Case Report Open Access
Copyright ©The Author(s) 2018. Published by Baishideng Publishing Group Inc. All rights reserved.
World J Transplantation. Oct 22, 2018; 8(6): 232-236
Published online Oct 22, 2018. doi: 10.5500/wjt.v8.i6.232
Treatment of transplant renal artery pseudoaneurysm using expandable hydrogel coils: A case report and review of literature
Yazin Marie, Avneesh Kumar, Sarah Hinchliffe, Simon Curran, Badri Shrestha, Sheffield Kidney Institute, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield S5 7AU, United Kingdom
Peter Brown, Douglas Turner, Radiology Department, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield S5 7AU, United Kingdom
ORCID number: Badri Shrestha (0000-0002-7309-7080).
Author contributions: Marie Y and Shrestha B managed the patient and prepared the manuscript; Kumar A, Hinchliffe S and Curran S were involved in managing the patient and contributed to manuscript preparation; Brown P and Turner D performed radiological investigations, managed the patient and contributed to manuscript preparation.
Informed consent statement: The patient involved in this study gave his written informed consent authorizing use and disclosure of her protected health information.
Conflict-of-interest statement: All authors have no conflicts of interests to declare.
Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Correspondence to: Badri Shrestha, MD MS MPhil FRCS (Eng, Edin and Gen), FACS, FEBS Consultant Transplant Surgeon, Sheffield Kidney Institute, Sheffield Teaching Hospitals NHS Foundation Trust, Herries Road, Sheffield S5 7AU, United Kingdom. shresthabm@doctors.net.uk
Telephone: +44-11-42434343 Fax: +44-11-42714604
Received: March 9, 2018
Peer-review started: March 11, 2018
First decision: March 30, 2018
Revised: April 28, 2018
Accepted: October 8, 2018
Article in press: October 8, 2018
Published online: October 22, 2018
Processing time: 223 Days and 13.8 Hours

Abstract

Transplant renal artery (TRA) pseudoaneurysm can result in bleeding, infection, graft dysfunction and graft loss. We report the management of a renal transplant recipient who presented five months after renal transplantation with deterioration of renal function, who was found to have TRA pseudoaneurysm and TRA stenosis. Both were treated radiologically by using expandable hydrogel coils (EHC) in combination with stenting. Improvement in clinical, biochemical and radiological parameters were observed after the intervention. To our knowledge, this is the first report in the transplant literature on the use of EHC for the treatment of a TRA pseudoaneurysm.

Key Words: Pseudoaneurysm; Transplant renal artery; Expandable hydrogel coils; Outcomes

Core tip: Transplant renal artery (TRA) pseudoaneurysm is an uncommon complication after renal transplantation, which can cause transplant dysfunction, bleeding, infection and graft loss. Expandable hydrogel coils should be considered in the treatment of TRA pseudoaneurysm as they have been effective in our patient.



INTRODUCTION

Transplant renal artery (TRA) pseudoaneurysm can result in bleeding, infection, graft dysfunction, graft loss, lower limb ischaemia, limb loss and mortality[1]. The treatment of TRA pseudoaneurysm remains challenging. The expandable hydrogel coil (EHC) embolization system is a relatively new type of device that has been described to successfully treat intracranial and peripheral pseudoaneurysms. These are helical platinum coils coated with exapandable hydrogel polymer. The hydrogel coating undergoes full expansion within 20 min attending a size between 4-5 times the size of the coils on coming in contact with blood. The stasis of the blood causes organization of thrombus, which fills the aneurysm causing complete its occlusion[1]. To our knowledge, there is no published data in the transplant literature on the application of EHC in the treatment of TRA pseudoaneurysm. We describe the successful management of a case of TRA pseudoaneurysm using EHC and review the pertinent literature.

CASE REPORT

A 38-year-old male patient received a renal transplant (RT) of a kidney from a donation after circulatory death donor. The right donor kidney had a single real artery on an aortic patch and the short renal vein which was elongated by using a segment of inferior vena cava. The kidney was implanted in the right iliac fossa by anastomosing the renal artery to the external iliac artery in an end-to-side fashion using continuous 5/0 prolene sutures (Ethicon Inc., United Kingdom) and renal vein to the external iliac vein in the similar fashion. An extravesical ureteroneocystostomy was performed as describe by Lich-Gregoir. The vascular anastomosis time was 45 min while the total cold ischaemic time was 15 h and 38 min. The patient received basiliximab (Sandoz, United Kingdom) and methyl prednisolone as induction therapy and tacrolimus, mycophenolate mofetil and prednisolone as maintenance immunosuppression.

