1
|
Itonaga M, Ashida R, Kitano M. Updated techniques and evidence for endoscopic ultrasound-guided tissue acquisition from solid pancreatic lesions. DEN OPEN 2025; 5:e399. [PMID: 38911353 PMCID: PMC11190023 DOI: 10.1002/deo2.399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2024] [Accepted: 06/03/2024] [Indexed: 06/25/2024]
Abstract
Endoscopic ultrasound-guided tissue acquisition (EUS-TA), including fine-needle aspiration (EUS-FNA) and fine-needle biopsy (EUS-FNB), has revolutionized specimen collection from intra-abdominal organs, especially the pancreas. Advances in personalized medicine and more precise treatment have increased demands to collect specimens with higher cell counts, while preserving tissue structure, leading to the development of EUS-FNB needles. EUS-FNB has generally replaced EUS-FNA as the procedure of choice for EUS-TA of pancreatic cancer. Various techniques have been tested for their ability to enhance the diagnostic performance of EUS-TA, including multiple methods of sampling at the time of puncture, on-site specimen evaluation, and specimen processing. In addition, advances in next-generation sequencing have made comprehensive genomic profiling of EUS-TA samples feasible in routine clinical practice. The present review describes updates in EUS-TA sampling techniques of pancreatic lesions, as well as methods for their evaluation.
Collapse
Affiliation(s)
- Masahiro Itonaga
- Second Department of Internal MedicineWakayama Medical UniversityWakayamaJapan
| | - Reiko Ashida
- Second Department of Internal MedicineWakayama Medical UniversityWakayamaJapan
| | - Masayuki Kitano
- Second Department of Internal MedicineWakayama Medical UniversityWakayamaJapan
| |
Collapse
|
2
|
Iglesias-Garcia J, de la Iglesia D, Fusaroli P. Endoscopic Ultrasound armamentarium for precise and early diagnosis of biliopancreatic lesions. Best Pract Res Clin Gastroenterol 2025; 74:101987. [PMID: 40210338 DOI: 10.1016/j.bpg.2025.101987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2025] [Accepted: 02/03/2025] [Indexed: 03/04/2025]
Abstract
The diagnostic paradigm for biliopancreatic lesions has been revolutionized by continuous advancements in endoscopic ultrasound (EUS) technologies and techniques. This review examines the expanding diagnostic toolkit available to clinicians, emphasizing innovations that have significantly enhanced precision and early detection capabilities. One of the most transformative advancements is the development of fine-needle biopsy (FNB) needles. Modern designs, including Franseen, and fork-tip configurations, have optimized tissue sampling, achieving diagnostic accuracies exceeding 90 % while minimizing the number of needle passes required. These innovations facilitate the acquisition of high-quality histological specimens suitable for comprehensive molecular profiling, paving the way for personalized therapeutic approaches. Concurrent advancements in sampling techniques have bolstered these needle design improvements. The fanning technique has been particularly effective, increasing diagnostic yields from 71 % to 88 %. Wet suction methods preserve tissue integrity better than traditional approaches, while standardized protocols for needle passes enhance procedural efficiency. For specimen evaluation, Rapid On-Site Evaluation (ROSE) offers 93 % sensitivity, while alternatives like Macroscopic On-Site Evaluation (MOSE) provide comparable accuracy while reducing dependency on specialized personnel and resources. Image enhancement technologies have markedly improved the ability to characterize lesions. Contrast Harmonic EUS (CH-EUS) is particularly effective in differentiating pancreatic cancer from other solid lesions, with meta-analyses confirming sensitivity and specificity of 94 % and 89 %, respectively. Its ability to detect lesions as small as 15 mm makes it invaluable for early diagnosis. In cystic lesions, CH-EUS excels in identifying malignant mural nodules, with diagnostic accuracies reaching 96 %. The integration of elastography and advanced digital imaging technologies has further expanded diagnostic capabilities. Strain elastography provides qualitative insights into tissue characteristics, while shear wave elastography offers quantitative measurements of stiffness, adding diagnostic precision. Similarly, technologies like detective flow imaging match the accuracy of contrast-enhanced techniques in pancreatic cancer detection and enhance vascular assessment. For cystic lesions, diagnostics have progressed beyond traditional fluid analysis. Techniques such as through-the-needle biopsy (TTNB) have improved diagnostic yields to 74 %, albeit with a modest risk of complications. Incorporating molecular markers and next-generation sequencing allows differentiation between cystic lesion subtypes and more accurate assessment of malignant potential. This array of diagnostic tools offers unprecedented potential for early and precise diagnosis of biliopancreatic lesions. Integrating these innovations into clinical practice requires careful consideration of their strengths and limitations. Future research should aim to standardize protocols and establish evidence-based algorithms for their combined use, with the ultimate goal of improving patient outcomes through earlier detection and tailored management of biliopancreatic pathologies.
Collapse
Affiliation(s)
- Julio Iglesias-Garcia
- Department of Gastroenterology and Hepatology, University Hospital of Santiago de Compostela, Health Research Institute of Santiago de Compostela, Spain
| | - Daniel de la Iglesia
- Gastroenterology Department, University Hospital of Puerta de Hierro, Madrid, Spain.
| | - Pietro Fusaroli
- Gastrointestinal Unit, University of Bologna/Hospital of Imola, Italy
| |
Collapse
|
3
|
Zhu Y, Su Y, Yang P, Li J, Yu T, Wang Y, Zhou X, Zhao M, Sun X, Shan J. Comparation of 5 ml and 10 ml Negative Pressures with Wet-suction Techniques for EUS-FNA of Solid Lesions: A Single-center Randomized Controlled Trial. J Clin Gastroenterol 2025; 59:97-103. [PMID: 38359147 DOI: 10.1097/mcg.0000000000001982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 01/13/2024] [Indexed: 02/17/2024]
Abstract
BACKGROUND AND OBJECTIVES The negative pressure selectable for the wet-suction technique remains uncertain. The aim was to investigate the quality of sampling and diagnostic accuracy with solid lesions by 5 mL and 10 mL negative pressure with wet-suction techniques. METHODS This is a single-center, crossover, randomized controlled trial conducted with a random sampling technique. In all, 160 patients consecutively undergoing EUS-FNA for solid lesions were randomized in a ratio of 1:1 into 2 groups, the 5 mL and 10 mL negative pressure wet-suction group. The main outcome was to compare the sample quality between the 2 groups. The secondary outcome was to compare the histologic and cytologic diagnostic accuracy of solid lesions. RESULTS Pancreatic (n=129) and nonpancreatic (n=27) lesions from 156 lesions were examined. The sample quality concluding cellularity, adequacy, integrity, and blood contamination were comparable between the 2 groups. However, in subgroup analysis, we found 19G FNA provided more integrity of specimen in 5 mL than in 10 mL group (100% vs. 82.9%, P =0.025). In contrast, this benefit was not noteworthy in the 22G FNA subgroup. And there was no statistically significant in histologic (87.82% vs. 87.18%, P =1.000) and cytologic (78.85% vs. 80.77%, P =0.778) accuracy between 5 mL and 10 mL groups. CONCLUSION When using the wet-suction technique, 5 mL and 10 mL negative pressure offer equivalent sample quality and diagnostic accuracy. However, the 19G FNA can obtain better sample quality with 5 mL negative pressure than 10 mL negative pressure.
Collapse
Affiliation(s)
- Yuchun Zhu
- Department of Clinical Medicine, North Sichuan Medical College, Fujiang Road, Nanchong
- Department of Gastroenterology
| | - Yang Su
- Department of Gastroenterology
- Department of Gastroenterology, College of Medicine, Southwest Jiaotong University, Chengdu, Sichuan, China
| | - Peng Yang
- Department of Pathology, The Third People's Hospital of Chengdu, The Affiliated Hospital of Southwest Jiaotong University, Chengdu
| | - Jiaojun Li
- Department of Clinical Medicine, North Sichuan Medical College, Fujiang Road, Nanchong
- Department of Gastroenterology
| | - Tai Yu
- Department of Clinical Medicine, North Sichuan Medical College, Fujiang Road, Nanchong
- Department of Gastroenterology
| | - Yi Wang
- Department of Clinical Medicine, North Sichuan Medical College, Fujiang Road, Nanchong
- Department of Gastroenterology
| | - Xi Zhou
- Department of Gastroenterology
| | | | | | | |
Collapse
|
4
|
Park Y, Kang JM, Kim JW, Won DS, Ryu DS, Kim SH, Yun CE, Eo SJ, Park JH, Lee SS. Comparison of Franseen and novel tricore needles for endoscopic ultrasound-guided fine-needle biopsy in a porcine liver model. Sci Rep 2024; 14:22453. [PMID: 39341878 PMCID: PMC11439050 DOI: 10.1038/s41598-024-73184-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Accepted: 09/16/2024] [Indexed: 10/01/2024] Open
Abstract
Endoscopic ultrasound-guided fine needle biopsy is an effective method for obtaining tissue samples from various organs; however, challenges such as inadequate specimens persist. This study compared a newly designed Tricore needle with a Franseen needle for endoscopic ultrasound-guided fine needle biopsy of porcine liver. Both needles were tested on four male Yorkshire pigs. Specimens were obtained with an 100% (36/36) success rate with no procedure-related adverse effects. The Tricore needle experienced significantly less resistance during puncture than Franseen needle (3.83 vs. 5.97 N, P < 0.001) and better ultrasound visibility (168.97 vs. 125.04, P = 0.004). The Tricore needle also achieved faster specimen acquisition time (48.94 vs. 59.90 s, P = 0.038), larger total specimen area (6.67 vs. 4.68 mm2, P = 0.049), fewer fragments (23.94 vs. 31.94, P = 0.190), lager fragment area (0.28 vs. 0.15 mm2, P < 0.001), and more the number of complete portal tracts (15.44 vs. 9.33, P = 0.017) compared to the Franseen needle. The newly designed Tricore needle showed enhanced procedural performance and specimen quantity and quality compared to commercially available Franseen needle. Although further clinical studies are required, the Tricore needle may represent a favorable option for endoscopic ultrasound-guided fine-needle biopsy procedures.
Collapse
Affiliation(s)
- Yubeen Park
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
- Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Jeon Min Kang
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Ji Won Kim
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Dong-Sung Won
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
- Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Dae Sung Ryu
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Song Hee Kim
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
- Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Chae Eun Yun
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Seung Jin Eo
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
- Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea
| | - Jung-Hoon Park
- Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea.
- Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea.
| | - Sang Soo Lee
- Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea.
| |
Collapse
|
5
|
Tiong J, Nguyen P, Sritharan M, Lundy J, Shen H, Kumar B, Swan M, Jenkins B, Croagh D. Evaluation of Needles in Endoscopic Ultrasound-Guided Tissue Acquisition of Pancreatic Cancer for Genetic Yield and Quality. Cureus 2024; 16:e68431. [PMID: 39360054 PMCID: PMC11445693 DOI: 10.7759/cureus.68431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/01/2024] [Indexed: 10/04/2024] Open
Abstract
BACKGROUND Endoscopic ultrasound-guided fine needle biopsy (FNB) is the gold standard in tissue acquisition of pancreatic ductal adenocarcinoma (PDAC). There is a paucity of evidence of the impact of needle type or size on the genetic yield and quality. METHODS Patients 18 years and older with PDAC who underwent FNB were retrospectively identified from a single database from 2016 to 2021. Genetic quantity is measured in micrograms (µg) and quality defined by RNA or DNA integrity number (RIN and DIN). FNB needles examined were Acquire 22 gauge (Boston Scientific, Marlborough, MA, USA) and ProCore 22 and 20 gauges (Cook Medical, Bloomington, IN, USA). RESULTS Two hundred seventy-seven patients were identified. ProCore 20G needle procured higher RNA quantity (4125.8µg, IQR: 2003.8, 5954.8, p = 0.012) compared to ProCore 22G (2050µg IQR: 966.4, 3181.6) and Acquire 22G (2310.6µg, IQR: 1439.3, 4312). Median DNA quantity was 3340.5µg (Acquire 22G), 2610.4µg (ProCore 22G) and 3499.7µg (ProCore 20G) (p = 0.763). Median DIN was 7.3 (Acquire 22G and ProCore 22G) and 7.4 (ProCore 20G) (p = 0.449). Median RIN was 3.0 (Acquire 22G and ProCore 22G) and 2.7 (ProCore 20G) (p = 0.886). CONCLUSION ProCore 20G was associated with higher quantity of RNA. There were no differences in the quality acquired by different needles.
Collapse
Affiliation(s)
| | - Phi Nguyen
- Department of Surgery, Monash Health, Melbourne, AUS
| | | | - Joanne Lundy
- Centre for Innate Immunity and Infectious Diseases, Hudson Institute of Medical Research, Melbourne, AUS
| | - Henry Shen
- Department of Surgery, Monash Health, Melbourne, AUS
| | - Beena Kumar
- Department of Anatomical Pathology, Monash Health, Melbourne, AUS
| | - Michael Swan
- Department of Gastroenterology, Monash Health, Melbourne, AUS
| | - Brendan Jenkins
- Centre for Innate Immunity and Infectious Diseases, Hudson Institute of Medical Research, Melbourne, AUS
| | - Daniel Croagh
- Department of Surgery, Monash Health, Melbourne, AUS
| |
Collapse
|
6
|
Okuno N, Hara K. Endoscopic ultrasound-guided tissue acquisition for comprehensive genomic profiling. J Med Ultrason (2001) 2024; 51:253-260. [PMID: 38281237 DOI: 10.1007/s10396-023-01403-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 11/18/2023] [Indexed: 01/30/2024]
Abstract
Advances in next-generation sequencing have made comprehensive genomic profiling (CGP) using tumor tissue specimens and liquid biopsy using blood samples feasible in routine clinical practice. In the context of pancreaticobiliary cancer, it is necessary to consider CGP in formulating individualized treatment strategies. Performing CGP with tumor tissue specimens requires a sufficient number of high-quality samples. EUS-guided tissue acquisition (EUS-TA) is expected to play a significant role in this regard, and endosonographers need to address this role. Here, we review the current status of EUS-TA for CGP focusing on pancreatic cancer and biliary tract cancer.
Collapse
Affiliation(s)
- Nozomi Okuno
- Department of Gastroenterology, Aichi Cancer Center Hospital, 1-1 Kanokoden, Chikusa-ku, Nagoya, Aichi, 464-8681, Japan.
| | - Kazuo Hara
- Department of Gastroenterology, Aichi Cancer Center Hospital, 1-1 Kanokoden, Chikusa-ku, Nagoya, Aichi, 464-8681, Japan
| |
Collapse
|
7
|
Ishigaki K, Nakai Y, Endo G, Kurihara K, Ishida K, Tange S, Fukuda R, Takaoka S, Tokito Y, Suzuki Y, Oyama H, Kanai S, Suzuki T, Sato T, Hakuta R, Saito T, Hamada T, Takahara N, Shinozaki‐Ushiku A, Fujishiro M. Feasibility of comprehensive genomic profiling using endoscopic ultrasound-guided tissue acquisition with a 22-gauge Franseen needle. DEN OPEN 2024; 4:e365. [PMID: 38628502 PMCID: PMC11019146 DOI: 10.1002/deo2.365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 03/25/2024] [Accepted: 03/31/2024] [Indexed: 04/19/2024]
Abstract
Aim Comprehensive genomic profiling (CGP) test for solid tumors is now increasingly utilized in clinical practice, especially in pancreatobiliary cancer, and specimens obtained by endoscopic ultrasound-guided tissue acquisition (EUS-TA) are often submitted for tissue-based CGP test. In this study, we evaluated the feasibility of EUS-TA using a 22-gauge Franseen needle for the CGP test. Methods Consecutive patients with solid tumors who underwent EUS-TA using a 22-gauge Franseen needle, and whose tissue samples were pre-checked for suitability for CGP test, were included in this single-center, retrospective analysis. The success rates of appropriate sample collection for CGP evaluated by pathologists (1st quality control) and CGP test (2nd quality control) were evaluated. In addition, The EUS-TA slides were evaluated for the tissue area and tumor area content, using the image software. Results A total of 50 cases, with 78% of pancreatic cancer, were included in the analysis. A median of 3 passes of EUS-TA were performed with an adverse event rate of 4%. The success rates for 1st and 2nd quality control for CGP tests were 86% and 76%, respectively. The image analyses suggested EUS-TA specimen did not always fulfill CGP test criteria, with 18% of tissue area ≥16 mm2 and 38% of tumor area content ≥20%, even in cases with successful CGP tests. The suction method yielded a significantly larger amount of DNA but without a significant difference in the multivariate analysis. Conclusions The present study demonstrated the feasibility of EUS-TA using a 22-gauge Franseen needle for CGP test.
