Meta-Analysis
Copyright ©2013 Baishideng Publishing Group Co.
World J Gastroenterol. Dec 7, 2013; 19(45): 8427-8434
Published online Dec 7, 2013. doi: 10.3748/wjg.v19.i45.8427
Table 1 Characteristics of included studies
StudyCountry/yearsNo. of patientsMean ageStudy designMRCP techniqueReference standardQUADASTPFPFNTN
Ayuso et al[9]Spain/200425NSProspectiveMnDPDP-enhanced, MIPIOC1215019
Limanond et al[11]United States/20042637RetrospectiveT2 single-shot fast spin-echo, T2 HASTEIOC1352217
Kim et al[23]Canada/20053036ProspectiveT2 weighted SSFSE, Mn-DPDPIOC12120117
An et al[12]South Korea/20062429ProspectiveGadobenate dimeglumine-enhanced T1-and T2-weighted, MIPIOC1413119
Sirvanci et al[25]Turkey/20076242RetrospectiveRARE, HASTE, 3D TSEIOC13160343
Song et al[26]South Korea/200711129ProspectiveSingle-slab RARE or multislice HASTEIOC12423264
Basaran et al[19]Turkey/20084035ProspectiveT2-weighted PACE turbo spin-echoIOC12133024
Kashyap et al[22]United States/20083638RetrospectiveThick and thin slab heavily T2 weightedIOC14160317
Artioli et al[27]Italy/20103238ProspectiveT2-weightedSurgery11151214
Kim et al[24]South Korea/20105233ProspectiveRARE, 3D SE T2-weighted sequences.IOC14153331
Hsu et al[21]Taiwan/201120332RetrospectiveRARE thin-slabIOC134568144
Chiang et al[20]Taiwan/201222830RetrospectiveT2-weighted GD-DTPAIOC135579157
Table 2 Quality assessment tool for diagnostic accuracy systematic review of quality criteria of included studies
Ayuso et al[9]Limanond et al[11]Kim et al[23]An et al[12]Sirvanci et al[25]Song et al[26]Basaran et al[19]Kashyap et al[22]Artioli et al[27]Kim et al[24]Hsu et al[21]Chiang et al[20]
Patient spectrum representativeYesNAYesYesNAYesYesYesNAYesNANA
Selection criteria describedYesYesYesYesYesYesYesYesYesYesYesYes
Reference standard appropriateYesYesYesYesYesYesYesYesYesYesYesYes
Time between tests appropriateYesYesYesYesYesYesYesYesYesYesYesYes
Uniform verification by reference standardYesYesYesYesYesYesYesYesYesYesYesYes
Same reference test usedYesYesYesYesYesYesYesYesYesYesYesYes
Reference standard independentYesYesYesYesYesYesYesYesYesYesYesYes
Reference standard described adequatelyYesYesYesYesYesYesYesYesYesYesYesYes
Blinding to reference standard resultsNAYesNAYesYesNANAYesNAYesYesYes
Blinding to index test resultsNAYesNAYesYesNANAYesNAYesYesYes
Appropriate clinical data availableYesYesYesYesYesYesYesYesYesYesYesYes
Uninterpretable data reportedYesYesYesYesYesYesYesYesYesYesYesYes
Withdrawals explainedYesYesYesYesYesYesYesYesYesYesYesYes
No. of criteria met out of 14121313141312121411141313