The transplant had delayed graft function and required haemodialysis during the first week until renal function started to improve. The initial ultrasound scan of the transplant kidney showed a well perfused graft with no evidence of hydronephrosis or any collection and the resistive indices (RI) were within normal limits. The renal function was stable with a serum creatinine of 136 μmol/L and an estimated glomerular filtration rate (eGFR) of 51 mL/min per 1.73 m2 at 3 mo post-transplantation.

At five months post-transplantation, on routine outpatient review, deterioration in kidney renal function with a rise in serum creatinine to 633 μmol/L (eGFR 13 mL/min per 1.73 m2) was observed. A duplex ultrasound scan showed a well-perfused kidney with no evidence of hydronephrosis. An ultrasound-guided biopsy of the kidney, which was treated with three pulses of intravenous methyl prednisolone, showed features of acute cellular rejection. However, there was no improvement in renal function. A repeat duplex ultrasound scan showed damped flow signals on the intra-renal blood vessels with reduced RI ranging between 0.4 and 0.45. There were associated high velocities at the transplant artery origin which were suspicious of TRA stenosis. A computerized tomography (CT) scan was done which showed a 20 mm × 25 mm pseudoaneurysm arising from the aortic patch and the TRA origin lying adjacent to the pseudoaneurysm was tightly narrowed (Figures 1 and 2). After discussion in the departmental multidisciplinary team meeting and with patient’s informed consent, he underwent radiological intervention as described below.

Figure 1
Figure 1 Computerized tomography angiogram showing a 20 mm x 25 mm pseudoaneurysm arising from the aortic patch (blue arrow).
Figure 2
Figure 2 Angiogram showing transplant renal artery stenosis (blue arrow) due to compression caused by the pseudoaneurysm. Guide wire is present within the right common and external iliac artery.

Under ultrasound guidance, the right common femoral artery was punctured, and a 5Fr sheath was inserted. 7500 unit of heparin was administered intravenously. The dimensions of the TRA were confirmed and were found to be like those of CT scan findings. The TRA was catheterized using a size 4Fr Berenstein® catheter and Terumo® wire (Terumo Medical Corporation, United States), subsequently exchanged for a 0.014 Thruway wire (Boston Scientific Inc., Ireland) and was left in situ as a “safety wire”. The left common femoral artery was punctured and a 6Fr destination sheath was placed over the aortic bifurcation. Through the ipsilateral 6Fr sheath, a 10 mm percutaneous transluminal angioplasty (PTA) balloon was placed opposite the aneurysm neck. From the 6Fr sheath, a 4Fr Cobra (Cook Medical, United States) and 2/7 Progreat® microcatheter (Terumo Medical Corporation, United States) were used to gain access to the aneurysm sac. Within the right external iliac artery, the PTA balloon was inflated to reduce the risk of coil prolapse and migration and the aneurysm was embolized using two Azur® 20 mm Framing coils (Terumo Medical Corporation, United States), and packed with Azur® Hydrogel Coils. The pseudoaneurysm was filled with coils and hydrogel leading to its complete occlusion. Subsequently, the stenosed transplant RA was stented using a 6 mm × 20 mm Hippocampus stent (Medtronic, United Kingdom), which restored the patency of the stenosed renal artery and normal blood flow (Figure 3).

Figure 3
Figure 3 Successful coiling of the pseudoaneurysm (red arrow) and stenting of the transplant renal artery stenosis (blue arrow).

Following embolization of the pseudoaneurysm and stenting of the TRA, improvement in renal function occurred leading to a fall in the serum creatinine level to 159 μmol/L (eGFR 47 mL/min per 1.73 m2). A follow-up CT angiogram one month after the intervention showed a patent TRA with successful coiling of the pseudoaneurysm and satisfactory position of the stent with no evidence of TRA stenosis. The patient continues to be followed up in the routine RT clinic and has a serum creatinine of 150 μmol/L (eGFR 49 mL/min per 1.73 m2).

DISCUSSION

Renal Transplantation remains the treatment of choice in end stage renal disease patients. Vascular complications after RT include TRA stenosis, TRA thrombosis, transplant renal vein thrombosis, arteriovenous fistula and TRA pseudoaneurysm[2]. TRA pseudoaneurysm is an uncommon complication and can be classified anatomically as intrarenal or extrarenal based on the involvement of either TRA or iliac artery, respectively. Aetiologically, TRA pseudoaneurysms can be of infective or non- infective origin. Infective pseudoaneurysms are more common and can be of fungal (mycotic) and non-fungal (non-mycotic) origin. Amongst the infective pseudoaneurysms, Candida albicans and Aspergillus species have been reported to be the predominant microorganisms, while Pseudomonas species were the leading cause of non-mycotic infective pseudoaneurysms[2-8]. Non-infective TRA pseudoaneurysms can result from injury to the arterial wall, faulty suture techniques[9-11] or following a biopsy[12,13].

