Published online Aug 12, 2014. doi: 10.5318/wjo.v4.i3.87
Revised: May 23, 2014
Accepted: June 10, 2014
Published online: August 12, 2014
Processing time: 253 Days and 3.3 Hours
AIM: To investigate the outcomes of off label single-piece acrylic intraocular lenses (SPA-IOL) ciliary sulcus placement compared to three-piece IOL (3P-IOL).
METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group.
RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPA-IOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macula edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3P-IOL group.
CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible.
Core tip: Single-piece acrylic intraocular lenses implants are FDA approved for placement into the capsular bag. Their off label placement into the ciliary sulcus is not recommended by the manufacturer and has been the subject of controversy in ophthalmology. This retrospective case series is unique in that patients were followed for 16 mo (range 1.2-37 mo) without intervention and visual outcomes and comorbidities were evaluated and compared with eyes receiving standard of care sulcus placed three-piece intraocular lenses implants.
- Citation: Junk AK. Considerations in the management of single-piece intraocular lenses outside the capsular bag. World J Ophthalmol 2014; 4(3): 87-91
- URL: https://www.wjgnet.com/2218-6239/full/v4/i3/87.htm
- DOI: https://dx.doi.org/10.5318/wjo.v4.i3.87
With the advent of small incision cataract surgery, and the development of premium intraocular lenses foldable single-piece acrylic (SPA) intraocular lenses (IOLs) have gained in popularity. For example, over 50 million AcrySof® (Alcon, Ft. Worth, Texas) IOLs have been implanted world- wide[1]. The SPA-IOL has been modified to allow for concomitant astigmatism (toric IOL) and presbyopia correction (multifocal IOL) at the time of cataract surgery. The SPA-IOL design assures excellent apposition with the posterior capsule allowing stability within the capsular bag. When placed in the bag the SPA-IOL allowed for more posterior position relative to the iris than a 3P-IOL[2]. Excellent biocompatibility and design reduce the incidence of posterior capsule opacification (PCO)[3,4]. Due to zero angulation of the haptic-optic junction it is not recommended to place SPA-IOLs into the ciliary sulcus[5].
Chang et al[6] reported a series of 30 patients in a referral setting with complications related to sulcus placed SPA-IOLs. The authors strongly suggest IOL exchange as primary treatment and review alternative IOL choices for primary cataract surgeons. Conversely, Taskapili et al[7] reports on 89 eyes with sulcus placed SPA-IOL compared with 72 eyes with sulcus placed PMMA IOL and suggesting equal, low rates of complications, glaucoma 19% vs 16%, CME 8% vs 17%, anterior uveitis 6% vs 7%, IOL decentration 4% in both. Endophthalmitis was observed in the control group only (2 of 72 eyes). Other known complications associated with sulcus placed SPA-IOL include pigment dispersion syndrome, iris chafing, uveitis-glaucoma-hyphema syndrome and vitreous hemorrhage[8-12]. Uy et al[13] noted 35% incidence of pigment dispersion and secondary glaucoma in 15% of 20 patients with sulcus placed SPA-IOL.
The cases presented here are unique because they constitute a consecutive case series of eyes with posterior capsular tear, anterior vitrectomy, and off-label placed SPA-IOLs compared with three-piece IOLs in the ciliary sulcus at a single hospital. Within this institution, one surgeon routinely placed SPA-IOLs in the ciliary sulcus if there was capsular support, and other surgeons did not. Given the controversy, we aimed to review cases of sulcus placed SPA-IOLs to determine visual outcomes and complications. No cases were referred from outside centers, and all operative and perioperative data was well documented in the electronic medical record.