Collapse
Affiliation(s)
- Kazunaga Ishigaki
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
- Department of ChemotherapyThe University of Tokyo HospitalTokyoJapan
| | - Yousuke Nakai
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
- Department of Endoscopy and Endoscopic SurgeryThe University of Tokyo HospitalTokyoJapan
| | - Go Endo
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Kohei Kurihara
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Kota Ishida
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Shuichi Tange
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Rintaro Fukuda
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Shinya Takaoka
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Yurie Tokito
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Yukari Suzuki
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Hiroki Oyama
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Sachiko Kanai
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Tatsunori Suzuki
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Tatsuya Sato
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Ryunosuke Hakuta
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Tomotaka Saito
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Tsuyoshi Hamada
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Naminatsu Takahara
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | | | - Mitsuhiro Fujishiro
- Department of GastroenterologyGraduate School of MedicineThe University of TokyoTokyoJapan
| |
Collapse
|
8
|
Yang X, Liu ZM, Zhou X, Yang F, Ma WZ, Sun XZ, Sun SY, Ge N. Methods to increase the diagnostic efficiency of endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions: An updated review. World J Gastrointest Endosc 2024; 16:117-125. [PMID: 38577648 PMCID: PMC10989249 DOI: 10.4253/wjge.v16.i3.117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 12/30/2023] [Accepted: 01/27/2024] [Indexed: 03/14/2024] Open
Abstract
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a means to procure adequate specimens for histological and cytologic analysis. The ideal EUS-FNA should be safe, accurate, and have a high sample adequacy rate and low adverse events rate. In recent years, many guidelines and trials on EUS-FNA have been published. The purpose of this article is to provide an update on the influence of some of the main factors on the diagnostic efficiency of EUS-FNA as well as a rare but serious complication known as needle tract seeding.
Collapse
Affiliation(s)
- Xin Yang
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| | - Zi-Ming Liu
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| | - Xue Zhou
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| | - Fan Yang
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| | - Wen-Zhuang Ma
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| | - Xin-Zhu Sun
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| | - Si-Yu Sun
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| | - Nan Ge
- Department of Gastroenterology, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| |
Collapse
|
9
|
Chatterjee A, Shah J. Role of Endoscopic Ultrasound in Diagnosis of Pancreatic Ductal Adenocarcinoma. Diagnostics (Basel) 2023; 14:78. [PMID: 38201387 PMCID: PMC10802852 DOI: 10.3390/diagnostics14010078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 12/26/2023] [Accepted: 12/27/2023] [Indexed: 01/12/2024] Open
Abstract
Pancreatic ductal adenocarcinoma (PDAC) is the most common (90%) type of solid pancreatic neoplasm. Due to its late presentation and poor survival rate, early diagnosis and timely treatment is of utmost importance for better clinical outcomes. Endoscopic ultrasound provides high-resolution images of the pancreas and has excellent sensitivity in the diagnosis of even small (<2 cm) pancreatic lesions. Apart from imaging, it also has an advantage of tissue acquisition (EUS fine-needle aspiration, FNA; or fine-needle biopsy, FNB) for definitive diagnoses. EUS-guided tissue acquisition plays a crucial role in genomic and molecular studies, which in today's era of personalized medicine, are likely to become important components of PDAC management. With the use of better needle designs and technical advancements, EUS has now become an indispensable tool in the management of PDAC. Lastly, artificial intelligence for the detection of pancreatic lesions and newer automated needles for tissue acquisition will obviate observer dependency in the near future, resulting in the wider dissemination and adoption of this technology for improved outcomes in patients with PDAC.
Collapse
Affiliation(s)
| | - Jimil Shah
- Department of Gastroenterology, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh 160012, India;
| |
Collapse
|
10
|
Wiedbrauck D, Flemming P, Hollerbach S. Role of transduodenal endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/FNB) for diagnosis of retroperitoneal fibrosis (Ormond's disease). ZEITSCHRIFT FUR GASTROENTEROLOGIE 2023; 61:1623-1627. [PMID: 36972595 DOI: 10.1055/a-2003-9752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
Abstract
BACKGROUND Retroperitoneal fibrosis (RPF), often referred to as Ormond's disease when it is of idiopathic origin, is a rare disease characterized by the presence of inflammatory infiltrates and periaortic masses in the retroperitoneum. For a definite diagnosis, a biopsy and subsequent pathological examination is required. Currently accepted methods for retroperitoneal biopsy include open, laparoscopic, or CT-guided approaches. However, transduodenal endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/FNB) for diagnosis of RPF has attracted only little attention in the literature. CASE REPORTS We report two male patient cases who presented with leukocytosis, elevated C-reactive protein, and a suspicious retroperitoneal mass of unknown origin on computed tomography. One patient also reported left lower quadrant pain, whereas the other patient suffered from back pain and weight loss. In both patients, idiopathic RPF was successfully diagnosed by using transduodenal EUS-FNA/FNB with 22- and 20-gauge aspiration needles. Histopathology revealed dense lymphocytic infiltrates and fibrosis. The procedures lasted approximately 25 and 20 minutes, respectively, and in both patients no serious adverse events occurred. Treatment included steroid therapy and administration of Azathioprine. CONCLUSION We demonstrate that using EUS-FNA/FNB to diagnose RPF is a feasible, fast, and safe method, which should always be considered as a first-line diagnostic modality. Hence, this case report emphasizes that gastrointestinal endoscopists are likely to play an important role in the setting of suspected RPF.
Collapse
Affiliation(s)
- Damian Wiedbrauck
- Department of Gastroenterology, Allgemeines Krankenhaus Celle, Celle, Germany
| | | | - Stephan Hollerbach
- Department of Gastroenterology, Allgemeines Krankenhaus Celle, Celle, Germany
| |
Collapse
|
11
|
Yan X, Zhou G, Ji J, Gui Y, Chang X, Zhang J, Lv K, Tan L. Evaluation of the diagnostic efficacy of liquid-based cytology obtained via percutaneous ultrasound-guided fine-needle aspiration for pancreatic masses: a large tertiary center's 8-year experience. J Cancer Res Clin Oncol 2023; 149:17189-17197. [PMID: 37783929 DOI: 10.1007/s00432-023-05438-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 09/18/2023] [Indexed: 10/04/2023]
Abstract
PURPOSE There were limited data on the diagnostic efficacy of liquid-based cytology (LBC) for pancreatic tissues acquired by percutaneous ultrasound-guided fine-needle aspiration (US-FNA). This study aimed to evaluate the diagnostic value of LBC acquired via percutaneous US-FNA for pancreatic tumors compared with LBC combined with smear cytology (SC). METHODS A retrospective database search (January 2014 and February 2022) was performed for patients who underwent percutaneous US-FNA with both LBC and SC. Clinical and pathological data were collected from 298 patients; eventually, 251 cases met the inclusion criteria. Diagnostic accuracy, sensitivity (SEN), specificity (SPE), positive predictive value (PPV) and negative predictive value (NPV) were compared. Rapid on-site evaluation (ROSE) was not available in all cases. RESULTS Based on the pancreaticobiliary cytology guidelines published by the Papanicolaou Society of Cytopathology, 224 (89.2%), 13 (5.2%) and 14 (5.6%) cases were diagnosed as malignant, pre-malignant and benign lesions, respectively. The diagnostic accuracy of the LBC + SC (88.5%) was better than that of LBC (87.3%) but without statistical significance (P = 0.125). The SEN, SPE, PPV and NPV were 87.5%, 85.2%, 98.0% and 45.1%, respectively, in the LBC group and 88.8%, 85.2%, 98.0% and 47.9%, respectively, in the LBC + SC group. According to univariate and multivariate analyses, there were no factors have significant association with the diagnostic sensitivity of LBC. CONCLUSIONS LBC obtained via percutaneous US-FNA provides good diagnostic value for pancreatic lesions and there was no significant difference between the diagnostic accuracy of LBC and LBC + SC when ROSE was unavailable.
Collapse
Affiliation(s)
- Xiaoyi Yan
- Department of Ultrasound, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Guili Zhou
- Department of Ultrasound, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, 518000, China
| | - Jiaqi Ji
- Department of Ultrasound, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Yang Gui
- Department of Ultrasound, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Xiaoyan Chang
- Department of Pathology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Jing Zhang
- Department of Ultrasound, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, 100730, China
| | - Ke Lv
- Department of Ultrasound, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, 100730, China.
| | - Li Tan
- Department of Ultrasound, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, 100730, China.
| |
Collapse
|
12
|
Giri S, Afzalpurkar S, Angadi S, Marikanty A, Sundaram S. Comparison of suction techniques for EUS-guided tissue acquisition: Systematic review and network meta-analysis of randomized controlled trials. Endosc Int Open 2023; 11:E703-E711. [PMID: 37564335 PMCID: PMC10411163 DOI: 10.1055/a-2085-3674] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Accepted: 04/12/2023] [Indexed: 08/12/2023] Open
Abstract
Background and study aims Despite the widespread use of endoscopic ultrasound (EUS)-guided tissue acquisition, the choice of optimal suction technique remains a subject of debate. Multiple studies have shown conflicting results with respect to the four suction techniques: Dry suction (DS), no suction (NS), stylet slow-pull (SSP) and wet suction (WS). Thus, the present network meta-analysis (NMA) was conducted to compare the diagnostic yields of above suction techniques during EUS-guided tissue acquisition. Methods A comprehensive literature search from 2010 to March 2022 was done for randomized trials comparing the aspirated sample and diagnostic outcome with various suction techniques. Both pairwise and network meta-analyses were performed to analyze the outcomes: sample adequacy, moderate to high cellularity, gross bloodiness and diagnostic accuracy. Results A total of 16 studies (n=2048 patients) were included in the final NMA. WS was associated with a lower odd of gross bloodiness compared to DS (odds ratio 0.50, 95% confidence interval 0.24-0.97). There was no significant difference between the various suction methods with respect to sample adequacy, moderate to high cellularity and diagnostic accuracy. On meta-regression, to adjust for the effect of needle type, WS was comparable to DS in terms of bloodiness when adjusted for fine-needle aspiration needle. Surface under the cumulative ranking analysis ranked WS as the best modality for all the outcomes. Conclusions The present NMA did not show superiority of any specific suction technique for EUS-guided tissue sampling with regard to sample quality or diagnostic accuracy, with low confidence in estimates.
Collapse
Affiliation(s)
- Suprabhat Giri
- Gastroenterology, Nizam's Institute of Medical Sciences, Hyderabad, India
| | | | - Sumaswi Angadi
- Gastroenterology, Nizam's Institute of Medical Sciences, Hyderabad, India
| | - Adarsh Marikanty
- General Medicine, Nizam's Institute of Medical Sciences, Hyderabad, India
| | - Sridhar Sundaram
- Department of Digestive Diseases and Clinical Nutrition, Tata Memorial Hospital, Mumbai, India
| |
Collapse
|
13
|
Jun JC, Lee SH, Lee HM, Kim SG, Chung H, Kim JS, Park N, Choi JH, Kwak Y, Cho SJ. A prospective randomized noninferiority trial comparing conventional smears and SurePathTM liquid-based cytology in endoscopic ultrasound-guided sampling of esophageal, gastric, and duodenal lesions. Medicine (Baltimore) 2023; 102:e34321. [PMID: 37478273 PMCID: PMC10662805 DOI: 10.1097/md.0000000000034321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 06/22/2023] [Indexed: 07/23/2023] Open
Abstract
BACKGROUND Several liquid-based cytology (LBC) methods are currently used, but the diagnostic accuracy of each method is not well known. We aimed to compare the diagnostic performance of SurePathTM LBC and conventional smear (CS) cytology in endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) samples of esophageal, gastric, and duodenal lesions. METHODS As a prospective randomized noninferiority study, patients who needed EUS-FNA due to subepithelial mass in the upper gastrointestinal tract were randomly assigned 1:1 to the LBC and CS groups. Cytologic preparation was carried out using a crossover design where 1 method was used for the first needle-pass sample and another method was used for the second needle-pass sample. The primary outcome was to compare the diagnostic performance between LBC and CS using the final diagnosis as the gold standard. RESULTS A total of 87 patients were randomized and 60 patients were analyzed. There were no differences between LBC and CS in diagnostic accuracy (91.7% vs 86.7%, P = .380), sensitivity (97.7% vs 90.7%, P = .169), specificity (76.5% vs 76.5%, P > .99), negative predictive value (92.9% vs 76.5%, P = .225), or positive predictive value (91.3% vs 90.7%, P = .921). The background of LBC was less bloody than that of CSs (5.0% vs 53.3%, P < .001) and the sample preparation time of LBC was shorter than that of CSs (29 ± 7 seconds vs 90 ± 17 seconds, P < .001). CONCLUSION In the EUS-FNA of a subepithelial mass in the upper gastrointestinal tract, the diagnostic performance of LBC was not inferior to that of CS. The field of view was better in LBC, because the background was less bloody and necrotic. As LBC is more convenient to perform and takes shorter time, it is expected that it can replace the CS method for EUS-FNA samples.
Collapse
Affiliation(s)
- Jae Chang Jun
- Department of Internal Medicine, Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Sang Hyub Lee
- Department of Internal Medicine, Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Han Myung Lee
- Department of Internal Medicine, Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Sang Gyun Kim
- Department of Internal Medicine, Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Hyunsoo Chung
- Department of Internal Medicine, Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Joo Seong Kim
- Department of Internal Medicine, Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Namyoung Park
- Department of Internal Medicine, Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Jin Ho Choi
- Department of Internal Medicine, Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Yoonjin Kwak
- Department of Pathology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Soo-Jeong Cho
- Department of Internal Medicine, Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
14
|
Omairi TW, Micelli-Neto O, Taglieri E, de Araujo-Filho JC, de Faria ATR, Goldman SM, Surjan RCT, Machado MA, Venco FE, Ardengh JC. Endoscopic Ultrasound-Guided Tissue Acquisition Versus Fine Needle Aspiration for Diagnosis of Pancreatic Ductal Adenocarcinoma. Cureus 2023; 15:e41576. [PMID: 37554612 PMCID: PMC10406500 DOI: 10.7759/cureus.41576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/03/2023] [Indexed: 08/10/2023] Open
Abstract
OBJECTIVES Compare the 22G needle versus EchoTip ProCore® 20 (Cook Medical, Bloomington, IN, USA) on their handling, specimen suitability, amount of tissue obtained, diagnostic performance, the possibility of immunohistochemistry, and rate of adverse events. MATERIALS AND METHODS This is a retrospective, comparative study of consecutively examined patients with pancreatic masses who underwent endosonography-guided fine needle aspiration (FNA) via the 22G needle, and endosonography-guided tissue acquisition (TA) via ProCore 20 (PC20). The operator evaluated needle insertion and subjectively classified the specimen. The pathologist measured the samples, classified the amount of tissue, and determined the influence of bleeding on the interpretation. RESULTS A total of 129 patients participated in the study, out of whom 52 underwent endosonography-guided FNA with 22G and 77 underwent endosonography-guided TA with a PC20 needle. Malignant lesions were found in 106, and 23 had benign lesions. The duodenal route was used in 62% of patients. The 22G needle was easier to introduce (p=0.0495). However, PC20 obtained a larger amount (p<0.01) with fewer punctures (p<0.001). The PC20 also yielded a larger average microcore diameter (p=0.0032). Microhistology was adequate for 22G and PC20 in 22 (42.2%) and 50 (78.1%) specimens, respectively (p<0.001). Bleeding was not significantly different (p>0.999). Immunohistochemistry was possible in 36 (69.2%) and 40 (51.9%) specimens obtained by 22G and PC20, respectively (p=0.075). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 22G were 93.5%, 100%, 100%, 66.7%, and 94.2%, respectively; and for PC20, it was 95%, 100%, 100%, 85%, and 96.1%, respectively. Mild bleeding was the most common early adverse event, occurring in 2/52 (3.8%) 22G and 4/77 (5.2%) PC20 cases (p>0.05). CONCLUSIONS The PC20 required fewer punctures and reduced the need for immunohistochemistry as it yielded better and larger microcores. Its ease of insertion into the target lesion makes it a good option to obtain satisfactory microcore specimens in difficult positions, such as the transduodenal route.
