1
|
Urban M, Vasconcelos L, Brom K, Dave J, Kijanka P. Shear wave elastography primer for the abdominal radiologist. Abdom Radiol (NY) 2025:10.1007/s00261-025-04806-1. [PMID: 39883164 DOI: 10.1007/s00261-025-04806-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2024] [Revised: 01/10/2025] [Accepted: 01/11/2025] [Indexed: 01/31/2025]
Abstract
PURPOSE Shear wave elastography (SWE) provides a means for adding information about the mechanical properties of tissues to a diagnostic ultrasound examination. It is important to understand the physics and methods by which the measurements are made to aid interpretation of the results as they relate to disease processes. METHODS The components of how ultrasound is used to generate shear waves and make measurements of the induced motion are reviewed. The physics of shear wave propagation are briefly described for elastic and viscoelastic tissues. Additionally, shear wave propagation in homogeneous and inhomogeneous cases is addressed. RESULTS SWE technology has been implemented by many clinical vendors with different capabilities. Various quality metrics are used to define valid measurements based on aspects of the shear wave signals or wave velocity estimates. CONCLUSION There are many uses for SWE in abdominal imaging, but it is important to understand how the measurements are performed to gauge their utility for diagnosis of different conditions. Continued efforts to make the technology robust in complex clinical situations are ongoing, but many applications actively benefit from added information about tissue mechanical properties for a more holistic view of the patient for diagnosis or assessment of prognosis and treatment management.
Collapse
|
2
|
Hari A, Štabuc B. Possible use of 2D shear wave liver elastography in new-onset ascites evaluation. BMC Gastroenterol 2024; 24:68. [PMID: 38331713 PMCID: PMC10851554 DOI: 10.1186/s12876-024-03159-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 02/05/2024] [Indexed: 02/10/2024] Open
Abstract
BACKGROUND No data on the use of 2D shear wave elastography exists regarding the evaluation of the new-onset ascites causality. AIMS To determine whether 2D shear wave elastography can help in the non-invasive assessment of the new-onset ascites cause. To assess the applicability of liver stiffness measured by 2D shear wave elastography using Esaote MyLab Nine apparatus in patients with ascites. METHODS In 52 consecutive patients with new-onset ascites (January 2020 to October 2021), liver stiffness using 2D shear wave elastography was prospectively measured. The reliable measurements were used for further analysis. Relevant clinical and laboratory data was collected. RESULTS The calculated liver stiffness measurement cut-off value of 14.4 kPa held 94% accuracy, 100% sensitivity, and 83% specificity when determining ascites with serum ascites albumin gradient ≥11 g/L. Reliable 2D shear wave elastography success rate was 84%. CONCLUSIONS 2D shear wave elastography may potentially be used to differentiate transudative from exudative ascites, especially in patients with portal hypertension and peritoneal carcinomatosis.
Collapse
Affiliation(s)
- Andrej Hari
- Department of gastroenterology and hepatology, University Medical Centre Ljubljana, Ljubljana, Slovenia.
