Copyright
©The Author(s) 2025.
World J Cardiol. Mar 26, 2025; 17(3): 101709
Published online Mar 26, 2025. doi: 10.4330/wjc.v17.i3.101709
Published online Mar 26, 2025. doi: 10.4330/wjc.v17.i3.101709
Table 1 Review of literature on complications following transfemoral access of graft
Ref. | Type of graft | Closure devices | Complications |
Rosseel et al[1] | Two patients had aortobifemoral bypass grafts | Both patients used the same technique- 2. Perclose devices and 1 additional 6Fr Angioseal (Terumo, Shibuya, Tokyo, Japan) | None |
Wu et al[3] | Aortobifemoral bypass graft | 14F MANTA vascular closure device (Teleflex, Wayne, United States) and 4 Perclose devices | None |
Ezeh et al[26] | Aortobifemoral bypass graft | 2 Perclose devices | None |
Geyer et al[27] | Aortobifemoral bypass graft | 18F MANTA vascular closure device (Teleflex, Wayne, United States) | None |
- Citation: Mustafa A, Wei C, Cinelli M, Khan S, Khan D, Tamburrino F, Maniatis G, Spagnola J. Balloon valvuloplasty and transcatheter aortic valve replacement via aortofemoral bypass grafts: A case report and review of literature. World J Cardiol 2025; 17(3): 101709
- URL: https://www.wjgnet.com/1949-8462/full/v17/i3/101709.htm
- DOI: https://dx.doi.org/10.4330/wjc.v17.i3.101709