Collapse
Affiliation(s)
| | | | - Eloy Taglieri
- Endoscopy, Hospital A.C. Camargo Center, São Paulo, BRA
| | | | | | - Suzan M Goldman
- Imaging Diagnostics, Universidade Federal de São Paulo (UNIFESP), São Paulo, BRA
| | - Rodrigo Cañada T Surjan
- Surgery, Faculdade de Medicina da Universidade de São Paulo, São Paulo, BRA
- Surgery, Hospital Nove de Julho, São Paulo, BRA
| | - Marcel A Machado
- Gastrointestinal Surgery, Hospital Nove de Julho, São Paulo, BRA
| | | | | |
Collapse
|
15
|
Liu Y, Xiong D, Zhao Y, Meng Z, Wu X, Jiang Q, Wang Q, Wu D, Zhang S, Feng Y, Yang A. Endoscopic ultrasound-guided tissue acquisition with or without rapid on-site evaluation for solid pancreatic lesions: five years of experience from a single center. Scand J Gastroenterol 2023; 58:1185-1193. [PMID: 37114616 DOI: 10.1080/00365521.2023.2204985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Accepted: 04/16/2023] [Indexed: 04/29/2023]
Abstract
BACKGROUND Endoscopic ultrasound (EUS)-guided tissue acquisition (TA) by EUS-guided fine needle aspiration (FNA) or fine needle biopsy (FNB) is a standard diagnostic procedure for solid pancreatic lesions. Whether rapid on-site evaluation (ROSE) should be used to support EUS-TA remains controversial. Here we assessed the diagnostic performance of EUS-TA with or without self-ROSE for solid pancreatic masses. METHODS Three hundred and seventy EUS-TA cases with self-ROSE and 244 cases without ROSE were retrospectively enrolled between August 2018 and June 2022. All procedures including ROSE were performed by the attending endoscopist. Clinical data, EUS characteristics, and diagnostic performance for distinguishing benign from malignant solid pancreatic masses including accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were compared between groups. RESULTS Self-ROSE improved the diagnostic accuracy of solid pancreatic lesions by 16.7% in the EUS-TA group (p < 0.001) and by 18.9% in the EUS-FNA alone group (p < 0.001). Self-ROSE also improved the diagnostic sensitivity by 18.6% in the EUS-TA group (p < 0.001) and by 21.2% in the EUS-FNA alone group (p < 0.001). Improvements in the diagnostic accuracy by self-ROSE in the EUS-FNB group were not significant. 2.2 ± 0.7, 2.4 ± 0.9, 2.3 ± 0.7, 2.5 ± 0.9, 2.1 ± 0.6, and 2.1 ± 0.7 needle passes were required in the EUS-TA, EUS-FNA, and EUS-FNB with or without self-ROSE groups, respectively. CONCLUSIONS Self-ROSE significantly improved the accuracy and sensitivity of EUS-FNA alone and EUS-TA diagnosis of solid pancreatic lesions and helped to reduce needle passes during the procedure. Whether self-ROSE benefits EUS-FNB and whether EUS-FNB alone is comparable to EUS-FNA with self-ROSE require further clarification.
Collapse
Affiliation(s)
- Yongru Liu
- Department of Gastroenterology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
| | - Dingkun Xiong
- Department of Gastroenterology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
| | - Yu Zhao
- Department of Pathology, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
| | - Zhilan Meng
- Department of Pathology, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
| | - Xi Wu
- Department of Gastroenterology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
| | - Qingwei Jiang
- Department of Gastroenterology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
| | - Qiang Wang
- Department of Gastroenterology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
| | - Dongsheng Wu
- Department of Gastroenterology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
| | - Shengyu Zhang
- Department of Gastroenterology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
| | - Yunlu Feng
- Department of Gastroenterology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
| | - Aiming Yang
- Department of Gastroenterology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China
| |
Collapse
|
16
|
Masuda S, Koizumi K, Shionoya K, Jinushi R, Makazu M, Nishino T, Kimura K, Sumida C, Kubota J, Ichita C, Sasaki A, Kobayashi M, Kako M, Haruki U. Comprehensive review on endoscopic ultrasound-guided tissue acquisition techniques for solid pancreatic tumor. World J Gastroenterol 2023; 29:1863-1874. [PMID: 37032729 PMCID: PMC10080698 DOI: 10.3748/wjg.v29.i12.1863] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 02/02/2023] [Accepted: 03/16/2023] [Indexed: 03/28/2023] Open
Abstract
Pancreatic ductal adenocarcinoma is speculated to become the second leading cause of cancer-related mortality by 2030, a high mortality rate considering the number of cases. Surgery and chemotherapy are the main treatment options, but they are burdensome for patients. A clear histological diagnosis is needed to determine a treatment plan, and endoscopic ultrasound (EUS)-guided tissue acquisition (TA) is a suitable technique that does not worsen the cancer-specific prognosis even for lesions at risk of needle tract seeding. With the development of personalized medicine and precision treatment, there has been an increasing demand to increase cell counts and collect specimens while preserving tissue structure, leading to the development of the fine-needle biopsy (FNB) needle. EUS-FNB is rapidly replacing EUS-guided fine-needle aspiration (FNA) as the procedure of choice for EUS-TA of pancreatic cancer. However, EUS-FNA is sometimes necessary where the FNB needle cannot penetrate small hard lesions, so it is important clinicians are familiar with both. Given these recent dev-elopments, we present an up-to-date review of the role of EUS-TA in pancreatic cancer. Particularly, technical aspects, such as needle caliber, negative pressure, and puncture methods, for obtaining an adequate specimen in EUS-TA are discussed.
Collapse
Affiliation(s)
- Sakue Masuda
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Kazuya Koizumi
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Kento Shionoya
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Ryuhei Jinushi
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Makomo Makazu
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Takashi Nishino
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Karen Kimura
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Chihiro Sumida
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Jun Kubota
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Chikamasa Ichita
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Akiko Sasaki
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Masahiro Kobayashi
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Makoto Kako
- Department of Gastroenterology, Shonan Kamakura General Hospital, Kanagawa 247-8533, Japan
| | - Uojima Haruki
- Department of Gastroenterology, Internal Medicine, Kitasato University School of Medicine, Kanagawa 252-0375, Japan
| |
Collapse
|
17
|
Comparison between Target Sample Check Illuminator and White Light Observation in Discriminating the Presence of Target Specimen for Endoscopic Ultrasound-Guided Fine Needle Aspiration Sample. J Clin Med 2023; 12:jcm12062139. [PMID: 36983143 PMCID: PMC10051683 DOI: 10.3390/jcm12062139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/05/2023] [Accepted: 03/07/2023] [Indexed: 03/11/2023] Open
Abstract
Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is an essential endoscopic tissue sampling method for diagnosing pancreatobiliary diseases; however, determining the presence of target specimens mixed in the blood by conventional observation is challenging due to the small size of the obtained sample. This study investigated the usefulness of a target sample check illuminator (TSCI) that emits a specific wavelength of light to determine the presence of target specimens. Twenty-seven patients who underwent EUS-FNA at our hospital were included. Conventional white light observation was performed for the collected samples, followed by TSCI; six people evaluated the presence of the target specimen on a 5-point scale. The target specimen discrimination score using TSCI (median: 5) was significantly higher than that using conventional white light observation (median: 1) (p < 0.001). No significant difference was observed in the discrimination score between the evaluator (novice vs. expert, p = 0.162) and puncture needle (22G vs. 25G, p = 0.196). The discriminability of TSCI in the samples obtained using EUS-FNA was significantly higher than that of conventional observation. TSCI does not depend on the evaluator or puncture needle for the identification of the target specimen; hence, it can provide a good pathological specimen and may contribute to the improvement of the diagnostic ability.
Collapse
|
18
|
Matsunami Y, Itoi T, Tsuchiya T, Ishii K, Tanaka R, Tonozuka R, Mukai S, Nagai K, Yamamoto K, Asai Y, Kurosawa T, Kojima H, Minami H, Homma T, Joyama E, Sofuni A. Objective evaluation of the resistance forces of 22-gauge EUS-FNA and fine-needle biopsy needles. Endosc Ultrasound 2023; 12:251-258. [PMID: 37148137 PMCID: PMC10237597 DOI: 10.4103/eus-d-22-00059] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 11/06/2022] [Indexed: 05/07/2023] Open
Abstract
Background and Objectives EUS-guided tissue acquisition is routinely performed for the diagnosis of gastrointestinal tract and adjacent organ lesions. Recently, various types of needles have been developed. However, how the shape of the needle tip and echoendoscope tip angle affect puncturability, has not been clarified. The aim of this experimental study was to compare the puncturability of several 22-gauge EUS-FNA and EUS-guided fine-needle biopsy (EUS-FNB) needles, and to evaluate the effects of the needle tip shape and echoendoscope tip angle on tissue puncturability. Materials and Methods The following six major FNA and FNB needles were evaluated: SonoTip® ProControl, EZ Shot 3 Plus, Expect™ Standard Handle, SonoTip® TopGain, Acquire™, and SharkCore™. The mean maximum resistance force against needle advancement was evaluated and compared under several conditions using an echoendoscope. Results The mean maximum resistance force of the needle alone was higher for the FNB needles than for the FNA needles. The mean maximum resistance force of the needle in the echoendoscope with free angle demonstrated that the resistance forces were between 2.10 and 2.34 Newton (N). The mean maximum resistance force increased upon increases in angle of the tip of echoendoscope, particularly in the FNA needles. Among the FNB needles, SharkCore™ had the lowest resistance force (2.23 N). The mean maximum resistance force of the needle alone, the needle in the echoendoscope with free angle, and the needle in the echoendoscope with full-up angle for SonoTip® TopGain were all similar to that of Acquire™. Conclusion SonoTip® TopGain had similar puncturability to Acquire™ in all tested situations. Regarding the puncturability, SharkCore™ is most suitable for insertion into target lesions, when tight echoendoscope tip angle is necessary.
Collapse
Affiliation(s)
- Yukitoshi Matsunami
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Takao Itoi
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Takayoshi Tsuchiya
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Kentaro Ishii
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Reina Tanaka
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Ryosuke Tonozuka
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Shuntaro Mukai
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Kazumasa Nagai
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Kenjiro Yamamoto
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Yasutsugu Asai
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Takashi Kurosawa
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Hiroyuki Kojima
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Hirohito Minami
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Toshihiro Homma
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| | - Eri Joyama
- Department of International Medical Care, Tokyo Medical University, Tokyo, Japan
| | - Atsushi Sofuni
- Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan
| |
Collapse
|
19
|
Takeshita K, Hijioka S, Nagashio Y, Maruki Y, Kawasaki Y, Maehara K, Murashima Y, Okada M, Ikeda G, Yamada N, Takasaki T, Agarie D, Hara H, Hagiwara Y, Okamoto K, Yamashige D, Ohba A, Kondo S, Morizane C, Ueno H, Saito Y, Ohe Y, Okusaka T. Diagnostic Ability of Endoscopic Ultrasound-Guided Tissue Acquisition Using 19-Gauge Fine-Needle Biopsy Needle for Abdominal Lesions. Diagnostics (Basel) 2023; 13:diagnostics13030450. [PMID: 36766558 PMCID: PMC9914510 DOI: 10.3390/diagnostics13030450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 01/20/2023] [Accepted: 01/23/2023] [Indexed: 01/28/2023] Open
Abstract
Attempts at performing endoscopic ultrasound-guided tissue acquisition (EUS-TA) with a 19G needle are increasing because histological diagnosis and comprehensive genomic profiling are a necessity. However, the diagnostic ability of the 19G fine-needle biopsy (FNB) needle, especially the third-generation FNB needle, is unclear and has been retrospectively reviewed. The 19G TopGain needle was used in 147 patients and 160 lesions between September 2020 and December 2021. The technical success rate of the biopsies was 99.4% (159/160). The early adverse event rate was 4.1% (6/147), and moderate or severe adverse event rate occurrence was 2.0% (3/147). The sensitivity, specificity, and accuracy of the 19G TopGain needle for 157 lesions with a confirmed diagnosis were 96.7%, 100%, and 96.8%, respectively. Rescue EUS-TA using the 19G TopGain needle was performed for nine lesions, and a successful diagnosis was made in six of these lesions (66.7%). The diagnostic ability of EUS-TA using the third-generation 19G TopGain needle was favorable. However, the use of 19G FNB needles may increase adverse events. Therefore, EUS-TA with a 19G FNB needle is mainly indicated in lesions where comprehensive genomic profiling may be necessary or the diagnosis could not be determined via EUS-TA using the 22G needle.
Collapse
Affiliation(s)
- Kotaro Takeshita
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
- Cancer Medicine, Jikei University Graduate School of Medicine, Tokyo 105-0003, Japan
| | - Susumu Hijioka
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
- Correspondence: ; Tel.: +81-3-3542-2511
| | - Yoshikuni Nagashio
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Yuta Maruki
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Yuki Kawasaki
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Kosuke Maehara
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Yumi Murashima
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Mao Okada
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Go Ikeda
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Natsumi Yamada
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Tetsuro Takasaki
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Daiki Agarie
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Hidenobu Hara
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Yuya Hagiwara
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Kohei Okamoto
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Daiki Yamashige
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Akihiro Ohba
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Shunsuke Kondo
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Chigusa Morizane
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Hideki Ueno
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Yutaka Saito
- Endoscopy Division, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Yuichiro Ohe
- Cancer Medicine, Jikei University Graduate School of Medicine, Tokyo 105-0003, Japan
- Department of Thoracic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| | - Takuji Okusaka
- Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo 104-0045, Japan
| |
Collapse
|
20
|
Afzalpurkar S, Rai VK, Sonthalia N, Rodge G, Tewary A, Goenka M. Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration with Fine-Needle Biopsy for Solid Gastrointestinal Lesions: A Randomized Crossover Single-Center study. JOURNAL OF DIGESTIVE ENDOSCOPY 2023. [DOI: 10.1055/s-0042-1760276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
Abstract
Background/Aims The purpose of this study was to compare the results of endoscopic ultrasound guided fine-needle aspiration (EUS-FNA) and fine-needle biopsy (FNB) performed at the same site in a single session in the same patient.
Methods Consecutive patients with solid gastrointestinal lesions referred for EUS evaluation underwent EUS-FNA and FNB using 22G needles with three and two passes, respectively, in the same session. Patients were randomized to one group having EUS-FNA first followed by EUS-FNB, while other group had EUS-FNB first followed by EUS-FNA.
Results Total 50 patients (31 male) of mean age 56.58 ± 14.2 years and mean lesion size of 2.6 (±2) cm were included. The Kappa agreement for final diagnosis for FNA and FNB was 0.841 and 0.61, respectively. The sensitivity and specificity of FNA versus FNB were 85.19 versus 62.96% and 100 versus 100%, respectively, in comparison with final diagnosis.
Conclusion Both EUS-FNA and FNB are equally safe when compared between the two techniques simultaneously in same lesion. EUS-FNA is better than FNB in terms of sensitivity, diagnostic accuracy, and tissue yield for solid GI lesion. However, the specificity and positive predictive value were equally good for both the modalities.
Collapse
Affiliation(s)
- Shivaraj Afzalpurkar
- Institute of Gastrosciences and Liver, Apollo Hospital, Kolkata, West Bengal, India
| | - Vijay Kumar Rai
- Institute of Gastrosciences and Liver, Apollo Hospital, Kolkata, West Bengal, India
| | - Nikhil Sonthalia
- Institute of Gastrosciences and Liver, Apollo Hospital, Kolkata, West Bengal, India
| | - Gajanan Rodge
- Institute of Gastrosciences and Liver, Apollo Hospital, Kolkata, West Bengal, India
| | - Awanesh Tewary
- Institute of Gastrosciences and Liver, Apollo Hospital, Kolkata, West Bengal, India
| | - Mahesh Goenka
- Institute of Gastrosciences and Liver, Apollo Hospital, Kolkata, West Bengal, India
| |
Collapse
|
21
|
Sheng LP, Lin R, Tao X, Guo XW, Han CQ, Nie C, Zhang K, Ding Z. Actual pressure generated by various suction technique and suctioning liquid weight through endoscopic ultrasound-guided aspiration needles. J Dig Dis 2022; 23:713-719. [PMID: 36636867 DOI: 10.1111/1751-2980.13153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Revised: 10/06/2022] [Accepted: 01/10/2023] [Indexed: 01/14/2023]
Abstract
OBJECTIVES Suction pressure is one of the most important factors influencing the amount of tissue obtained during endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/FNB). In this study we aimed to elucidate actual suction pressure generated by various suction methods and the weight of suctioning liquid. METHODS Different types of fine needles and suction techniques were used, including the slow pull technique (SPT), dry suction technique (DST), wet suction technique (WST), neutralizing negative pressure technique (NNPT), and residual negative pressure technique (RNPT). Actual suction pressure was measured and the amount of suctioning liquid was weighed. RESULTS Actual suction pressure and weight of the suctioning liquid were lower using SPT than using DST, while they were higher when using WST compared with those using DST. In general, the actual suction pressure increased and the weight of suctioning liquid decreased as the diameter of the FNA needles decreased. While weight of the suctioning liquid using FNB needles was significantly larger than that using FNA needles. In general, the actual suction pressure generated using RNPT was larger than that using NNPT. CONCLUSIONS WST is superior to SPT and DST in terms of actual suction pressure and weight of suctioning liquid. Diameter of the FNA needle was an important factor that may affect the actual suction pressure and weight of suctioning liquid. FNB needles are superior to FNA needles when it comes to the weight of suctioning liquid. Actual suction pressure obtained by novel suction methods (NNPT and RNPT) may provide a basis for future research.