This is a retrospective chart review of fourteen consecutive patients who underwent cataract surgery complicated by posterior capsule tear and sulcus placed IOL at one medical center. The study was approved by the institutional human subjects review board. Eight eyes with sulcus placed SPA-IOLs and six eyes with three-piece (3P) acrylic IOLs were included. One patient was lost to follow up after one month. All patients were male, mean age was 80 years (range 71-87 years) at the time of surgery. Demographic characteristics of the two groups were similar and are summarized in Table 1. During phacoemulsification a posterior capsule tear with vitreous prolapse was encountered. Anterior vitrectomy was performed and the IOL was placed into the ciliary sulcus. None of the eyes had retained lens material at the end of the procedure. Six of the SPA-IOLs were monofocal Acrysof® SN60WF implants, two implants were toric SPA-IOLs. No IOL was suture fixated to the iris or the sclera.
Case (n) | Age atsurgery | Operativeeye | IOLimplanted | Pre-op glauc-oma diagnosis | |
SPA-IOL | 1 | 80 | OD | SN60WF | No |
group | 2 | 85 | OD | SN60WF | No |
3 | 87 | OS | SN60T5 | No | |
4 | 76 | OD | SN60WF | No | |
5 | 71 | OS | SN60WF | No | |
6 | 79 | OS | SN60T5 | No | |
7 | 87 | OD | SN60WF | Suspect | |
8 | 76 | OD | SN60WF | No | |
Three-piece | 9 | 86 | OD | MA60AC | Suspect |
IOL group | 10 | 74 | OD | MA60AC | No |
11 | 88 | OD | MA60AC | No | |
12 | 86 | OS | MA60AC | No | |
13 | 76 | OS | MA60AC | No | |
14 | 87 | OS | MA60AC | Yes |
Clinical data on all patients in the two IOL groups are summarized in Table 2. Mean pre-operative spherical equivalent was similar in the SPA-IOL and 3P-IOL groups (+0.47 and +0.32 respectively). Persistent iritis, pigment dispersion and CME were documented in several patients with SPA-IOL, while only one patient with a 3P- IOL had documented CME after surgery. No patient with 3P-IOL had pigment dispersion or prolonged iritis defined as anterior chamber cellular reaction present more than one month after surgery. It is also noteworthy that in the SPA-IOL group, elevated intraocular pressure above 21 mmHg was recorded in 63% of cases. This was treated with intraocular pressure lowering medications beyond postoperative week one. One of the eyes had aqueous drainage implant surgery. The patients were continued on glaucoma medications six month or more after surgery. In contrast, only patient in the three-piece IOL group required intraocular pressure lowering medication after post operative week one, this patient had pre-existing glaucoma. Best corrected visual acuity (BCVA) was 20/30 or better in 4/8 patients in the SPA-IOL group and in 3/7 patients in the 3P-IOL group at post-op month one. In the 3P-IOL group poor vision at month one was attributable to suture-induced astigmatism and resolved after suture removal. Four of eight patients with SPA-IOL and four of six with 3P-IOL achieved a BCVA of 20/30 or better at the time of last follow up. Two patients in the 3P-IOL group had documented comorbidities preoperatively and therefore reduced visual prognosis. One eye was diagnosed with age related macula degeneration (ARMD) and one eye with advanced glaucoma. Loss of follow up after two month or less occurred in two individuals (25%) with SPA-IOL (one patient deceased, one for unknown reason) compared to three patients (43%) in the 3P-IOL group (for unknown reasons). All patients lost to follow up had best corrected visual acuities of 20/30 or better at their last exam.