| | - Borut Štabuc
- Department of gastroenterology and hepatology, University Medical Centre Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
3
|
Taiji R, Cortes AC, Zaske AM, Williams M, Dupuis C, Tanaka T, Nishiofuku H, Chintalapani G, Peterson CB, Avritscher R. Liver Cancer Vascularity Driven by Extracellular Matrix Stiffness: Implications for Imaging Research. Invest Radiol 2023; 58:894-902. [PMID: 37403975 DOI: 10.1097/rli.0000000000001001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/06/2023]
Abstract
BACKGROUND Extracellular matrix stiffness represents a barrier to effective local and systemic drug delivery. Increasing stiffness disrupts newly formed vessel architecture and integrity, leading to tumor-like vasculature. The resulting vascular phenotypes are manifested through different cross-sectional imaging features. Contrast-enhanced studies can help elucidate the interplay between liver tumor stiffness and different vascular phenotypes. PURPOSE This study aims to correlate extracellular matrix stiffness, dynamic contrast-enhanced computed tomography, and dynamic contrast-enhancement ultrasound imaging features of 2 rat hepatocellular carcinoma tumor models. METHODS AND MATERIALS Buffalo-McA-RH7777 and Sprague Dawley (SD)-N1S1 tumor models were used to evaluate tumor stiffness by 2-dimensional shear wave elastography, along with tumor perfusion by dynamic contrast-enhanced ultrasonography and contrast-enhanced computed tomography. Atomic force microscopy was used to calculate tumor stiffness at a submicron scale. Computer-aided image analyses were performed to evaluate tumor necrosis, as well as the percentage, distribution, and thickness of CD34+ blood vessels. RESULTS Distinct tissue signatures between models were observed according to the distribution of the stiffness values by 2-dimensional shear wave elastography and atomic force microscopy ( P < 0.05). Higher stiffness values were attributed to SD-N1S1 tumors, also associated with a scant microvascular network ( P ≤ 0.001). Opposite results were observed in the Buffalo-McA-RH7777 model, exhibiting lower stiffness values and richer tumor vasculature with predominantly peripheral distribution ( P = 0.03). Consistent with these findings, tumor enhancement was significantly greater in the Buffalo-McA-RH7777 tumor model than in the SD-N1S1 on both dynamic contrast-enhanced ultrasonography and contrast-enhanced computed tomography ( P < 0.005). A statistically significant positive correlation was observed between tumor perfusion on dynamic contrast-enhanced ultrasonography and contrast-enhanced computed tomography in terms of the total area under the curve and % microvessel tumor coverage ( P < 0.05). CONCLUSIONS The stiffness signatures translated into different tumor vascular phenotypes. Two-dimensional shear wave elastography and dynamic contrast-enhanced ultrasonography adequately depicted different stromal patterns, which resulted in unique imaging perfusion parameters with significantly greater contrast enhancement observed in softer tumors.
Collapse
Affiliation(s)
- Ryosuke Taiji
- From the Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX (R.T., A.C.C., M.W., C.D., R.A.); Department of Diagnostic and Interventional Radiology, Nara Medical University, Nara, Japan (R.T., T.T., H.N.); Cardiology Division, Department of Internal Medicine, UT Health Science Center at Houston, Houston, TX (A.M.Z.); Siemens Healthineers AG, Erlangen, Germany (G.C.); and Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, TX, (C.B.P.)
| | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Wang HP, Zheng PC, Wang XM, Sang L. Artifacts in two-dimensional shear wave elastography of liver. World J Gastroenterol 2023; 29:3318-3327. [PMID: 37377588 PMCID: PMC10292141 DOI: 10.3748/wjg.v29.i21.3318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 03/23/2023] [Accepted: 05/06/2023] [Indexed: 06/01/2023] Open
Abstract
BACKGROUND Artifacts are common when using two-dimensional shear wave elastography (2-D SWE) to measure liver stiffness (LS), but they are poorly recognized.
AIM To investigate the presence and influence of artifacts in 2-D SWE of liver.
METHODS We included 158 patients with chronic liver disease, who underwent 2-D SWE examination by a novice and an expert. A cross line at the center of the elastogram was drawn and was divided it into four locations: top-left, top-right, bottom-left, and bottom-right. The occurrence frequency of artifacts in different locations was compared. The influence of artifacts on the LS measurements was evaluated by comparing the elastogram with the most artifacts (EMA) and the elastogram with the least artifacts (ELA).
RESULTS The percentage of elastograms with artifacts in the novice (51.7%) was significantly higher than that of the expert (19.6%) (P < 0.001). It was found that both operators had the highest frequency of artifacts at bottom-left, followed by top-left and bottom-right, and top-right had the lowest frequency. The LS values (LSVs) and standard deviation values of EMAs were significantly higher than those of ELAs for both operators. An intraclass correlation coefficient value of 0.96 was found in the LSVs of EMAs of the two operators, and it increased to 0.98 when the LSVs of the ELAs were used. Both operators had lower stability index values for EMAs than ELAs, but the difference was only statistically significant for the novice.
CONCLUSION Artifacts are common when using 2-D SWE to measure LS, especially for the novice. Artifacts may lead to the overestimation of LS and reduce the repeatability and reliability of LS measurements.
