed into a hopeful therapeutic tool for the management of solid liver lesions. Herein, we provide a comprehensive state-of-the-art review on the efficacy and safety of EUS in the diagnosis and management of focal solid liver lesions. Medline/PubMed and Embase database searches were conducted by two separate authors (T.K. and W.S.), all relevant studies were assessed, and relevant data was extracted and fully reported. EUS-guided diagnosis of focal liver lesions by sonographic morphologic appearance and cytological and histopathological finding of biopsies obtained via fine needle aspiration/biopsy have been shown to significantly improve the diagnosis of solid liver lesions compared with traditional imaging tools. Similarly, EUS-guided treatment has been shown to consistently have excellent technical success, high efficacy, and minor adverse events. The evolving valuable evidences of EUS utility might satisfy the unmet need of optimizing management of focal solid liver lesions.
Collapse
Affiliation(s)
- Wisam Sbeit
- Department of Gastroenterology, Galilee Medical Center, Nahariya 22100, Israel; (W.S.); (A.K.)
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed 1311502, Israel;
| | - Anas Kadah
- Department of Gastroenterology, Galilee Medical Center, Nahariya 22100, Israel; (W.S.); (A.K.)
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed 1311502, Israel;
| | - Amir Mari
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed 1311502, Israel;
- Gastroenterology and Endoscopy Units, The Nazareth Hospital, EMMS, Nazareth 16100, Israel
| | - Mahmud Mahamid
- Department of Gastroenterology and Liver Diseases, Shaare Zedek Medical Center, Jerusalem 9103102, Israel;
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem 9112102, Israel
| | - Tawfik Khoury
- Department of Gastroenterology, Galilee Medical Center, Nahariya 22100, Israel; (W.S.); (A.K.)
- Faculty of Medicine in the Galilee, Bar-Ilan University, Safed 1311502, Israel;
| |
Collapse
|