Case | Pre-op BCVA | Pre-op refraction | POM1 refraction | POM1 BCVA | Most recent BCVA | Re-operation | CME | PDS | Post-op Glc meds | Glc meds last F/U | Months of F/U | |
SPA-IOL | 1 | 20/50 | +1.25 + 1.25X012 | -4.50 + 4.75X0011 | 20/40 | 20/20 | Wound leak | No | No | Yes | No | 37 |
2 | 20/60 | -3.25 + 3.50X180 | -2.75 + 2.25X003 | 20/50 | 20/50 | Bgi | Yes | No | Yes | No | 32 | |
3 | 20/100 | +0.50 + 0.50X180 | -3.75 + 3.00X138 | 20/20 | 20/40 | No | No | Yes | No | No | 7 | |
4 | 20/60 | -0.75 + 1.00X163 | -1.50 + 1.75X0051 | 20/25 | 20/25 | No | No | No | No | No | 15 | |
5 | 20/70 | +3.25 + 1.00X105 | +2.00 + 0.75X1051 | 20/60 | 20/50 | No | Yes | Yes | No | No | 19 | |
6 | 20/40 | +0.50 +2.25X178 | -3.75 + 3.75X0251 | 20/40 | 20/40 | No | Yes | Yes | Yes | Yes | 15 | |
7 | 20/60 | -3.25 sph | -2.75 + 2.00X015 | 20/25 | 20/25 | No | No | No | Yes | Yes | 1.5 | |
8 | 20/40 | +0.75 sph | -0.50 + 1.00X125 | 20/30 | 20/30 | No | No | No | Yes | Yes | 1.2 | |
Three-piece | 9 | 20/60 | -5.75 + 2.00X177 | -2.00 + 1.75X175 | 20/30 | 20/30 | No | Yes | No | No | No | 31 |
IOL | 10 | 20/80 | -2.50 + 0.50X155 | Unable1 | 20/400 | 20/60 | No | No | No | No | No | 38 |
11 | 20/60 | +3 | -1.75 + 1.75X0041 | 20/25 | 20/25 | No | No | No | No | No | 2 | |
12 | 20/70 | +2.00 + 1.25X162 | Unable1 | CF | CF2 | No | No | No | No | No | 25 | |
13 | 20/50 | -2.00 + 2.25X005 | -2.50 + 1.00X0061 | 20/60 | 20/25 | No | No | No | No | No | 2 | |
14 | 20/100 | -2.75 + 1.50X165 | Unable1 | CF | CF3 | No | No | No | Yes | Yes | 24 |
The question of whether SPA-OLs should be placed in the ciliary sulcus is not decisively answered in the peer reviewed literature. Many previous reports have been case reports[7,8,12-17], or are comprised of patients referred to tertiary care centers for management of complications[6,11,18-20]. This case series shows that good corrected visual acuity can be achieved with sulcus placed IOLs of either SPA or three-piece type, however, visual recovery was prolonged in several cases using both types of IOL. Secondary intervention was needed in 20% of cases (two of eight eyes) after SPA-IOL. Importantly, this case series is not based on referral to a tertiary care center for complications associated with the procedure and may therefore represent an unbiased look at a controversial issue.
We believe that SPA-IOL rotation, even months after implantation, did occur in some patients and resulted in unstable manifest refraction in at least one patient who had received an AcrySof® toric SN60T5 lens (Alcon, Ft. Worth, Tx). The AcrySof® SPA-IOL has a diameter of 13 mm from end to end and is thus shorter than the ciliary sulcus diameter of most eyes. There is no accurate way to estimate the ciliary sulcus diameter by external measurements. In addition, the horizontal sulcus diameter is typically shorter than the vertical diameter[21]. Therefore, an initially well centered SPA-IOL in the sulcus may later decenter following rotation into a wider sulcus meridian, unless reverse optic capture can be achieved[22]. SPA-IOL decentration after initial correct placement is particularly undesirable in patients with high visual expectations after premium (toric or multifocal) IOL implantation. Given the possibility of rotation after sulcus implantation of toric SPA IOL, it appears preferable to instead implant an alternate three-piece lens combined with other methods of astigmatism correction such as limbal relaxing incisions. Suture fixation of SPA IOL has been reported to result in stable lens position in the literature but was not attempted our cases.
