Author | Patients | P - palliative disease | I - intervention | C - control | O - outcomes |
Davids et al[15], 1992 | 105 | MBDO | 49 | 56 | Stent dysfunction, mean survival, duration of patency, complications, reinterventions, clinical success |
8-10 mm wallstent | 10 Fr PS straight | ||||
Knyrim et al[21], 1993 | 62 | MBDO | 31 | 31 | Complications, stent dysfunctions, reinterventions, clinical success |
8 mm wallstent ou strecket stent (1 or 2) | 11,5 Fr PS If it fails à 14 Fr percutaneous technique | ||||
Prat et al[14], 1998 | 1051 | MBDO | 34 | 2 groups: 33/34 | Stent dysfunction, reinterventions |
10 mm wallstent | 11,5 Fr PS | ||||
Kaassis et al[19], 2003 | 118 | MBDO | 59 | 59 | Stent dysfunction, reinterventions, complications |
10 mm wallstent | 10 Fr Tannenbaum PS | ||||
Katsinelos et al[20], 2006 | 47 | MBDO | 23 | 24 | Stent dysfunction, Mean survival, complications, reinterventions, duration of patency, clinical success |
10 mm uSEMS | 10 Fr Tannenbaum PS straight | ||||
Soderlund et al[16], 2006 | 100 | MBDO | 49 | 51 | Mean survival, reinterventions, duration of patency, complications, mean survival, clinical success |
10 mm cSEMS | 10 Fr PS | ||||
Isayama et al[18], 2011 | 120 | MBDO | 60 | 60 | Mean survival, complication, stent dysfunction, reinterventions, duration of patency |
cSEMS | 10 Fr Stent Double Layer | ||||
Moses et al[13], 2013 | 85 | MBDO | 42 | 43 | Mean survival, duration of patency, complications, stent dysfunction, clinical success |
10 mm pcSEMS | 10 Fr Amsterdam PS | ||||
Schmidt et al[12], 2015 | 37 | MBDO | 19 | 18 | Stent dysfunction, complications. |
10 mm uSEMS, cSEMS or pcSEMS | 10 Fr ViaDuct Stent (PS wing) | ||||
Walter et al[10], 2015 | 2401 | MBDO | uSEMS: 75 / pcSEMS: 73 | 73 | Stent dysfunction, mean survival, complications, duration of patency, clinical success |
10 mm uSEMS or pcSEMS Wallstent RX | 10 Fr PS Polyethylene or polyurethan | ||||
Walter et al[11], 2017 | 2401 | MBDO | uSEMS: 75 / pcSEMS: 73 | 73 | Stent dysfunction, duration of patency, mean survival |
10 mm uSEMS or pcSEMS Wallstent RX | 10 Fr PS Polyethylene or polyurethan | ||||
Bernon et al[17], 2018 | 40 | MBDO | 19 | 21 | Stent dysfunction, duration of patency, complications, clinical success |
10 mm uSEMS | 10 Fr PS polyethylene |
- Citation: Scatimburgo MVCV, Ribeiro IB, de Moura DTH, Sagae VMT, Hirsch BS, Boghossian MB, McCarty TR, dos Santos MEL, Franzini TAP, Bernardo WM, de Moura EGH. Biliary drainage in inoperable malignant biliary distal obstruction: A systematic review and meta-analysis. World J Gastrointest Surg 2021; 13(5): 493-506