Brief Article
Copyright ©2011 Baishideng Publishing Group Co.
World J Gastroenterol. Apr 7, 2011; 17(13): 1739-1745
Published online Apr 7, 2011. doi: 10.3748/wjg.v17.i13.1739
Table 1 MR-arterioportography standard protocol
ScansPlaneTETRFlip angle
Unenhanced
T2-weighted TRUFICoronal1.93.871°
T2-weighted TRUFITransversal1.883.7671°
T1-weighted VIBETransversal2.024.7810°
Enhanced
T1-weighted FLASH FS CETransversal4.7612370°
T1-weighted VIBE dynamic1Transversal2.024.7810°
Table 2 Magnetic resonance imaging standard protocol
ScansPlaneTETRFlip angle
Unenhanced
T1-weighted VIBETransversal1.594.3710°
T2-star-weighted FLASH 2DTransversal10.00169.0090°
T2-weighted TSE FSTransversal105.002740.00170°
T1-weighted FLASH oppTransversal2.71100.0070°
T1-weighted FLASH inTransversal4.7687.0060°
T2-weighted HASTETransversal85.001000.00150°
T2-weighted TRUFICoronal1.833.6571°
T1-weighted VIBETransversal1.554.8110°
Enhanced
T1-weighted VIBE dynamic1Transversal1.554.8110°
T1-weighted FLASH FSTransversal4.76123.0070°
T1-weighted FLASH FSCoronal4.7694.0070°
T2-star-weighted FLASH 22Transversal10.0069.0090°
T2-weighted TSH FS2Transversal105.002740.00170°
Table 3 Number of lesions detected in MR-arterioportography and magnetic resonance imaging
PatientAge (yr)MR-APnumber of lesions∑102/103
Double-enhanced MRI number of lesions∑60/56
Reader 1Reader 2Reader 1Reader 2
1629954
2477822
3704522
4747843
5513333
6761211
7706698
8163--(7)(7)
9704422
10639822
11519865
1263101132
13576622
14675445
15514332
16530011
17512222
18545633
19579844
20732233