Randomized Clinical Trial Open Access
Copyright ©The Author(s) 2024. Published by Baishideng Publishing Group Inc. All rights reserved.
World J Psychiatry. Sep 19, 2024; 14(9): 1375-1385
Published online Sep 19, 2024. doi: 10.5498/wjp.v14.i9.1375
Effect of quantitative consciousness index on seizure parameters during electroconvulsive therapy in patients with major depressive disorder
Bang-Shu Zhao, Qi-Bin Chen, Su Min, Department of Anesthesiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
Bi Deng, You Yang, Department of Anesthesiology, The First Clinical College of Chongqing Medical University, Chongqing 400016, China
Xiao Li, Department of Psychiatry, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China
ORCID number: Bang-Shu Zhao (0009-0005-9113-3873); Su Min (0009-0006-1931-9945).
Author contributions: Zhao BS prepared the manuscript for publication and contributed to the study design, data collection, and analysis; Deng B and Yang Y contributed to the statistical analysis and preparation of the tables and figures; Li X contributed to the electroshock therapy, psychiatric assessment, and electroencephalography analysis; Chen QB administered anesthesia in clinical practice; Min S contributed to the study design and analysis. All authors revised and approved the final version of the manuscript.
Supported by the National Natural Science Foundation of China, No. 81873798 and No. 81901377; and Chongqing Science and Technology Bureau Under Grant, No. cstc2019jcyj-msxmX0839.
Institutional review board statement: The research was approved by the Ethics Committee of the First Affiliated Hospital of Chongqing Medical University, batch number: 2023 Scientific Research Ethics (2023-052).
Clinical trial registration statement: The study was registered on the official website of clinical trials (https://clinicaltrials.gov, ID: NCT05900245).
Informed consent statement: All participants provided informed consent before participating in the study.
Conflict-of-interest statement: All the authors report no relevant conflicts of interest for this article.
Data sharing statement: The data used in this study can be obtained from the corresponding author upon request.
CONSORT 2010 statement: The authors have read the CONSORT 2010 Statement, and the manuscript was prepared and revised according to the CONSORT 2010 Statement.
Open-Access: This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/
Corresponding author: Su Min, MBBS, Professor, Department of Anesthesiology, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuzhong District, Chongqing 400016, China. ms89011068@163.com
Received: July 15, 2024
Revised: August 18, 2024
Accepted: August 28, 2024
Published online: September 19, 2024
Processing time: 57 Days and 19.5 Hours

Abstract
BACKGROUND

Electroconvulsive therapy (ECT) is both an effective treatment for patients with major depressive disorder (MDD) and a noxious stimulus. Although some studies have explored the effect of sedation depth on seizure parameters in ECT, there is little research on the noxious stimulation response to ECT. In this study, we used two electroencephalography (EEG)-derived indices, the quantitative consciousness (qCON) index and quantitative nociceptive (qNOX) index, to monitor sedation, hypnosis, and noxious stimulation response in patients with MDD undergoing acute ECT.

AIM

To evaluate the effect of anesthesia depth based on the qCON and qNOX indices on seizure parameters.

METHODS

Patients with MDD (n = 24) underwent acute bilateral temporal ECT under propofol anesthesia. Before ECT, the patients were randomly divided into three groups according to qCON scores (qCON60-70, qCON50-60, and qCON40-50). Continuous qCON monitoring was performed 3 minutes before and during ECT, and the qCON, qNOX, vital signs, EEG seizure parameters, and complications during the recovery period were recorded. The 24-item Hamilton Rating Scale for Depression, Zung’s Self-rating Depression Scale, and Montreal Cognitive Assessment scores were evaluated before the first ECT session, after the fourth ECT session, and after the full course of ECT.

RESULTS

A total of 193 ECT sessions were performed on 24 participants. The qCON index significantly affected the EEG seizure duration, peak mid-ictal amplitude, and maximum heart rate during ECT (P < 0.05). The qNOX index significantly affected the post-ictal suppression index (P < 0.05). Age, number of ECT sessions, and anesthetic-ECT time intervals also had a significant effect on EEG seizure parameters (P < 0.05). However, there were no significant differences in complications, 24-item Hamilton Rating Scale for Depression scores, Zung’s Self-rating Depression Scale scores, or Montreal Cognitive Assessment scores among the three groups (P > 0.05).

CONCLUSION

Electrical stimulation at a qCON index of 60-70 resulted in better EEG seizure parameters without increasing complications in patients with MDD undergoing bilateral temporal ECT under propofol anesthesia.

Key Words: Electroconvulsive therapy; Propofol; Nociception; Depression; Electroencephalogram

Core Tip: Anesthesia depth based on quantitative consciousness index and quantitative nociceptive index affects electroconvulsive therapy (ECT) seizure parameters during acute ECT in patients with major depressive disorder. Electrical stimulation at a quantitative consciousness index of 60-70 will improve electroencephalography seizure parameters while not increasing complications. The quantitative nociceptive index had a significant effect on post-ictal suppression index, and patients with higher post-ictal suppression index may suffer from greater noxious stimulation during ECT. We should not only consider the effect of sedation depth on the quality of seizure but also the degree of noxious stimulation brought by the treatment technology itself during ECT.



INTRODUCTION

Depression is a common clinical mental illness characterized by high incidence, recurrence rate, suicide rate, and disability rate[1-3]. As a first-line treatment for treatment-resistant depression with a high risk of suicide and obvious psychiatric symptoms, electroconvulsive therapy (ECT) has been shown to have a definite therapeutic effect on depression[4-7]. Whether the mechanism of action for ECT on mental diseases can be contributed to the effect of seizures, electric currents on the brain alone, or their combined effects is not yet known[8,9]. Nonetheless, extensive epileptic discharge into the cerebral cortex is necessary to ensure ECT[10-13].

The quality of seizures can be continuously evaluated using electroencephalography (EEG) parameters such as EEG seizure duration, peak mid-ictal amplitude, post-ictal suppression index (PSI), coherence, and maximum heart rate during ECT[14,15]. There are differences in seizure thresholds among patients. The quality of seizures in ECT is affected by patient factors, treatment techniques, and anesthesia, including age, sex, previous ECT history, benzodiazepine medication, electrode position, pulse width, electrical dose, ECT treatment sessions, anesthetic drugs, and anesthesia depth[16-18]. Most anesthetics, such as barbiturates or propofol, have anticonvulsant properties, which have a negative impact on the quality of seizures and may affect the antidepressant effect[19-21]. Modifying the parameters of ECT, such as stimulus intensity, can improve the quality of seizures, but may also lead to higher cognitive side effects[13,22]. The depth of anesthesia also affects seizure quality in ECT, and seizure quality is higher under light anesthesia[23]. However, if anesthetic drugs are reduced to improve the quality of seizures, patients may be at risk of awareness, especially during the positioning of unilateral non-dominant electrodes[24].