Collapse
Affiliation(s)
- Li Ping Sheng
- Department of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China
- Department of Gastroenterology, The First Affiliated Hospital of Xiamen University, Xiamen, Fujian Province, China
| | - Rong Lin
- Department of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China
| | - Xu Tao
- Department of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China
| | - Xian Wen Guo
- Department of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China
| | - Chao Qun Han
- Department of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China
| | - Chi Nie
- Department of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China
| | - Kun Zhang
- Department of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China
| | - Zhen Ding
- Department of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China
- Department of Gastroenterology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China
| |
Collapse
|
22
|
Karstensen JG, Vilmann P. Historical perspective on needle development: From the past to the future. Best Pract Res Clin Gastroenterol 2022; 60-61:101814. [PMID: 36577533 DOI: 10.1016/j.bpg.2022.101814] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 11/11/2022] [Accepted: 11/22/2022] [Indexed: 11/27/2022]
Abstract
With the introduction of EUS, endoscopy was no longer limited to luminal indications. However, the method was unable to distinguish malignant from benign lesions. Consequently, needles designed for tissue acquisition under EUS-guidance was designed. Initially, the needles were designed for fine needle aspiration (FNA); nevertheless, with increased requirement for the precured tissue in terms of quality and quantity, newly design needles aimed at obtaining tissue cores for histological assessment were developed. Recent studies demonstrate superiority of these fine needle biopsy needles (FNB) compared to FNA needles.
Collapse
Affiliation(s)
- John Gásdal Karstensen
- Pancreatitis Centre East, Gastro Unit, Copenhagen University Hospital - Amager and Hvidovre, Copenhagen, Denmark; Dept of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
| | - Peter Vilmann
- Dept of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark; Gastro Unit, Division of Endoscopy, Copenhagen University Hospital - Herlev and Gentofte Hospital, Herlev, Denmark.
| |
Collapse
|
23
|
Endoscopic ultrasound-guided tissue acquisition for splenic lesions: A systematic review and meta-analysis of diagnostic test accuracy. PLoS One 2022; 17:e0276529. [PMID: 36264978 PMCID: PMC9584539 DOI: 10.1371/journal.pone.0276529] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 10/10/2022] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND AND AIMS At present, it is difficult and risky to diagnose splenic lesions by conventional needle biopsy using computed tomography (CT) or ultrasound (US). Endoscopic ultrasound (EUS)-guided tissue acquisition is increasingly being used as a new technique to determine the tissue diagnosis of splenic lesions. Therefore, our goal was to determine the efficacy and safety of EUS-guided tissue acquisition for splenic lesions. METHODS We performed a systematic review and meta-analysis to evaluate the pooled sensitivity and specificity of EUS-guided tissue acquisition for the diagnosis of splenic lesions using Metadisc. The Quality Assessment of Diagnostic Accuracy Studies Questionnaire, a quality assessment tool, was used to scrutinize the quality of the studies. RESULTS Six eligible studies between January 2000 and June 2022 were identified, and a total number of 62 patients (aged range from 19 to 84) were enrolled. One patient was excluded because of insufficient specimens. The pooled sensitivity and specificity of included studies were 0.85 [95% confidence interval (CI), 0.73-0.93] and 0.77 (95% CI, 0.46-0.95), respectively. The pooled positive likelihood ratio (LR) was 2.38 (95% CI, 1.24-4.57), the pooled negative LR was 0.31 (95% CI, 0.17-0.55), the pooled diagnostic odds ratio (DOR) was 8.67 (95% CI, 2.80-26.82), the area under the summary receiver operating characteristic (SROC) curve was 0.8100 (Standard Error 0.0813). CONCLUSION EUS-guided tissue acquisition is a safe technique with high sensitivity in the diagnosis of splenic lesions. However, because of the small sample sizes, more studies with more cases are needed to further validate these results.
Collapse
|
24
|
Zhang S, Ni M, Wang P, Zheng J, Sun Q, Xu G, Peng C, Shen S, Zhang W, Huang S, Wang L, Zou X, Lv Y. Diagnostic value of endoscopic ultrasound-guided fine needle aspiration with rapid on-site evaluation performed by endoscopists in solid pancreatic lesions: A prospective, randomized controlled trial. J Gastroenterol Hepatol 2022; 37:1975-1982. [PMID: 35614028 DOI: 10.1111/jgh.15897] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 03/18/2022] [Accepted: 05/14/2022] [Indexed: 12/19/2022]
Abstract
BACKGROUND AND AIM Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the most established diagnostic method for pancreatic tissue. Rapid on-site evaluation by a trained endoscopist (self-ROSE) can improve the diagnostic accuracy. This research is aimed to analyze the application value of self-ROSE for EUS-FNA in solid pancreatic lesions. METHODS A total of 194 consecutive patients with solid pancreatic lesions in Nanjing Drum Tower Hospital were randomized in a 1:1 ratio to EUS-FNA with or without self-ROSE in this single-center randomized controlled trial. Before initiating self-ROSE, the endoscopist underwent training for pancreatic cytologic sample adequacy assessment and cytopathological diagnosis of EUS-FNA in pathology department for 1 month. Some parts of the slides of EUS-FNA were air dried, stained on-site with BASO Liu's reagent, and on-site evaluated in self-ROSE group. Between the two groups, the diagnostic performance of EUS-FNA was analyzed, including sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, with a comparison of the number of needle passes and the complication rates. RESULTS The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were 94.8%, 94.4%, 100%, 100%, and 58.3% in the self-ROSE group, respectively, and 70.1%, 65.1%, 100%, 100%, and 32.6% in the non-self-ROSE group. The diagnostic accuracy (P < 0.001) and sensitivity (P < 0.001) were both significantly increased during EUS-FNA in the self-ROSE group compared to the non-self-ROSE group. The rate of cytologic sample adequacy was 100% in self-ROSE group and 80.4% in non-self-ROSE group. The number of passes were 3.38 ± 1.00 in self-ROSE group and 3.22 ± 0.89 in non-self-ROSE group (P = 0.228). No complications were found in both. There was acceptable consistency between endoscopist and pathologist in the cytopathological diagnosis (kappa = 0.666, P < 0.05) and in the sample adequacy rate (kappa = 1.000, P < 0.001). CONCLUSION Our results demonstrated that self-ROSE is valuable for EUS-FNA in the diagnosis of solid pancreatic lesions and is an important choice to routinely increase the accuracy of EUS-FNA in centers without ROSE assessment.
Collapse
Affiliation(s)
- Song Zhang
- Department of Gastroenterology, Nanjing Drum Tower Hospital, Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, China.,Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Muhan Ni
- Department of Gastroenterology, Nanjing Drum Tower Hospital, Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, China.,Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Pin Wang
- Department of Gastroenterology, Nanjing Drum Tower Hospital, Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, China.,Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Jinyu Zheng
- Department of Pathology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Qi Sun
- Department of Pathology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Guifang Xu
- Department of Gastroenterology, Nanjing Drum Tower Hospital, Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, China.,Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Chunyan Peng
- Department of Gastroenterology, Nanjing Drum Tower Hospital, Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, China.,Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Shanshan Shen
- Department of Gastroenterology, Nanjing Drum Tower Hospital, Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, China.,Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Wei Zhang
- Department of Gastroenterology, Nanjing Drum Tower Hospital, Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, China.,Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Shuling Huang
- Department of Gastroenterology, Nanjing Drum Tower Hospital, Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, China.,Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Lei Wang
- Department of Gastroenterology, Nanjing Drum Tower Hospital, Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, China.,Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Xiaoping Zou
- Department of Gastroenterology, Nanjing Drum Tower Hospital, Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, China.,Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| | - Ying Lv
- Department of Gastroenterology, Nanjing Drum Tower Hospital, Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, China.,Department of Gastroenterology, Nanjing Drum Tower Hospital, Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing, China
| |
Collapse
|
25
|
Itonaga M, Yasukawa S, Fukutake N, Ogura T, Asada M, Shimokawa T, Inatomi O, Nakai Y, Shiomi H, Nebiki H, Suzuki A, Kitagawa K, Asai S, Shimatani M, Sanuki T, Kurita A, Takenaka M, Yoshida M, Hoki N, Yasuda H, Maruyama H, Matsumoto H, Yanagisawa A, Kitano M. Comparison of 22-gauge standard and Franseen needles in EUS-guided tissue acquisition for diagnosing solid pancreatic lesions: a multicenter randomized controlled trial. Gastrointest Endosc 2022; 96:57-66.e2. [PMID: 35151711 DOI: 10.1016/j.gie.2022.02.005] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Accepted: 02/01/2022] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS This large multicenter randomized controlled trial compared the diagnostic yields of 22-gauge standard and 22-gauge Franseen needles for EUS-guided tissue acquisition (EUS-TA) of solid pancreatic lesions. METHODS Consecutive patients with solid pancreatic lesions were prospectively randomized to EUS-TA using standard or Franseen needles. Samples obtained with the first needle pass and with second and subsequent passes were evaluated separately. The primary endpoint was the rate of accuracy for diagnosis of malignancy. Other endpoints were technical success rate, sample cellularity, adverse events, diagnostic accuracy in patient subgroups, and the diagnostic accuracy and numbers of second and subsequent needle passes. RESULTS Of 523 patients undergoing EUS-TA, 260 were randomized to using standard 22-gauge needles and 263 to 22-gauge Franseen needles. The technical success rate in each group was 99.6%, with similar adverse event rates in the standard (1.5%) and Franseen (.8%) needle groups. First-pass EUS-TA using the Franseen needle resulted in significantly greater diagnostic accuracy (84.0% vs 71.2%, P < .001) and sensitivity (82.4% vs 66.7%, P < .001) than first-pass EUS-TA using a standard needle and also resulted in superior diagnostic accuracy in patients requiring immunostaining. Second and subsequent EUS-TA using Franseen needles showed significantly greater accuracy (94.7% vs 90.0%, P = .049) and sensitivity (94.0% vs 88.6%, P = .047) and required fewer needle passes (1.81 vs 2.03, P = .008) than using standard needles. CONCLUSIONS EUS-TA with the Franseen needle is superior to EUS-TA with a standard needle with respect to diagnostic accuracy per pass, particularly in patients who require immunostaining, and number of passes when using macroscopic on-site evaluation. (Clinical trial registration numbers: UMIN000030634 and jRCTs052180062.).
Collapse
Affiliation(s)
- Masahiro Itonaga
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Satoru Yasukawa
- Department of Pathology, Kyoto Second Red Cross Hospital, Kyoto, Japan Department of Surgical Pathology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Nobuyasu Fukutake
- Department of Gastrointestinal Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Takeshi Ogura
- The Second Department of Internal Medicine, Osaka Medical College, Takatsuki, Japan
| | - Masanori Asada
- Department of Gastroenterology and Hepatology, Japanese Red Cross Osaka Hospital, Osaka, Japan
| | - Toshio Shimokawa
- Clinical Study Support Center, Wakayama Medical University, Wakayama, Japan
| | - Osamu Inatomi
- Division of Gastroenterology, Department of Medicine, Shiga University of Medical Science, Shiga, Japan
| | - Yoshitaka Nakai
- Digestive Disease Center, Department of Gastroenterology & Hepatology, Kyoto Katsura Hospital, Kyoto, Japan
| | - Hideyuki Shiomi
- Division of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Hiroko Nebiki
- Department of Gastroenterology, Osaka City General Hospital, Osaka, Japan
| | - Azumi Suzuki
- Department of Gastroenterology, Kyoto Second Red Cross Hospital, Kyoto, Japan
| | - Koh Kitagawa
- Department of Gastroenterology, Nara Medical University, Nara, Japan
| | - Satoshi Asai
- Department of Gastroenterology, Tane General Hospital, Osaka, Japan
| | - Masaaki Shimatani
- Division of Gastroenterology and Hepatology, The Third Department of Internal Medicine, Kansai Medical University, Osaka, Japan
| | - Tsuyoshi Sanuki
- Department of Gastroenterology, Kita-harima Medical Center, Hyogo, Japan
| | - Akira Kurita
- Department of Gastroenterology and Hepatology, Kitano Hospital, Tazuke Kofukai Medical Research Institute, Osaka, Japan
| | - Mamoru Takenaka
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Motoyuki Yoshida
- Department of Gastroenterology, Nara Prefecture Western Medical Center, Nara, Japan
| | - Noriyuki Hoki
- Department of Gastroenterology, Bellland General Hospital, Sakai, Japan
| | - Hiroaki Yasuda
- Department of Medicine, Division of Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Hirotsugu Maruyama
- Department of Gastroenterology, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - Hisakazu Matsumoto
- Department of Gastroenterology and Hepatology, Japanese Red Cross Society of Wakayama Medical Center, Wakayama, Japan
| | - Akio Yanagisawa
- Department of Pathology, Japanese Red Cross Society Kyoto Daiichi Hospital, Kyoto, Japan Department of Surgical Pathology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| |
Collapse
|
26
|
The Utility of Endoscopic-Ultrasonography-Guided Tissue Acquisition for Solid Pancreatic Lesions. Diagnostics (Basel) 2022; 12:diagnostics12030753. [PMID: 35328306 PMCID: PMC8947755 DOI: 10.3390/diagnostics12030753] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Revised: 03/13/2022] [Accepted: 03/17/2022] [Indexed: 02/07/2023] Open
Abstract
Endoscopic-ultrasonography-guided tissue acquisition (EUS-TA) has been widely performed for the definitive diagnosis of solid pancreatic lesions (SPLs). As the puncture needles, puncture techniques, and sample processing methods have improved, EUS-TA has shown higher diagnostic yields and safety. Recently, several therapeutic target genomic biomarkers have been clarified in pancreatic ductal carcinoma (PDAC). Although only a small proportion of patients with PDAC can benefit from precision medicine based on gene mutations at present, precision medicine will also be further developed for SPLs as more therapeutic target genomic biomarkers are identified. Advances in next-generation sequencing (NGS) techniques enable the examination of multiple genetic mutations in limited tissue samples. EUS-TA is also useful for NGS and will play a more important role in determining treatment strategies. In this review, we describe the utility of EUS-TA for SPLs.
Collapse
|
27
|
Kanno A, Miwata T, Nagai H, Ikeda E, Ando K, Kawasaki Y, Tada Y, Yokoyama K, Tamada K, Fukushima N, Kawarai Lefor A, Yamamoto H. Endoscopic ultrasound-guided pancreatic sampling for the histopathological diagnosis of autoimmune pancreatitis. Dig Endosc 2022; 34:420-427. [PMID: 34233051 DOI: 10.1111/den.14076] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 06/21/2021] [Accepted: 07/06/2021] [Indexed: 12/25/2022]
Abstract
Autoimmune pancreatitis (AIP), which is characterized by pancreatic enlargement and irregular narrowing of the main pancreatic duct, is difficult to differentiate from malignancy. The irregular narrowing of the pancreatic duct, which can be detected via endoscopic retrograde cholangiopancreatography, is a characteristic feature of AIP; however, distinguishing between localized AIP and pancreatic cancer based on pancreatic duct imaging is difficult. This study overviews the efficacy of endoscopic ultrasound (EUS)-guided pancreatic sampling for the histopathological diagnosis of AIP. Recent enhancements in needle biopsy methodologies and technologies have contributed to improvement in the diagnostic efficacy of this technique. The guidance provided in this study for the histological diagnosis of AIP is anticipated to further advance in the histopathological diagnosis of AIP using EUS-guided pancreatic sampling.
