Minireviews Open Access
Copyright ©2013 Baishideng Publishing Group Co., Limited. All rights reserved.
World J Gastroenterol. Jun 28, 2013; 19(24): 3726-3746
Published online Jun 28, 2013. doi: 10.3748/wjg.v19.i24.3726
Small-bowel capsule endoscopy: A ten-point contemporary review
Anastasios Koulaouzidis, Centre for Liver and Digestive Disorders, the Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, Scotland, United Kingdom
Emanuele Rondonotti, Gastroenterology Unit, Ospedale Valduce, 22100 Como, Italy
Alexandros Karargyris, National Library of Medicine, National Institutes of Health, Bethesda, MD 20814, United States
Author contributions: Koulaouzidis A conceived and drafted the study, collected data and prepared the tables of this review; Rondonotti E prepared the first draft of this manuscript; Rondonotti E and Koulaouzidis A performed significant editing; Karargyris A contributed Table 10; all authors performed the final draft revisions and editing.
Correspondence to: Anastasios Koulaouzidis, MD, MRCP, FEBG, Endoscopy Unit, Centre for Liver and Digestive Disorders, the Royal Infirmary of Edinburgh, 51 Little France Crescent, Old Dalkeith Road, Edinburgh EH16 4SA, Scotland, United Kingdom. akoulaouzidis@hotmail.com
Telephone: +44-131-2421126 Fax: +44-131-2421618
Received: March 29, 2013
Revised: May 27, 2013
Accepted: June 1, 2013
Published online: June 28, 2013
Processing time: 91 Days and 23.5 Hours

Abstract

The introduction of capsule endoscopy (CE) in clinical practice increased the interest for the study of the small-bowel. Consequently, in about 10 years, an impressive quantity of literature on indications, diagnostic yield (DY), safety profile and technical evolution of CE has been published as well as several reviews. At present time, there are 5 small-bowel capsule enteroscopy (SBCE) models in the worldwide market. Head-to-head trials have showed in the great majority of studies comparable results in terms of DY, image quality and completion rate. CE meta-analyses formed the basis of national/international guidelines; these guidelines place CE in a prime position for the diagnostic work-up of patients with obscure gastrointestinal bleeding, known and/or suspected Crohn’s disease and possible small-bowel neoplasia. A 2-L polyethylene glycol-based purge, administered the day before the procedure, is the most widely practiced preparation regimen. Whether this regimen can be further improved (i.e., by further decreasing its volume, changing the timing of administration, coupling it with prokinetics and/or other factors) or if it can really affect the DY, is still under discussion. Faecal calprotectin has been used in SBCE studies in two settings: in patients taking non-steroidal anti-inflammatory drugs, to evaluate the type and extent of mucosal damage and, more importantly from a clinical point of view, in patients with known or suspected Crohn’s disease for assessment of inflammation activity. Although there is still a lot of debate around the exact reasons of SBCE poor performance in various small-bowel segments, it is worth to remember that the capsule progress is non-steerable, hence more rapid in the proximal than in lower segments of the small-bowel. Capsule aspiration, a relatively unexpected complication, has been reported with increasing frequency. This is probably related with the increase in the mean age of patients undergoing CE. CE video review is a time-consuming procedure. Therefore, several attempts have been made to develop technical software features, in order to make CE video analysis easier and shorter (without jeopardizing its accuracy). Suspected Blood Indicator, QuickView and Fujinon Intelligent Chromo Endoscopy are some of the software tools that have been checked in various clinical studies to date.

Key Words: Capsule endoscopy; Calprotectin; Meta-analysis; Review; Preparation; Reading software; Complication; Indications

Core tip: This innovative, concise and “unique” review (structured as Q and A with several tables that make this paper very easy to read and hopefully enjoyable), keeps narrative text to the necessary minimum, in order to guide the reader to consult the wealth of information included in tabulated form. These tables are the outcome of the authors’ personal endeavor to compile in a detailed, yet easy to refer way, information that has often been overlooked by the plethora of similar reviews and/or info on contentious issues in capsule enteroscopy. We believe that this document can be used as reference for study, in reference lists of future manuscript and as important guide for future clinical research on the field.



