Cheng YS, Li MH, Chen WX, Chen NW, Zhuang QX, Shang KZ. Temporary partially-covered metal stent insertion in benign esophageal stricture. World J Gastroenterol 2003; 9(10): 2359-2361 [PMID: 14562413 DOI: 10.3748/wjg.v9.i10.2359]
Corresponding Author of This Article
Dr. Ying-Sheng Cheng, Department of Radiology, Sixth People’s Hospital, Shanghai Jiaotong University, Shanghai 200233, China. chengys@sh163.net
Article-Type of This Article
Brief Reports
Open-Access Policy of This Article
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Ying-Sheng Cheng, Ming-Hua Li, Qi-Xin Zhuang, Ke-Zhong Shang, Department of Radiology, Sixth People’s Hospital, Shanghai Jiaotong University, Shanghai 200233, China
Wei-Xiong Chen, Ni-Wei Chen, Department of Gastroenterology, Sixth People’s Hospital, Shanghai Jiaotong University, Shanghai 200233, China
ORCID number: $[AuthorORCIDs]
Author contributions: All authors contributed equally to the work.
Supported by the National Key Medical Research and Development Program of China during the 9th Five-year Plan Period (No.96-907-03-04), Shanghai Nature Science Funds (No.02Z1314073), Shanghai Medical Development Funds (No.00419)
Correspondence to: Dr. Ying-Sheng Cheng, Department of Radiology, Sixth People’s Hospital, Shanghai Jiaotong University, Shanghai 200233, China. chengys@sh163.net
Telephone: +86-21-64368920 Fax: +86-21-64701361
Received: May 13, 2003 Revised: May 25, 2003 Accepted: June 2, 2003 Published online: October 15, 2003
Abstract
AIM: To study the therapeutic efficacy of temporary partially-covered metal stent insertion on benign esophageal stricture.
METHODS: Temporary partially-covered metal stent was inserted in 83 patients with benign esophageal stricture. All the patients had various dysphagia scores.
RESULTS: Insertion of 85 temporary partially-covered metal stents was performed successfully in 83 patients with benign esophageal stricture and dysphagia was effectively remitted in all the 83 cases. The dysphagia score was 3.20 ± 0.63 (mean ± SD) and 0.68 ± 0.31 before and after stent insertion, and 0.86 ± 0.48 after stent removal. The mean diameter of the strictured esophageal lumen was 3.37 ± 1.23 mm and 25.77 ± 3.89 mm before and after stent insertion, and 16.15 ± 2.96 mm after stent removal. Follow-up time was from 1 week to 96 months (mean 54.26 ± 12.75 months). The complications were chest pain (n = 37) after stent insertion, and bleeding (n = 12) and reflux (n = 13) after stent removal.
CONCLUSION: Temporary partially-covered metal stent insertion is one of the best methods for treatment of benign esophageal stricture.
Key Words: $[Keywords]
Citation: Cheng YS, Li MH, Chen WX, Chen NW, Zhuang QX, Shang KZ. Temporary partially-covered metal stent insertion in benign esophageal stricture. World J Gastroenterol 2003; 9(10): 2359-2361
Benign esophageal stricture is a common complication in esophageal diseases. Balloon catheter dilation under X-ray was previously the most common treatment for benign esophageal stricture. Its short-term curative efficacy is good, but it does not last long. The development in stenting techniques has led to the increased application of stents in benign esophageal stricture. However, because of the relatively high incidence of complications and the difficulty of handling those complications, it is preferable to use stents with discretion. Here we report our experiences in using temporary partially-covered metal stent insertion in 83 patients with benign esophageal stricture.
MATERIALS AND METHODS
Materials
Eighty-three patients (48 males, 35 females, age 18-82 years) came to our clinic due to dysphagia. A dysphagia score was assessed by the quality of swallowing[1,2]. Grade 0 is for normal swallowing, grade 1 for swallowing most solid food, grade 2 for swallowing semisolids, grade 3 for swallowing liquid food only, and grade 4 for complete dysphagia. The dysphagia score of the 83 patients was 3.20 ± 0.63 (mean ± SD), and the causes of stricture were achalasia of cardia (n = 70), anastomotic stenosis (n = 5), sclerotic stricture due to ingestion of corrosive agents (n = 3) and simple sclerosis stricture after radiation therapy for esophageal carcinoma (n = 5). The diagnoses were made by an upper gastrointestinal contrast examination using barium-meal radiography and gastroscopic assessment. The mean diameter of the strictured esophageal lumen was 3.37 ± 1.23 mm in the 83 patients with partially-covered metal stent insertion.