Collapse
Affiliation(s)
- Atsushi Kanno
- Department of, Medicine, Division of Gastroenterology, Jichi Medical University, Tochigi, Japan
| | - Tetsurou Miwata
- Department of, Medicine, Division of Gastroenterology, Jichi Medical University, Tochigi, Japan
| | - Hiroki Nagai
- Department of, Medicine, Division of Gastroenterology, Jichi Medical University, Tochigi, Japan
| | - Eriko Ikeda
- Department of, Medicine, Division of Gastroenterology, Jichi Medical University, Tochigi, Japan.,Pathology, Jichi Medical University, Tochigi, Japan
| | - Kozue Ando
- Department of, Medicine, Division of Gastroenterology, Jichi Medical University, Tochigi, Japan.,Pathology, Jichi Medical University, Tochigi, Japan
| | - Yuki Kawasaki
- Department of, Medicine, Division of Gastroenterology, Jichi Medical University, Tochigi, Japan
| | - Yamato Tada
- Department of, Medicine, Division of Gastroenterology, Jichi Medical University, Tochigi, Japan
| | - Kensuke Yokoyama
- Department of, Medicine, Division of Gastroenterology, Jichi Medical University, Tochigi, Japan
| | - Kiichi Tamada
- Department of, Medicine, Division of Gastroenterology, Jichi Medical University, Tochigi, Japan
| | | | | | - Hironori Yamamoto
- Department of, Medicine, Division of Gastroenterology, Jichi Medical University, Tochigi, Japan
| |
Collapse
|
28
|
Zhu NX, Wang XY, Tong T, Xu JH, Yang YY, Tian L. Primary pancreatic lymphoma diagnosed by endoscopic ultrasound-guided fine needle biopsy. Hepatobiliary Pancreat Dis Int 2022; 21:99-102. [PMID: 34108082 DOI: 10.1016/j.hbpd.2021.05.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 05/18/2021] [Indexed: 02/05/2023]
Affiliation(s)
- Ning-Xin Zhu
- Gastroenterology Department of the Third Xiangya Hospital, Central South University, Changsha 410013, China
| | - Xiao-Yan Wang
- Gastroenterology Department of the Third Xiangya Hospital, Central South University, Changsha 410013, China
| | - Ting Tong
- Gastroenterology Department of the Third Xiangya Hospital, Central South University, Changsha 410013, China
| | - Jia-Hao Xu
- Gastroenterology Department of the Third Xiangya Hospital, Central South University, Changsha 410013, China
| | - Yuan-Yuan Yang
- Gastroenterology Department of the Third Xiangya Hospital, Central South University, Changsha 410013, China
| | - Li Tian
- Gastroenterology Department of the Third Xiangya Hospital, Central South University, Changsha 410013, China.
| |
Collapse
|
29
|
Li C, Mi J, Gao F, Zhu X, Su M, Xie X, Zhao D. Comparison of Endoscopic Ultrasound-Guided Fine Needle Aspiration with 19-Gauge and 22-Gauge Needles for Solid Pancreatic Lesions. Int J Gen Med 2021; 14:10439-10446. [PMID: 35002300 PMCID: PMC8722532 DOI: 10.2147/ijgm.s342525] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 12/14/2021] [Indexed: 11/23/2022] Open
Affiliation(s)
- Changjuan Li
- Department of Gastroenterology, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei Province, People’s Republic of China
- Department of Gastroenterology, The First Hospital of Handan City, Handan, 056002, Hebei Province, People’s Republic of China
| | - Jianwei Mi
- Department of Gastroenterology, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei Province, People’s Republic of China
| | - Fulai Gao
- Department of Gastroenterology, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei Province, People’s Republic of China
| | - Xinying Zhu
- Department of Gastroenterology, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei Province, People’s Republic of China
| | - Miao Su
- Department of Gastroenterology, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei Province, People’s Republic of China
| | - Xiaoli Xie
- Department of Gastroenterology, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei Province, People’s Republic of China
| | - Dongqiang Zhao
- Department of Gastroenterology, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, Hebei Province, People’s Republic of China
- Correspondence: Dongqiang Zhao Department of Gastroenterology, The Second Hospital of Hebei Medical University, No. 215, He ping West Road, Xinhua District, Shijiazhuang, Hebei Province, 050000, People’s Republic of ChinaTel +86 0311 66636179 Email
| |
Collapse
|
30
|
Yoon SB, Moon SH, Song TJ, Kim JH, Kim MH. Endoscopic ultrasound-guided fine needle aspiration versus biopsy for diagnosis of autoimmune pancreatitis: Systematic review and comparative meta-analysis. Dig Endosc 2021; 33:1024-1033. [PMID: 33030283 DOI: 10.1111/den.13866] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 10/01/2020] [Indexed: 12/17/2022]
Abstract
BACKGROUND Endoscopic ultrasound (EUS) is recommended for guiding the acquisition of pancreatic tissue in patients with suspected autoimmune pancreatitis (AIP). Data comparing EUS-guided fine needle aspiration (FNA) and fine needle biopsy (FNB) sampling in the diagnosis of AIP are limited. METHODS A comprehensive literature search of the PubMed, EMBASE, and Ovid MEDLINE databases was conducted until April 2020. The pooled rates of diagnostic yield for the histologic criteria of AIP, histologic tissue procurement, and adverse events were compared between FNA and FNB. Diagnostic yields were also compared between 19 gauge (G) and 22G needles. RESULTS This meta-analysis included nine studies comprising 309 patients with AIP who underwent FNA and seven studies comprising 131 patients who underwent FNB. The pooled diagnostic yields for level 1 or 2 histology criteria of AIP were 55.8% (95% confidence interval (CI) 37.0-73.9%, I2 = 91.1) for FNA and 87.2% (95% CI 68.8-98.1%, I2 = 69.4) for FNB (P = 0.030). The pooled histologic procurement rates for FNA and FNB were 91.3% (95% CI, 84.9-97.6%, I2 = 82.9) and 87.0% (95% CI, 77.8-96.1%, I2 = 40.0), respectively (P = 0.501). Adverse events were comparable between two groups. When analyzed by needle size, the diagnostic yield was better with a 19G needle than with a 22G needle (88.9% vs. 60.6%, P = 0.023). CONCLUSIONS The diagnostic yield may be better with FNB needles than with FNA needles for the diagnosis of AIP, despite the similar rate of histologic tissue procurement. A quantitative definition for the histologic sample adequacy for AIP may be warranted.
Collapse
Affiliation(s)
- Seung Bae Yoon
- Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Sung-Hoon Moon
- Department of Internal Medicine, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, South Korea.,Institute for Liver and Digestive Diseases, Hallym University, Chuncheon, South Korea
| | - Tae Jun Song
- Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| | - Jong Hyeok Kim
- Department of Internal Medicine, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, South Korea.,Institute for Liver and Digestive Diseases, Hallym University, Chuncheon, South Korea
| | - Myung-Hwan Kim
- Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
| |
Collapse
|
31
|
Kanno A, Tamada K, Fukushima N, Lefor AK, Yamamoto H. Endoscopic ultrasound-guided tissue acquisition for the histopathological diagnosis of autoimmune pancreatitis. J Med Ultrason (2001) 2021; 48:555-563. [PMID: 34669069 DOI: 10.1007/s10396-021-01144-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Accepted: 07/28/2021] [Indexed: 01/22/2023]
Abstract
Autoimmune pancreatitis (AIP) is a disease concept that originated in Japan. It is characterized by diffuse pancreatic enlargement and irregular narrowing of the main pancreatic duct. Although the usefulness of the histological diagnosis of AIP using endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) and EUS-guided fine-needle biopsy (FNB) has been reported, enhanced diagnostic performance is expected with improvements in tissue collection methods and fine-needle techniques. Guidance for establishing the tissue diagnosis of AIP has been developed and is useful for histological evaluation. Histopathological diagnosis by EUS-FNA/FNB is expected to play a central role in AIP diagnosis in the future.
Collapse
Affiliation(s)
- Atsushi Kanno
- Division of Gastroenterology, Department of Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| | - Kiichi Tamada
- Division of Gastroenterology, Department of Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan
| | | | | | - Hironori Yamamoto
- Division of Gastroenterology, Department of Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan
| |
Collapse
|
32
|
Ishigaki K, Nakai Y, Oyama H, Kanai S, Suzuki T, Nakamura T, Sato T, Hakuta R, Saito K, Saito T, Takahara N, Hamada T, Mizuno S, Kogure H, Tada M, Isayama H, Koike K. Endoscopic Ultrasound-Guided Tissue Acquisition by 22-Gauge Franseen and Standard Needles for Solid Pancreatic Lesions. Gut Liver 2021; 14:817-825. [PMID: 32457276 PMCID: PMC7667934 DOI: 10.5009/gnl19171] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 08/12/2019] [Accepted: 08/13/2019] [Indexed: 12/13/2022] Open
Abstract
Background/Aims Recently, a three-plane symmetric needle with Franseen geometry was developed for endoscopic ultrasound-guided fine needle biopsy (EUS-FNB). In this retrospective study, tissue acquisition per pass was compared between 22-gauge Franseen FNB and standard fine needle aspiration (FNA) needles in patients with solid pancreatic lesions. Methods Consecutive patients who underwent EUS-FNA or EUS-FNB for solid pancreatic lesions between October 2014 and March 2018 were retrospectively studied. The tissue acquisition rate and the diagnostic performance per session, per pass, and at first pass were compared. Results A total of 663 passes (300 by the FNB needle and 363 by the standard FNA needle) were performed in 154 patients (71 FNB and 83 FNA). The tissue acquisition rate per session and at first pass in the FNB and FNA groups was 100% and 95% (p=0.13) and 87% and 69% (p=0.007), respectively. The multivariate analysis revealed that among the patients, EUS-FNB (odds ratio, 3.07; p=0.01) was associated with a higher first-pass tissue acquisition rate. While the tissue acquisition rate reached a plateau after the 4th pass with FNA, it reached a plateau after the 2nd pass with FNB. Among the 129 malignant cases, the histological tissue acquisition rate per session was similar (100% and 94%), but the sensitivity by histology alone per session was higher for FNB than for FNA (93% and 73%, p<0.01). Conclusions The results of our retrospective analysis indicated that compared with a standard FNA needle, a 22-gauge Franseen FNB needle was associated with a higher first-pass tissue acquisition rate.
Collapse
Affiliation(s)
- Kazunaga Ishigaki
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Yousuke Nakai
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan.,Department of Endoscopy and Endoscopic Surgery, Graduate School of Medicine, The University of Tokyo, Japan
| | - Hiroki Oyama
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Sachiko Kanai
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Tatsunori Suzuki
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Tomoka Nakamura
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Tatsuya Sato
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Ryunosuke Hakuta
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Kei Saito
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Tomotaka Saito
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Naminatsu Takahara
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Tsuyoshi Hamada
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Suguru Mizuno
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Hirofumi Kogure
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Minoru Tada
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| | - Hiroyuki Isayama
- Department of Gastroenterology, Graduate School of Medicine, Juntendo University, Tokyo, Japan
| | - Kazuhiko Koike
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Japan
| |
Collapse
|
33
|
Ginès A, Fusaroli P, Sendino O, Seicean A, Gimeno-Garcia AZ, Gratacós-Ginès J, Araujo IK, Rodríguez-Carunchio L, Alós S, Lisotti A, Cominardi A, Montenegro A, Fernández-Esparrach G. Performance of a new flexible 19 G EUS needle in pancreatic solid lesions located in the head and uncinate process: A prospective multicenter study. Endosc Int Open 2021; 9:E1269-E1275. [PMID: 34447875 PMCID: PMC8383085 DOI: 10.1055/a-1480-0428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Accepted: 03/22/2021] [Indexed: 12/30/2022] Open
Abstract
Background and study aims The poor flexibility of large-bore EUS needles often leads to technical failure when sampling from the duodenum. The aim of this study was to evaluate the technical and diagnostic performances of a new Menghini tip 19G nitinol EUS needle for sampling pancreatic solid lesions in the head and uncinate process. Patients and methods This was a European prospective multicenter single-arm study. A maximum of four passes were allowed. In case of failure, different needles were permitted. Results We included 75 patients (51 % males) with lesions in the head (n = 68; 91 %) and uncinate process (n = 7; 9 %) (mean size: 33 ± 12 mm; number of passes: 1.8 ± 0.9). Technical success was seen in 71 of 75 (94.7 %). Diagnostic rates were 89.3 % (67/75) and 94.4 % (67/71) in the intention-to-treat (ITT) and per-protocol (PP) analysis, respectively. In the eight cases with failure, diagnosis was obtained with another needle (n = 4), from another lesion (n = 3) or with follow-up (n = 1). A histological sample was obtained in 64 patients (ITT 85.3 % and PP 90 %) and immunohistochemistry was successfully performed in 13 of 15 lesions in which it was required. No differences between rapid on-site evaluation (ROSE) and non-ROSE groups were observed regarding diagnostic success (87.5 % vs 91 %, P = 0.582) and diagnosis at the first pass (70 % vs 81 %, P = 0.289). Number of passes was lower in the ROSE group (1.4 + 0.9 vs 2.2 + 0.7, P < 0.001). One adverse event was recorded (1.3 %) consisting in a duodenal perforation after a single session EUS-ERCP. Conclusions The new nitinol Menghini tip 19G EUS needle showed high technical diagnostic success in safely sampling solid lesions in the head and uncinate process of the pancreas.
Collapse
Affiliation(s)
- Angels Ginès
- Hospital Clinic de Barcelona – Endoscopy Unit, Barcelona. University of Barcelona, Spain,CIBEREHD Barcelona, Spain,IDIBAPS – Medicina, Barcelona, Spain
| | - Pietro Fusaroli
- Hospital of Imola – GI Unit, University of Bologna, Imola, Italy
| | - Oriol Sendino
- Hospital Clinic de Barcelona – Endoscopy Unit, Barcelona. University of Barcelona, Spain,CIBEREHD Barcelona, Spain,IDIBAPS – Medicina, Barcelona, Spain
| | - Andrada Seicean
- University of Medicine and Pharmacy – Regional Institute of Gastroenterology and Hepatology, Cluj-Napoca, Romania
| | - Antonio Z. Gimeno-Garcia
- Hospital Universitario de de Sta Cruz de Tenerife – Service of Gastroenterology, Tenerife, Spain
| | - Jordi Gratacós-Ginès
- Hospital Clinic de Barcelona – Endoscopy Unit, Barcelona. University of Barcelona, Spain
| | - Isis K. Araujo
- Hospital Clinic de Barcelona – Endoscopy Unit, Barcelona. University of Barcelona, Spain,IDIBAPS – Medicina, Barcelona, Spain
| | - Leonardo Rodríguez-Carunchio
- Hospital Clinic de Barcelona – Pathology Department, University of Vic – Central University of Catalonia (UVic-UCC), Barcelona, Spain
| | - Silvia Alós
- Hospital Clinic de Barcelona – Pathology Department, University of Vic – Central University of Catalonia (UVic-UCC), Barcelona, Spain
| | - Andrea Lisotti
- Hospital of Imola – GI Unit, University of Bologna, Imola, Italy
| | - Anna Cominardi
- Hospital of Imola – GI Unit, University of Bologna, Imola, Italy
| | - Andrea Montenegro
- Hospital Clinic de Barcelona – Endoscopy Unit, Barcelona. University of Barcelona, Spain
| | - Glòria Fernández-Esparrach
- Hospital Clinic de Barcelona – Endoscopy Unit, Barcelona. University of Barcelona, Spain,CIBEREHD Barcelona, Spain,IDIBAPS – Medicina, Barcelona, Spain
| |
Collapse
|
34
|
Han S, Bhullar F, Alaber O, Kamal A, Hopson P, Kanthasamy K, Coughlin S, Archibugi L, Thiruvengadam N, Moreau C, Jin D, Paragomi P, Valverde-López F, Nagpal S, Yazici C, Papachristou G, Lee PJ, Akshintala V. Comparative diagnostic accuracy of EUS needles in solid pancreatic masses: a network meta-analysis. Endosc Int Open 2021; 9:E853-E862. [PMID: 34079867 PMCID: PMC8159621 DOI: 10.1055/a-1381-7301] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Accepted: 01/11/2021] [Indexed: 11/04/2022] Open
Abstract
Background and study aims Endoscopic ultrasound (EUS)-guided tissue sampling is the standard of care for diagnosing solid pancreatic lesions. While many two-way comparisons between needle types have been made in randomized controlled trials (RCTs), it is unclear which size and type of needle offers the best probability of diagnosis. We therefore performed a network meta-analysis (NMA) to compare different sized and shaped needles to rank the diagnostic performance of each needle. Methods We searched MEDLINE, EMBASE and Cochrane Library databases through August, 2020 for RCTs that compared the diagnostic accuracy of EUS fine-needle aspiration (FNA) and biopsy (FNB) needles in solid pancreatic masses. Using a random-effects NMA under the frequentist framework, RCTs were analyzed to identify the best needle type and sampling technique. Performance scores (P-scores) were used to rank the different needles based on pooled diagnostic accuracy. The NMA model was used to calculate pairwise relative risk (RR) with 95 % confidence intervals. Results Review of 2577 studies yielded 29 RCTs for quantitative synthesis, comparing 13 different needle types. All 22G FNB needles had an RR > 1 compared to the reference 22G FNA (Cook) needle. The highest P-scores were seen with the 22G Medtronic FNB needle (0.9279), followed by the 22G Olympus FNB needle (0.8962) and the 22G Boston Scientific FNB needle (0.8739). Diagnostic accuracy was not significantly different between needles with or without suction. Conclusions In comparison to FNA needles, FNB needles offer the highest diagnostic performance in sampling pancreatic masses, particularly with 22G FNB needles.