To determine the appropriate anesthesia depth for ECT, anesthesiologists use anesthesia depth monitoring equipment [such as bispectral index (BIS) and Narcotrend] to guide anesthesia for ECT[25-29]. However, the EEG indices contained in the BIS and Narcotrend can only evaluate the sedative and hypnotic effects of anesthesia rather than the nociceptive stimulus response during general anesthesia[30-33], and all of them are affected by age and body temperature[34-36]. Currently, the observation of nociceptive stimulus responses is mainly based on heart rate variability (HRV), skin conductance (SC), a combination of HRV and SC parameters, changes in pupil size, or other parameters of HRV-derived parasympathetic nerve activity[37-43]. However, brain signal analysis methods based on EEG are usually empirical, because there is no clear consensus on the characteristics of EEG changes in the process of nociceptive stimulus response. Monitoring the quantitative consciousness (qCON) index (also known as the index of consciousness, IoC1) and the quantitative nociceptive (qNOX) index (also known as the pain index, IoC2) is a relatively new method based on dynamic EEG to monitor anesthesia depth. It uses an adaptive neuro-fuzzy inference system and non-linear analysis to calculate a value between 0 and 99, independent of the autonomic nerve activity. The qCON index is similar to the BIS and Narcotrend indices, which mainly reflect the depths of sedation and hypnosis. A qCON of 80-99 represents wakefulness, 60-79 represents sedation or light anesthesia, 40-60 represents appropriate anesthesia depth, and < 40 represents deep anesthesia[44]. The qNOX index reflects the degree of nociceptive stimulus response; the higher the qNOX index, the higher the nociceptive stimulus response. The qCON index combined with the qNOX index has been widely used to monitor anesthesia depth under general anesthesia, and they are considered to be well correlated with the BIS index for monitoring of sedative hypnosis depth[32-33,44-47], while their usefulness for monitoring nociceptive stimulus response has limited confirmation[48-50]. As ECT is both a therapeutic method and noxious stimulus for patients[51,52], it seems that a combination of the qCON and qNOX indices is appropriate for monitoring the depth of anesthesia during ECT. However, to the best of our knowledge, no such study has been conducted.

Therefore, in this study, the qCON and qNOX indices were combined to monitor the anesthesia depth during ECT, and the primary aim was to evaluate the effect of different anesthesia depths on EEG seizure parameters in patients with major depressive disorder (MDD) undergoing ECT. We hypothesized that light anesthesia would achieve better EEG seizure parameters. As a secondary objective, we evaluated the relationship between the qNOX index and EEG seizure parameters. We also evaluated adverse events during the recovery period and the clinical effects on patients with MDD after ECT under different anesthesia depths.

MATERIALS AND METHODS
Sample and study design

Participants were recruited from among psychiatric inpatients at the First Affiliated Hospital of Chongqing Medical University from June 12, 2023 to December 15, 2023. Although the view that EEG seizure duration is the main determinant of the treatment effect is changing, an EEG seizure duration < 25 seconds is still considered insufficient in the treatment of depression[53], and a motor duration < 15 seconds can lead to insufficient treatment[54]. Therefore, the sample size calculation in this study considers EEG seizure duration as the main goal. According to Kranaster et al[55], the correlation coefficient between anesthesia depth and EEG seizure duration was 0.26, assuming that qCON and BIS monitoring can also reflect anesthesia depth, and assuming the test is a bilateral test with an α of 0.05 and assurance (1-β) of 0.8. In one course of ECT, there are an average of eight sessions. The correlation coefficient for this group was 0.5. The participants were randomly divided into three groups before ECT: Group 1, with a qCON of 60-70, group 2, with a qCON of 50-60, and group 3, with a qCON of 40-50. A sample size of sufficient power was estimated to be 21 patients, and the required sample size for enrollment was estimated to be 24 patients, considering a 10% loss before the completion of the study.

Inclusion criteria: (1) Inpatients who met the diagnostic criteria for MDD in the 11th edition of the International Classification of Diseases; (2) Age 18-60 years; (3) Primary school education or above; (4) A 24-item Hamilton Depression Rating Scale (HAM-D) scores of ≥ 35 points; (5) Indications for ECT; (6) Normal hearing and vision (including color discrimination ability); and (7) Voluntary agreement to participate in this study and sign informed consent forms, while their guardians signed informed consent forms simultaneously. Exclusion criteria: (1) Presence of comorbid physical diseases, organic brain diseases, other mental diseases, or a history of alcohol or psychoactive substance abuse; (2) Primary insomnia; and (3) Pregnant and lactating women.

Randomisation and masking

In this study, a computer randomization method was used. First, the participants were numbered in sequence, and random numbers were generated using SPSS 26 software (IBM, Armonk, NY, United States). The random numbers were ranked and sorted. According to the order, the participants were randomly divided into three groups: qCON 60-70, qCON 50-60, and qCON 40-50. The participants’ groupings were placed in 24 envelopes and maintained by a nurse anesthetist who was not involved with the treatment. Because anesthesiologists must decide the timing of electrical stimulation according to the qCON index in this study, a single-blind method was adopted. The participants and data collectors were blinded to the grouping situation.

Anesthesia and ECT procedures

A Thymatron System IV (Somatics LLC, Venice, FL) device was used as the ECT device. All the participants were placed with a traditional bilateral temporal stimulation electrode (short pulse: 0.5 ms; stimulation mode: DGX). The stimulus intensity was based on age; that is, the power was set to 50% of age. The dose was adjusted according to EEG seizure parameters and clinical reactions of the patients, which were determined by psychiatrists. A two-channel EEG with electrodes at the Fp1 and Fp2 sites was used to determine the length and characteristics of the EEG seizures. None of the participants stopped using antidepressants before ECT. All participants had fasted for 8 hours and been deprived of water for 2 hours. Continuous qCON monitoring (Apollo-9000A, Chongqing Xider Medical Instrument Co., Chongqing, China) was performed 3 minutes before and during ECT. Blood pressure, heart rate, and pulse oxygen saturation were monitored simultaneously, and oxygen was administered for 3 minutes in advance. qCON monitoring uses three electrodes to collect the original EEG signals from the forehead. Monitoring included qCON, qNOX, burst suppression, and signal quality index. All participants were anesthetized by the intravenous administration of propofol (1.5 mg/kg; AstraZeneca, Oxford, United Kingdom; concentration: 10 mg/mL) for 30 seconds. After propofol injection, the anesthesiologist continuously referred to the patient’s name. When the patient was confirmed to have no response and the eyelash reflex disappeared, the patient was injected with succinylcholine (1 mg/kg; Shanghai Xudong Haipu Pharmaceutical Co., Shanghai, China, concentration: 2 mL/0.1 g) for muscle relaxation and was given mask ventilation. After propofol injection, the qCON index first rapidly decreased and then slowly rebounded. According to the grouping of participants, electrical stimulation was performed when the qCON index rose to the corresponding range. If the patient still had consciousness or eyelash reflex after receiving 1.5 mg/kg of propofol, anesthesiologists increased the dose of propofol. After the seizure, mask ventilation was continued until the patient recovered from the anesthesia.

