Brief Article
Copyright ©2013 Baishideng Publishing Group Co.
World J Gastroenterol. May 21, 2013; 19(19): 2950-2955
Published online May 21, 2013. doi: 10.3748/wjg.v19.i19.2950
Table 1 Comparison of endoscopy items at three levels of endoscopy units n (%)/(mean ± SD)
Endoscopy unitProvincial (n = 44)Prefecture-level (n = 91)County-level (n = 34)Total (n = 169)
Procedures per year
> 500044 (100.0)15 (16.5)0 (0.0)59 (34.9)
3000-50000 (0.0)65 (71.4)3 (8.8)69 (40.2)
< 30000 (0.0)11 (12.1)31 (91.2)42 (24.9)
Average number of endoscopes22.4 ± 5.5a5.4 ± 1.42.7 ± 1.29.3 ± 3.2
≥ 10 endoscopes/unit26 (59.1)a6 (6.6)0 (0.0)32 (18.9)
Gastroscope44 (100.0)91 (100.0)34 (100.0)169 (100.0)
Colonoscope44 (100.0)a89 (97.8)c30 (88.2)163 (96.4)
DBE/SBE18 (40.9)a0 (0.0)0 (0.0)18 (10.7)
EUS31 (70.5)a7 (7.7)0 (0.0)38 (22.5)
VCE28 (63.6)a7 (7.7)0 (0.0)35 (20.7)
Average number of procedure rooms4.9 ± 1.4a2.6 ± 1.3c1.6 ± 0.83.6 ± 1.8
Average number of full-time physicians3.0 ± 1.3a1.6 ± 1.21.2 ± 0.91.9 ± 1.4
Average number of full-time nurses5.4 ± 1.3a2.2 ± 1.11.3 ± 0.82.8 ± 1.3
X-ray machine19 (43.2)a14 (15.4)c0 (0.0)33 (19.5)
Polypectomy44 (100.0)a71 (78.0)c14 (41.2)129 (76.3)
ERCP34 (77.3)a39 (42.9)c4 (11.8)77 (45.6)
EMR30 (68.2)a20 (22.0)c2 (5.9)52 (30.8)
ESD16 (36.4)a9 (9.9)0 (0.0)25 (14.8)
EVS/EVL33 (75.0)a37 (40.7)c3 (8.8)73 (43.2)
Table 2 Comparison of main endoscopy items in three independent surveys
Endoscopy itemsShanghai survey (2001)Qinghai survey (2003)Present survey (2011)
Number of units138.037.0169.0
Average number of endoscopes/unit3.31.49.3
Possession rate
Gastroscope100.00%100.00%100%
Colonoscope70.30%-97.60%
Enteroscope4.30%0.00%10.60%
EUS7.20%0.00%22.50%
VCE-2.70%20.70%
X-ray machine5.70%-19.50%
Procedures
Polypectomy54.30%-76.30%
EVS/EVL40.20%-43.20%
ERCP38.40%-45.60%