Collapse
Affiliation(s)
- Samuel Han
- Division of Gastroenterology, Hepatology, and Nutrition, The Ohio State University Wexner Medical Center, Columbus, OH
| | - Furqan Bhullar
- Division of Gastroenterology and Hepatology, Johns Hopkins University, Baltimore, Maryland, United States
| | - Omar Alaber
- Division of Gastroenterology and Liver Disease, University Hospitals, Cleveland, Ohio, United States
| | - Ayesha Kamal
- Division of Gastroenterology and Hepatology, Johns Hopkins University, Baltimore, Maryland, United States
| | - Puanani Hopson
- Division of Pediatric Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, United States
| | - Kavin Kanthasamy
- Division of Gastroenterology and Hepatology, Johns Hopkins University, Baltimore, Maryland, United States
| | - Sarah Coughlin
- Division of Gastroenterology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, United States
| | - Livia Archibugi
- Faculty of Medicine and Psychology, Sapienza University of Rome, Rome, Italy
| | - Nikhil Thiruvengadam
- Division of Gastroenterology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, United States
| | - Christopher Moreau
- Division of Gastroenterology, University of Texas Health San Antonio, San Antonio, Texas, United States
| | - David Jin
- Division of Gastroenterology, Hepatology, and Endoscopy, Brigham and Women’s Hospital, Boston, Massachusetts, United States
| | - Pedram Paragomi
- Division of Gastroenterology, Hepatology, and Nutrition, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | | | - Sajan Nagpal
- Division of Gastroenterology, Hepatology, and Nutrition. University of Chicago, Chicago, Illinois, United States
| | - Cemal Yazici
- Division of Gastroenterology and Hepatology, University of Illinois at Chicago, Chicago, Illinois, United States
| | - Georgios Papachristou
- Division of Gastroenterology, Hepatology, and Nutrition, The Ohio State University Wexner Medical Center, Columbus, OH
| | - Peter J Lee
- Division of Gastroenterology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, United States
| | - Venkata Akshintala
- Division of Gastroenterology and Hepatology, Johns Hopkins University, Baltimore, Maryland, United States
| | | |
Collapse
|
35
|
Marques S, Bispo M, Rio-Tinto R, Fidalgo P, Devière J. The Impact of Recent Advances in Endoscopic Ultrasound-Guided Tissue Acquisition on the Management of Pancreatic Cancer. GE-PORTUGUESE JOURNAL OF GASTROENTEROLOGY 2021; 28:185-192. [PMID: 34056041 DOI: 10.1159/000510730] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 08/05/2020] [Indexed: 12/17/2022]
Abstract
Over the last few decades, endoscopic ultrasound (EUS)-guided tissue acquisition has become the method of choice for the pathological diagnosis of solid pancreatic lesions. Due to its high diagnostic yield and low complication rate, EUS-guided tissue acquisition has surpassed percutaneous sampling techniques. For many years, EUS-guided fine-needle aspiration (EUS-FNA) was traditionally used to obtain cytological aspirates of solid pancreatic lesions, with sensitivity values ranging from 80 to 90% for the diagnosis of malignancy. Nevertheless, despite numerous technical advances, EUS-FNA still presents some limitations. Therefore, EUS-guided fine-needle biopsy (EUS-FNB) has been introduced to provide tissue core biopsies, allowing histological assessment. A newly developed generation of FNB needles has demonstrated an outstanding diagnostic accuracy of over 95% for solid pancreatic lesions and provides samples appropriate for ancillary testing, such as immunohistochemistry and tumour molecular profiling. As a result, EUS-FNB is rapidly replacing EUS-FNA and is now the recommended technique for EUS-guided tissue acquisition in pancreatic cancer. Furthermore, with the recent expansion of neoadjuvant treatment criteria and with the advent of novel and personalised anti-cancer therapies, EUS-FNB is gaining a pivotal role in pancreatic cancer management and might soon be generalised to all patients, independent of disease stage. In this article, the authors present an updated review of the role of EUS-guided tissue acquisition in pancreatic cancer. Current indications, several technical aspects and new applications of EUS-FNA and EUS-FNB are discussed.
Collapse
Affiliation(s)
- Susana Marques
- Department of Gastroenterology and Digestive Endoscopy, Champalimaud Foundation, Lisbon, Portugal
| | - Miguel Bispo
- Department of Gastroenterology and Digestive Endoscopy, Champalimaud Foundation, Lisbon, Portugal
| | - Ricardo Rio-Tinto
- Department of Gastroenterology and Digestive Endoscopy, Champalimaud Foundation, Lisbon, Portugal
| | - Paulo Fidalgo
- Department of Gastroenterology and Digestive Endoscopy, Champalimaud Foundation, Lisbon, Portugal
| | - Jacques Devière
- Department of Gastroenterology and Digestive Endoscopy, Champalimaud Foundation, Lisbon, Portugal.,Department of Gastroenterology, Hepatopancreatology, and Digestive Oncology, Erasme University Hospital - Université Libre de Bruxelles, Brussels, Belgium
| |
Collapse
|
36
|
Del Vecchio Blanco G, Palmieri G, Giannarelli D, Formica V, Portarena I, Nardecchia A, Troncone E, Benassi M, Giudice E, Anselmo A, Tisone G, Roselli M, Monteleone G, Paoluzi OA. Factors influencing diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic and biliary tumors. Scand J Gastroenterol 2021; 56:498-504. [PMID: 33539716 DOI: 10.1080/00365521.2021.1880628] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND AND AIM Diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is influenced by several factors, primarily operator expertise. Formal training in EUS-FNA, as suggested by the European Society of Gastrointestinal Endoscopy and the American Society for Gastrointestinal Endoscopy guidelines, is not always available and is often expensive and time-consuming. In this study we evaluate factors influencing the diagnostic accuracy of pancreatic EUS-FNA. METHODS In a retrospective study, 557 consecutive EUS-FNAs were evaluated. Several variables relating to the procedures were considered to calculate the EUS-FNA performance over eight years. RESULTS A total of 308 out of 557 EUS-FNAs were selected. Overall sensitivity of EUS-FNA was 66% (95% CI: 60.8-71.8), specificity 100%, and diagnostic accuracy 69% (95% CI: 64.0-74.4). An increase in diagnostic accuracy was observed to >90% using a new fine-needle biopsy (FNB) needle and in the case of simultaneous sampling of primary and metastatic lesions. Diagnostic accuracy >80% was observed after 250 procedures, in the absence of rapid on-site cytopathological examination (ROSE). Multivariate logistic regression analysis confirmed that the FNB needle, operator skill, and double EUS-FNA sampling are associated with high diagnostic accuracy. CONCLUSIONS The learning curve for EUS-FNA may be longer and a considerable number of procedures are needed to achieve high diagnostic accuracy in the absence of ROSE. However, the use of FNB needles and the simultaneous sampling of primary and metastatic lesions can rapidly improve the diagnostic accuracy of the procedure.
Collapse
Affiliation(s)
| | - Giampiero Palmieri
- Anatomic Pathology Unit, Department of Biomedicine and Prevention, University of Rome Tor Vergata, Rome, Italy
| | - Diana Giannarelli
- Biostatistical Unit, Regina Elena Institute-Hospital Physiotherapy Institutes, Rome, Italy
| | | | | | | | - Edoardo Troncone
- Gastroenterology Unit, Department of Systems Medicine, University of Rome Tor Vergata, Rome, Italy
| | - Michela Benassi
- Radiotherapy Unit, Department of Oncohematology, University of Rome Tor Vergata, Rome, Italy
| | - Emilia Giudice
- Radiotherapy Unit, Department of Oncohematology, University of Rome Tor Vergata, Rome, Italy
| | - Alessandro Anselmo
- Transplant Surgery Unit, Department of Surgery, University of Rome Tor Vergata, Rome, Italy
| | - Giuseppe Tisone
- Transplant Surgery Unit, Department of Surgery, University of Rome Tor Vergata, Rome, Italy
| | - Mario Roselli
- Oncology Unit, University of Rome Tor Vergata, Rome, Italy
| | - Giovanni Monteleone
- Gastroenterology Unit, Department of Systems Medicine, University of Rome Tor Vergata, Rome, Italy
| | - Omero Alessandro Paoluzi
- Gastroenterology Unit, Department of Systems Medicine, University of Rome Tor Vergata, Rome, Italy
| |
Collapse
|
37
|
Kanata R, Sasaki T, Matsuyama M, Ishigaki K, Yamada I, Ozaka M, Takano K, Takazawa Y, Ishizuka N, Sasahira N. Prospective study of EUS-guided tissue acquisition with a 20G core biopsy needle with a forward bevel for solid pancreatic mass. Medicine (Baltimore) 2021; 100:e24193. [PMID: 33466194 PMCID: PMC7808531 DOI: 10.1097/md.0000000000024193] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Accepted: 12/11/2020] [Indexed: 01/05/2023] Open
Abstract
There is a growing need for tissue collection for immunostaining and genetic testing. Recently, several fine-needle biopsy needles are commercially available for endoscopic ultrasound-guided tissue acquisition.This prospective historical controlled study evaluates a 20G core biopsy needle with a forward bevel for solid pancreatic masses larger than 15 mm in diameter. The primary endpoint was the accuracy of histological diagnosis. The secondary endpoints included technical success rate, sample adequacy for histology, cytological diagnostic accuracy, and adverse events.Seventy consecutive patients were enrolled between January and October 2017. We achieved technical success in all cases regardless of the puncture sites or the endosonographer's experience. The final diagnoses were neoplasms in 67 patients (95.7%; pancreatic cancer in 65 patients, neuroendocrine neoplasm in 1, and malignant lymphoma in 1) and benign lesions in 3 patients (4.3%; autoimmune pancreatitis in 2 patients and mass-forming pancreatitis in 1). The obtained specimens were adequate for histological evaluation in all cases and the histological accuracy was 91.4% (95% confidence interval, 82.3-96.8%, P < .05) with the sensitivity and specificity of 91.0% and 100%, respectively. The cytological diagnostic accuracy was 95.7% and all patients were accurately diagnosed by combining cytological and histological examinations. As for adverse events, an asymptomatic needle fracture occurred in 1 case (1.4%).This 20G core biopsy needle with a forward bevel showed a high accuracy of histological diagnosis for solid pancreatic masses.
Collapse
Affiliation(s)
- Ryo Kanata
- Department of Hepato-Biliary-Pancreatic Medicine
| | | | | | | | | | - Masato Ozaka
- Department of Hepato-Biliary-Pancreatic Medicine
| | | | | | - Naoki Ishizuka
- Department of Clinical Trial Planning and Management, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| | | |
Collapse
|
38
|
Watanabe S, Miyoshi J, Toki M, Kambayashi K, Kitada S, Nosaka T, Goto T, Ota H, Ochiai K, Gondo K, Ikeuchi N, Tsuji S, Nakamura K, Shibahara J, Hisamatsu T. Effectiveness of introducing a 20-gauge core biopsy needle with a core trap in EUS-FNA/B for diagnosing pancreatic cancer. BMC Gastroenterol 2021; 21:8. [PMID: 33407181 PMCID: PMC7789690 DOI: 10.1186/s12876-020-01583-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 12/15/2020] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/B) is a standard method for pathological diagnosis of pancreatic solid lesions. The EchoTip ProCore 20G® (PC20), a 20-gauge biopsy needle with a forward-bevel core trap, has been available in Japan since 2015. METHODS We compared the efficacy of the PC20 with that of the EchoTip ProCore 22G® (PC22) and Acquire 22G® (AC22) in EUS-FNA/B for diagnosing pancreatic cancer. This retrospective study included 191 patients with pancreatic cancer who underwent EUS-FNA/B using the PC20, PC22, or AC22 at our facility from April 2013 to October 2019. We investigated the patients' clinical characteristics and the diagnostic accuracy and safety of each needle. RESULTS A sufficient stroke length of puncture was secured in all patients. The maximum length under EUS was shorter with the AC22 (22.1 ± 2.2 mm) than PC20 (30.6 ± 0.7 mm, p < 0.01) and PC22 (30.3 ± 0.8 mm, p < 0.01). The histological accuracy was 96.4% with the PC20 but only 58.8% with the PC22 (adjusted p (p-adj) < 0.0001) and 75.0% with the AC22 (p-adj = 0.06). The diagnostic accuracy of the combination of histology and cytology was 96.4% with the PC20, while it was 72.1% with the PC22 (p-adj < 0.0001) and 91.7% with the AC22 (p-adj > 0.99). One patient (0.9%) in the PC20 group developed mild pancreatitis, but no adverse events occurred with the other needles. CONCLUSIONS The PC20 showed better diagnostic capability than the PC22. The diagnostic efficacy was similar between the PC20 and AC22. The high histological accuracy of the PC20 could be advantageous for lesions in which histological assessment is critical.
Collapse
Affiliation(s)
- Shunsuke Watanabe
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Jun Miyoshi
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan.
| | - Masao Toki
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Komei Kambayashi
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Shuichi Kitada
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Takeshi Nosaka
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Tomoyuki Goto
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Hirotaka Ota
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Kazushige Ochiai
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Koichi Gondo
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Nobuhito Ikeuchi
- Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Shujiro Tsuji
- Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Kenji Nakamura
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
- Department of Gastroenterology and Hepatology, Tokyo Dental College Ichikawa General Hospital, 5-11-13 Sugano, Ichikawa-shi, Chiba, 272-8513, Japan
| | - Junji Shibahara
- Department of Pathology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan
| | - Tadakazu Hisamatsu
- Department of Gastroenterology and Hepatology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka-shi, Tokyo, 181-8611, Japan.
| |
Collapse
|
39
|
Kanno A, Ikeda E, Ando K, Nagai H, Miwata T, Kawasaki Y, Tada Y, Yokoyama K, Numao N, Ushio J, Tamada K, Lefor AK, Yamamoto H. The Diagnosis of Autoimmune Pancreatitis Using Endoscopic Ultrasonography. Diagnostics (Basel) 2020; 10:diagnostics10121005. [PMID: 33255660 PMCID: PMC7760882 DOI: 10.3390/diagnostics10121005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 11/18/2020] [Accepted: 11/20/2020] [Indexed: 12/14/2022] Open
Abstract
Autoimmune pancreatitis (AIP) is characterized by enlargement of the pancreas and irregular narrowing of the main pancreatic duct. It is often associated with IgG4-related sclerosing cholangitis (IgG4-SC), in which the bile duct narrows. Although characteristic irregular narrowing of the pancreatic duct caused by endoscopic retrograde cholangiopancreatography is noted in AIP, it is difficult to differentiate between localized AIP and pancreatic carcinoma based on imaging of the pancreatic duct. While stenosis of the bile duct in IgG4-SC is characterized by longer-length stenosis than in cholangiocarcinoma, differentiation based on bile duct imaging alone is challenging. Endoscopic ultrasound (EUS) can characterize hypoechoic enlargement of the pancreas or bile duct wall thickening in AIP and IgG4-SC, and diagnosis using elastography and contrast-enhanced EUS are being evaluated. The utility of EUS-guided fine needle aspiration for the histological diagnosis of AIP has been reported and is expected to improve diagnostic performance for AIP. Findings in the bile duct wall from endoscopic retrograde cholangiopancreatography followed by intraductal ultrasonography are useful in differentiating IgG4-SC from cholangiocarcinoma. Diagnoses based on endoscopic ultrasonography play a central role in the diagnosis of AIP.
