For: Klerken T, Mohaddes M, Nemes S, Kärrholm J. High early migration of the revised acetabular component is a predictor of late cup loosening: 312 cup revisions followed with radiostereometric analysis for 2-20 years.Hip Int. 2015;25:471-476. [PMID: 25952912 DOI: 10.5301/hipint.5000246] [Cited by in Crossref: 24] [Cited by in F6Publishing: 14] [Article Influence: 4.0] [Reference Citation Analysis]
Number Citing Articles
1 Tsikandylakis G, Mortensen KRL, Gromov K, Troelsen A, Malchau H, Mohaddes M. The Use of Porous Titanium Coating and the Largest Possible Head Do Not Affect Early Cup Fixation: A 2-Year Report from a Randomized Controlled Trial. JB JS Open Access 2020;5:e20. [PMID: 33376932 DOI: 10.2106/JBJS.OA.20.00107] [Reference Citation Analysis]
2 Mjöberg B. Does particle disease really exist?Acta Orthop. 2018;89:130-132. [PMID: 28914108 DOI: 10.1080/17453674.2017.1373491] [Cited by in Crossref: 1] [Cited by in F6Publishing: 2] [Article Influence: 0.3] [Reference Citation Analysis]
3 Kim YS, Abrahams JM, Callary SA, De Ieso C, Costi K, Howie DW, Solomon LB. Proximal translation of > 1 mm within the first two years of revision total hip arthroplasty correctly predicts whether or not an acetabular component is loose in 80% of cases: a case-control study with confirmed intra-operative outcomes. The Bone & Joint Journal 2017;99-B:465-74. [DOI: 10.1302/0301-620x.99b4.bjj-2016-0805.r1] [Cited by in Crossref: 10] [Article Influence: 2.5] [Reference Citation Analysis]
4 Cleemann R, Sorensen M, West A, Soballe K, Bechtold JE, Baas J. Augmentation of implant surfaces with BMP-2 in a revision setting : effects of local and systemic bisphosphonate. Bone Joint Res 2021;10:488-97. [PMID: 34346256 DOI: 10.1302/2046-3758.108.BJR-2020-0280.R1] [Reference Citation Analysis]
5 Brodén C, Sandberg O, Sköldenberg O, Stigbrand H, Hänni M, Giles JW, Emery R, Lazarinis S, Nyström A, Olivecrona H. Low-dose CT-based implant motion analysis is a precise tool for early migration measurements of hip cups: a clinical study of 24 patients.Acta Orthop. 2020;91:260-265. [PMID: 32056507 DOI: 10.1080/17453674.2020.1725345] [Cited by in Crossref: 4] [Cited by in F6Publishing: 3] [Article Influence: 4.0] [Reference Citation Analysis]
6 Cleemann R, Sorensen M, Bechtold JE, Soballe K, Baas J. Healing in peri-implant gap with BMP-2 and systemic bisphosphonate is dependent on BMP-2 dose-A canine study. J Orthop Res 2018;36:1406-14. [PMID: 28976594 DOI: 10.1002/jor.23766] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 0.3] [Reference Citation Analysis]
7 Solomon LB, Studer P, Abrahams JM, Callary SA, Moran CR, Stamenkov RB, Howie DW. Does cup-cage reconstruction with oversized cups provide initial stability in THA for osteoporotic acetabular fractures? Clin Orthop Relat Res 2015;473:3811-9. [PMID: 26194560 DOI: 10.1007/s11999-015-4460-1] [Cited by in Crossref: 14] [Cited by in F6Publishing: 11] [Article Influence: 2.8] [Reference Citation Analysis]
8 Mjöberg B. Is early migration enough to explain late clinical loosening of hip prostheses?EFORT Open Rev. 2020;5:113-117. [PMID: 32175098 DOI: 10.1302/2058-5241.5.190014] [Cited by in Crossref: 1] [Cited by in F6Publishing: 2] [Article Influence: 1.0] [Reference Citation Analysis]
9 Streit MR, Haeussler D, Bruckner T, Proctor T, Innmann MM, Merle C, Gotterbarm T, Weiss S. Early Migration Predicts Aseptic Loosening of Cementless Femoral Stems: A Long-term Study. Clin Orthop Relat Res 2016;474:1697-706. [PMID: 27130649 DOI: 10.1007/s11999-016-4857-5] [Cited by in Crossref: 31] [Cited by in F6Publishing: 24] [Article Influence: 6.2] [Reference Citation Analysis]
10 Sköldenberg OG, Rysinska AD, Chammout G, Salemyr M, Mukka SS, Bodén H, Eisler T. A randomized double-blind noninferiority trial, evaluating migration of a cemented vitamin E-stabilized highly crosslinked component compared with a standard polyethylene component in reverse hybrid total hip arthroplasty. Bone Joint J 2019;101-B:1192-8. [PMID: 31564144 DOI: 10.1302/0301-620X.101B10.BJJ-2019-0456.R2] [Cited by in Crossref: 10] [Cited by in F6Publishing: 2] [Article Influence: 5.0] [Reference Citation Analysis]
11 Johanson PE, Antonsson M, Shareghi B, Kärrholm J. Early Subsidence Predicts Failure of a Cemented Femoral Stem With Minor Design Changes.Clin Orthop Relat Res. 2016;474:2221-2229. [PMID: 27188836 DOI: 10.1007/s11999-016-4884-2] [Cited by in Crossref: 10] [Cited by in F6Publishing: 9] [Article Influence: 2.5] [Reference Citation Analysis]
12 Abrahams JM, Callary SA, Jang SW, Hewitt J, Howie DW, Solomon LB. Accuracy of EBRA-cup measurements after reconstruction of severe acetabular defects at revision THR. J Orthop Res 2020;38:1497-505. [PMID: 32039492 DOI: 10.1002/jor.24623] [Cited by in Crossref: 8] [Cited by in F6Publishing: 6] [Article Influence: 8.0] [Reference Citation Analysis]
13 Galea VP, Rojanasopondist P, Laursen M, Muratoglu OK, Malchau H, Bragdon C. Evaluation of vitamin E-diffused highly crosslinked polyethylene wear and porous titanium-coated shell stability: a seven-year randomized control trial using radiostereometric analysis. Bone Joint J 2019;101-B:760-7. [PMID: 31256674 DOI: 10.1302/0301-620X.101B7.BJJ-2019-0268.R1] [Cited by in Crossref: 17] [Cited by in F6Publishing: 3] [Article Influence: 8.5] [Reference Citation Analysis]
14 Mjöberg B. Hip prosthetic loosening: A very personal review. WJO 2021;12:629-39. [DOI: 10.5312/wjo.v12.i9.629] [Reference Citation Analysis]