Placement of any posterior chamber IOL in the ciliary sulcus carries increased risk for complications such as pigment dispersion due to IOL proximity to the iris[23]. A three-piece posterior chamber IOL with posterior angulation of the haptics will move the optic away from the posterior pigment epithelium of the iris. Additionally, a three-piece IOL with a relatively thin optic edge and small, round haptics will reduce potential problems related to iris chafing when placed in the sulcus. The full picture of uveitis-glaucoma-hyphema syndrome was not observed in our case series, though pigment dispersion and iris transillumination defects were noted in three of eight patients with SPA-IOLs and in none of the eyes with 3P-IOLs. Perhaps more importantly, chronic secondary glaucoma developed in several patients with SPA-IOL, although it is unclear whether this was a direct result of pigment dispersion alone. None of the patients in this series underwent IOL exchange as of their most recent follow-up. It should be noted that this study includes a relatively small number of patients and is retrospective in nature. As such, it may lack sufficient power to definitively demonstrate differences between the two IOLs implanted in the cilliary sulcus.
A recent report on complications after SPA-IOL implantation into the sulcus[6] and the corresponding editorial[24] provide a comprehensive review and discussion of associated risks, complications, and management of complications. Surgical alternatives for SPA-IOL placement in the sulcus are detailed and discussed in that publication. Technological advancement in cataract surgery has raised today’s patients’ and surgeons’ expectations for an elegant, fast surgery followed by a smooth postoperative course and rapid visual recovery. While posterior capsular rupture inherently leads to a more complex surgery, our results suggest that a three-piece IOL in the sulcus is preferred over an SPA-IOL in such situations. New developments in IOL design may allow reliable use of SPA-IOL in the sulcus[25].
The author wishes to thank the faculty, residents and staff of the ophthalmology section at the Bruce W Carter VA Hospital for their continued support and engaged discussion during the preparation of this manuscript.
Single-piece acrylic intraocular lenses (SPA-IOL) implants are FDA approved for in the bag placement. There is controversy about the SPA-IOL placement in the ciliary sulcus when in the bag placement is not feasible. Surgeons at tertiary centers advocate categorical IOL exchange to achieve stable IOL position and eliminate IOL induced complications such as iris chaffing, uveitis-glaucoma-hyphema syndrome, fluctuating visual acuity, glaucoma and others.
The clinical course after sulcus placed SPA-IOL is not known. The experience with sulcus placed SPA-IOL at tertiary care centers is hampered by selection bias due to referral of more complicated cases. This retrospective case series offers an unbiased evaluation of sulcus placed SPA-IOLs compared to the alternative three-piece IOL (3P-IOL) placement.
With the introduction of small incision phacoemulsification and premium IOLs not necessitating wound enlargement for IOL inserting, the temptation exists to use a SPA-IOL in the sulcus. This off label use does not achieve as stable a placement as when positioned in the capsular bag. Postoperative prevalence of cystoid macula edema, pigment dispersion, and need for glaucoma medications is increased after sulcus placed SPA-IOL compared to 3PA-IOL. IOL exchange can be deferred on a case by case basis.
This retrospective study illustrates the sequelae of SPA-IOL placement in the sulcus and clinical results in eyes were IOL exchange was not pursued.
The terminology used here should be familiar to any eye care specialist.
This paper is interesting and can be accepted.
