Review
Copyright ©The Author(s) 2020.
World J Orthop. Jun 18, 2020; 11(6): 285-293
Published online Jun 18, 2020. doi: 10.5312/wjo.v11.i6.285
Table 1 Compared to Placebo
YearRef.Sur-gical proce-dureDevice and fre-quencyPeak ampli-tude inten-sityDaily PEMF expo-sure (h/die)Treat-ment PeriodAll+-Mean Age (yr)Follow up (mo)PainSwell-ingMobi-lityQuality of life
1993Ken-nedy et al[48]THA (cemented)Stimatic 3000 75 HzNS7,56 mo371918686 (12, 18, 24, 36)HOS ↑NSROM ↑ HOS ↑NS
1997Pado-vani et al[46]THA and revisionNSNS810 wk1298940666 (20 average)PMA ↑NSPMA ↑NS
2009Dallari et al[50]THA revisionBiostim 75 Hz2 ± 0.2 mT63 mo30151568.6 ± 6.53PMA ↑NSPMA ↑NS
2012Moretti et al[51]TKAI-ONE 75 Hz1.5 mT42 mo30151560-851VAS ↓NSNS
2VAS ↓ KSS ↑KSS ↑SF36 ↑
6VAS ↓ KSS ↑NSKSS ↑SF36 ↑
12VAS ↓NSKSS ↑SF36 ↑
2014Adra-vanti et al[52]TKAI-ONE 75 Hz1.5 ± 0.1 mT42 mo29121773.71VAS ↓ KSS ↑KSS ↑SF36 ↑
2, 6VAS ↓NSNSNS
2019La Verde et al[53]RSAI-ONE 75 Hz1.5 mT42 mo50252560-751VAS ↓ CMS ↑NSCMS ↑NS
2VAS ↓ CMS ↑NSCMS ↑NS
3 (6)VAS ↓ CMS ↑NSCMS ↑NS