Methods
The preparation before stent insertion involved ensuring an empty stomach for at least 4 hours, testing of the bleeding and clotting times, and intramuscular injection of ataractics before interventional procedure. The stent made from nitinol (a nonmagnetic Ni-Ti alloy) by Chinese manufacturers (Zhiye Medical Instruments Corporation, Changzhou, China, and Youyan Yijin Advanced Materials Co.Ltd, Beijing, China) has a length of 4-12 cm and a diameter of 16-30 cm. Its surface is covered with silica gel. The savary conical silica-gel dilator has a diameter of 0.5-2 cm, and contrast medium.
The patients were placed in a sitting position or lying on the side during the stent-placement operation, and false teeth were removed and dental pads were placed. A 260-cm-long exchange guidewire was inserted into the stomach. Along with the guidewire, the nitinol stent was installed in the propeller. After the propeller was pushed to the stricture segment, the mantle annular tube was retracted, after which the stent would automatically expand. After stent expansion, barium-meal radiography was routinely used to examine the stent position and the dilated stricture. Three to seven days after stent deployment, 500-1000 mL of ice-cold water was poured into the side hole of a gastroscope. A protractor was then used to loosen the stent from its surroundings and was then connected to the stent orifice. The stent orifice shrank when we contracted the protractor, and then the stent was removed along with the gastroscope. After that, a gastroscope was again inserted to examine bleeding and mucosa tearing membranes. The patients were allowed to consume cold food for the first 2 d after interventional procedure, and resumed a normal diet afterwards. Within 1 week, barium-meal examination was used to observe the intraluminal patency and swallowing function. one-month, 6-months, and 1-year follow-ups were recommended.
RESULTS
We inserted 85 temporary partially-covered metal stents in 83 patients with esophageal stricture, which were removed 3-7 d later. The placement and removal of stents were successful in 100% of cases. Immediately after placing the stent, we performed an esophageal contrast examination, which confirmed good stricture patency. The mean diameter of the esophageal lumen was 25.77 ± 3.89 mm after stent insertion, and 16.15 ± 2.96 mm after stent removal. The dysphagia score was 0.68 ± 0.31 after stent insertion, and 0.86 ± 0.48 after stent removal. The mean follow-up time was 54.26 ± 12.75 months (range 1 week-96 months). The complications immediately after stent insertion were chest pain (37 cases). After stent removal, 12 cases had a small amount of bleeding and 13 had reflux. All these complications were managed effectively. Temporary partially-covered metal stent insertion and removal were obviously effective on the esophageal stricture and dysphagia.
DISCUSSION
The short-term effect of balloon dilation on esophageal benign stricture was good, but its mid-term and long-term curative effect was not ideal. In 1990 Domschke et al[1] first reported an expandable stent used in malignant esophageal strictures. Since then different types of stent have been developed and applied to the gastrointestinal system[2]. In 1993 Cwikiel et al[3] reported the application of silica-gel-covered stent in benign esophageal strictures. The covering of the stent was found to be effective against recurrence of esophageal stricture[4-39]. Because covered stents would migrate, they have not been widely used for some time. However, patients with uncovered stents exhibited more complications such as reflux, stricture recurrence (hyperplasia of granulation tissue), and pain. There is no effective way to manage these complications, which impacts on the long-term curative effect. The worse thing for cases was that another surgical operation was sometimes required to resect the stricture section and the stent placed previously. In order to solve these problems, we used temporary partially-covered metal stent insertion in benign esophageal stricture[40]. The follow-up time was approximately 8 years. The curative effect was long-lasting, dysphagia was clearly palliated, and complications were reduced and easy to manage. Temporary partially-covered metal stent insertion was effective on benign esophageal stricture. Our follow-up investigations revealed that the mid-term and long-term curative effect of temporary stent insertion was better than that of balloon dilation and permanently uncovered or antireflux covered or partially-covered metal stent[41-48]. Our results demonstrated that it was unnecessary to perform graded diameter increment in such stents, unlike when dilating the balloon catheter. Its necessity could be decided based on the follow-up data. After stent insertion, the complications of pain and reflux due to dilating the esophageal stricture by the stent were mainly caused by the chronic tissue tearing of the layer of esophageal muscle and the damage to the original anatomy of the stomach cardia. The stent continued to expand until it reached to body temperature. Since this took 16-24 hours, the tearing of the esophageal muscle tissue was relatively regular and comparatively less scar tissue was formed. Therefore, the recurrence of stricture was low, unlike in balloon dilation which caused acute and irregular tearing on the layer of esophageal muscle, and a corresponding high recurrence of stricture. This is one reason why the method of temporary partially-covered metal stent insertion in benign esophageal stricture is better than that of balloon dilation. We used uncovered stents in patients with benign esophageal strictures in order to reduce the occurrence rate of stent migration. After stent placement, dilation was excellent and dysphagia disappeared, thus achieving the goal of treatment. However, it was accompanied by new problems such as gastroesophageal reflux and recurrence of stricture (hyperplasia of granulation tissue). The reflux could be treated with drugs, but this took a long time. Recurrence of stricture could be reduced by heat cauterization under gastroscope, but it could easily reccur. When we used antireflux covered stent, compications of gastroesophageal reflux and hyperplasia of granulation tissue were not found, but many unexpected results occurred. Comparative studies and experimental research are recommended to further explore the recurrence mechanisms. Further research and development of new stents that are biodegraded by esophageal organism within 2 months after insertion would improve their curative effect, and provide a new therapeutic method for benign esophageal stricture[49]. With further developments in molecular biology, application of gene therapy in the treatment of benign esophageal stricture is expected.
