1
|
Su HJ, Chen CC, Kuo YT, Han ML, Tsai MC, Liu KL, Wang HP. Clinical outcomes of different types of metallic stents in malignant distal duodenum stenosis: A retrospective study. J Formos Med Assoc 2024; 123:854-859. [PMID: 38171957 DOI: 10.1016/j.jfma.2023.12.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Revised: 12/06/2023] [Accepted: 12/20/2023] [Indexed: 01/05/2024] Open
Abstract
BACKGROUND/PURPOSE Endoscopic stenting at malignant distal duodenum stenosis (MDDS) is challenging because of the duodenal C-loop configuration, the acute angle of the duodenojejunal junction, and the limited length of the endoscope. Few studies have investigated the clinical outcomes of stenting at the distal duodenum. Therefore, this study aimed to investigate the clinical outcomes of treating MDDS with different types of metallic stents. METHODS From January 2012 to December 2020, fifty-six patients with MDDS who underwent duodenal stenting were enrolled for analysis. Thirty-five patients received uncovered self-expandable metallic stents (UC-SEMS), and twenty-one patients received partially covered self-expandable metallic stents (PC-SEMS). All patients were followed up till death or for 18 months. The clinical success rate, stent dysfunction rate, and stent patency were compared between the groups. Multivariate analysis was conducted to identify factors related to stent dysfunction. RESULTS The clinical success rates were 85.7 % in both the UC-SEMS and PC-SEMS groups. Stent dysfunction rates (UC-SEMS: 34.3 %, PC-SEMS: 38.1 %, p = 0.773) and the average stent patency (UC-SEMS: 117.2 days, PC-SEMS: 100.0 days, p = 0.576) were not statistically different between the groups. Multivariate analysis disclosed the age ≥65 years was significantly related to stent dysfunction (odds ratio: 4.78, p = 0.031). CONCLUSION Both UC-SEMS and PC-SEMS are safe and effective treatment options for MDDS. However, stent dysfunction remains a significant issue to overcome, particularly in the elderly. Further research is needed to explore novel strategies that can improve the effectiveness of stent placement and reduce the risk of stent dysfunction.
Collapse
Affiliation(s)
- Hau-Jyun Su
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Chung Shan Medical University Hospital, Taichung, Taiwan; School of Medicine, Chung Shan Medical University, Taichung, Taiwan
| | - Chieh-Chang Chen
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan; Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan; Graduate Institute of Clinical Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Yu-Ting Kuo
- Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan; Division of Endoscopy, Department of Integrated Diagnostics and Therapeutics, National Taiwan University Hospital, Taipei, Taiwan
| | - Ming-Lun Han
- Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan; Division of Endoscopy, Department of Integrated Diagnostics and Therapeutics, National Taiwan University Hospital, Taipei, Taiwan
| | - Ming-Chang Tsai
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, Chung Shan Medical University Hospital, Taichung, Taiwan; School of Medicine, Chung Shan Medical University, Taichung, Taiwan
| | - Kao-Lang Liu
- Department of Medical Imaging, National Taiwan University Cancer Center, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei, Taiwan
| | - Hsiu-Po Wang
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan; Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan.
| |
Collapse
|
2
|
Feng Y, Chen Y, Chen Y, He X, Khan Y, Hu H, Lan P, Li Y, Wang X, Li G, Kaplan D. Intestinal stents: Structure, functionalization and advanced engineering innovation. BIOMATERIALS ADVANCES 2022; 137:212810. [PMID: 35929235 DOI: 10.1016/j.bioadv.2022.212810] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 04/08/2022] [Accepted: 04/13/2022] [Indexed: 06/15/2023]
Abstract
Intestinal stents are a palliative treatment option that solves many shortcomings of traditional surgeries for cancer-induced intestinal obstructions. The present review provides an overview of the incidence, clinical manifestations and limitations in the treatment of intestinal cancers. The paper also discusses material property requirements, indications, complications and the future of stent-assisted therapy. The advantages and disadvantages of different materials and processing techniques for intestinal stents are reviewed along with new stent treatment combinations for colorectal cancer. Challenges that require further cooperative studies are also detailed. The future development of intestinal stents will depend on innovation in material designs as well as the utilization of multi-functional strategies and innovative engineering solutions.