During the treatment period, blood pressure, heart rate, pulse oxygen saturation, time intervals (the interval between anesthesia induction and electrical stimulation), dose of anesthetic drugs, qCON index, qNOX index, burst suppression, signal quality index, EEG seizure parameters, recovery time (from the end of the seizure to eye opening), and complications during the recovery period were recorded. The 24-item HAM-D, Zung’s Self-rating Depression Scale (SDS), and Montreal Cognitive Assessment (MoCA) scores of each subject were evaluated 24 hours before the first ECT, 24 hours after the fourth ECT, and 24 hours after the full course of ECT. The 24-item HAM-D and MoCA scores were evaluated by psychiatrists, and SDS scores were scored by the participants themselves.

Statistical analysis

All statistical analyses were performed using SPSS 26 software (IBM). All measurement data were subjected to Shapiro-Wilk normality tests and represented by mean ± SD, if normally distributed or median and interquartile range if not. The demographic data (age, height, and weight), respiratory and circulatory indexes (blood pressure, heart rate, and pulse oxygen saturation) at baseline before ECT, and 24-item HAM-D, SDS, and MoCA scores at the time of the treatment session were analyzed by one-way analysis of variance (ANOVA). Multiple comparisons were used for comparisons between groups, and the Kruskal-Wallis test was used for non-normally distributed data. A generalized linear mixed-effect model was used to analyze the effects of patient, treatment, and anesthesia factors on EEG seizure parameters. The repeated measurements were the treatment sessions of ECT, the covariance structure was a first-order autoregressive structure (AR1), and the fixed effect included a random intercept. Based on the qCON index, the anesthesia depth was divided into three levels. With anesthesia depth as an independent variable and the same covariance structure, the effect of anesthesia depth on EEG seizure parameters was analyzed using a single generalized mixed-effect model. The clinical effect of ECT (24-item HAM-D scores, SDS scores, and MoCA scores) was evaluated using repeated-measures ANOVA. Adverse events during the recovery period were analyzed using Fisher’s exact test. The statistical significance test was a double-tailed test; significance was set at P < 0.05, and the Bonferroni correction was used for multiple comparisons between groups.

RESULTS
Characteristics of patients

A total of 193 ECT sessions performed on 24 participants were available for analysis. In the 193 ECT treatment sessions, no patients received additional doses of propofol, and the dose of propofol was 1.5 mg/kg in all patients. The baseline demographic and clinical characteristics of the enrolled patients did not differ among the three groups (Table 1).

Table 1 Demographic data, Hamilton Depression Rating Scale score, Zung’s Self-rating Depression Scale score, Montreal Cognitive Assessment score, and cardiorespiratory findings of three groups of patients.
CharacteristicsGroup 1: qCON 60-70
Group 2: qCON 50-60
Group 3: qCON40-50
Age, years32.3 ± 14.233.9 ± 15.031.9 ± 13.6
Male2/81/81/8
Weight, kg55.6 ± 7.055.9 ± 13.657.8 ± 15.5
Height, cm162.3 ± 9.1162.1 ± 9.9164.9 ± 5.9
Propofol dose, mg (IQR)85.5 (72.0, 88.5)87.0 (70.5, 100.5)85.5 (66.0, 105.0)
Succinylcholine dose, mg (IQR)57.0 (48.0, 59.0)58.0 (47.0, 67.0)57.0 (44.0, 70.0)
Interventions, median (IQR)8 (7, 9)8 (6.5, 10)8 (7.5, 8)
Baseline HAMD-24 score42.8 ± 4.441.3 ± 4.442.3 ± 4.0
HAMD-24 score after fourth ECT21.0 ± 4.422.4 ± 5.927.9 ± 7.7
HAMD-24 score after full ECT course12.3 ± 4.713.3 ± 5.117.0 ± 6.0
Baseline SDS score69.2 ± 7.465.8 ± 6.767.8 ± 6.0
SDS score after fourth ECT57.7 ± 7.956.1 ± 11.660.3 ± 5.3
SDS score after full ECT course49.7 ± 3.949.7 ± 5.754.4 ± 5.4
Baseline MoCA score24.8 ± 2.625.1 ± 2.924.9 ± 2.9
MoCA score after fourth ECT22.6 ± 2.123.5 ± 3.322.6 ± 3.1
MoCA score after full ECT course23.4 ± 1.724.4 ± 2.924.1 ± 2.5
Cardiorespiratory data
Baseline heart rate, bpm89.0 ± 9.887.0 ± 16.884.3 ± 19.3
Baseline systolic blood pressure, mmHg118.9 ± 14.1113.5 ± 14.0112.1 ± 11.3
Baseline diastolic blood pressure, mmHg74.4 ± 8.874.3 ± 11.370.0 ± 7.1
Baseline peripheral oxygen saturation, %96.8 ± 1.497.3 ± 1.297.3 ± 1.2
Clinical factors on EEG seizure parameters

The qCON index significantly affected the EEG seizure duration, peak mid-ictal amplitude, and maximum heart rate during ECT (P < 0.05). The higher the qCON index during electrical stimulation, the longer the EEG seizure duration, the larger the median amplitude, and the higher the maximum heart rate during ECT. qNOX index had a more significant effect on PSI (P < 0.05); the higher the qNOX index, the higher the PSI. Age significantly affected the EEG seizure duration and recovery time of patients (P < 0.05). The older the age, the shorter the EEG seizure duration and the longer the recovery time. The number of ECT had significant effects on the EEG seizure duration, average seizure energy index (ASEI), and PSI (P < 0.05). The longer the treatment sessions, the shorter the EEG seizure duration, the lower the ASEI, and the lower the PSI. The anesthetic-ECT time intervals also had a significant effect on the EEG seizure duration and PSI (P < 0.05); the longer the anesthetic-ECT time intervals, the longer the EEG seizure duration, and the higher the PSI, while the charge dose had no significant effect on the seizure parameters (Table 2).