INTRODUCTION

An early conceptual abstract on capsule endoscopy (CE), entitled “an endorobot for flexible endoscopy, a feasibility study”, was published in 1994[1]. Then, in 1997 two groups of pioneers, initially working independently in Israel and London, joined forces to achieve wireless endoscope[2]. Three years later, in the Digestive Disease Week meeting of the millennium and almost concurrently in Nature[3], Professor Swain presented the world’s first wireless capsule endoscope.

Indeed, the brainchild of Iddan[4] has revolutionised the field of gastrointestinal (GI) diagnostics, turning into reality the concept of painless and wireless endoscopy. Furthermore, the introduction of CE in clinical practice increased the interest for the study of the small-bowel. Consequently, in about 10 years, an impressive quantity of literature on indications, diagnostic yield (DY), safety profile and technical evolution of CE has been published as well as several reviews. Therefore, we aim to focus readers’ attention on contemporary and contentious issues, often missed from similar reviews on the field. We herein present (in a comprehensive yet user-friendly manner) a systematic review of the current literature in a form of question-and-answer. We expect CE readers, of all experience levels, will find this review useful source of further reading and reference.

WHICH ARE THE DIFFERENCES AMONG THE CURRENT COMMERCIALLY AVAILABLE CAPSULES?

Since 2001, the year of approval by the Food and Drug Administration of the first video capsule with the prophetic, yet slightly unfortunate, brand name mouth-to-anus (M2A®; Given®Imaging, Yoqneam, Israel), a total of more than 2000000 capsules have been ingested worldwide[5]. Furthermore, over the last decade, technology has improved in the field of CE as competition has become quite stiff. At present time, there are 5 small-bowel capsule enteroscopy (SBCE) models in the market worldwide (Table 1)[5,6]. Although similar in size and shape, they differ on several technical aspects. Of the 5 SBCE, four are in widespread use, although most of the published literature studies are with PillCam®. Nevertheless, head-to-head trials have showed in the great majority of studies comparable results in terms of DY, image quality and completion rate (Table 2)[7-11].