Collapse
Affiliation(s)
- Yusheng Feng
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, Jiangsu, China
| | - Yufeng Chen
- Department of Colorectal Surgery, Guangdong Provincial Key Laboratory of Colorectal and Pelvic Floor Diseases, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou 510655, Guangdong, China
| | - Ying Chen
- Department of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, MA 02155, USA
| | - Xiaowen He
- Department of Colorectal Surgery, Guangdong Provincial Key Laboratory of Colorectal and Pelvic Floor Diseases, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou 510655, Guangdong, China
| | - Yousef Khan
- Department of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, MA 02155, USA
| | - Hong Hu
- Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China
| | - Ping Lan
- Department of Colorectal Surgery, Guangdong Provincial Key Laboratory of Colorectal and Pelvic Floor Diseases, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou 510655, Guangdong, China
| | - Yi Li
- Department of Materials, University of Manchester, Oxford Road, Manchester M13 9PL, UK
| | - Xiaoqin Wang
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, Jiangsu, China
| | - Gang Li
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, Jiangsu, China.
| | - David Kaplan
- Department of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, MA 02155, USA.
| |
Collapse
|
3
|
Jiang C, Wang K, Liu Y, Zhang C, Wang B. Application of textile technology in tissue engineering: A review. Acta Biomater 2021; 128:60-76. [PMID: 33962070 DOI: 10.1016/j.actbio.2021.04.047] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Revised: 03/26/2021] [Accepted: 04/26/2021] [Indexed: 12/14/2022]
Abstract
One of the key elements in tissue engineering is to design and fabricate scaffolds with tissue-like properties. Among various scaffold fabrication methods, textile technology has shown its unique advantages in mimicking human tissues' properties such as hierarchical, anisotropic, and strain-stiffening properties. As essential components in textile technology, textile patterns affect the porosity, architecture, and mechanical properties of textile-based scaffolds. However, the potential of various textile patterns has not been fully explored when fabricating textile-based scaffolds, and the effect of different textile patterns on scaffold properties has not been thoroughly investigated. This review summarizes textile technology development and highlights its application in tissue engineering to facilitate the broader application of textile technology, especially various textile patterns in tissue engineering. The potential of using different textile methods such as weaving, knitting, and braiding to mimic properties of human tissues is discussed, and the effect of process parameters in these methods on fabric properties is summarized. Finally, perspectives on future directions for explorations are presented. STATEMENT OF SIGNIFICANCE: Recently, biomedical engineers have applied textile technology to fabricate scaffolds for tissue engineering applications. Various textile methods, especially weaving, knitting, and braiding, enables engineers to customize the physical, mechanical, and biological properties of scaffolds. However, most textile-based scaffolds only use simple textile patterns, and the effect of different textile patterns on scaffold properties has not been thoroughly investigated. In this review, we cover for the first time the effect of process parameters in different textile methods on fabric properties, exploring the potential of using different textile methods to mimic properties of human tissues. Previous advances in textile technology are presented, and future directions for explorations are presented, hoping to facilitate new breakthroughs of textile-based tissue engineering.