TRA pseudoaneurysms can be asymptomatic[14] or can present with RT dysfunction, fever, pain (mainly at the site of the transplant) or a combination of these presentations. Graft loss is a recognized complication of TRA pseudoaneurysms and sometimes bleeding from the ruptured pseudoaneurysm can lead to hemorrhagic shock or death of the patient[8,15]. Lumbar plexopathy has been reported in a previous literature because of pressure effect of the pseudoaneurysm[16], while malignant hypertension is a rare presentation[17].

The choice of the modality of treatment of TRA pseudoaneurysms depends on several factors including the aetiology, haemodynamic stability of the patient, presentation, anatomy, graft function and the radiological features of the pseudoaneurysm[18-22]. Aneurysms larger than 25 mm, progressive enlargement, deterioration of renal function or presentation with symptoms are the main indications for repair[18]. Treatment modalities include minimally invasive techniques using mainly exclusion stents to the external iliac artery, but this may sacrifice the graft[14]. Ultrasound-guided percutaneous thrombin injection in combination with a covered stent has been reported as a successful way of treating TRA pseudoaneurysm with preservation of renal function[18,19].

Traditional aneurysm coiling in general can be associated with complications such as migration, non-target embolisation, inadequate filling, compaction and the technical difficulty in placing the coils leading to added risk to organs, patients and increase in cost[23].

Expandable hydrogel technology coils have been described to treat intracranial and peripheral pseudoaneurysms successfully for number of years. The main advantage of using EHC is related to their superior mechanical occlusion properties resulting in fewer coils deployed and a lower recurrence rate. They are also compatible with imaging modalities[24-26].

In our case, successful radiological and clinical outcomes were achieved with return of serum creatinine to baseline within 48 h of intervention without any complication related to the RT or lower limb. We have employed EHC system to treat TRA pseudoaneurysm, achieved excellent volumetric filling and targeted embolisation and subsequently deployed a stent leading to restoration of transplant renal function to its normality. It offers a new non- invasive technique to treat TRA pseudoaneurysms with preservation of renal grafts; therefore, it should be considered as a first line treatment modality in this clinical situation.

ARTICLE HIGHLIGHTS
Case characteristics

A 38-year-old male, who had received a deceased donor renal transplant presented with deterioration of renal function five months post-transplantation.

Clinical diagnosis

On examination, there were clinical features pointing to definitive diagnosis.

Differential diagnosis

Differential diagnosis included obstructive uropathy, acute rejection, infections, drug nephrotoxicity and transplant renal artery stenosis.

Laboratory diagnosis

The serum creatinine was significantly elevated.

Imaging diagnosis

The Duplex ultrasound scan showed reduced resistive index with high velocity flow in the renal artery suggestive of transplant renal artery stenosis. A computerized tomography angiogram showed a 20 mm × 25 mm pseudoaneurysm at the anastomosis site and stenosis of the transplant renal artery adjacent to the pseudoaneurysm.

Treatment

Endovascular embolisation of the pseudoaneurysm using expandable hydrogel coils (EHC) followed by deployment of stent lead to resolution of the pseudoaneurysm and transplant renal artery stenosis and restoration of renal function to normality.

Related reports

Follow-up of the patient was satisfactory with no adverse events related to the procedure.

Experiences and lessons

This is the first reported case of treatment of a transplant renal artery pseudoaneurysm with wide neck with the use of EHC leading to successful outcomes.

Footnotes

Manuscript source: Unsolicited manuscript

Specialty type: Transplantation

Country of origin: United Kingdom

Peer-review report classification

Grade A (Excellent): A

Grade B (Very good): B

Grade C (Good): 0

Grade D (Fair): 0

Grade E (Poor): 0

CARE Checklist (2013) statement: The authors have read the CARE Checklist (2013), and the manuscript was prepared and revised according to the CARE Checklist (2013).

