Prospective Study
Copyright ©The Author(s) 2015.
World J Gastroenterol. Sep 7, 2015; 21(33): 9785-9792
Published online Sep 7, 2015. doi: 10.3748/wjg.v21.i33.9785
Table 1 Accuracy of diffusion-weighted imaging hyperintensity from different b values for detecting endoscopic inflammation
AUROCSens.Spec.P value
b = 400 s/mm20.63169.048.30.0410
b = 600 s/mm20.73281.762.10.0001
b = 800 s/mm20.86793.079.30.0001
b = 1000 s/mm20.72164.879.30.0010
Table 2 Accuracy of the MR-score-S and seven signs for detecting endoscopic inflammation
ROC analysisAUROCSens.Spec.P value
MR-score-S > 110.92985.982.80.0001
DWI hyperintensity0.86793.079.30.0001
Rapid gadolinium enhancement after intravenous contrast medium administration0.85373.293.10.0001
Bowel wall thickening0.79366.289.70.0001
Differentiation between the mucosa-submucosa complex and the muscularis0.84280.386.20.0001
Parietal edema0.68443.789.70.0040
Ulceration0.77559.293.10.0001
Comb sign0.69443.793.10.0020
Table 3 Correlation of MR-score-T or Baron-T with clinical and biological markers
Activity markersMR-score-T
Baron-T
MR-score-T vs Baron-T
rP value1rP value1P value2
Mayo index0.8310.00010.9260.00010.20
CRP0.6560.00200.8860.00010.07
ESR0.7480.00010.8100.00010.64
Hemoglobin-0.4490.0470-0.5800.00700.60
Leukocytes0.4810.03200.5060.02300.92
Platelets0.4450.04900.5340.01500.73
Serum iron-0.4970.0260-0.5590.01000.80
Albumin-0.4620.0400-0.5070.02200.86