Table 1 Available types of small-bowel capsule endoscopes and operating characteristics.
Capsule deviceCompanyCountryField of view (°)LensLEDsImage sensorTransmissionFrames per second (fps)Dimensions (mm)Weight (g)Battery life (h)Real-time imagerFDA approvalReviewing softwareOptical enhancements
PillCam®SB2Given®Imaging, YokneamIsrael156Multi-element4CMOSRadiofrequency2-4111 × 263.459->11.52YesYesRapid®v7Blue-mode FICE 1,2,3
MiroCam®v2IntroMedic® Co., SeoulSouth Korea170N/A4CMOSEFP3ø11 × 243.212YesYesMiroView®v2ALICE colour-mode
EndoCapsule®Olympus© Co., TokyoJapan145N/A4CCDRadiofrequency2ø11 × 263.4510YesYesOLYMPUS®WS-1Contrast imaging
OMOM® (SmartCapsule)Chongding Jinshan Science and Technology Co., BeijingChina140N/A4CCDRadiofrequency2 (variable)13 × 27.968YesNoOMOM® workstationN/A
CapsoCam®SV1CapsoVision® Inc., SaratogaUnited States360N/A16N/AOn-board EPROM flash memory (USB)16 (4 per camera)11 × 31N/A15NoNoCapsoView®N/A
Table 2 Head-to-head trials of small-bowel capsule endoscopy systems.
Ref.CountryCentreObjective(s)Study typeDesignCE typeOutcome(s)Conclusion
Hart-mann et al[7]GermanySingle centreHead-to-head evaluation of technical performance and DY of two CE systems (PillCam®SB vs EndoCapsule®)Prospective►OGIB pts;►PillCam®SB (Given®Imaging, Yoqneam, Israel);►Pts enrolled: 40;►Statistically non-significant trend for EndoCapsule® to detect more bleeding sources in pts with suspected small-bowel bleeding than PillCam®SB;
►Pts randomized to undergo 2 CEs using different CE in random order►CR: PillCam®SB 33/40 (82%); EndoCapsule® 40/40 (100%); P = NS;
►Overall DY: PillCam®SB 26/50 (52%); EndoCapsule® 29/50 (58%); P = NS;
►Pts randomized to undergo 2 CEs using different CE in random order►DY (SB P2): PillCam®SB 22/50 (44%), EndoCapsule® 25/50 (50%), P = NS;
►In all discordant SB P2findings (not detected by the PillCam®SB but detected by EndoCapsule®), PillCam®SB examinations were incomplete►This is (likely) due to the longer recording time with EndoCapsule®
Cave et al[8]United StatesMulti-centre (4 centres)Comparison of performance (DY in pts with OGIB): EndoCapsule®vs PillCam®SBProspective►OGIB pts;►EndoCapsule® (Olympus© America, Allentown, PA);►Pts with OGIB (transfused or with haematocrit < 31%) (males) or < 28% (females): 63;►Both devices are safe and have comparable DY within the previously reported range;
►EndoCapsule® and PillCam®SB swallowed by each participant 40 min apart;►Available data 51/63; 9 pts excluded for technical reasons + 3 pts for protocol violation;
►24 videos read as normal, 14 as abnormal (from both CEs). Disagreement occurred in 13;►Subjective difference in image quality favouring the EndoCapsule®;
►Ingestion of CEs in randomized order;►PillCam®SB (Given®Imaging, Yoqneam, Israel)►No adverse events reported for either CE. Overall agreement: 38/51 (74.5%), κ = 0.48, P = 0.008;
►Head-to-head comparison of CEsLimitations: Although ingestion randomized, videos reading not blind (different shape of the image margin)►Lack of electromechanical interference between 2 different CE
