Topic Highlight
Copyright ©2014 Baishideng Publishing Group Inc.
World J Radiol. Jul 28, 2014; 6(7): 417-423
Published online Jul 28, 2014. doi: 10.4329/wjr.v6.i7.417
Table 1 Specificity and sensitivity for predicting inferior alveolar nerve injury with third molar surgery
Imaging procedureSensitivitySpecificity
Orthopantomography[22-26]
Darkening of the root32%-71%73%-96%
Interruption of the canal22%-80%47%-97%
Diversion of the canal3%-50%82%-100%
CT/Cone-beam CT[1,38,41,42]
Cortication66%-100%46%-86%