Collapse
Affiliation(s)
- Atsushi Kanno
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
- Correspondence: ; Tel.: +81-285-58-7348; Fax: 81-285-44-8297
| | - Eriko Ikeda
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
| | - Kozue Ando
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
| | - Hiroki Nagai
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
| | - Tetsuro Miwata
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
| | - Yuki Kawasaki
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
| | - Yamato Tada
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
| | - Kensuke Yokoyama
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
| | - Norikatsu Numao
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
| | - Jun Ushio
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
| | - Kiichi Tamada
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
| | - Alan Kawarai Lefor
- Department of Surgery, Jichi Medical University, Shimotsuke 329-0498, Japan;
| | - Hironori Yamamoto
- Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke 329-0498, Japan; (E.I.); (K.A.); (H.N.); (T.M.); (Y.K.); (Y.T.); (K.Y.); (N.N.); (J.U.); (K.T.); (H.Y.)
| |
Collapse
|
40
|
Mizuide M, Ryozawa S, Fujita A, Ogawa T, Katsuda H, Suzuki M, Noguchi T, Tanisaka Y. Complications of Endoscopic Ultrasound-Guided Fine Needle Aspiration: A Narrative Review. Diagnostics (Basel) 2020; 10:diagnostics10110964. [PMID: 33213103 PMCID: PMC7698484 DOI: 10.3390/diagnostics10110964] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 11/05/2020] [Accepted: 11/16/2020] [Indexed: 02/06/2023] Open
Abstract
Considerable progress has been made recently in the use of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) to diagnose intra-luminal gastrointestinal lesions and extra-luminal lesions near the gastrointestinal tract. Numerous reports have indicated that EUS-FNA has high diagnostic performance and safety, which has led to the routine use of EUS-FNA and an increasing number of cases. Thus, while EUS-FNA has a low rate of complications, endoscopists may encounter these complications as the number of cases increases. Infrequent reports have also described life-threatening complications. Therefore, endoscopists should possess a comprehensive understanding of the complications of EUS-FNA, which include hemorrhage, perforation, infection, and acute pancreatitis, as well as their management. This review examines the available evidence regarding the complications associated with EUS-FNA, and the findings will be useful for ensuring that endoscopists perform EUS-FNA safely and appropriately.
Collapse
Affiliation(s)
| | - Shomei Ryozawa
- Correspondence: ; Tel.: +81-42-984-4111; Fax: +81-42-984-0432
| | | | | | | | | | | | | |
Collapse
|
41
|
Chan A, Philpott H, Lim AH, Au M, Tee D, Harding D, Chinnaratha MA, George B, Singh R. Anticoagulation and antiplatelet management in gastrointestinal endoscopy: A review of current evidence. World J Gastrointest Endosc 2020; 12:408-450. [PMID: 33269053 PMCID: PMC7677885 DOI: 10.4253/wjge.v12.i11.408] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 10/01/2020] [Accepted: 11/05/2020] [Indexed: 02/06/2023] Open
Abstract
The role of endoscopic procedures, in both diagnostic and therapeutic purposes is continually expanding and evolving rapidly. In this context, endoscopists will encounter patients prescribed on anticoagulant and antiplatelet medications frequently. This poses an increased risk of intraprocedural and delayed gastrointestinal bleeding. Thus, there is now greater importance on optimal pre, peri and post-operative management of anticoagulant and/or antiplatelet therapy to minimise the risk of post-procedural bleeding, without increasing the risk of a thromboembolic event as a consequence of therapy interruption. Currently, there are position statements and guidelines from the major gastroenterology societies. These are available to assist endoscopists with an evidenced-based systematic approach to anticoagulant and/or antiplatelet management in endoscopic procedures, to ensure optimal patient safety. However, since the publication of these guidelines, there is emerging evidence not previously considered in the recommendations that may warrant changes to our current clinical practices. Most notably and divergent from current position statements, is a growing concern regarding the use of heparin bridging therapy during warfarin cessation and its associated risk of increased bleeding, suggestive that this practice should be avoided. In addition, there is emerging evidence that anticoagulant and/or antiplatelet therapy may be safe to be continued in cold snare polypectomy for small polyps (< 10 mm).
Collapse
Affiliation(s)
- Andrew Chan
- Department of Gastroenterology, Lyell McEwin Hospital, Adelaide 5112, South Australia, Australia
| | - Hamish Philpott
- Department of Gastroenterology, Lyell McEwin Hospital, Adelaide 5112, South Australia, Australia
- School of Medicine, The University of Adelaide, Adelaide 5005, Australia
| | - Amanda H Lim
- Department of Gastroenterology, Lyell McEwin Hospital, Adelaide 5112, South Australia, Australia
| | - Minnie Au
- Department of Gastroenterology, Lyell McEwin Hospital, Adelaide 5112, South Australia, Australia
| | - Derrick Tee
- Department of Gastroenterology, Lyell McEwin Hospital, Adelaide 5112, South Australia, Australia
- School of Medicine, The University of Adelaide, Adelaide 5005, Australia
| | - Damian Harding
- Department of Gastroenterology, Lyell McEwin Hospital, Adelaide 5112, South Australia, Australia
- School of Medicine, The University of Adelaide, Adelaide 5005, Australia
| | - Mohamed Asif Chinnaratha
- Department of Gastroenterology, Lyell McEwin Hospital, Adelaide 5112, South Australia, Australia
- School of Medicine, The University of Adelaide, Adelaide 5005, Australia
| | - Biju George
- Department of Gastroenterology, Lyell McEwin Hospital, Adelaide 5112, South Australia, Australia
- School of Medicine, The University of Adelaide, Adelaide 5005, Australia
| | - Rajvinder Singh
- Department of Gastroenterology, Lyell McEwin Hospital, Adelaide 5112, South Australia, Australia
- School of Medicine, The University of Adelaide, Adelaide 5005, Australia
| |
Collapse
|
42
|
Wang Y, Wang RH, Ding Z, Tan SY, Chen Q, Duan YQ, Zhu LR, Cao JW, Wang J, Shi G, Wu XL, Wang JL, Zhao YC, Tang SJ, Cheng B. Wet- versus dry-suction techniques for endoscopic ultrasound-guided fine-needle aspiration of solid lesions: a multicenter randomized controlled trial. Endoscopy 2020; 52:995-1003. [PMID: 32413915 DOI: 10.1055/a-1167-2214] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND The optimal sampling techniques for endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) remain unclear and have not been standardized. The aim of this study was to compare the wet-suction and dry-suction techniques for sampling solid lesions in the pancreas, mediastinum, and abdomen. METHODS This was a multicenter, crossover, randomized controlled trial with randomized order of sampling techniques. The 296 consecutive patients underwent EUS-FNA with 22G needles and were randomized in a ratio of 1:1 into two separate groups that received the dry-suction and wet-suction techniques in a different order. The primary outcome was to compare the histological diagnostic accuracy of dry suction and wet suction for malignancy. The secondary outcomes were to compare the cytological diagnostic accuracy and specimen quality. RESULTS Among the 269 patients with pancreatic (n = 161) and non-pancreatic (n = 108) lesions analyzed, the wet-suction technique had a significantly better histological diagnostic accuracy (84.9 % [95 % confidence interval (CI) 79.9 % - 89.0 %] vs. 73.2 % [95 %CI 67.1 % - 78.7 %]; P = 0.001), higher specimen adequacy (94.8 % vs. 78.8 %; P < 0.001), and less blood contamination (P < 0.001) than the dry-suction technique. In addition, sampling non-pancreatic lesions with two passes of wet suction provided a histological diagnostic accuracy of 91.6 %. CONCLUSIONS The wet-suction technique in EUS-FNA generates better histological diagnostic accuracy and specimen quality than the dry-suction technique. Furthermore, sampling non-pancreatic lesions with two passes of EUS-FNA with wet suction may provide a definitive histological diagnosis when rapid on-site evaluation is not routinely available.
Collapse
Affiliation(s)
- Yun Wang
- Department of Gastroenterology and Hepatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Rong-Hua Wang
- Department of Gastroenterology and Hepatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Zhen Ding
- Division of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Shi-Yun Tan
- Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Qian Chen
- Department of Gastroenterology and Hepatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Ya-Qi Duan
- Institute of Pathology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.,Department of Pathology, School of Basic Medicine, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Liang-Ru Zhu
- Division of Gastroenterology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Ji-Wang Cao
- Department of Gastroenterology, Renmin Hospital of Wuhan University, Wuhan, China
| | - Jian Wang
- Department of Gastroenterology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Gan Shi
- Department of Gastroenterology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiao-Li Wu
- Department of Gastroenterology and Hepatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Jin-Lin Wang
- Department of Oncology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yu-Chong Zhao
- Department of Gastroenterology and Hepatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Shou-Jiang Tang
- Division of Digestive Diseases, Department of Medicine, University of Mississippi Medical Center, Jackson, Mississippi, USA
| | - Bin Cheng
- Department of Gastroenterology and Hepatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
43
|
Karsenti D, Palazzo L, Perrot B, Zago J, Lemaistre AI, Cros J, Napoléon B. 22G Acquire vs. 20G Procore needle for endoscopic ultrasound-guided biopsy of pancreatic masses: a randomized study comparing histologic sample quantity and diagnostic accuracy. Endoscopy 2020; 52:747-753. [PMID: 32408361 DOI: 10.1055/a-1160-5485] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
BACKGROUND : Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) has been suggested for obtaining high quality tissue samples from pancreatic tumors. We performed a multicenter randomized crossover trial comparing EUS-FNB with a 20G Procore needle vs. a 22G Acquire needle. The aims were to compare the quantity of targeted tissue (pancreas) and diagnostic accuracy for the two needles. METHODS : 60 patients admitted for EUS-FNB in three endoscopy units were included. One pass was performed consecutively with each needle, in a randomized order. Histologic material was studied in a blinded manner with respect to the needle. The primary end point was mean cumulative length of tissue core biopsies per needle pass. RESULTS : Final diagnosis was adenocarcinoma (n = 46; 77 %), neuroendocrine neoplasm (n = 11; 18 %), autoimmune pancreatitis (n = 2), and mass-forming chronic pancreatitis (n = 1). The mean cumulative length of tissue core biopsies per needle pass was significantly higher with the 22G Acquire needle at 11.4 mm (95 % confidence interval [CI] 9.0 - 13.8] vs. 5.4 mm (95 %CI 3.8 - 7.0) for the 20G Procore needle (P < 0.001), as was the mean surface area (3.5 mm2 [95 %CI 2.7 - 4.3] vs. 1.8 mm2 [95 %CI 1.2 - 2.3]; P < 0.001). Diagnostic adequacy and accuracy were 100 % and 87 % with the 22G Acquire needle, and 82 % and 67 % with the 20G Procore needle (P = 0.001 and P = 0.02, respectively). CONCLUSIONS : EUS-guided biopsy of pancreatic masses with the 22G Acquire needle provided more tissue for histologic evaluation and better diagnostic accuracy than the 20G Procore needle.
Collapse
Affiliation(s)
- David Karsenti
- Digestive Endoscopy Unit, Pôle Digestif Paris Bercy, Clinique de Paris-Bercy, Charenton-le-Pont, France
| | - Laurent Palazzo
- Digestive Endoscopy Unit, Clinique du Trocadéro, Paris, France
| | - Bastien Perrot
- UMR1246_SPHERE Methods for Patient-Centered Outcomes and Health Research, Nantes University, France
| | | | | | - Jérôme Cros
- Beaujon Hospital, Pathology Department, Université de Paris, INSERM U1149, Clichy, France
| | - Bertrand Napoléon
- Digestive Endoscopy Unit, Hôpital Privé Jean Mermoz, Ramsay Générale de Santé, Lyon, France
| |
Collapse
|
44
|
Soltani AK, Krishnan K. Current status of newer generation endoscopic ultrasound core needles in the diagnostic evaluation of gastrointestinal lesions. J Am Soc Cytopathol 2020; 9:389-395. [PMID: 32680792 DOI: 10.1016/j.jasc.2020.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 05/11/2020] [Accepted: 05/12/2020] [Indexed: 11/16/2022]
Abstract
Endoscopic ultrasound-guided tissue acquisition is now an imperative technique for the diagnosis of multiple diseases in the gastrointestinal tract and nearby structures. Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) and fine needle biopsy via dedicated FNB needles (EUS-FNB) are two standard-essential tools for tissue acquisition. The choice of needle type is an important factor determining appropriate tissue acquisition. Multiple studies have compared EUS-FNA versus EUS-FNB on different lesions also there are several studies evaluated different needles in terms of sampling adequacy and cytological and histological accuracy. Prior studies comparing prior-generation FNB needles to FNA did not show an increased diagnostic yield with FNB. However, the newer-generation needles have demonstrated enhanced performance compared with their predecessors. As they may provide a large amount of tissue for the cytological and histological evaluation, rapid onsite specimen evaluation (ROSE), and immunohistochemical and molecular analyses, which may be very important for targeted therapy. In this review, we discuss current evidence and literature on the use of the newer generation needles for pancreatic and non-pancreatic lesions.
Collapse
Affiliation(s)
- Amin K Soltani
- Department of Gastroenterology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Kumar Krishnan
- Department of Gastroenterology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts.
| |
Collapse
|
45
|
Luk Y, She WH, Chow FCL, Ma KW, Tsang SHY, Dai WC, Cheung TT, Lo CM. Evaluation of Pancreatic Lesions With Endoscopic Ultrasound and Fine Needle Aspiration. Surg Innov 2020; 27:431-438. [PMID: 32476606 DOI: 10.1177/1553350620925321] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Background. Endoscopic ultrasound (EUS) and fine-needle aspiration (FNA) are commonly used for assessing pancreatic lesions. This study aimed to evaluate the diagnostic yield and accuracy of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in a single tertiary institution. Methods. Consecutive patients who underwent EUS-FNA of the pancreas at Queen Mary Hospital, Hong Kong, from January 2015 to March 2016 were retrospectively reviewed. Endoscopic findings and FNA results were analysed. For patients who subsequently underwent surgical resection of pancreatic lesion, EUS-FNA diagnoses were compared to histopathological findings of surgical specimens to determine its diagnostic accuracy. Results. One hundred twelve EUS-FNA were performed in 99 patients within the study time period and were included for analysis. Sixty-six (66.7%) pancreatic lesions were solid in nature and 33 (33.3%) were cystic. The overall diagnostic yield of EUS-FNA was 70.5% (n = 79). On multivariate analysis, more passes of needle were associated with a higher diagnostic yield (odds ratio = 2.000, P = .049). 57.1% (n = 64) of EUS-FNA results had an impact on management. Sixteen patients with diagnostic EUS-FNA subsequently underwent surgery for resection of the pancreatic lesion. Upon correlation to the histopathological findings of surgical specimens, there were 12 true-positive, 2 true-negative, 0 false-positive, and 2 false-negative cases. Sensitivity was 85.7%, specificity was 100%, positive predictive value was 100%, and negative predictive value was 50%. The diagnostic accuracy of EUS-FNA was 87.5%. Conclusion. EUS-FNA is accurate and reliable for diagnosing pancreatic lesions.