Kim et al[9]South KoreaSingle centreHead-to-head evaluation of technical performance DY and of two capsule systems (PillCam®SB vs MiroCam®)Prospective►Pts referred to CE for various indications;►MiroCam® (IntroMedic Co. Ltd., Seoul, South Korea);►Pts enrolled: 24;►MiroCam shows a longer operating time and a higher CR;
►Each pt was randomly assigned to swallow 1 of 2 CEs, the second CE was swallowed once fluoroscopy indicated that first CE had reached the SB►Mean operating time: MiroCam® 702 min; PillCam®SB 446 min, P < 0.001;
►CR: MiroCam® 20/24 (83%); PillCam®SB 14/24 (59%), P = 0.031;►Nevertheless, the 2 capsule systems showed comparable efficiency;
►PillCam®SB (Given®Imaging, Yoqneam, Israel)►DY: MiroCam® 11/24 (45.8%); PillCam®SB 10/24 (41.7%), P = 1.0;
►DY (additive of both capsules): 12/24 (50%);►Sequential capsule endoscopy with the MiroCam and PillCam SB produced slight (but NS) increase in DY
►Concordance of findings among the two capsule systems 87.5%, κ = 0.74
Pioche et al[10]FranceMulti-centreHead-to-head evaluation of the diagnostic concordance (κ value): PillCam®SB SB2 vs MiroCam®Prospective►OGIB pts;►MiroCam®; (IntroMedic Co. Ltd., Seoul, South Korea);►83 pts; drop-outs explained (10 technical issues), 73 pts/videos analysed;►MiroCam® showed a slightly higher DY, difference not statistically significant;
►Each pt ingested 2 CEs at a 1 h interval in a random order;►31 concordant (-) ve cases (42.4%) and 30 concordant (+) ve cases (41.1%);
►Satisfactory diagnostic concordance between the 2 systems (κ = 0.66);►The 2 CE systems showed comparable efficiency for the diagnosis of OGIB
►Videos read in a random order by 2 experienced (> 200 CEs) readers;►PillCamSB2 (Given®Imaging, Yoqneam, Israel)►DY similar among the 2 CE systems(PillCam®SB 2 vs MiroCam®: 46.6% vs 56.2%, respectively; P = 0.02);
►Image-by-image review of cases of disagreement between the readers was performed by 3 expert readers►SBTT longer with MiroCam®vs PillCam®SB (mean SBTT: 268 vs 234 min, < 0.05);
►Reading time longer with MiroCam®vs PillCam®SB (mean reading time 40 vs 23 min, P < 0.05);
►(+) ve diagnosis obtained in 46.6% vs 56.2% of pts with PillCam®SB2 vs MiroCam®, respectively;
►PillCam®SB2 vs MiroCam®CEs identified 78.6% vs 95.2% of (+) ve cases, respectively, P = 0.02
Dolak et al[11]AustriaSingle centreHead-to-head comparison (MiroCam®vs EndoCapsule®) of: CR of SB examinations, DY in SB diseaseProspective►Pts referred to CE for various indications;►MiroCam® (IntroMedic Co. Ltd., Seoul, South Korea);►Pts enrolled: 50;►The two capsule endoscopy systems were not statistically different with regards to CR and DY;
►Each pt was randomly assigned to swallow either MiroCam® first, followed by the EndoCapsule® 2 h later, or vice versa;►CR: MiroCam® 48/50 (96%) vs EndoCapsule® 45/50 (90%); P = 0.38;
►DY in SB: MiroCam® 25/50 (50%) vs EndoCapsule® 24/50 (48%); P > 0.99;
►EndoCapsule® (Olympus America, Allentown, PA)►Concordance of findings among the two CE systems: 68%; κ = 0.50►Moderate concordance, mainly caused by missed pathological findings (which affected both devices), needs consideration in clinical practice
►All videos analysed by two investigators independently
DO HIGH-GRADE EVIDENCE SUPPORT THE USE OF CE IN CLINICAL PRACTICE?

