Copyright
©The Author(s) 2024.
World J Transplant. Sep 18, 2024; 14(3): 95233
Published online Sep 18, 2024. doi: 10.5500/wjt.v14.i3.95233
Published online Sep 18, 2024. doi: 10.5500/wjt.v14.i3.95233
Figure 1 Creatinine clearance (cc/s) for paired kidneys transplanted first (kidney 1 group) and second (kidney 2 group, with longer hypothermic machine perfusion time) at various time points post-transplant.
There was no significant difference in creatinine clearance at any of the time points. Students paired t-test was used for these comparisons.
Figure 2 Freedom from biopsy-proven acute rejection in the first year for paired kidneys transplanted first (kidney 1 group) and second (kidney 2 group, with longer hypothermic machine perfusion time).
Kaplan-Meier analysis was used (P = 0.0147).
Figure 3 Graft failure for paired kidneys transplanted first (kidney 1 group) and second (kidney 2 group, with longer hypothermic machine perfusion time).
Kaplan-Meier analysis was used (P = 0.0228).
- Citation: Verdiales C, Baxter L, Lim HJ, Beck G, Moser MA. Matched pair analysis of the effect of longer hypothermic machine perfusion time on kidney transplant outcomes. World J Transplant 2024; 14(3): 95233
- URL: https://www.wjgnet.com/2220-3230/full/v14/i3/95233.htm
- DOI: https://dx.doi.org/10.5500/wjt.v14.i3.95233