Collapse
Affiliation(s)
- Hui-Peng Wang
- Department of Ultrasound, The First Hospital of China Medical University, Shenyang 110001, Liaoning Province, China
| | - Peng-Chao Zheng
- Department of Ultrasound, The First Hospital of China Medical University, Shenyang 110001, Liaoning Province, China
| | - Xue-Mei Wang
- Department of Ultrasound, The First Hospital of China Medical University, Shenyang 110001, Liaoning Province, China
| | - Liang Sang
- Department of Ultrasound, The First Hospital of China Medical University, Shenyang 110001, Liaoning Province, China
| |
Collapse
|
5
|
Nehring P, Szeligowska J, Przybyłkowski A. Elastography of the Liver in Wilson's Disease. Diagnostics (Basel) 2023; 13:diagnostics13111898. [PMID: 37296749 DOI: 10.3390/diagnostics13111898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 05/22/2023] [Accepted: 05/26/2023] [Indexed: 06/12/2023] Open
Abstract
Staging of liver fibrosis is of special significance in Wilson's disease as it determines the patient's prognosis and treatment. Histopathological examination is a standard method for fibrosis assessment; however, non-invasive methods like transient elastography and share wave elastography are believed to be reliable and repetitive and are expected to replace liver biopsy in Wilson's disease. This article presents a short description of available elastography techniques and the results of the most recent studies on elastography of the liver in patients with Wilson's disease.
Collapse
Affiliation(s)
- Piotr Nehring
- Department of Gastroenterology and Internal Medicine, Medical University of Warsaw, Banacha 1a, 02-097 Warsaw, Poland
| | - Jowita Szeligowska
- Department of Gastroenterology and Internal Medicine, Medical University of Warsaw, Banacha 1a, 02-097 Warsaw, Poland
| | - Adam Przybyłkowski
- Department of Gastroenterology and Internal Medicine, Medical University of Warsaw, Banacha 1a, 02-097 Warsaw, Poland
| |
Collapse
|
6
|
Gao J, Lee R, Trujillo M. Reliability of Performing Multiparametric Ultrasound in Adult Livers. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2022; 41:699-711. [PMID: 33982805 DOI: 10.1002/jum.15751] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Revised: 05/03/2021] [Accepted: 05/04/2021] [Indexed: 06/12/2023]
Abstract
PURPOSE The aim of the study was to test inter-observer and intra-observer reliability of measuring multiparametric ultrasound in adult livers. METHODS We prospectively measured shear wave velocity (SWV, m/s), shear wave dispersion slope (SWD, m/s/kHz), attenuation coefficient (ATI, dB/cm/MHz), normalized local variance (NLV), and echo intensity ratio of liver to kidney (L/K ratio) in 21 adults who underwent liver magnetic resonance imaging-proton density fat fraction (MRI-PDFF). Intraclass correlation coefficient and 95% Bland-Altman limits of agreement (95% LOA) were used to analyze intra- and inter-observer reproducibility. RESULTS Based on liver MRI-PDFF, 21 participants (8 men and 13 women, mean age 55 years) were divided into group 1 (11 normal livers, MRI-PDFF <5%) and group 2 (10 steatotic livers, MRI-PDFF ≥5%). ICCs for intra-observer repeatability and inter-observer reproducibility in measuring multiple ultrasound parameters in both normal and steatotic livers were above 0.75. However, 95% confidence interval for measuring SWD in all livers and L/K ratio in normal livers was 0.38-0.90 and 0.47-0.91, respectively. Differences in SWV, SWD, ATI, NLV, L/K ratio, and MRI-PDFF between participants with and without hepatic steatosis were significant (p < .05), whereas serum biomarkers and body mass index were not (p > .05), based on a two-tailed t-test. CONCLUSIONS The results suggest that the repeatability and reproducibility for measuring liver SWV, ATI, and NLV are moderate to excellent, while those for SWD and L/K ratio are poor. Standardized machine settings, scanning protocols, and operator training are suggested in performing multiparametric ultrasound of the liver.