Collapse
Affiliation(s)
- Chen Jiang
- School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States; Georgia Tech Manufacturing Institute, Georgia Institute of Technology, Atlanta, GA 30332, United States
| | - Kan Wang
- Georgia Tech Manufacturing Institute, Georgia Institute of Technology, Atlanta, GA 30332, United States.
| | - Yi Liu
- Georgia Tech Manufacturing Institute, Georgia Institute of Technology, Atlanta, GA 30332, United States; School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30318, United States
| | - Chuck Zhang
- Georgia Tech Manufacturing Institute, Georgia Institute of Technology, Atlanta, GA 30332, United States; H. Milton Stewart School of Industrial and System Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States
| | - Ben Wang
- School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States; Georgia Tech Manufacturing Institute, Georgia Institute of Technology, Atlanta, GA 30332, United States; H. Milton Stewart School of Industrial and System Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States
| |
Collapse
|
4
|
Kato H, Kawamoto H, Matsumoto K, Moriyama I, Kamada H, Tsutsumi K, Goto D, Fukuba N, Kato K, Sonoyama H, Isomoto H, Okada H. Outcome of self-expandable metallic stent deployment in patients with malignant gastroduodenal outlet obstruction and Niti-S and WallFlex comparison: a multicenter retrospective clinical study. J Dig Dis 2016; 17:518-525. [PMID: 27383654 DOI: 10.1111/1751-2980.12377] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Revised: 06/20/2016] [Accepted: 06/30/2016] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Several studies report on the outcomes of self-expandable metallic stents (SEMSs) deployment for malignant gastric outlet obstruction (GOO). However, data was mostly based on the analysis of single-center studies including only a small number of patients. This study aimed to evaluate clinical outcomes after the deployment of SEMS in patients with malignant GOO and to compare the clinical outcomes of two metallic stents with different designs. METHODS Altogether 125 consecutive patients from five institutions were included. Clinical outcomes were evaluated according to technical success, clinical success, stent patency period, survival period and complications. A comparison of clinical outcomes between Niti-S pyloric/duodenal and WallFlex duodenal stents was also undertaken. RESULTS Rates for clinical and technical success were 100% and 92.0%, respectively. The median stent patency and survival periods were 72.0 days (range 3-775 days) and 75.0 days (range 3-775 days), respectively. The rate of overall adverse events was 28.8%. The rate of stent dysfunction was 16.8%, and that of adverse events, except stent dysfunction was 12.0%. Massive bleeding occurred in two patients as a late complication. The clinical success rate for Niti-S stent was significantly higher than that for WallFlex stent (96.2% vs 84.8%, P = 0.023). CONCLUSIONS We successfully deployed a SEMS in malignant GOO. The selection of a SEMS with a lower axial force may be important for patients to resume the oral food intake. Additionally, consideration must be given to the appropriate management of fatal bleeding as a late complication.
Collapse
Affiliation(s)
- Hironari Kato
- Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan. .,Hakushusanbi Endoscopic Workshop Group, Japan.
| | - Hirofumi Kawamoto
- Department of General Internal Medicine 2, Kawasaki Medical School, Okayama, Japan.,Hakushusanbi Endoscopic Workshop Group, Japan
| | - Kazuya Matsumoto
- Department of Gastroenterology, Tottori University Hospital, Yonago, Japan.,Hakushusanbi Endoscopic Workshop Group, Japan
| | - Ichiro Moriyama
- Division of Clinical study of Oncology, Shimane University School of Medicine, Izumo, Japan.,Hakushusanbi Endoscopic Workshop Group, Japan
| | - Hideki Kamada
- Department of Gastroenterology and Neurology, Kagawa University, Kagawa, Japan.,Hakushusanbi Endoscopic Workshop Group, Japan
| | - Koichiro Tsutsumi
- Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| | - Daisuke Goto
- Department of Gastroenterology and Hepatology, Tottori Municipal Hospital, Tottori, Japan
| | - Nobuhiko Fukuba
- Department of Internal Medicine II, Shimane University School of Medicine, Izumo, Japan
| | - Kiyohito Kato
- Department of Gastroenterology and Neurology, Kagawa University, Kagawa, Japan
