For: Zhang GG, Latifi K, Du K, Reinhardt JM, Christensen GE, Ding K, Feygelman V, Moros EG. Evaluation of the ΔV 4D CT ventilation calculation method using in vivo xenon CT ventilation data and comparison to other methods. J Appl Clin Med Phys 2016;17:550-60. [PMID: 27074479 DOI: 10.1120/jacmp.v17i2.5985] [Cited by in Crossref: 10] [Cited by in F6Publishing: 10] [Article Influence: 1.4] [Reference Citation Analysis]
Number Citing Articles
1 Katsuta Y, Kadoya N, Kajikawa T, Mouri S, Kimura T, Takeda K, Yamamoto T, Imano N, Tanaka S, Ito K, Kanai T, Nakajima Y, Jingu K. Radiation pneumonitis prediction model with integrating multiple dose-function features on 4DCT ventilation images. Phys Med 2023;105:102505. [PMID: 36535238 DOI: 10.1016/j.ejmp.2022.11.009] [Reference Citation Analysis]
2 Katsuta Y, Kadoya N, Mouri S, Tanaka S, Kanai T, Takeda K, Yamamoto T, Ito K, Kajikawa T, Nakajima Y, Jingu K. Prediction of radiation pneumonitis with machine learning using 4D-CT based dose-function features. J Radiat Res 2021:rrab097. [PMID: 34718683 DOI: 10.1093/jrr/rrab097] [Reference Citation Analysis]
3 Feng A, Shao Y, Wang H, Chen H, Gu H, Duan Y, Gan W, Xu Z. A novel lung-avoidance planning strategy based on 4DCT ventilation imaging and CT density characteristics for stage III non-small-cell lung cancer patients. Strahlenther Onkol 2021. [PMID: 34351454 DOI: 10.1007/s00066-021-01821-1] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 0.5] [Reference Citation Analysis]
4 Shao W, Patton TJ, Gerard SE, Pan Y, Reinhardt JM, Durumeric OC, Bayouth JE, Christensen GE. N-Phase Local Expansion Ratio for Characterizing Out-of-Phase Lung Ventilation. IEEE Trans Med Imaging 2020;39:2025-34. [PMID: 31899418 DOI: 10.1109/TMI.2019.2963083] [Cited by in Crossref: 6] [Cited by in F6Publishing: 6] [Article Influence: 1.5] [Reference Citation Analysis]
5 Hegi-johnson F, de Ruysscher D, Keall P, Hendriks L, Vinogradskiy Y, Yamamoto T, Tahir B, Kipritidis J. Imaging of regional ventilation: Is CT ventilation imaging the answer? A systematic review of the validation data. Radiotherapy and Oncology 2019;137:175-85. [DOI: 10.1016/j.radonc.2019.03.010] [Cited by in Crossref: 14] [Cited by in F6Publishing: 14] [Article Influence: 3.5] [Reference Citation Analysis]
6 Tahir BA, Hughes PJ, Robinson SD, Marshall H, Stewart NJ, Norquay G, Biancardi A, Chan H, Collier GJ, Hart KA, Swinscoe JA, Hatton MQ, Wild JM, Ireland RH. Spatial Comparison of CT-Based Surrogates of Lung Ventilation With Hyperpolarized Helium-3 and Xenon-129 Gas MRI in Patients Undergoing Radiation Therapy. International Journal of Radiation Oncology*Biology*Physics 2018;102:1276-86. [DOI: 10.1016/j.ijrobp.2018.04.077] [Cited by in Crossref: 23] [Cited by in F6Publishing: 24] [Article Influence: 4.6] [Reference Citation Analysis]
7 Otsuka M, Monzen H, Matsumoto K, Tamura M, Inada M, Kadoya N, Nishimura Y. Evaluation of lung toxicity risk with computed tomography ventilation image for thoracic cancer patients. PLoS One 2018;13:e0204721. [PMID: 30281625 DOI: 10.1371/journal.pone.0204721] [Cited by in Crossref: 5] [Cited by in F6Publishing: 6] [Article Influence: 1.0] [Reference Citation Analysis]
8 Kanai T, Kadoya N, Nakajima Y, Miyasaka Y, Ieko Y, Kajikawa T, Ito K, Yamamoto T, Dobashi S, Takeda K, Nemoto K, Jingu K. Evaluation of functionally weighted dose-volume parameters for thoracic stereotactic ablative radiotherapy (SABR) using CT ventilation. Phys Med 2018;49:47-51. [PMID: 29866342 DOI: 10.1016/j.ejmp.2018.05.001] [Cited by in Crossref: 3] [Cited by in F6Publishing: 3] [Article Influence: 0.6] [Reference Citation Analysis]
9 Zhang GG, Latifi K, Feygelman V, Dilling TJ, Moros EG. 4DCT-Derived Ventilation Distribution Reproducibility Over Time. Biomedical Engineering Systems and Technologies 2017. [DOI: 10.1007/978-3-319-54717-6_4] [Reference Citation Analysis]
10 Zhang GG, Latifi K, Feygelman V, Chou K, Huang T, Dilling TJ, Perez BA, Moros EG. Ventilation Series Similarity: A Study for Ventilation Calculation Using Deformable Image Registration and 4DCT to Avoid Motion Artifacts. Contrast Media & Molecular Imaging 2017;2017:1-7. [DOI: 10.1155/2017/9730380] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 0.2] [Reference Citation Analysis]
11 Ireland R, Tahir B, Wild J, Lee C, Hatton M. Functional Image-guided Radiotherapy Planning for Normal Lung Avoidance. Clinical Oncology 2016;28:695-707. [DOI: 10.1016/j.clon.2016.08.005] [Cited by in Crossref: 35] [Cited by in F6Publishing: 33] [Article Influence: 5.0] [Reference Citation Analysis]