Table 2 Generalized linear mixed model examining effect of treatment, patient, and anesthesia factors on electroencephalography seizure parameters.
Covariate/dependentEEG endpoint (s)
ASEI (μV2)
PSI (%)
Mid-ictal amplitude (μV)
Coherence (%)
Maximum heart rate, (bpm)
Recovery time (min)
Est
SE
P value
Est
SE
P value
Est
SE
P value
Est
SE
P value
Est
SE
P value
Est
SE
P value
Est
SE
P value
qCON0.3390.1600.036a34.150140.5260.8080.0570.0950.5530.5310.2320.023a0.0960.0620.1250.3310.1400.019a-0.0170.0390.664
qNOX-0.0110.1160.922-2.927116.1960.9800.1620.0790.042a0.2160.1910.2590.0010.0510.9880.0610.1140.5930.0220.0290.457
Age (years)-0.5970.2130.006a142.87994.2140.131-0.0790.0630.211-0.0640.1620.6930.0340.0460.4560.0910.1040.3840.0960.0460.039a
ECT number--0.000a--0.000a--0.024a--0.418--0.158--0.128--0.266
Charge, mC0.0680.6670.307-32.53930.4520.2870.0140.0200.4910.0320.0520.545-0.0070.0150.647-0.0240.0340.4830.0020.0150.888
Anesthetic-ECT time, interval (min)0.1570.0480.001a-17.20743.9830.6960.0720.0300.018a0.0410.0730.5750.0070.0200.7240.0740.0440.093-0.0010.0120.922
Anesthesia depth on EEG seizure parameters

The effect of anesthesia depth on EEG seizure parameters was analyzed using a generalized mixed-effects model alone. The results showed that anesthesia depth significantly affected the maximum heart rate, EEG seizure duration, PSI, peak mid-ictal amplitude and coherence during ECT (P < 0.05); the lighter the anesthesia, the higher the maximum heart rate, the longer the EEG seizure duration, the larger the median amplitude, the higher the PSI, and the higher the coherence. However, this had no significant effect on ASEI or recovery time (Table 3).

Table 3 The effect of anesthesia depth on electroencephalography seizure parameters: Findings of generalized linear mixed model analyses.
Characteristics (dependent variable)
F value
P value
Maximum heart rate3.4600.034a
EEG endpoint3.3260.038a
ASEI0.2360.790
PSI7.0410.001a
Mid-ictal amplitude5.7170.004a
Coherence3.3640.037a
Maximum systolic blood pressure1.4900.228
Maximum diastolic blood pressure0.3750.688
Recovery time after treatment0.0950.909
Clinical effects and adverse events

There were no significant differences in the 24-item HAM-D, SDS, and MoCA scores (Figure 1) before and after ECT or in complications during the recovery period among the three groups (Table 4).

Figure 1
Figure 1 Comparison of clinical effects of electroconvulsive therapy among three groups of patients (n = 24). A: Comparison of 24-item Hamilton Depression Rating Scale score changes before and after electroconvulsive therapy (ECT) among three groups of patients (P = 0.188); B: Comparison of Zung’s Self-rating Depression Scale score changes before and after ECT among three groups of patients (P = 0.214); C: Comparison of Montreal Cognitive Assessment score changes before and after ECT among three groups of patients (P = 0.920). ECT: Electroconvulsive therapy; HAM-D: Hamilton Depression Rating Scale; SDS: Zung’s Self-rating Depression Scale; MoCA: Montreal Cognitive Assessment.
Table 4 Adverse events reported by participants during anesthesia recovery period: Findings of Fisher’s precision probability test, n (%).
Adverse event
Group 11
Group 22
Group 33
χ²
P value
Headache5 (7.9)7 (10.8)4 (6.2)0.9260.629
Dizziness3 (4.8)6 (9.2)3 (4.6)1.4040.603
Nausea/vomiting3 (4.8)6 (9.2)4 (6.2)1.0410.677
Muscle soreness6 (9.5)5 (7.7)4 (6.2)0.5080.776
Delirium0 (0)0 (0)0 (0)--
Total11 (17.5)12 (18.5)10 (15.4)7.2920.274
DISCUSSION

In this study, the qCON and qNOX indices were combined to monitor the anesthesia depth of acute ECT in patients with MDD. The qCON index significantly affected the EEG seizure duration, peak mid-ictal amplitude, and maximum heart rate during bilateral temporal ECT under propofol anesthesia. The qNOX index has a significant effect on PSI, which has not been previously reported. This study also found that age, ECT treatment sessions, and anesthetic-ECT time intervals had significant effects on EEG seizure parameters, which is consistent with previous studies[12,19,29,56-58].

The qCON index is similar to the BIS and Narcotrend indices, which mainly reflect the depths of sedation and hypnosis. In this study, the participants were divided into three groups according to the range of the qCON index during electrical stimulation. Participants in the three groups were subjected to electrical stimulation at different depths of anesthesia. The results showed that anesthesia depth significantly affected the EEG seizure duration, PSI, peak mid-ictal amplitude, EEG coherence, and maximum heart rate during ECT. The lighter the anesthesia, the better the EEG seizure parameters and the higher the maximum heart rate during ECT, which was consistent with previous studies on the effect of anesthesia depth monitored by BIS or Narcotrend on EEG seizure parameters during ECT[28,29,59-61].

None of the patients in the three groups were aware during their ECT treatments. The main reasons are as follows. First, after the injection of propofol, the anesthesiologist continuously called the patient’s name. When they ensured that the patient had no response and the eyelash reflex had disappeared, succinylcholine was injected for muscle relaxation. Second, the timing of electrical stimulation should be when the qCON index increases to the corresponding range, rather than immediately after propofol injection. After propofol injection, the qCON index decreased rapidly and then increased slowly, indicating that the blood concentration of propofol in the brain reached its peak and was then redistributed, and the ECT in this study adopted a bilateral temporal position. When patients are treated with bilateral temporal ECT, which tends to obliterate the memory of the ECT procedure[24]. Therefore, even if patients are conscious during ECT, they are unlikely to remember their consciousness after treatment.

An unexpected finding of this study was that the qNOX index significantly affected the PSI. The standard β coefficient was 0.162, which indicated that the higher the qNOX index, the higher the PSI. PSI refers to EEG suppression after a seizure and is considered to be an indication of good seizure quality if the PSI is greater than 80%[15,55]. The qNOX index reflects the degree of nociceptive stimulus response. The results of this study showed that the degree of noxious stimulation in patients after ECT was positively correlated with the PSI. Therefore, the higher the PSI score, the greater the noxious stimulation of patients. However, the influence of noxious stimulation on the clinical effects (such as antidepressant effects and cognitive impairment) of ECT in patients with depression remains unclear, and further large-scale clinical research is needed. This also suggests that higher PSI is not always advantageous, because excessive PSI may represent greater noxious stimulation of ECT in patients.

This study also examined the recovery time and complications of ECT in patients with MDD with different qCON indices. It was found that the recovery time was only related to the age of patients. The older the patient, the longer the recovery time. However, there was no significant relationship with the qCON index. White et al[61] showed that depth of anesthesia (BIS index) was positively correlated with recovery time, while Gombar et al[60] found that depth of anesthesia (BIS index) was negatively correlated with recovery time. The reasons for the inconsistent results among studies may be related to the different ages of the people included in these studies, the different electrode positions used in ECT, and the different anesthetic drugs used. Common complications during the recovery period included headache, dizziness, muscle soreness, nausea, and vomiting; there were no significant differences among the three groups. This indicates that the depth of anesthesia did not significantly affect complications during the recovery period when propofol anesthesia was used for bilateral temporal ECT.