Collapse
Affiliation(s)
- Jing Gao
- Rocky Vista University, Ivins, Utah, USA
| | | | | |
Collapse
|
7
|
Gao J, Wong C, Maar M, Park D. Reliability of performing ultrasound derived SWE and fat fraction in adult livers. Clin Imaging 2021; 80:424-429. [PMID: 34543866 DOI: 10.1016/j.clinimag.2021.08.025] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 08/10/2021] [Accepted: 08/30/2021] [Indexed: 12/18/2022]
Abstract
PURPOSE The aim of the study was to test the reproducibility of performing conventional point shear wave elastography (pSWE), auto-pSWE, and ultrasound derived fat fraction (UDFF) in adult livers. METHODS The Institutional Review Board approved the study and all participants provided written informed consent. Conventional pSWE (obtaining 10 measurements through 10 acquisitions), auto-pSWE (automatically obtaining 15 measurements by a single acquisition), and UDFF (one measurement obtained by one acquisition) of the liver were prospectively performed in 21 participants (10 men, 11 women, mean age 63y) by senior and junior operators in February-May 2021. Shear wave velocity (SWV, m/s) of the liver was measured by conventional pSWE and auto-pSWE. Intraclass correlation coefficient (ICC) and Bland-Altman limits of agreement were used to test intra-observer repeatability and inter-observer reproducibility in measuring pSWE, auto-pSWE, and UDFF. RESULTS ICC for testing intra-observer repeatability and inter-observer reproducibility in performing pSWE, auto-pSWE, and UDFF was >0.85 (95% confidence interval 0.85-0.99). The mean difference of 95% Bland-Altman limits of agreement was -0.02 (upper 0.09, lower -0.12) and the correlation of SWV measured between conventional pSWE and auto-pSWE methods was strong (r2 = 0.87). CONCLUSION Our results suggest good repeatability and reproducibility in measuring UDFF and SWV in adult livers. The auto-pSWE has higher reliability, reproducibility and time efficacy in measuring SWV of adult livers when compared to conventional pSWE method.
Collapse
Affiliation(s)
- Jing Gao
- Rocky Vista University, Ivins, UT, USA.
| | | | | | | |
Collapse
|
8
|
Kayadibi Y, Ucar N, Kaya MF, Yildirim E, Bektas S. Characterization of Suspicious Microcalcifications on Mammography Using 2D Shear-Wave Elastography. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2532-2542. [PMID: 34127332 DOI: 10.1016/j.ultrasmedbio.2021.05.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Revised: 04/27/2021] [Accepted: 05/06/2021] [Indexed: 06/12/2023]
Abstract
Our aim was to investigate the correlations between the findings of two-dimensional shear-wave elastography (2D-SWE) and the histopathologic results of microcalcifications (MCs) visualized using ultrasonography (USG). Fifty people with suspicious MCs without accompanying mass were evaluated. They underwent USG and 2D-SWE before USG-guided tru-cut biopsy. SWE values and histopathologic features were compared statistically. The variables between groups were analyzed using the Mann-Whitney U test. Receiver operating characteristic analysis was performed and cut-off values determined to discriminate malignancy, invasiveness and high grade. Pathology confirmed 27 malignant lesions (18 invasive ductal carcinomas, one invasive lobular and eight ductal carcinomas in situ) and 23 benign ones. There was a statistically significant difference between the SWE values of malignant and benign MCs (p < 0.001). The diagnostic performance of SWE for malignancy, invasiveness and high grade were as follows, repectively: sensitivity (93%, 83%, 88%), specificity (91%, 88%, 53%), positive predictive value (93%, 94%, 44%), negative predictive value (91%, 70%, 90%) and area under the curve (0.952, 0.885, 0.776). Cut-off values were determined as 57 kPa for malignancy, 124 kPa for invasiveness and 124.5 kPa for high grade. In conclusion, SWE is a useful method in clinical practice for characterizing MCs that can be visualized with USG.