In recent years, many authors[12-14] reviewed systematically the validity of SBCE in clinical practice. Out of this evidence base, it clearly emerges that in daily practice the leading indications for CE are: Obscure gastrointestinal bleeding (OGIB accounts for 60%-70% of all SBCE examinations world-wide), and Crohn’s disease (CD; known and/or suspected). Other clinical indications, although less common, are coeliac disease, small-bowel polyposis syndromes and clinical suspicion of small-bowel neoplasia[15,16]. Therefore, we decided to summarize (Table 3)[17-32], the results of the more robust - from a methodological point of view - publications which addressed the role of CE in the field of small-bowel coeliac disease. These meta-analyses have formed the basis of national/international guidelines, which place CE in a prime position for the diagnostic work-up of patients with OGIB, known and/or suspected CD and possible small-bowel neoplasia[33-36].

Table 3 Available meta-analyses and systematic reviews in the field of small-bowel capsule endoscopy.
Ref.TitleSearch (start - end date)TypeSubjectData extractorsTotal titles foundTitles entered meta-analysisIndividuals includedOutcome/conclusion
Liao et al[13]Indications, detection, completion, and retention rates of SBCE: A systematic review2000 - Jan 2009Systematic review of evidence baseIndications, DR, CR and RR of SBCE222722722753 Pts; 22840 CE►Most common indications: OGIB (66.0%); investigation of clinical symptoms (10.6%); definite/suspected CD (10.4%);
►Pooled DRs for overall, OGIB, CD, neoplasia: 59.4%, 60.5%, 55.3%, 55.9%, respectively;
►Commonest cause for OGIB: angiodysplasia (50.0%);
►Pooled CRs (overall): 83.5%; breakdown 83.6% (OGIB), 85.4% (clinical symptoms), 84.2% (CD);
►Pooled RRs (overall): 1.4%; breakdown 1.2% (OGIB), 2.6% (clinical symptoms), 2.1% (CD);
►Hence, most common indication for SBCE is OGIB, with high DR and low RR;
►A relatively high RR is associated with definite/suspected CD and neoplasms
Marmo et al[17]Meta-analysis: Capsule enteroscopy vs conventional modalities in diagnosis of SB diseasesJan 1966 - Mar 2005Meta-analysis of diagnostic test accuracyDY/safety of SBCE vs alternative modalities (PE, SBBaR or enteroclysis) in SB disease218717526 pts (289 OGIB and 237 CD)►17 studies (526 patients) met inclusion criteria;
►Overall, the rate difference for SB disease (i.e., the absolute pooled difference in the rate of positive findings) of SBCE vs alternative modalities was 41% (95%CI: 35.6-45.9);
►For OGIB, 37% (95%CI: 29.6-44.1) for Crohn's disease 45% (95%CI: 30.9-58.0);
►Incomplete SBCE occurred in 13%, more often in OGIB (17%) than in pts with CD (8%) (P < 0.006);
►Adverse events: 29 pts (6%);
►Capsule retention more frequent in pts with CD (3% vs 1%, OR 4.37)
Triester et al[18]A meta-analysis of the yield of CE compared to other diagnostic modalities in patients with OGIBN/A - April 2005Meta-analysis of diagnostic test accuracyIY (yield of CE-yield of comparative modality) and 95%CI of CE over comparative modalities28014396 CE-PE; 88 CE-SBBaR►14 studies (n = 396) compared DY CE vs PE in OGIB, 63% vs 28%, respectively (IY = 35%, P < 0.00001, 95%CI: 26%-43%);
►For clinically significant findings (n = 376) DY was 56% (CE) vs 26% (PE), IY = 30%, P < 0.00001, 95%CI: 21%-38%;
►3 studies (n = 88) compared DY of CE vs SBBaR, 67% vs 8%, respectively (IY = 59%, P < 0.00001, 95%CI: 48%-70%);
►For clinically significant findings DY was 42% (CE) vs 6% (SBBaR); IY = 36%, P < 0.00001, 95%CI: 25%-48%;
►NNT to yield one additional clinically significant finding with CE over either modality: 3 (95%CI: 2-4);
►1 study compared DY (significant findings) of CE vs intraoperative enteroscopy (n = 42, IY = 0%, P = 1.0, 95%CI: -16%-16%);
►1 study compared DY (significant findings) of CE vs CT enteroclysis (n = 8, IY = 38%, P = 0.08, 95%CI: -4%-79%);
►1 study compared DY (significant findings) of CE vs mesenteric angiogram (n = 17, IY = -6%, P = 0.73, 95%CI: -39%-28%);
►1 study compared DY (significant findings) of CE vs SB MRI (n = 14, IY = 36%, P = 0.007, 95%CI: 10%-62%);
►CE-DY vs PE (vascular lesions): 36% vs 20% (IY = 16%, P < 0.00001, 95%CI: 9%-23%);
►CE-DY vs PE (inflammatory lesions): 11% vs 2% (IY = 9%, P = 0.0001, 95%CI: 5%-13%);
►CE-DY vs PE (tumours or "other" findings): no difference
Leighton et al[19]Capsule endoscopy: A meta-analysis for use with OGIB and CDN/A - April 2005Meta-analysis of diagnostic test accuracyDY and safety of SBCE vs alternative modalities (PE, SBBaR or enteroclysis) in SB disease28020537 pts►CE superior to PE/SB radiography for diagnosing SB pathology in pts with OGIB (yield comparable to intraoperative endoscopy);
►Incremental yield of CE over PE/SB radiography is > 30% for clinically significant findings, due to visualization of additional vascular, inflammatory lesions by CE;
►CE was also superior to SB radiography, C + IL, CT enterography, PE for diagnosing non-stricturing SBCD;
►Marked improvement in yield with the use of CE over all other methods in pts who had established CD and were evaluated for SB recurrence;