| | - Hiroki Sonoyama
- Department of Internal Medicine II, Shimane University School of Medicine, Izumo, Japan
| | - Hajime Isomoto
- Department of Gastroenterology, Tottori University Hospital, Yonago, Japan
| | - Hiroyuki Okada
- Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
| |
Collapse
|
5
|
Self-expandable metal stent placement for malignant duodenal obstruction distal to the bulb. Eur J Gastroenterol Hepatol 2015; 27:1466-72. [PMID: 26426837 DOI: 10.1097/meg.0000000000000479] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVE Self-expandable metal stents (SEMS) are widely used for the palliative management of malignant proximal gastroduodenal obstruction because of its low morbidity and mortality rates compared with surgical bypass. However, stent placement for duodenal obstruction beyond the first part of the duodenum is considered technically difficult and is not routinely performed. We report our experience with SEMS placement for these patients. METHODS Between 2006 and 2015, 51 patients with unresectable or metastatic malignancy underwent SEMS placements under combined endoscopic and fluoroscopic guidance. Eighteen patients had intestinal obstruction distal to the duodenal bulb. Their demographics, technical and clinical outcomes, periprocedural morbidity and mortality, length of hospital stay, further interventions and overall survival were analysed. RESULTS Out of the 18 cases, nine cases of intestinal obstruction were due to primary malignancy of the pancreas, three due to gastric malignancy, three from other locoregional cancers and three were the result of metastases. In 12 patients, the obstruction involved the second part (D2), in four the third part (D3) and in two the fourth part (D4) of the duodenum. A front-facing therapeutic gastroscope was used to visualize the duodenum before the stricture was crossed under direct vision and fluoroscopic guidance, with a catheter and guidewire, and a through-the-scope SEMS deployed using an 'over-the-wire' technique. Technical success rate was 89%. The mean gastric outlet obstruction scores improved from 0.63 to 2.57 (P<0.0001). Four patients died within 30 days of the procedure, although none of the deaths were procedure related. The median length of postprocedural hospital stay was 4 days and the median overall survival was 58 days.
Collapse
|
6
|
van Halsema EE, Rauws EAJ, Fockens P, van Hooft JE. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature. World J Gastroenterol 2015; 21:12468-81. [PMID: 26604654 PMCID: PMC4649130 DOI: 10.3748/wjg.v21.i43.12468] [Citation(s) in RCA: 74] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2015] [Revised: 07/17/2015] [Accepted: 10/12/2015] [Indexed: 02/06/2023] Open
Abstract
AIM To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). METHODS A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that reported on the clinical success of stent placement for MGOO were included. The primary endpoint was clinical success, defined according to the definition used in the original article. Data were pooled and analyzed using descriptive statistics. Subgroup analyses were performed for partially covered SEMSs (PCSEMSs) and uncovered SEMSs (UCSEMSs) using Fisher's exact test. RESULTS A total of 19 studies, including 1281 patients, were included in the final analysis. Gastric (42%) and pancreatic (37%) cancer were the main causes of MGOO. UCSEMSs were used in 76% of patients and PCSEMSs in 24%. The overall pooled technical success rate was 97.3% and the clinical success rate was 85.7%. Stent dysfunction occurred in 19.6% of patients, mainly caused by re-obstruction (12.6%) and stent migration (4.3%), and was comparable between PCSEMSs and UCSEMSs (21.2% vs 19.1%, respectively, P = 0.412). Re-obstruction was more common with UCSEMSs (14.9% vs 5.1%, P < 0.001) and stent migration was more frequent after PCSEMS placement (10.9% vs 2.2%, P < 0.001). The overall perforation rate was 1.2%. Bleeding was reported in 4.1% of patients, including major bleeding in 0.8%. The median stent patency ranged from 68 to 307 d in five studies. The median overall survival ranged from 49 to 183 d in 13 studies. CONCLUSION The clinical outcomes in this large population showed that enteral stent placement was feasible, effective and safe. Therefore, stent placement is a valid treatment option for the palliation of MGOO.
Collapse
|