P- Reviewer: Koukoulaki M, Popovic DD S- Editor: Ji FF L- Editor: A E- Editor: Huang Y

References
1.  Ding YH, Dai D, Lewis DA, Cloft HJ, Kallmes DF. Angiographic and histologic analysis of experimental aneurysms embolized with platinum coils, Matrix, and HydroCoil. AJNR Am J Neuroradiol. 2005;26:1757-1763.  [PubMed]  [DOI]  [Cited in This Article: ]
2.  Aktas S, Boyvat F, Sevmis S, Moray G, Karakayali H, Haberal M. Analysis of vascular complications after renal transplantation. Transplant Proc. 2011;43:557-561.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 57]  [Cited by in F6Publishing: 60]  [Article Influence: 4.6]  [Reference Citation Analysis (0)]
3.  Kountidou CS, Stier K, Niehues SM, Lingnau A, Schostak M, Fuller TF, Lützenberg R. Successful repair of post-transplant mycotic aneurysm of iliac artery with renal graft preservation: a case report. Urology. 2012;80:1151-1153.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 17]  [Cited by in F6Publishing: 20]  [Article Influence: 1.7]  [Reference Citation Analysis (0)]
4.  Minz M, Sharma A, Kumar S, Singh S, Shivaprakash MR, Bag S. Use of autogenous internal iliac artery for bridging the external iliac artery after excision of Aspergillus mycotic aneurysm in renal transplant recipients. J Vasc Surg. 2011;53:802-804.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 20]  [Cited by in F6Publishing: 22]  [Article Influence: 1.7]  [Reference Citation Analysis (0)]
5.  Smeds MR, Ofstein R, Peterson GJ, Peterson BG, Jacobs DL. Endovascular repair of a para-anastomotic pseudoaneurysm after renal autotransplantation: an alternative to open reconstruction. Ann Vasc Surg. 2013;27:110.e5-110.e8.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 10]  [Cited by in F6Publishing: 12]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
6.  Chandak P, Kessaris N, Uwechue RU, Abboudi H, Hossain M, Harris F, Jones K, Fronek J. Successful excision of a suspected mycotic transplant renal artery patch aneurysm with renal allograft autotransplantation. Transplantation. 2014;97:e25-e26.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 4]  [Cited by in F6Publishing: 6]  [Article Influence: 0.6]  [Reference Citation Analysis (1)]
7.  Orlando G, Di Cocco P, Gravante G, D’Angelo M, Famulari A, Pisani F. Fatal hemorrhage in two renal graft recipients with multi-drug resistant Pseudomonas aeruginosa infection. Transpl Infect Dis. 2009;11:442-447.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 30]  [Cited by in F6Publishing: 34]  [Article Influence: 2.3]  [Reference Citation Analysis (0)]
8.  Burkey SH, Vazquez MA, Valentine RJ. De novo renal artery aneurysm presenting 6 years after transplantation: a complication of recurrent arterial stenosis? J Vasc Surg. 2000;32:388-391.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 11]  [Cited by in F6Publishing: 13]  [Article Influence: 0.5]  [Reference Citation Analysis (0)]
9.  Nguan CY, Luke PP. Renal artery pseudoaneurysm of infectious etiology: a life-threatening complication after renal transplantation. Urology. 2006;68:668-669.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 12]  [Cited by in F6Publishing: 15]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
10.  Rivera M, Villacorta J, Jiménez-Alvaro S, Quereda C. Asymptomatic large extracapsular renal pseudoaneurysm following kidney transplant biopsy. Am J Kidney Dis. 2011;57:175-178.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 11]  [Cited by in F6Publishing: 14]  [Article Influence: 1.1]  [Reference Citation Analysis (0)]
11.  Duwe KM, Newhouse JH, Fayter J, Stern L, Budorick NE. Conservative management of an extrarenal pseudoaneurysm after percutaneous needle biopsy of a renal allograft. J Ultrasound Med. 2000;19:281-283.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 7]  [Cited by in F6Publishing: 8]  [Article Influence: 0.3]  [Reference Citation Analysis (0)]
12.  Antonopoulos IM, Yamacake KG, Tiseo BC, Carnevale FC, Z E Jr, Nahas WC. Renal pseudoaneurysm after core-needle biopsy of renal allograft successfully managed with superselective embolization. Int Braz J Urol. 2016;42:165-167.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 4]  [Cited by in F6Publishing: 4]  [Article Influence: 0.6]  [Reference Citation Analysis (0)]
13.  Patrono D, Verhelst R, Buemi A, Darius T, Godefroid N, Mourad M. Presentation and management of mycotic pseudoaneurysm after kidney transplantation. Transpl Infect Dis. 2015;17:129-136.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 12]  [Cited by in F6Publishing: 14]  [Article Influence: 1.6]  [Reference Citation Analysis (0)]
