Figure 1
Figure 1 Assessment of the calcific aortic valve and interventricular septal aneurysm prior to transcatheter aortic valve replacement. A: Transesophageal echocardiography shows a perimembranous ventricular septal aneurysm (arrow) and severe calcific stenotic aortic valve with moderate aortic regurgitation; B: Cardiac computer tomography (CT) findings confirmed the focal interventricular septal aneurysm (arrow) below the aortic annulus in the transverse view along the membranous septum with left ventricular outflow tract extension (arrowhead); C: Cardiac CT in coronal view showing interventricular septal aneurysm (arrow) below the annulus; D: The dimension at the neck of septal aneurysm (arrow) was 14.5 mm on 3-D reconstructed CT image; E and F: The aortic annulus to left main ostium distance was 12.9 mm and annulus to right coronary ostium distance was 18.9 mm.
Figure 2
Figure 2 Measurements below and at the level of aortic annulus. A: The aortic measurements included area of 571.8 mm[2]; B: Perimeter of 85 mm at 0.2 mm below the level of annulus, and also at 4.1 mm below the annulus and at level of aneurysm.
Figure 3
Figure 3 Post deployment assessment of the 29 mm Edwards SAPIEN XT valve at aortic position. A: Deployment of the 29 mm Edwards SAPIEN XT valve at the level of tip of pig tail catheter; B: Immediately after deployment of 29 mm Edwards SAPIEN XT valve, TEE shows color doppler signals in interventricular septal aneurysm (arrows); C: Follow up cardiac computer tomography showed stable prosthetic valve and interventricular septal aneurysm (arrow).