Foster DR. Self-expandable oesophageal stents in the management of benign peptic oesophageal strictures in the elderly.Br J Clin Pract. 1997;51:199.
[PubMed] [DOI][Cited in This Article: ]
Miller LS, Jackson W, McCray W, Chung CY. Benign nonpeptic esophageal strictures. Diagnosis and treatment.Gastrointest Endosc Clin N Am. 1998;8:329-355.
[PubMed] [DOI][Cited in This Article: ]
Vakil N, Gross U, Bethge N. Human tissue responses to metal stents.Gastrointest Endosc Clin N Am. 1999;9:359-365.
[PubMed] [DOI][Cited in This Article: ]
Sandha GS, Marcon NE. Expandable metal stents for benign esophageal obstruction.Gastrointest Endosc Clin N Am. 1999;9:437-446.
[PubMed] [DOI][Cited in This Article: ]
Pajarinen J, Ristkari SK, Mokka RE. A report of three cases with an oesophageal perforation treated with a coated self-expanding stent.Ann Chir Gynaecol. 1999;88:332-334.
[PubMed] [DOI][Cited in This Article: ]
Cordero JA, Moores DW. Self-expanding esophageal metallic stents in the treatment of esophageal obstruction.Am Surg. 2000;66:956-958; discussion 956-958.
[PubMed] [DOI][Cited in This Article: ]
Dormann AJ, Deppe H, Wigginghaus B. Self-expanding metallic stents for continuous dilatation of benign stenoses in gastrointestinal tract - first results of long-term follow-up in interim stent application in pyloric and colonic obstructions.Z Gastroenterol. 2001;39:957-960.
[PubMed] [DOI][Cited in This Article: ][Cited by in Crossref: 30][Cited by in F6Publishing: 37][Article Influence: 1.6][Reference Citation Analysis (0)]
Chen WX, Cheng YS, Yang RJ, Li MH, Zhuang QX, Chen NW, Xu JR, Shang KZ. Interventional therapy of achalasia with tem-porary metal internal stent dilatation and its intermediate and long term follow-up.Shijie Huaren Xiaohua Zazhi. 2000;8:896-899.
[PubMed] [DOI][Cited in This Article: ]
Wang YG, Tio TL, Soehendra N. Endoscopic dilation of esophageal stricture without fluoroscopy is safe and effective.World J Gastroenterol. 2002;8:766-768.
[PubMed] [DOI][Cited in This Article: ]
Cheng YS, Yang RJ, Li MH, Shang KZ, Chen WX, Chen NW, Chu YD, Zhuang QX. Interventional procedure for benign or malignant stricture or obstruction of upper gastrointestinal tract.Shijie Huaren Xiaohua Zazhi. 2000;8:1354-1360.
[PubMed] [DOI][Cited in This Article: ]
Chen WX, Cheng YS, Yang RJ, Li MH, Shang KZ, Zhuang QX, Chen NW. Metal stent dilation in the treatment of benign esoph-ageal stricture by interventional procedure: a follow-up study.Shijie Huaren Xiaohua Zazhi. 2002;10:333-336.
[PubMed] [DOI][Cited in This Article: ]