This study also compared the clinical effects of ECT at different anesthesia depths in patients with MDD. Although light anesthesia can yield better EEG seizure parameters, there were no significant differences in the 24-item HAM-D, SDS, or MoCA scores among the three groups. The main reason for this may be that we used an age-based method instead of titration to set the initial stimulus dose. The age-based method does not require titration of the seizure threshold for the participants. Although there may be some patients with higher seizure thresholds, the initial stimulus dose based on one-half the patient’s age is often higher than the seizure threshold determined by titration[62,63]. The effect of anesthesia depth on seizure threshold may be masked by a higher stimulation charge. However, the implementation of ECT was mainly carried out by psychiatrists who chose to set the initial stimulus dose, which not only simplifies the operation and avoids multiple titrations, but can also quickly exert antidepressant effects in patients with MDD. Another reason may be that the sample size of this study was small and the same dosage of anesthetic propofol was used, so the comparison of clinical effects is only exploratory.

This study had several limitations. First, the participants in this study were all patients with MDD, and antidepressants and their enhancers had not been removed or reduced during ECT. Hence, the effects of antidepressants and enhancers (such as benzodiazepines, lithium, and antiepileptic drugs) on seizures cannot be excluded in this study[19-21,64]. Second, this study used an age-based method instead of titration to set the initial stimulus dose; although this approach can quickly exert antidepressant effects in patients with MDD, it may mask the effect of anesthesia depth on seizure threshold and may result in excessively high suprathreshold stimulation for some patients. Thirdly, end-tidal partial pressure of CO2 was not monitored in this study. Some studies have suggested that excessive ventilation can improve the quality of seizures, although some controversies remain[60,65]. Finally, this was a single-center, randomized, single-blind study with a small sample size. The secondary result of the study is exploratory, and thus needs to be further confirmed by a multicenter large-sample study.

CONCLUSION

This study confirmed that the qCON index can be used to monitor the sedation depth of ECT in patients with MDD and to guide the appropriate time of electrical stimulation during ECT. Electrical stimulation at a qCON index of 60-70 resulted in improved EEG seizure parameters. The qNOX index reflects the degree of noxious stimulation caused by ECT and is positively correlated with PSI. The higher the PSI, the greater the noxious stimulation experienced by patients. In ECT, we should consider both the influence of sedation depth on the quality of seizures and the degree of noxious stimulation caused by the treatment technology itself.

ACKNOWLEDGEMENTS

We gratefully acknowledge all patients and researchers who participated in this study. Furthermore, we gratefully acknowledge Professor Li Kuang for providing assistance in the clinical trial and Feng Lv for useful comments on the manuscript and statistics.

Footnotes

Provenance and peer review: Unsolicited article; Externally peer reviewed.

Peer-review model: Single blind

Specialty type: Psychiatry

Country of origin: China

Peer-review report’s classification

Scientific Quality: Grade B, Grade C

Novelty: Grade B, Grade B

Creativity or Innovation: Grade B, Grade B

Scientific Significance: Grade B, Grade B

P-Reviewer: Arias de la Torre J; Rocha-Rodrigues S S-Editor: Wang JJ L-Editor: A P-Editor: Zheng XM

