Table 1 Susceptibility weighted imaging sequence parameters for 1.5 T Siemens Magnetom Avanto syngo magnet
Slab group 1 | |
Slabs | 1 |
Dist. factor | 20% |
Position | L0.0 A16.0 H37.8 |
Orientation | T > C-6.9 |
Phase enc. dir. | R >> L |
Rotation | 90.00 deg |
Phase oversampling | 0% |
Slibe oversampling | 23.10% |
Slices per slab | 104 |
FoV read | 230 mm |
FoV phase | 75% |
Slice thickness | 1.50 mm |
TR | 28 ms |
TE | 20.00 ms |
Averages | 1 |
Concatenations | 1 |
Filter | Prescan normalize |
Matrix size | 256 × 256 |
TA | 4.44 |
PAT | 2 |
Voxel size | 1.0 mm × 0.9 mm × 1.5 mm |
Flip angle | 15 deg |
Dimension | 3D |
Bandwidth | 120 Hz/Px |
Slice resolution | 100% |
Coil elements | HE1-4 |
Table 2 Susceptibility weighted imaging sequence parameters for 3 T Siemens Magnetom TrioTim syngo magnet
Slab group 1 | |
Slabs | 1 |
Dist. factor | 20% |
Position | L0.0 A16.0 H37.8 |
Orientation | T > C-6.9 |
Phase enc. dir. | R >> L |
Rotation | 90.00 deg |
Phase oversampling | 0% |
Slibe oversampling | 23.10% |
Slices per slab | 104 |
FoV read | 230 mm |
FoV phase | 75% |
Slice thickness | 1.50 mm |
TR | 28 ms |
TE | 20.00 ms |
Averages | 1 |
Concatenations | 1 |
Filter | Prescan normalize |
Matrix size | 256 × 256 |
TA | 4.44 |
PAT | 2 |
Voxel size | 1.0 mm × 0.9 mm × 1.5 mm |
Flip angle | 15 deg |
Dimension | 3D |
Bandwidth | 120 Hz/Px |
Slice resolution | 100% |
Coil elements | HEA; HEP; NE1, 2 |
Table 3 Susceptibility weighted imaging sequence parameters for 1.5 T Philips Achieva magnet
FoV read | 230 mm |
Slice thickness | 5 mm |
Gap | 0 |
TR | 35 ms |
TE | 50 ms |
Matrix size | 256 x 512 |
TA | 5.15 |
Flip angle | 15 deg |
Coil elements | 8 channel SENSE head coil |
Table 4 Susceptibility weighted imaging sequence parameters for 3 T Philips Achieva magnet
FoV read | 230 mm |
Slice thickness | 5 mm |
Gap | 0 |
TR | 23 ms |
TE | 20 ms |
Matrix size | 218 × 127 |
TA | 4.08 |
Flip angle | 10 deg |
Coil elements | 8 channel SENSE head coil |
Table 5 Increased iron levels in the central nervous system
Entity | Increased iron location | Ref. |
Parkinson’s disease | SN, pars compacta, brainstem | [53] |
Alzheimer’s disease | Hippocampus, GP | [54] |
PKAN | GP, SN sparing DN | [55] |
Infantile neuroaxonal dystrophy | GP, SN, DN | [55] |
Neuroferritinopathy | GP, P, DN with cavitation | [55] |
Aceruloplasminemia | BG, thalami with no cavitation | [55] |
Huntington’s disease | CN, P | [56] |
Progressive MCI versus stable MCI | Right GP, SN | [57] |
Multiple sclerosis | CN, P and thalamic pulvinar | [60] |