BPG is committed to discovery and dissemination of knowledge
Cited by in F6Publishing
For: Zhong X, Armstrong T, Nickel MD, Kannengiesser SAR, Pan L, Dale BM, Deshpande V, Kiefer B, Wu HH. Effect of respiratory motion on free-breathing 3D stack-of-radial liver R 2 relaxometry and improved quantification accuracy using self-gating. Magn Reson Med 2020;83:1964-78. [PMID: 31682016 DOI: 10.1002/mrm.28052] [Cited by in Crossref: 7] [Cited by in F6Publishing: 4] [Article Influence: 2.3] [Reference Citation Analysis]
Number Citing Articles
1 Peng H, Cheng C, Wan Q, Jia S, Wang S, Lv J, Liang D, Liu W, Liu X, Zheng H, Zou C. Fast multi-parametric imaging in abdomen by B 1 + corrected dual-flip angle sequence with interleaved echo acquisition. Magn Reson Med 2021. [PMID: 34888911 DOI: 10.1002/mrm.29127] [Reference Citation Analysis]
2 Zhong X, Armstrong T, Gao C, Nickel MD, Han F, Dale BM, Li X, Kafali SG, Hu P, Wu HH, Deshpande V. Accelerated k-space shift calibration for free-breathing stack-of-radial MRI quantification of liver fat and R 2 . Magn Reson Med 2022;87:281-91. [PMID: 34412158 DOI: 10.1002/mrm.28981] [Reference Citation Analysis]
3 Starekova J, Zhao R, Colgan TJ, Johnson KM, Rehm JL, Wells SA, Reeder SB, Hernando D. Improved free-breathing liver fat and iron quantification using a 2D chemical shift–encoded MRI with flip angle modulation and motion-corrected averaging. Eur Radiol. [DOI: 10.1007/s00330-022-08682-x] [Reference Citation Analysis]
4 Zhong X, Hu HH, Armstrong T, Li X, Lee Y, Tsao T, Nickel MD, Kannengiesser SA, Dale BM, Deshpande V, Kiefer B, Wu HH. Free‐Breathing Volumetric Liver and Proton Density Fat Fraction Quantification in Pediatric Patients Using Stack‐of‐Radial MRI With Self‐Gating Motion Compensation. J Magn Reson Imaging 2021;53:118-29. [DOI: 10.1002/jmri.27205] [Cited by in Crossref: 6] [Cited by in F6Publishing: 3] [Article Influence: 3.0] [Reference Citation Analysis]
5 Rohani SC, Morin CE, Zhong X, Kannengiesser S, Shrestha U, Goode C, Holtrop J, Khan A, Loeffler RB, Hankins JS, Hillenbrand CM, Tipirneni-Sajja A. Hepatic Iron Quantification Using a Free-Breathing 3D Radial Gradient Echo Technique and Validation With a 2D Biopsy-Calibrated R2 * Relaxometry Method. J Magn Reson Imaging 2021. [PMID: 34545639 DOI: 10.1002/jmri.27921] [Cited by in Crossref: 1] [Article Influence: 1.0] [Reference Citation Analysis]
6 Wang N, Cao T, Han F, Xie Y, Zhong X, Ma S, Kwan A, Fan Z, Han H, Bi X, Noureddin M, Deshpande V, Christodoulou AG, Li D. Free-breathing multitasking multi-echo MRI for whole-liver water-specific T1 , proton density fat fraction, and R 2 quantification. Magn Reson Med 2021. [PMID: 34418152 DOI: 10.1002/mrm.28970] [Reference Citation Analysis]
7 Armstrong T, Zhong X, Shih SF, Felker E, Lu DS, Dale BM, Wu HH. Free-breathing 3D stack-of-radial MRI quantification of liver fat and R2* in adults with fatty liver disease. Magn Reson Imaging 2022;85:141-52. [PMID: 34662702 DOI: 10.1016/j.mri.2021.10.016] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 1.0] [Reference Citation Analysis]
8 Li Z, Fu Z, Keerthivasan M, Bilgin A, Johnson K, Galons JP, Vedantham S, Martin DR, Altbach MI. Rapid high-resolution volumetric T1 mapping using a highly accelerated stack-of-stars Look Locker technique. Magn Reson Imaging 2021;79:28-37. [PMID: 33722634 DOI: 10.1016/j.mri.2021.03.003] [Reference Citation Analysis]
9 Schneider M, Benkert T, Solomon E, Nickel D, Fenchel M, Kiefer B, Maier A, Chandarana H, Block KT. Free-breathing fat and R2 * quantification in the liver using a stack-of-stars multi-echo acquisition with respiratory-resolved model-based reconstruction. Magn Reson Med 2020;84:2592-605. [PMID: 32301168 DOI: 10.1002/mrm.28280] [Cited by in Crossref: 4] [Cited by in F6Publishing: 6] [Article Influence: 2.0] [Reference Citation Analysis]