Collapse
Affiliation(s)
- Yasemin Kayadibi
- Department of Radiology, Cerrahpasa Medical Faculty, Istanbul Universitesi-Cerrahpasa, Kocamustafapasa, Istanbul, Turkey.
| | - Nese Ucar
- Department of Radiology, Gaziosmanspasa Education and Research Hospital, Gaziosmanpasa, Istanbul, Turkey
| | - Mehmet Fatih Kaya
- Department of Radiology, Gaziosmanspasa Education and Research Hospital, Gaziosmanpasa, Istanbul, Turkey
| | - Emine Yildirim
- Department of General Surgery, Gaziosmanspasa Education and Research Hospital, Gaziosmanpasa, Istanbul, Turkey
| | - Sibel Bektas
- Department of Pathology, Gaziosmanspasa Education and Research Hospital, Gaziosmanpasa, Istanbul, Turkey
| |
Collapse
|
9
|
Dietrich CF, Shi L, Wei Q, Dong Y, Cui XW, Löwe A, Worni M, Ferraioli G. What does liver elastography measure? Technical aspects and methodology. Minerva Gastroenterol (Torino) 2020; 67:129-140. [PMID: 33267564 DOI: 10.23736/s2724-5985.20.02787-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Elastography can be thought as an extension of the ancient technique of palpation. After giving a short introduction to the history of elastography, the different technologies that are nowadays available and the physics behind them, the article focuses on the assessment of liver stiffness in patients with diffuse liver disease using shear wave elastography (SWE). Practical advices on how to perform the SWE techniques and on the factors that should be considered for a correct interpretation of the results are given. This paper aimed to provide a practical guide for beginners and advanced clinical users to better understand technical aspects, methodologies and terminology.
Collapse
Affiliation(s)
- Christoph F Dietrich
- Department Allgemeine Innere Medizin (DAIM), Kliniken Beau Site, Salem und Permanence, Hirslanden, Bern, Switzerland -
| | - Long Shi
- Department of Ultrasound, Jingmen N. 2 People's Hospital, Jingmen, China
| | - Qi Wei
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yi Dong
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xin-Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Axel Löwe
- Department Allgemeine Innere Medizin (DAIM), Kliniken Beau Site, Salem und Permanence, Hirslanden, Bern, Switzerland
| | - Mathias Worni
- Department of Visceral Surgery, Clarunis, University Center for Gastrointestinal and Liver Diseases, St. Clara University Hospital, Basel, Switzerland.,Swiss Institute for Translational and Entrepreneurial Medicine, Stiftung Lindenhof, Campus SLB, Bern, Switzerland.,Department of Surgery, Clinic Beau Site, Bern, Switzerland
| | - Giovanna Ferraioli
- Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia, Italy
| |
Collapse
|
10
|
Barr RG, Wilson SR, Rubens D, Garcia-Tsao G, Ferraioli G. Update to the Society of Radiologists in Ultrasound Liver Elastography Consensus Statement. Radiology 2020; 296:263-274. [PMID: 32515681 DOI: 10.1148/radiol.2020192437] [Citation(s) in RCA: 245] [Impact Index Per Article: 49.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
This multidisciplinary update of the Society of Radiologists in Ultrasound consensus statement on liver elastography incorporates the large volume of new information available in the literature since the initial publication. The recommended procedure for acquiring stiffness measurements is reviewed. There has been substantial improvement in the acoustic radiation force impulse (ARFI) technology-most notably the addition of a quality assessment of the shear wave propagation. Due to the efforts of the Quantitative Imaging Biomarkers Alliance, or QIBA, the variability of liver stiffness measurements between systems had decreased. There are now effective treatments for hepatitis B and hepatitis C, and follow-up after effective treatment should be based on the use of the delta change of the value obtained at viral eradication or suppression. Because the detection of compensated advanced chronic liver disease (cACLD) is very important, the new guidelines are made based on the probability of cACLD for given stiffness values. The panel recommends a vendor-neutral rule of four for interpretation for ARFI techniques. This new method simplifies interpretation of liver stiffness results and is more clinically relevant.