P- Reviewer: Wang JK S- Editor: Song XX L- Editor: A E- Editor: Lu YJ
1. | Alcon Ip. Alcon world wide site: Surgical. Hünenberg, Switzerland: Novartis 2012; . [Cited in This Article: ] |
2. | Robert MC, Harasymowycz P. Intraocular lens position following in-the-bag implantation of single-piece versus three-piece acrylic intraocular lenses. Ophthalmic Surg Lasers Imaging. 2012;43:472-478. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 4] [Cited by in F6Publishing: 4] [Article Influence: 0.3] [Reference Citation Analysis (0)] |
3. | Alcon Ip. Acrysof iol product catalog. USA: Alcon Inc 2009; . [Cited in This Article: ] |
4. | Bilge AH, Aykan U, Akin T, Unsal U. The effects of three-piece or single-piece acrylic intraocular lens implantation on posterior capsule opacification. Eur J Ophthalmol. 2004;14:375-380. [PubMed] [Cited in This Article: ] |
5. | Apple DJ, Peng Q, Visessook N, Werner L, Pandey SK, Escobar-Gomez M, Ram J, Auffarth GU. Eradication of posterior capsule opacification: documentation of a marked decrease in Nd: YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem. Ophthalmology. 2001;108:505-518. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 204] [Cited by in F6Publishing: 209] [Article Influence: 9.1] [Reference Citation Analysis (0)] |
6. | Chang DF, Masket S, Miller KM, Braga-Mele R, Little BC, Mamalis N, Oetting TA, Packer M. Complications of sulcus placement of single-piece acrylic intraocular lenses: recommendations for backup IOL implantation following posterior capsule rupture. J Cataract Refract Surg. 2009;35:1445-1458. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 121] [Cited by in F6Publishing: 136] [Article Influence: 9.1] [Reference Citation Analysis (0)] |
7. | Taskapili M, Gulkilik G, Kocabora MS, Ozsutcu M, Yilmazli C, Kaya G, Kucuksahin H. Comparison of sulcus implantation of single-piece hydrophilic foldable acrylic and polymethylmethacrylate intraocular lenses in eyes with posterior capsule tear during phacoemulsification surgery. Eur J Ophthalmol. 2007;17:595-600. [PubMed] [Cited in This Article: ] |
8. | Taskapili M, Engin G, Kaya G, Kucuksahin H, Kocabora MS, Yilmazli C. Single-piece foldable acrylic intraocular lens implantation in the sulcus in eyes with posterior capsule tear during phacoemulsification. J Cataract Refract Surg. 2005;31:1593-1597. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 18] [Cited by in F6Publishing: 22] [Article Influence: 1.2] [Reference Citation Analysis (0)] |
9. | Wintle R, Austin M. Pigment dispersion with elevated intraocular pressure after AcrySof intraocular lens implantation in the ciliary sulcus. J Cataract Refract Surg. 2001;27:642-644. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 50] [Cited by in F6Publishing: 51] [Article Influence: 2.2] [Reference Citation Analysis (0)] |
10. | LeBoyer RM, Werner L, Snyder ME, Mamalis N, Riemann CD, Augsberger JJ. Acute haptic-induced ciliary sulcus irritation associated with single-piece AcrySof intraocular lenses. J Cataract Refract Surg. 2005;31:1421-1427. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 71] [Cited by in F6Publishing: 56] [Article Influence: 2.9] [Reference Citation Analysis (0)] |
11. | Masket S. Pseudophakic posterior iris chafing syndrome. J Cataract Refract Surg. 1986;12:252-256. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 95] [Cited by in F6Publishing: 98] [Article Influence: 2.6] [Reference Citation Analysis (0)] |
12. | Micheli T, Cheung LM, Sharma S, Assaad NN, Guzowski M, Francis IC, Norman J, Coroneo MT. Acute haptic-induced pigmentary glaucoma with an AcrySof intraocular lens. J Cataract Refract Surg. 2002;28:1869-1872. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 56] [Cited by in F6Publishing: 58] [Article Influence: 2.6] [Reference Citation Analysis (0)] |
13. | Uy HS, Chan PS. Pigment release and secondary glaucoma after implantation of single-piece acrylic intraocular lenses in the ciliary sulcus. Am J Ophthalmol. 2006;142:330-332. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 31] [Cited by in F6Publishing: 32] [Article Influence: 1.8] [Reference Citation Analysis (0)] |