References
1.  Noori T, Sureda A, Sobarzo-Sánchez E, Shirooie S. The Role of Natural Products in Treatment of Depressive Disorder. Curr Neuropharmacol. 2022;20:929-949.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 3]  [Cited by in F6Publishing: 3]  [Article Influence: 1.5]  [Reference Citation Analysis (0)]
2.  Denee T, Ming T, Waller J, Bailey T, Rajkovic-Hooley O, Middleton-Dalby C, Le HH, Zhang Q, McCrone P, Taylor D. A retrospective chart review study to quantify the monthly medical resource use and costs of treating patients with treatment resistant depression in the United Kingdom. Curr Med Res Opin. 2021;37:311-319.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 1]  [Reference Citation Analysis (0)]
3.  Herrman H, Patel V, Kieling C, Berk M, Buchweitz C, Cuijpers P, Furukawa TA, Kessler RC, Kohrt BA, Maj M, McGorry P, Reynolds CF 3rd, Weissman MM, Chibanda D, Dowrick C, Howard LM, Hoven CW, Knapp M, Mayberg HS, Penninx BWJH, Xiao S, Trivedi M, Uher R, Vijayakumar L, Wolpert M. Time for united action on depression: a Lancet-World Psychiatric Association Commission. Lancet. 2022;399:957-1022.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 103]  [Cited by in F6Publishing: 301]  [Article Influence: 150.5]  [Reference Citation Analysis (0)]
4.  UK ECT Review Group. Efficacy and safety of electroconvulsive therapy in depressive disorders: a systematic review and meta-analysis. Lancet. 2003;361:799-808.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 1076]  [Cited by in F6Publishing: 1008]  [Article Influence: 48.0]  [Reference Citation Analysis (1)]
5.  Kaster TS, Vigod SN, Gomes T, Sutradhar R, Wijeysundera DN, Blumberger DM. Risk of serious medical events in patients with depression treated with electroconvulsive therapy: a propensity score-matched, retrospective cohort study. Lancet Psychiatry. 2021;8:686-695.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 25]  [Cited by in F6Publishing: 33]  [Article Influence: 11.0]  [Reference Citation Analysis (0)]
6.  Kaster TS, Blumberger DM, Gomes T, Sutradhar R, Wijeysundera DN, Vigod SN. Risk of suicide death following electroconvulsive therapy treatment for depression: a propensity score-weighted, retrospective cohort study in Canada. Lancet Psychiatry. 2022;9:435-446.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 9]  [Cited by in F6Publishing: 11]  [Article Influence: 5.5]  [Reference Citation Analysis (0)]
7.  Espinoza RT, Kellner CH. Electroconvulsive Therapy. N Engl J Med. 2022;386:667-672.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 30]  [Cited by in F6Publishing: 87]  [Article Influence: 43.5]  [Reference Citation Analysis (0)]
8.  Deng ZD, Robins PL, Regenold W, Rohde P, Dannhauer M, Lisanby SH. How electroconvulsive therapy works in the treatment of depression: is it the seizure, the electricity, or both? Neuropsychopharmacology. 2024;49:150-162.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 5]  [Cited by in F6Publishing: 7]  [Article Influence: 7.0]  [Reference Citation Analysis (0)]
9.  Kritzer MD, Peterchev AV, Camprodon JA. Electroconvulsive Therapy: Mechanisms of Action, Clinical Considerations, and Future Directions. Harv Rev Psychiatry. 2023;31:101-113.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 1]  [Reference Citation Analysis (0)]
10.  Weiss A, Hussain S, Ng B, Sarma S, Tiller J, Waite S, Loo C. Royal Australian and New Zealand College of Psychiatrists professional practice guidelines for the administration of electroconvulsive therapy. Aust N Z J Psychiatry. 2019;53:609-623.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 74]  [Cited by in F6Publishing: 94]  [Article Influence: 18.8]  [Reference Citation Analysis (0)]
11.  Minelli A, Abate M, Zampieri E, Gainelli G, Trabucchi L, Segala M, Sartori R, Gennarelli M, Conca A, Bortolomasi M. Seizure Adequacy Markers and the Prediction of Electroconvulsive Therapy Response. J ECT. 2016;32:88-92.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 38]  [Cited by in F6Publishing: 37]  [Article Influence: 4.6]  [Reference Citation Analysis (0)]
12.  de Arriba-Arnau A, Dalmau Llitjos A, Soria V, Savino S, Salvat-Pujol N, Curto J, Menchón JM, Urretavizcaya M. Factors Predicting Ictal Quality in Bilateral Electroconvulsive Therapy Sessions. Brain Sci. 2021;11.  [PubMed]  [DOI]  [Cited in This Article: ]  [Reference Citation Analysis (0)]
13.  Perera TD, Luber B, Nobler MS, Prudic J, Anderson C, Sackeim HA. Seizure expression during electroconvulsive therapy: relationships with clinical outcome and cognitive side effects. Neuropsychopharmacology. 2004;29:813-825.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 102]  [Cited by in F6Publishing: 107]  [Article Influence: 5.4]  [Reference Citation Analysis (0)]
14.  Loo CK, Schweitzer I, Pratt C. Recent advances in optimizing electroconvulsive therapy. Aust N Z J Psychiatry. 2006;40:632-638.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 32]  [Cited by in F6Publishing: 35]  [Article Influence: 1.9]  [Reference Citation Analysis (0)]
15.  Kranaster L, Aksay SS, Bumb JM, Hoyer C, Jennen-Steinmetz C, Sartorius A. A novel Seizure Quality Index based on ictal parameters for optimizing clinical decision making in electroconvulsive therapy. Part 1: development. Eur Arch Psychiatry Clin Neurosci. 2018;268:819-830.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 15]  [Cited by in F6Publishing: 14]  [Article Influence: 2.3]  [Reference Citation Analysis (0)]
16.  Azuma H, Fujita A, Sato K, Arahata K, Otsuki K, Hori M, Mochida Y, Uchida M, Yamada T, Akechi T, Furukawa TA. Postictal suppression correlates with therapeutic efficacy for depression in bilateral sine and pulse wave electroconvulsive therapy. Psychiatry Clin Neurosci. 2007;61:168-173.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 58]  [Cited by in F6Publishing: 58]  [Article Influence: 3.4]  [Reference Citation Analysis (0)]
17.  Kimball JN, Rosenquist PB, Dunn A, McCall WV. Prediction of antidepressant response in both 2.25xthreshold RUL and fixed high dose RUL ECT. J Affect Disord. 2009;112:85-91.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 19]  [Cited by in F6Publishing: 20]  [Article Influence: 1.3]  [Reference Citation Analysis (0)]
18.  Kirov G, Jauhar S, Sienaert P, Kellner CH, McLoughlin DM. Electroconvulsive therapy for depression: 80 years of progress. Br J Psychiatry. 2021;219:594-597.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 17]  [Cited by in F6Publishing: 27]  [Article Influence: 9.0]  [Reference Citation Analysis (0)]
19.  Hoyer C, Kranaster L, Janke C, Sartorius A. Impact of the anesthetic agents ketamine, etomidate, thiopental, and propofol on seizure parameters and seizure quality in electroconvulsive therapy: a retrospective study. Eur Arch Psychiatry Clin Neurosci. 2014;264:255-261.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 76]  [Cited by in F6Publishing: 77]  [Article Influence: 7.7]  [Reference Citation Analysis (0)]
20.  Abdollahi MH, Izadi A, Hajiesmaeili MR, Ghanizadeh A, Dastjerdi G, Hosseini HA, Ghiamat MM, Abbasi HR. Effect of etomidate versus thiopental on major depressive disorder in electroconvulsive therapy, a randomized double-blind controlled clinical trial. J ECT. 2012;28:10-13.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 16]  [Cited by in F6Publishing: 16]  [Article Influence: 1.3]  [Reference Citation Analysis (0)]
21.  Reddy SD, Reddy DS. Midazolam as an anticonvulsant antidote for organophosphate intoxication--A pharmacotherapeutic appraisal. Epilepsia. 2015;56:813-821.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 58]  [Cited by in F6Publishing: 70]  [Article Influence: 7.8]  [Reference Citation Analysis (0)]