Collapse
Affiliation(s)
- Richard G Barr
- From the Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio (R.G.B.); Department of Radiology, University of Calgary, Calgary, Canada (S.R.W.); Departments of Imaging Science, Oncology, and Biomedical Engineering, University of Rochester Medical Center, Rochester, NY (D.R.); Section of Digestive Diseases, Department of Medicine, Yale University, New Haven, Conn (G.G.T.); and Ultrasound Unit, Department of Clinical Sciences and Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy (G.F.)
| | - Stephanie R Wilson
- From the Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio (R.G.B.); Department of Radiology, University of Calgary, Calgary, Canada (S.R.W.); Departments of Imaging Science, Oncology, and Biomedical Engineering, University of Rochester Medical Center, Rochester, NY (D.R.); Section of Digestive Diseases, Department of Medicine, Yale University, New Haven, Conn (G.G.T.); and Ultrasound Unit, Department of Clinical Sciences and Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy (G.F.)
| | - Deborah Rubens
- From the Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio (R.G.B.); Department of Radiology, University of Calgary, Calgary, Canada (S.R.W.); Departments of Imaging Science, Oncology, and Biomedical Engineering, University of Rochester Medical Center, Rochester, NY (D.R.); Section of Digestive Diseases, Department of Medicine, Yale University, New Haven, Conn (G.G.T.); and Ultrasound Unit, Department of Clinical Sciences and Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy (G.F.)
| | - Guadalupe Garcia-Tsao
- From the Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio (R.G.B.); Department of Radiology, University of Calgary, Calgary, Canada (S.R.W.); Departments of Imaging Science, Oncology, and Biomedical Engineering, University of Rochester Medical Center, Rochester, NY (D.R.); Section of Digestive Diseases, Department of Medicine, Yale University, New Haven, Conn (G.G.T.); and Ultrasound Unit, Department of Clinical Sciences and Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy (G.F.)
| | - Giovanna Ferraioli
- From the Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio (R.G.B.); Department of Radiology, University of Calgary, Calgary, Canada (S.R.W.); Departments of Imaging Science, Oncology, and Biomedical Engineering, University of Rochester Medical Center, Rochester, NY (D.R.); Section of Digestive Diseases, Department of Medicine, Yale University, New Haven, Conn (G.G.T.); and Ultrasound Unit, Department of Clinical Sciences and Infectious Diseases, Fondazione IRCCS Policlinico San Matteo, University of Pavia, Pavia, Italy (G.F.)
| |
Collapse
|
11
|
Naganuma H, Ishida H, Uno A, Nagai H, Kuroda H, Ogawa M. Diagnostic problems in two-dimensional shear wave elastography of the liver. World J Radiol 2020; 12:76-86. [PMID: 32549956 PMCID: PMC7288776 DOI: 10.4329/wjr.v12.i5.76] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 05/06/2020] [Accepted: 05/13/2020] [Indexed: 02/06/2023] Open
Abstract
Two-dimensional shear wave elastography (2D-SWE) is used in the clinical setting for observation of the liver. Unfortunately, a wide spectrum of artifactual images are frequently encountered in 2D-SWE, the precise mechanisms of which remain incompletely understood. This review was designed to present many of the artifactual images seen in 2D-SWE of the liver and to analyze them by computer simulation models that support clinical observations. Our computer simulations yielded the following suggestions: (1) When performing 2D-SWE in patients with chronic hepatic disease, especially liver cirrhosis, it is recommended to measure shear wave values through the least irregular hepatic surface; (2) The most useful 2D-SWE in patients with focal lesion will detect lesions that are poorly visible on B-mode ultrasound and will differentiate true tumors from pseudo-tumors (e.g., irregular fatty change); and (3) Measurement of shear wave values in the area posterior to a focal lesion must be avoided.
Collapse
Affiliation(s)
- Hiroko Naganuma
- Department of Gastroenterology, Yokote Municipal Hospital, Yokote 0138602, Akita, Japan
| | - Hideaki Ishida
- Department of Gastroenterology, Akita Red Cross Hospital, Kamikitatesaruta 0101495, Akita, Japan
| | - Atsushi Uno
- Department of Gastroenterology, Oomori Municipal Hospital, Yokote 0130525, Akita, Japan
| | - Hiroshi Nagai
- New Generation Imaging Laboratory, Tokyo 1680065, Japan
| | - Hidekatsu Kuroda
- Division of Gastroenterology and Hepatology, Iwate Medical University, Morioka 0200023, Iwate, Japan
| | - Masahiro Ogawa
- Department of Gastroenterology and Hepatology, Nihon University Hospital, Chiyoda 1018309, Tokyo, Japan
| |
Collapse
|