Observational Study
Copyright ©The Author(s) 2017.
World J Gastroenterol. Aug 7, 2017; 23(29): 5422-5430
Published online Aug 7, 2017. doi: 10.3748/wjg.v23.i29.5422
Table 1 Patient and lesion baseline data in the S and F1-10 methods
S method (n = 6)F1-10 method (n = 6)P3 value
Age, median (yr) (range)70 (64-87)71 (53-79)0.81
Sex (male/female)5:14:20.59
Lesion location, U/M/L13/3/04/2/00.64
Histology, well/mod/poor6/0/06/0/01.00
Tumor size, median (mm) (range)13.5 (8-36)16 (6-23)0.60
Resected size, median (mm) (range)50.5 (33-64)44.5 (31-56)0.63
Depth of tumor invasion, M/SM1/SM224/2/03/1/20.42
Median time of treatment (min)6552.50.69
Postoperative bleeding rate001.00
En bloc resection rate100%100%1.00
Table 2 Results of the vessel diameter, frequency of the compressed vessel, and coagulation time in the vessel-sealing with endoknife compression technique during gastric endoscopic submucosal dissection
S methodF1-10 methodP1 value
Number of vessels processed by vessel-sealing4962
with endoknife compression
Median vessel diameter (mm) (range)2 (1-3)1.5 (1-3)0.68
Median frequency of compressed vessel (times) (range)2 (1-8)2 (1-5)0.11
Median time of coagulation (s) (range)9 (2-48)10 (1-58)0.11
Table 3 Rates of bleeding after vessel-sealing with endoknife compression for all vessels and large vessels
S methodF1-10 methodP2 valueOR95%CI
Rate of bleeding16.3% (8/49)4.8% (3/62)0.0583.840.96-15.34
Rate of large vessel bleeding126.9% (7/26)3.4% (1/29)0.02110.321.17-90.78
Table 4 Electrical condition using the FlushKnife-BT in the porcine ex vivo model analyzed by the VIO DOKU
FlushKnife-BT 2.5 mm
S methodF1-10 method
Median peak voltage (Vp)172 (170-173)560 (538-587)
Median current elapse time (s)0.22 (0.20-0.30)1.54 (0.50-1.77)
Median total electric energy (W)6.34 (3.9-8.67)12.5 (3.47-13.8)