22.  Soehle M, Kayser S, Ellerkmann RK, Schlaepfer TE. Bilateral bispectral index monitoring during and after electroconvulsive therapy compared with magnetic seizure therapy for treatment-resistant depression. Br J Anaesth. 2014;112:695-702.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 17]  [Cited by in F6Publishing: 17]  [Article Influence: 1.7]  [Reference Citation Analysis (0)]
23.  Sartorius A, Muñoz-Canales EM, Krumm B, Krier A, Andres FJ, Bender HJ, Henn FA. ECT anesthesia: the lighter the better? Pharmacopsychiatry. 2006;39:201-204.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 23]  [Cited by in F6Publishing: 18]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
24.  Andrade C, Thirthalli J, Gangadhar BN. Unilateral nondominant electrode placement as a risk factor for recall of awareness under anesthesia during electroconvulsive therapy. J ECT. 2007;23:201-203.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 10]  [Cited by in F6Publishing: 10]  [Article Influence: 0.6]  [Reference Citation Analysis (0)]
25.  Hanss R, Bauer M, Bein B, Goeder R, Buttgereit B, Schulz-Du Bois AC, Steinfath M, Scholz J. Bispectral index-controlled anaesthesia for electroconvulsive therapy. Eur J Anaesthesiol. 2006;23:202-207.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 10]  [Cited by in F6Publishing: 10]  [Article Influence: 0.6]  [Reference Citation Analysis (0)]
26.  Thimmaiah R, Thirthalli J, Ramesh VJ, Radhakrishnan MC, Muralidharan K, Mahadevaiah M, Gangadhar BN, Umamaheshwara Rao GS. Effect of a course of electroconvulsive therapy on interictal bispectral index values: a prospective study. J ECT. 2012;28:20-23.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 9]  [Cited by in F6Publishing: 10]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
27.  Zarei K, Sparr NA, Trapp NT, Neuhaus ED, Cromwell JW, Boes AD, Shinozaki G. Bispectral EEG (BSEEG) to assess arousal after electro-convulsive therapy (ECT). Psychiatry Res. 2020;285:112811.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 6]  [Cited by in F6Publishing: 5]  [Article Influence: 1.3]  [Reference Citation Analysis (0)]
28.  Guerrier G, Gianni MA. The effectiveness of BIS monitoring during electro-convulsive therapy: A systematic review and meta-analysis. J Clin Anesth. 2019;58:100-104.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 4]  [Cited by in F6Publishing: 4]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
29.  Gasteiger L, Heil M, Hörner E, Andexer J, Kemmler G, Hausmann A, Lederer W. Relationship Between Anesthesia Depth and Quality of Seizures in Patients Undergoing Electroconvulsive Therapy: A Prospective Observational Study. J ECT. 2022;38:62-67.  [PubMed]  [DOI]  [Cited in This Article: ]  [Reference Citation Analysis (0)]
30.  Bruhn J, Myles PS, Sneyd R, Struys MM. Depth of anaesthesia monitoring: what's available, what's validated and what's next? Br J Anaesth. 2006;97:85-94.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 198]  [Cited by in F6Publishing: 168]  [Article Influence: 9.3]  [Reference Citation Analysis (0)]
31.  Hajat Z, Ahmad N, Andrzejowski J. The role and limitations of EEG-based depth of anaesthesia monitoring in theatres and intensive care. Anaesthesia. 2017;72 Suppl 1:38-47.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 78]  [Cited by in F6Publishing: 84]  [Article Influence: 12.0]  [Reference Citation Analysis (0)]
32.  Fernández-Candil JL, Terradas SP, Barriuso EV, García LM, Cogollo MG, Gallego LG. Predicting unconsciousness after propofol administration: qCON, BIS, and ALPHA band frequency power. J Clin Monit Comput. 2021;35:723-729.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 2]  [Cited by in F6Publishing: 1]  [Article Influence: 0.3]  [Reference Citation Analysis (0)]
33.  Hight D, Kreuzer M, Ugen G, Schuller P, Stüber F, Sleigh J, Kaiser HA. Five commercial 'depth of anaesthesia' monitors provide discordant clinical recommendations in response to identical emergence-like EEG signals. Br J Anaesth. 2023;130:536-545.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in F6Publishing: 10]  [Reference Citation Analysis (0)]
34.  Katoh T, Bito H, Sato S. Influence of age on hypnotic requirement, bispectral index, and 95% spectral edge frequency associated with sedation induced by sevoflurane. Anesthesiology. 2000;92:55-61.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 71]  [Cited by in F6Publishing: 62]  [Article Influence: 2.6]  [Reference Citation Analysis (0)]
35.  Dennhardt N, Arndt S, Beck C, Boethig D, Heiderich S, Schultz B, Weber F, Sümpelmann R. Effect of age on Narcotrend Index monitoring during sevoflurane anesthesia in children below 2 years of age. Paediatr Anaesth. 2018;28:112-119.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 16]  [Cited by in F6Publishing: 19]  [Article Influence: 3.2]  [Reference Citation Analysis (0)]
36.  Tagliabue S, Lindner C, da Prat IC, Sanchez-Guerrero A, Serra I, Kacprzak M, Maruccia F, Silva OM, Weigel UM, de Nadal M, Poca MA, Durduran T. Comparison of cerebral metabolic rate of oxygen, blood flow, and bispectral index under general anesthesia. Neurophotonics. 2023;10:015006.  [PubMed]  [DOI]  [Cited in This Article: ]  [Reference Citation Analysis (0)]
37.  Boselli E, Daniela-Ionescu M, Bégou G, Bouvet L, Dabouz R, Magnin C, Allaouchiche B. Prospective observational study of the non-invasive assessment of immediate postoperative pain using the analgesia/nociception index (ANI). Br J Anaesth. 2013;111:453-459.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 76]  [Cited by in F6Publishing: 83]  [Article Influence: 7.5]  [Reference Citation Analysis (0)]
38.  Storm H. Changes in skin conductance as a tool to monitor nociceptive stimulation and pain. Curr Opin Anaesthesiol. 2008;21:796-804.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 153]  [Cited by in F6Publishing: 162]  [Article Influence: 10.1]  [Reference Citation Analysis (0)]
39.  Schneider G, Jordan D, Schwarz G, Bischoff P, Kalkman CJ, Kuppe H, Rundshagen I, Omerovic A, Kreuzer M, Stockmanns G, Kochs EF; European Multicenter EEGAEP Anesthesia Monitoring Study Group and Research Group Knowledge-based Signal Processing. Monitoring depth of anesthesia utilizing a combination of electroencephalographic and standard measures. Anesthesiology. 2014;120:819-828.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 46]  [Cited by in F6Publishing: 50]  [Article Influence: 5.0]  [Reference Citation Analysis (0)]
40.  Ben-Israel N, Kliger M, Zuckerman G, Katz Y, Edry R. Monitoring the nociception level: a multi-parameter approach. J Clin Monit Comput. 2013;27:659-668.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 76]  [Cited by in F6Publishing: 92]  [Article Influence: 8.4]  [Reference Citation Analysis (0)]
41.  Barvais L, Engelman E, Eba JM, Coussaert E, Cantraine F, Kenny GN. Effect site concentrations of remifentanil and pupil response to noxious stimulation. Br J Anaesth. 2003;91:347-352.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 110]  [Cited by in F6Publishing: 102]  [Article Influence: 4.9]  [Reference Citation Analysis (0)]
42.  Rollins MD, Feiner JR, Lee JM, Shah S, Larson M. Pupillary effects of high-dose opioid quantified with infrared pupillometry. Anesthesiology. 2014;121:1037-1044.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 58]  [Cited by in F6Publishing: 60]  [Article Influence: 6.0]  [Reference Citation Analysis (0)]
43.  Gruenewald M, Ilies C, Herz J, Schoenherr T, Fudickar A, Höcker J, Bein B. Influence of nociceptive stimulation on analgesia nociception index (ANI) during propofol-remifentanil anaesthesia. Br J Anaesth. 2013;110:1024-1030.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 100]  [Cited by in F6Publishing: 99]  [Article Influence: 9.0]  [Reference Citation Analysis (0)]