14.  Orlic P, Vukas D, Drescik I, Ivancic A, Blecic G, Budiselic B, Velcic G, Maricic A, Oguic R, Mozetic V. Vascular complications after 725 kidney transplantations during 3 decades. Transplant Proc. 2003;35:1381-1384.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 42]  [Cited by in F6Publishing: 45]  [Article Influence: 2.1]  [Reference Citation Analysis (0)]
15.  Luzzio CC, Waclawik AJ, Gallagher CL, Knechtle SJ. Iliac artery pseudoaneurysm following renal transplantation presenting as lumbosacral plexopathy. Transplantation. 1999;67:1077-1078.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 37]  [Cited by in F6Publishing: 38]  [Article Influence: 1.5]  [Reference Citation Analysis (0)]
16.  Madhav D, Kumar P, Mohan C; Vijay, Mahesh U; Anusha; Suneetha; Suryaprakash. Candida-associated pseudo-aneurysm of the transplant renal artery presenting as malignant hypertension and managed successfully without nephrectomy. Saudi J Kidney Dis Transpl. 2015;26:1000-1005.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 7]  [Cited by in F6Publishing: 8]  [Article Influence: 0.9]  [Reference Citation Analysis (0)]
17.  Bracale UM, Santangelo M, Carbone F, Del Guercio L, Maurea S, Porcellini M, Bracale G. Anastomotic pseudoaneurysm complicating renal transplantation: treatment options. Eur J Vasc Endovasc Surg. 2010;39:565-568.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 36]  [Cited by in F6Publishing: 39]  [Article Influence: 2.8]  [Reference Citation Analysis (0)]
18.  Asztalos L, Olvasztó S, Fedor R, Szabó L, Balázs G, Lukács G. Renal artery aneurysm at the anastomosis after kidney transplantation. Transplant Proc. 2006;38:2915-2918.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 20]  [Cited by in F6Publishing: 15]  [Article Influence: 0.9]  [Reference Citation Analysis (0)]
19.  Zavos G, Pappas P, Kakisis JD, Leonardou P, Manoli E, Bokos J, Kostakis A. Endovascular repair as first-choice treatment of iliac pseudoaneurysms following renal transplantation. Transplant Proc. 2005;37:4300-4302.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 35]  [Cited by in F6Publishing: 36]  [Article Influence: 2.0]  [Reference Citation Analysis (0)]
20.  Kubal C, Cacciola R, Riley P, Ready A. Internal iliac artery pseudoaneurysm following renal transplant biopsy successfully treated with endovascular stenting and thrombosis: a case report. Transplant Proc. 2007;39:1676-1678.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 10]  [Cited by in F6Publishing: 7]  [Article Influence: 0.4]  [Reference Citation Analysis (0)]
21.  Dimitroulis D, Bokos J, Zavos G, Nikiteas N, Karidis NP, Katsaronis P, Kostakis A. Vascular complications in renal transplantation: a single-center experience in 1367 renal transplantations and review of the literature. Transplant Proc. 2009;41:1609-1614.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 112]  [Cited by in F6Publishing: 112]  [Article Influence: 7.5]  [Reference Citation Analysis (0)]
22.  Sharron JA, Esterl RM, Washburn WK, Abrahamian GA. Surgical treatment of an extrarenal pseudoaneurysm after kidney transplantation. Vasc Endovascular Surg. 2009;43:317-321.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 6]  [Cited by in F6Publishing: 8]  [Article Influence: 0.5]  [Reference Citation Analysis (0)]
23.  Sluzewski M, van Rooij WJ, Slob MJ, Bescós JO, Slump CH, Wijnalda D. Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils. Radiology. 2004;231:653-658.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 286]  [Cited by in F6Publishing: 270]  [Article Influence: 13.5]  [Reference Citation Analysis (0)]
24.  Kallmes DF, Fujiwara NH. New expandable hydrogel-platinum coil hybrid device for aneurysm embolization. AJNR Am J Neuroradiol. 2002;23:1580-1588.  [PubMed]  [DOI]  [Cited in This Article: ]
25.  Deshaies EM, Adamo MA, Boulos AS. A prospective single-center analysis of the safety and efficacy of the hydrocoil embolization system for the treatment of intracranial aneurysms. J Neurosurg. 2007;106:226-233.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 52]  [Cited by in F6Publishing: 58]  [Article Influence: 3.4]  [Reference Citation Analysis (0)]
26.  White PM, Lewis SC, Nahser H, Sellar RJ, Goddard T, Gholkar A; HELPS Trial Collaboration. HydroCoil Endovascular Aneurysm Occlusion and Packing Study (HELPS trial): procedural safety and operator-assessed efficacy results. AJNR Am J Neuroradiol. 2008;29:217-223.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 113]  [Cited by in F6Publishing: 111]  [Article Influence: 6.9]  [Reference Citation Analysis (0)]