Manufacterer | Model | Material | Deployed diameters (mm) and lengths (cm) |
Boston scientific | Fully covered Wallflex | Platinol covered with permalume | 8 or 10 mm |
4, 6, 8 cm | |||
Taewoong Medical | S-Type fully covered | Nitinol covered with silicone | 6, 8 or 10 mm |
4-15 cm | |||
M.I. Tech | Hanarostent covered, with lasso or with anchoring flaps | Nitinol covered with silicone | 10 mm |
4-10 cm | |||
Standard SciTech | Biliary covered Bonastent with flared ends | Nitinol covered with silicone | 10 mm |
4-10 cm | |||
Ella-CS | Nitinella plus | Nitinol covered with silicone | 8 or 10 mm |
4-6-8-10 cm | |||
ConMed | Gore viabil with or without holes and with fins | Nitinol covered with ePTFE/FEP (gore tex) | 8 or 10 mm |
4-6-8-10 cm |
Treatment of benign biliary strictures |
- Postcholecystectomy |
- Post liver transplantation |
- Chronic pancreatitis |
- Papillary stenosis |
- Bile duct stones and cholangitis |
- Parasitic biliary infections |
-Other forms of surgical biliary interventions and less frequent medical diseases such as primary sclerosing cholangitis or autoimmune pancreatitis |
Treatment of biliary leaks |
Sealing of papillary area perforations and bleeding after ERCP and biliary sphincterotomy |
Extraction of biliary uncovered SEMS |
EUS-guided biliary drainage |
Author | No. ofpatients | Type ofstent | BBS etiology | Mean time to removal (mo) | Clinical success (%) |
Cantu[22] | 14 | PCSEMS | CP | 21 | 37.50 |
Kahaleh[23] | 79 | PCSEMS | CP/OLT/BS/IM/PS | 4 | 90 |
Mahajan[24] | 44 | FCSEMS | CP/OLT/BS/IM/PS | 3.3 | 83 |
Traina[25] | 16 | FCSEMS | OLT/LRLT | 2 | 81 |
Park[13] | 43 | FCSEMS | CP/OLT/BS/PS | 6 | 84 |
García- ano[26] | 14 | FCSEMS | IM/BS | 5.5 | 78.50 |
Chaput[10] | 22 | PCSEMS | OLT | 2 | 52.60 |
García-Pajares[27] | 22 | FCSEMS | OLT | 3.2 | 95.50 |
Behm[28] | 22 | PCSEMS | CP | 5 | 72.70 |