Collapse
Affiliation(s)
- Yan Luk
- Department of Surgery, Queen Mary Hospital, 25809The University of Hong Kong, China
| | - Wong Hoi She
- Department of Surgery, Queen Mary Hospital, 25809The University of Hong Kong, China
| | - Felix Che Lok Chow
- Department of Surgery, Queen Mary Hospital, 25809The University of Hong Kong, China
| | - Ka Wing Ma
- Department of Surgery, Queen Mary Hospital, 25809The University of Hong Kong, China
| | - Simon Hing Yin Tsang
- Department of Surgery, Queen Mary Hospital, 25809The University of Hong Kong, China
| | - Wing Chiu Dai
- Department of Surgery, Queen Mary Hospital, 25809The University of Hong Kong, China
| | - Tan To Cheung
- Department of Surgery, Queen Mary Hospital, 25809The University of Hong Kong, China
| | - Chung Mau Lo
- Department of Surgery, Queen Mary Hospital, 25809The University of Hong Kong, China
| |
Collapse
|
46
|
Mita N, Iwashita T, Uemura S, Iwasa Y, Toda K, Mukai T, Miyazaki T, Yasuda I, Shimizu M. Endoscopic Ultrasound-Guided Fine Needle Biopsy Using 22-Gauge Franseen Needle for the Histological Diagnosis of Solid Lesions: A Multicenter Prospective Pilot Study. Dig Dis Sci 2020; 65:1155-1163. [PMID: 31531819 DOI: 10.1007/s10620-019-05840-y] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Accepted: 09/10/2019] [Indexed: 12/16/2022]
Abstract
BACKGROUND Recently, a novel 22-gauge needle with three symmetric needle points and crown-shaped cutting heels, known as a Franseen needle, has been developed for endoscopic ultrasound-guided fine needle biopsy (EUS-FNB). AIM To assess the histological material acquisition rate and histological diagnostic capability of the 22-gauge Franseen needle (AC22) during EUS-FNB for solid lesions. METHODS This study was designed as an open-label, multicenter, prospective, single-arm pilot study of EUS-FNB using AC22 for the diagnosis of solid lesions. Three passes of FNB using AC22 were performed for all lesions. The primary endpoints were the histological material acquisition rate and histological diagnostic capability. The secondary endpoints were the technical success rate, quality of histological samples, number of passes for diagnosis, and safety. RESULTS Between September 2017 and May 2018, 75 patients were enrolled. The final diagnoses were malignancy in 65 and benign in 10. Three passes of FNB were technically successful in all patients. The sensitivity, specificity, and accuracy for the malignancy of histological analyses were 92.3% (60/65), 100% (10/10), and 93.3% (70/75), respectively, for the first pass and 95.4% (62/65), 100% (10/10), and 96% (72/75), respectively, for combined three passes. The diagnostic yield plateaued after the second pass. Sufficient tissue samples for histological interpretation were obtained in 96% (72/75) and 100% (75/75) patients for the single pass and combined three passes, respectively. Two patients (2.7%) developed mild pancreatitis as an adverse event. CONCLUSION EUS-FNB using AC22 showed high histological diagnostic capability with the high first pass yield. CLINICAL TRIALS REGISTRY UMIN Clinical Trials Registry (UMIN ID: UMIN000036641).
Collapse
Affiliation(s)
- Naoki Mita
- First Department of Internal Medicine, Gifu University Hospital, 1-1 Yanagido, Gifu, 501-1194, Japan
| | - Takuji Iwashita
- First Department of Internal Medicine, Gifu University Hospital, 1-1 Yanagido, Gifu, 501-1194, Japan.
| | - Shinya Uemura
- First Department of Internal Medicine, Gifu University Hospital, 1-1 Yanagido, Gifu, 501-1194, Japan
| | - Yuhei Iwasa
- First Department of Internal Medicine, Gifu University Hospital, 1-1 Yanagido, Gifu, 501-1194, Japan
| | - Katsuhisa Toda
- Department of Gastroenterology, Chuno Kosei Hospital, Gifu, Japan
| | - Tsuyoshi Mukai
- Department of Gastroenterology, Gifu Municipal Hospital, Gifu, Japan
| | | | - Ichiro Yasuda
- Third Department of Internal Medicine, University of Toyama Hospital, Toyama, Japan
| | - Masahito Shimizu
- First Department of Internal Medicine, Gifu University Hospital, 1-1 Yanagido, Gifu, 501-1194, Japan
| |
Collapse
|
47
|
Abstract
Important advancements in endoscopic ultrasound-guided tissue sampling techniques and development of new needle designs have improved the diagnostic yield of pancreatic lesions. This innovation in endoscopic ultrasound has also opened the door for early diagnosis and precision therapy in the management of cancer patients. Endoscopic ultrasound fine needle biopsy is an invaluable tool and newer biopsy designs will probably play a pivotal role in the management of pancreatic lesions in the next future. Aim of the current review was to provide an overview on the available techniques and devices for the endoscopic ultrasound-guided sampling of pancreatic solid and cystic lesions.
Collapse
|
48
|
Grassia R, Imperatore N, Capone P, Cereatti F, Forti E, Antonini F, Tanzi GP, Martinotti M, Buffoli F, Mutignani M, Macarri G, Manes G, Vecchi M, De Nucci G. EUS-guided tissue acquisition in chronic pancreatitis: Differential diagnosis between pancreatic cancer and pseudotumoral masses using EUS-FNA or core biopsy. Endosc Ultrasound 2020; 9:122-129. [PMID: 32295970 PMCID: PMC7279087 DOI: 10.4103/eus.eus_75_19] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Accepted: 11/18/2019] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND AND OBJECTIVE EUS-FNA sensitivity for malignancy in parenchymal masses of patients with concurrent chronic pancreatitis (CP) has been reported to be unsatisfactory. The aim of the present study was to directly compare the diagnostic accuracy of EUS-FNA and EUS-fine-needle biopsy (FNB) in differentiating between inflammatory masses and malignancies in the setting of CP. METHODS We performed a retrospective analysis of prospective, multicentric databases of all patients with pancreatic masses and clinico-radiological-endosonographic features of CP who underwent EUS-FNA or FNB. RESULTS Among 1124 patients with CP, 210 patients (60% males, mean age: 62.7 years) with CP and pancreatic masses met the inclusion criteria and were enrolled. In the FNA group (110 patients), a correct diagnosis was obtained in all but 18 cases (diagnostic accuracy 83.6%, sensitivity 69.5%, specificity 100%, positive predictive value [PPV] 100%, and negative predictive value [NPV] 73.9%); by contrast, among 100 patients undergoing FNB, a correct diagnosis was obtained in all but seven cases (diagnostic accuracy 93%, sensitivity 86.8%, specificity 100%, PPV 100%, and NPV 87%) (P = 0.03, 0.03, 1, 1, and 0.07, respectively). At binary logistic regression, focal pancreatitis (odds of event occurrence [OR]: 4.9; P < 0.001), higher Ca19-9 (OR: 2.3;P= 0.02), and FNB (OR: 2.5; P < 0.01) were the only independent factors associated with a correct diagnosis. CONCLUSION EUS-FNB is effective in the differential diagnosis between pseudotumoral masses and solid neoplasms in CP, showing higher diagnostic accuracy and sensitivity than EUS-FNA. EUS-FNB should be considered the preferred diagnostic technique for diagnosing cancer in the setting of CP.
Collapse
Affiliation(s)
- Roberto Grassia
- Gastroenterology and Digestive Endoscopy Unit, Cremona Hospital, Cremona, Italy
| | - Nicola Imperatore
- Gastroenterology, Department of Clinical Medicine and Surgery, School of Medicine, “Federico II” of Naples, Naples, Italy
| | - Pietro Capone
- Gastroenterology and Digestive Endoscopy Unit, Hospital “A. Maresca”, Torre del Greco, Naples, Italy
| | - Fabrizio Cereatti
- Gastroenterology and Digestive Endoscopy Unit, Cremona Hospital, Cremona, Italy
| | - Edoardo Forti
- Gastroenterology Unit, Niguarda Ca' Granda Hospital, Milan, Italy
| | - Filippo Antonini
- Department of Gastroenterology, A. Murri Hospital, Polytechnic University of Marche, Fermo, Italy
| | | | | | - Federico Buffoli
- Gastroenterology and Digestive Endoscopy Unit, Cremona Hospital, Cremona, Italy
| | | | - Giampiero Macarri
- Department of Gastroenterology, A. Murri Hospital, Polytechnic University of Marche, Fermo, Italy
| | - Gianpiero Manes
- Gastroenterology and Digestive Endoscopy Unit, A.O. Salvini, Garbagnate Milanese, Milan, Italy
| | - Maurizio Vecchi
- Gastroenterology and Gastrointestinal Endoscopy Unit, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy
| | - Germana De Nucci
- Gastroenterology and Digestive Endoscopy Unit, A.O. Salvini, Garbagnate Milanese, Milan, Italy
| |
Collapse
|
49
|
Kurita A, Yasukawa S, Zen Y, Yoshimura K, Ogura T, Ozawa E, Okabe Y, Asada M, Nebiki H, Shigekawa M, Ikeura T, Eguchi T, Maruyama H, Ueki T, Itonaga M, Hashimoto S, Shiomi H, Minami R, Hoki N, Takenaka M, Itokawa Y, Uza N, Hashigo S, Yasuda H, Takada R, Kamada H, Kawamoto H, Kawakami H, Moriyama I, Fujita K, Matsumoto H, Hanada K, Takemura T, Yazumi S. Comparison of a 22-gauge Franseen-tip needle with a 20-gauge forward-bevel needle for the diagnosis of type 1 autoimmune pancreatitis: a prospective, randomized, controlled, multicenter study (COMPAS study). Gastrointest Endosc 2020; 91:373-381.e2. [PMID: 31654634 DOI: 10.1016/j.gie.2019.10.012] [Citation(s) in RCA: 74] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Accepted: 10/03/2019] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS Histologic diagnosis of autoimmune pancreatitis (AIP) using EUS-guided FNA (EUS-FNA) is difficult. To address this issue, new fine-needle biopsy (FNB) needles were recently developed. Here, we prospectively evaluated 2 newly designed EUS-FNB needles for histologic evaluation in patients with type 1 AIP. METHODS This was a prospective, randomized, multicenter trial comparing biopsy specimens obtained with a 22-gauge Franseen needle or a 20-gauge forward-bevel needle in patients with suspected type 1 AIP. AIP was diagnosed according to international consensus diagnostic criteria. The primary endpoint was the sensitivity of EUS-FNB needles, and secondary endpoints were the amount of specimen obtained, histology of the pancreas based on evaluation of lymphoplasmacytic sclerosing pancreatitis (LPSP), and contribution of histologic findings to the diagnosis of AIP. RESULTS One hundred ten patients were randomly assigned to the Franseen group (22-gauge Franseen needle) or the forward-bevel group (20-gauge forward-bevel needle). EUS-FNB sampling was successful in all patients. Nine patients were excluded because of diagnoses other than AIP. Compared with the forward-bevel needle, the Franseen needle obtained a significantly greater number of high-power fields. Of 101 patients, 39 patients (78%) in the Franseen group and 23 patients (45%) in the Forward-bevel group were diagnosed with level 1 or 2 LPSP (P = .001). Thirty-six patients could not be diagnosed with type 1 AIP without EUS-FNB specimen results. CONCLUSIONS The 22-gauge Franseen needle should be routinely used for histologic diagnosis of type 1 AIP. (Clinical trial registration number: UMIN 000027668.).
Collapse
Affiliation(s)
- Akira Kurita
- Department of Gastroenterology and Hepatology, Kitano Hospital, Tazuke Kofukai Medical Research Institute, Osaka, Japan
| | - Satoru Yasukawa
- Department of Pathology, Kyoto Second Red Cross Hospital, Kyoto, Japan
| | - Yoh Zen
- Institute of Liver Studies, King's College Hospital, Denmark Hill, London, United Kingdom
| | - Kenichi Yoshimura
- Innovative Clinical Research Center, Kanazawa University Hospital, Ishikawa, Japan
| | - Takeshi Ogura
- 2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan
| | - Eisuke Ozawa
- Department of Gastroenterology and Hepatology, Nagasaki University Hospital, Nagasaki, Japan
| | - Yoshinobu Okabe
- Division of Gastroenterology, Department of Medicine, Kurume University, Fukuoka, Japan
| | - Masanori Asada
- Department of Gastroenterology and Hepatology, Japanese Red Cross Osaka Hospital, Osaka, Japan
| | - Hiroko Nebiki
- Department of Gastroenterology, Osaka City General Hospital, Osaka, Japan
| | - Minoru Shigekawa
- Department of Gastroenterology and Hepatology, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Tsukasa Ikeura
- The Third Department of Internal Medicine, Kansai Medical University, Osaka, Japan
| | - Takaaki Eguchi
- Department of Gastroenterology and Hepatology, Osaka Saiseikai Nakatsu Hospital, Osaka, Japan
| | - Hirotsugu Maruyama
- Department of Gastroenterology, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - Toshiharu Ueki
- Department of Gastroenterology, Fukuoka University Chikushi Hospital, Fukuoka, Japan
| | - Masahiro Itonaga
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Shinichi Hashimoto
- Digestive and Lifestyle Diseases, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
| | - Hideyuki Shiomi
- Division of Gastroenterology, Department of Internal Medicine, Graduate School of Medicine, Kobe University, Hyogo, Japan
| | - Ryuki Minami
- Department of Gastroenterology, Tenri Hospital, Nara, Japan
| | - Noriyuki Hoki
- Division of Gastroenterology and Hepatology, Bell Land General Hospital, Sakai, Japan
| | - Mamoru Takenaka
- Departments of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka, Japan
| | - Yoshio Itokawa
- Digestive disease Center, Department of Gastroenterology & Hepatology, Kyoto Katsura Hospital, Kyoto, Japan
| | - Norimitsu Uza
- Department of Gastroenterology and Hepatology, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Shunpei Hashigo
- Department of Gastroenterology and Hepatology, Graduate School of Medical Sciences Kumamoto University, Kumamoto, Japan
| | - Hiroaki Yasuda
- Molecular Gastroenterology and Hepatology, Kyoto Prefectural University of Medicine Graduate School of Medical Science, Kyoto, Japan
| | - Ryoji Takada
- Department of Hepatobiliary and Pancreatic Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Hideki Kamada
- Department of Gastroenterology and Neurology, Kagawa University, Kagawa, Japan
| | - Hirofumi Kawamoto
- Department of General Internal Medicine 2, Kawasaki Medical School, Okayama, Japan
| | - Hiroshi Kawakami
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan
| | - Ichiro Moriyama
- Innovative Cancer Center, Shimane University Hospital, Shimane, Japan
| | - Koichi Fujita
- Department of Gastroenterology, Yodogawa Christian Hospital, Osaka, Japan
| | - Hisakazu Matsumoto
- Department of Gastroenterology and Hepatology, Japanese Red Cross Wakayama Medical Center, Wakayama, Japan
| | - Keiji Hanada
- Department of Gastroenterology, Onomichi General Hospital, Onomichi, Japan
| | - Tadamasa Takemura
- Graduate School of Applied Informatics, University of Hyogo, Hyogo, Japan
| | - Shujiro Yazumi
- Department of Gastroenterology and Hepatology, Kitano Hospital, Tazuke Kofukai Medical Research Institute, Osaka, Japan
| |
Collapse
|
50
|
Fujie S, Ishiwatari H, Sasaki K, Sato J, Matsubayashi H, Yoshida M, Ito S, Kawata N, Imai K, Kakushima N, Takizawa K, Hotta K, Ono H. Comparison of the Diagnostic Yield of the Standard 22-Gauge Needle and the New 20-Gauge Forward-Bevel Core Biopsy Needle for Endoscopic Ultrasound-Guided Tissue Acquisition from Pancreatic Lesions. Gut Liver 2020; 13:349-355. [PMID: 30600677 PMCID: PMC6529169 DOI: 10.5009/gnl18189] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2018] [Revised: 08/30/2018] [Accepted: 09/24/2018] [Indexed: 01/20/2023] Open
Abstract
Background/Aims To compare the diagnostic yield of 20-gauge forward-bevel core biopsy needle (CBN) and 22-gauge needle for endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) of solid pancreatic masses. Methods The use of 20-gauge CBN was prospectively evaluated for 50 patients who underwent EUS-FNA from June 2016 to December 2016. Data were compared with those obtained by a retrospective study of 50 consecutive patients who underwent EUS-FNA using standard 22-gauge needles between December 2016 and April 2017. At least two punctures were performed for each patient; the sample from the first pass was used for cytology with or without histology and that from the second pass was used for histology. Sample quantity was evaluated using the sample obtained from the second pass. Results There was no significant difference in the diagnostic accuracy rate between the first and second passes (20-gauge CBN: 96% [48/50]; standard 22-gauge needle: 88% [44/50]). Samples >10× power fields in length were obtained from 90% (43/48) and 60% (30/50) of patients using the 20-gauge CBN and standard 22-gauge needle, respectively (p=0.01). Technical failure occurred for two patients with the 20-gauge CBN. Conclusions Diagnostic accuracy of the 20-gauge CBN was comparable to that of the 22-gauge needle. However, two passes with the 20-gauge CBN yielded a correct diagnosis for 100% of patients when technically feasible. Moreover, the 20-gauge CBN yielded core tissue for 90% patients, which was a performance superior to that of the 22-gauge needle.
Collapse
Affiliation(s)
- Shinya Fujie
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | | | - Keiko Sasaki
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Junya Sato
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | | | - Masao Yoshida
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Sayo Ito
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Noboru Kawata
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Kenichiro Imai
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Naomi Kakushima
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Kohei Takizawa
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Kinichi Hotta
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| | - Hiroyuki Ono
- Division of Endoscopy, Shizuoka Cancer Center, Shizuoka, Japan
| |
Collapse
|