14. | Bar-Sela SM, Fleissig E. Intermediate term follow-up after a single-piece-acrylic intraocular lens implantation in the ciliary sulcus- a cross-sectional study. BMC Ophthalmol. 2013;13:76. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 4] [Cited by in F6Publishing: 6] [Article Influence: 0.5] [Reference Citation Analysis (0)] |
15. | Renieri G, Herzog D, Niemann S, Becker M, Kurz S, Thieme H. Sulcus implantation of a single-piece foldable acrylic intraocular lens after posterior capsular rupture in cataract surgery. Eur J Ophthalmol. 2012;22:950-955. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 4] [Cited by in F6Publishing: 5] [Article Influence: 0.4] [Reference Citation Analysis (0)] |
16. | Rosenthal KJ, Venkateswaran N. Transillumination defects following in-the-bag single-piece intraocular lens implantation and trabeculectomy with mini-shunt. J Cataract Refract Surg. 2013;39:139-141. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 0.1] [Reference Citation Analysis (0)] |
17. | Klein JP, Torun N, Berndt S, Rieck P, Bertelmann E. [Early in-the-bag spontaneous intraocular lens dislocation of hydrophilic acryl single piece lenses following uncomplicated phacoemulsification]. Ophthalmologe. 2012;109:54-58. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 3] [Cited by in F6Publishing: 3] [Article Influence: 0.3] [Reference Citation Analysis (0)] |
18. | Bhattacharjee S, Chakrabarti A, Ghosh A. Minimally invasive relocation of subluxated single piece AcrySof intraocular lens. Br J Ophthalmol. 2008;92:746. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 5] [Cited by in F6Publishing: 5] [Article Influence: 0.3] [Reference Citation Analysis (0)] |
19. | Mamalis N, Davis B, Nilson CD, Hickman MS, Leboyer RM. Complications of foldable intraocular lenses requiring explantation or secondary intervention--2003 survey update. J Cataract Refract Surg. 2004;30:2209-2218. [PubMed] [Cited in This Article: ] |
20. | Kohnen T, Kook D. Solving intraocular lens-related pigment dispersion syndrome with repositioning of primary sulcus implanted single-piece IOL in the capsular bag. J Cataract Refract Surg. 2009;35:1459-1463. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 16] [Cited by in F6Publishing: 19] [Article Influence: 1.3] [Reference Citation Analysis (0)] |
21. | Oh J, Shin HH, Kim JH, Kim HM, Song JS. Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy. Ophthalmology. 2007;114:1685-1688. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 70] [Cited by in F6Publishing: 86] [Article Influence: 5.1] [Reference Citation Analysis (0)] |
22. | Jones JJ, Oetting TA, Rogers GM, Jin GJ. Reverse optic capture of the single-piece acrylic intraocular lens in eyes with posterior capsule rupture. Ophthalmic Surg Lasers Imaging. 2012;43:480-488. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 12] [Cited by in F6Publishing: 13] [Article Influence: 1.1] [Reference Citation Analysis (0)] |
23. | Vasavada AR, Raj SM, Karve S, Vasavada V, Vasavada V, Theoulakis P. Retrospective ultrasound biomicroscopic analysis of single-piece sulcus-fixated acrylic intraocular lenses. J Cataract Refract Surg. 2010;36:771-777. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 13] [Cited by in F6Publishing: 14] [Article Influence: 1.0] [Reference Citation Analysis (0)] |
24. | Mamalis N. Sulcus placement of single-piece acrylic intraocular lenses. J Cataract Refract Surg. 2009;35:1327-1328. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 10] [Cited by in F6Publishing: 7] [Article Influence: 0.5] [Reference Citation Analysis (0)] |
25. | Roshdy MM, Riad RF, Morkos FF, Hassouna AK, Wahba SS. Effect of a single-piece aspheric hydrophobic acrylic intraocular lens design on centration and rotation. J Cataract Refract Surg. 2013;39:408-413. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 8] [Cited by in F6Publishing: 10] [Article Influence: 0.9] [Reference Citation Analysis (0)] |