44.  Melia U, Gabarron E, Agustí M, Souto N, Pineda P, Fontanet J, Vallverdu M, Jensen EW, Gambus P. Comparison of the qCON and qNOX indices for the assessment of unconsciousness level and noxious stimulation response during surgery. J Clin Monit Comput. 2017;31:1273-1281.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 20]  [Cited by in F6Publishing: 17]  [Article Influence: 2.1]  [Reference Citation Analysis (0)]
45.  Revuelta M, Paniagua P, Campos JM, Fernández JA, Martínez A, Jospin M, Litvan H. Validation of the index of consciousness during sevoflurane and remifentanil anaesthesia: a comparison with the bispectral index and the cerebral state index. Br J Anaesth. 2008;101:653-658.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 45]  [Cited by in F6Publishing: 45]  [Article Influence: 2.8]  [Reference Citation Analysis (0)]
46.  García PS, Kreuzer M, Hight D, Sleigh JW. Effects of noxious stimulation on the electroencephalogram during general anaesthesia: a narrative review and approach to analgesic titration. Br J Anaesth. 2021;126:445-457.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 13]  [Cited by in F6Publishing: 41]  [Article Influence: 13.7]  [Reference Citation Analysis (0)]
47.  Lichtenfeld F, Kratzer S, Hinzmann D, García PS, Schneider G, Kreuzer M. The Influence of Electromyographic on Electroencephalogram-Based Monitoring: Putting the Forearm on the Forehead. Anesth Analg. 2024;138:1285-1294.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 1]  [Cited by in F6Publishing: 1]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
48.  Müller JN, Kreuzer M, García PS, Schneider G, Hautmann H. Monitoring depth of sedation: evaluating the agreement between the Bispectral Index, qCON and the Entropy Module's State Entropy during flexible bronchoscopy. Minerva Anestesiol. 2017;83:563-573.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 10]  [Cited by in F6Publishing: 19]  [Article Influence: 2.7]  [Reference Citation Analysis (0)]
49.  Kang J, Fang C, Li Y, Yuan Y, Niu K, Zheng Y, Yu Y, Wang G, Li Y. Effects of qCON and qNOX-guided general anaesthesia management on patient opioid use and prognosis: a study protocol. BMJ Open. 2023;13:e069134.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in F6Publishing: 1]  [Reference Citation Analysis (0)]
50.  Jensen EW, Valencia JF, López A, Anglada T, Agustí M, Ramos Y, Serra R, Jospin M, Pineda P, Gambus P. Monitoring hypnotic effect and nociception with two EEG-derived indices, qCON and qNOX, during general anaesthesia. Acta Anaesthesiol Scand. 2014;58:933-941.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 62]  [Cited by in F6Publishing: 79]  [Article Influence: 7.9]  [Reference Citation Analysis (0)]
51.  Andrade C, Arumugham SS, Thirthalli J. Adverse Effects of Electroconvulsive Therapy. Psychiatr Clin North Am. 2016;39:513-530.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 84]  [Cited by in F6Publishing: 108]  [Article Influence: 13.5]  [Reference Citation Analysis (0)]
52.  Hammershøj LG, Petersen JZ, Jensen HM, Jørgensen MB, Miskowiak KW. Cognitive Adverse Effects of Electroconvulsive Therapy: A Discrepancy Between Subjective and Objective Measures? J ECT. 2022;38:30-38.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 5]  [Cited by in F6Publishing: 6]  [Article Influence: 3.0]  [Reference Citation Analysis (0)]
53.  Rasimas JJ, Stevens SR, Rasmussen KG. Seizure length in electroconvulsive therapy as a function of age, sex, and treatment number. J ECT. 2007;23:14-16.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 30]  [Cited by in F6Publishing: 43]  [Article Influence: 2.5]  [Reference Citation Analysis (0)]
54.  Rasmussen K. The practice of electroconvulsive therapy: recommendations for treatment, training, and privileging (second edition). J ECT. 2002;18:58-59.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 35]  [Cited by in F6Publishing: 40]  [Article Influence: 1.8]  [Reference Citation Analysis (0)]
55.  Kranaster L, Hoyer C, Janke C, Sartorius A. Bispectral index monitoring and seizure quality optimization in electroconvulsive therapy. Pharmacopsychiatry. 2013;46:147-150.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 43]  [Cited by in F6Publishing: 50]  [Article Influence: 4.5]  [Reference Citation Analysis (0)]
56.  Taylor R, Hadzi-Pavlovic D, Nikolin S, Bull M, Wark H, Leyden J, Harper S, Martin D, Galvez V, Loo C. The anaesthetic-ECT time interval with thiopentone-Impact on seizure quality. J Affect Disord. 2019;252:135-140.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 7]  [Cited by in F6Publishing: 7]  [Article Influence: 1.4]  [Reference Citation Analysis (0)]
57.  Taylor R, Wark H, Leyden J, Simpson B, McGoldrick J, Hadzi-Pavlovic D, Han HK, Nikolin S, Martin D, Loo C. Effects of the Anaesthetic-ECT time interval and ventilation rate on seizure quality in electroconvulsive therapy: A prospective randomised trial. Brain Stimul. 2020;13:450-456.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 4]  [Cited by in F6Publishing: 5]  [Article Influence: 1.3]  [Reference Citation Analysis (0)]
58.  Luccarelli J, McCoy TH Jr, Seiner SJ, Henry ME. Changes in seizure duration during acute course electroconvulsive therapy. Brain Stimul. 2021;14:941-946.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 5]  [Cited by in F6Publishing: 15]  [Article Influence: 5.0]  [Reference Citation Analysis (0)]
59.  Nishihara F, Saito S. Pre-ictal bispectral index has a positive correlation with seizure duration during electroconvulsive therapy. Anesth Analg. 2002;94:1249-1252, table of contents.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 21]  [Cited by in F6Publishing: 21]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
60.  Gombar S, Aggarwal D, Khanna AK, Gombar KK, Chavan BS. The bispectral electroencephalogram during modified electroconvulsive therapy under propofol anesthesia: relation with seizure duration and awakening. J ECT. 2011;27:114-118.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 11]  [Cited by in F6Publishing: 11]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
61.  White PF, Rawal S, Recart A, Thornton L, Litle M, Stool L. Can the bispectral index be used to predict seizure time and awakening after electroconvulsive therapy? Anesth Analg. 2003;96:1636-1639.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 29]  [Cited by in F6Publishing: 24]  [Article Influence: 1.1]  [Reference Citation Analysis (0)]
62.  Yasuda K, Kobayashi K, Yamaguchi M, Tanaka K, Fujii T, Kitahara Y, Tamaoki T, Matsushita Y, Nunomura A, Motohashi N. Seizure threshold and the half-age method in bilateral electroconvulsive therapy in Japanese patients. Psychiatry Clin Neurosci. 2015;69:49-54.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 23]  [Cited by in F6Publishing: 25]  [Article Influence: 2.8]  [Reference Citation Analysis (0)]
63.  Bennett DM, Perrin JS, Currie J, Blacklaw L, Kuriakose J, Rao A, Reid IC. A comparison of ECT dosing methods using a clinical sample. J Affect Disord. 2012;141:222-226.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 22]  [Cited by in F6Publishing: 22]  [Article Influence: 1.8]  [Reference Citation Analysis (0)]
64.  Pluijms EM, Kamperman AM, Hoogendijk WJ, Birkenhäger TK, van den Broek WW. Influence of an adjuvant antidepressant on the efficacy of electroconvulsive therapy: A systematic review and meta-analysis. Aust N Z J Psychiatry. 2021;55:366-380.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 11]  [Cited by in F6Publishing: 9]  [Article Influence: 3.0]  [Reference Citation Analysis (0)]
65.  Aksay SS, Bumb JM, Janke C, Hoyer C, Kranaster L, Sartorius A. New evidence for seizure quality improvement by hyperoxia and mild hypocapnia. J ECT. 2014;30:287-291.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 34]  [Cited by in F6Publishing: 36]  [Article Influence: 3.6]  [Reference Citation Analysis (0)]