►Unknown whether these results will translate into improved pt outcomes with the use of CE vs alternate methods
Leighton et al[19]Capsule endoscopy: A meta-analysis for use with OGIB and CDN/A - April 2005Meta-analysis of diagnostic test accuracyDY and safety of SBCE vs alternative modalities (PE, SBBaR or enteroclysis) in SB disease28020537 pts►CE superior to PE/SB radiography for diagnosing SB pathology in pts with OGIB (yield comparable to intraoperative endoscopy);
►Incremental yield of CE over PE/SB radiography is > 30% for clinically significant findings, due to visualization of additional vascular, inflammatory lesions by CE;
►CE was also superior to SB radiography, C + IL, CT enterography, PE for diagnosing non-stricturing SBCD;
►Marked improvement in yield with the use of CE over all other methods in pts who had established CD and were evaluated for SB recurrence;
►Unknown whether these results will translate into improved pt outcomes with the use of CE vs alternate methods
Triester et al[20]A meta-analysis of the yield of CE compared to other diagnostic modalities in patients with non-stricturing SB Crohn’s diseaseN/A - Aug 2005Meta-analysis of diagnostic test accuracy2829250 pts►9 studies (n = 250) compared DY CE vs SBBaR in CD: 63% vs 23%, respectively (IY = 40%, P < 0.001, 95%CI: 28%-51%);
►4 studies (n = 114) compared DY CE vs C + IL in CD: 61% vs 46%, respectively (IY = 15%, P = 0.02, 95%CI: 2%-27%);
►3 studies (n = 93) compared DY CE vs CT enterography/enteroclysis: 69% vs 30%, respectively (IY = 38%, P = 0.001, 95%CI: 15%-60%);
►2 studies compared DY CE vs PE: (IY = 38%, P < 0.001, 95%CI: 26%-50%);
►1 study compared DY CE vs SBMRI (IY = 22%, P = 0.16, 95%CI: -9%-53%);
Sub-analysis (pts with suspected CD): no difference in DY CE vs SBBaR (P = 0.09), C + IL (P = 0.48), CT enterography (P = 0.07) or PE (P = 0.51);
Sub-analysis (pts with established CD): difference in DY CE vs SBBaR (P < 0.001 C + IL (P = 0.002), CT enterography (P < 0.001) and PE (P < 0.001)
Pasha et al[21]DBE and CE have comparable DY in SB disease: A meta-analysisN/A - Dec 2006Meta-analysis of diagnostic test accuracyComparison of DY of CE vs DBE211311397 pts►Pooled DY CE vs DBE: 60% vs 57% (IYW = 3%, 95%CI: -4%-10%, P = 0.42, FEM);
►Pooled DY CE vs DBE (vascular findings, 10 studies): 24% vs 24% (IYW = 0%, 95%CI: -5%-6%, P = 0.88, REM);
►Pooled DY CE vs DBE (inflammatory findings, 9 studies): 18% vs 16% (IYW = 0%, 95%CI: -5%-6%, P = 0.89, FEM);
►Pooled DY CE vs DBE (polyps/tumours, 9 studies): 11% vs 11% (IYW = -1%, 95%CI: -5%-4%, P = 0.76, FEM);
►SB disease: CE vs DBE have comparable DY, including OGIB, CE should be the initial diagnostic test for determining the insertion route of DBE
Niv[22]Efficiency of bowel preparation for capsule endoscopy examination: A meta-analysisN/A - July 2007Meta-analysis of RCTs and cohort studiesPurgative use vs fasting alone for SBCE168130 bowel prep; 107 fasting►237 pts, 130 with and 107 without preparation;
►Seven out of 8 studies included a comparison of GTT, SBTT and CR;
►SBCE CR: 76% in pts with preparation vs 68% without prep (difference did not reach statistical significance);
►No statistically significant difference between CEs performed with or without preparation in GTT (pooled effect size, -0.054; 95%CI: -0.418-0.308) or SBTT (pooled effect size, -0.327; 95%CI: -1.419 - -0.765)
El-Matary et al[23]Diagnostic characteristics of given video capsule endoscopy in diagnosis of celiac disease: A meta-analysisMeta-analysis of diagnostic test accuracyCoeliac and CE2N/A3107 pts►3 studies (n = 107, 63 pts with CD/44 without) met inclusion criteria;
►Pooled SBCE (overall) Sens and Spec: 83% (95%CI: 71%-90%) and 98% (95%CI: 88%-99.6%), respectively;
►No major complications reported;
►Costs mentioned only in 1 study. Overall, diagnostic characteristics of SBCE, could not justify the routine use of SBCE as alternative to biopsy
Chen et al[24]A meta-analysis of the yield of CE compared to DBE in pts with SB diseasesN/A - Feb 2007Meta-analysis of diagnostic test accuracyComparison of DY of CE vs DBE21638277 pts►8 studies (n = 277 pts) prospectively compared the yield of CE and DBE were included;
►No difference between the yield of CE and DBE (170/277 vs 156/277, OR 1.21, 95%CI: 0.64-2.29);
►Sub analysis: yield of CE significantly higher than that of DBE without combination of oral+anal insertion approaches (137/219 vs 110/219, OR 1.67, 95%CI: 1.14-2.44, P < 0.01), but not superior to the yield of DBE with combination of the two insertion approaches (26/48 vs 37/48, OR 0.33, 95%CI: 0.05-2.21, P < 0.05);
►Focused meta-analysis of the fully published articles concerning OGIB showed similar results wherein the yield of CE was significantly higher than that of DBE without combination of oral + anal insertion approaches (118/191 vs 96/191, fixed model: OR 1.61, 95%CI: 1.07-2.43, P < 0.05) and the yield of CE was significantly lower than that of DBE by oral+ anal combinatory approaches (11/24 vs 21/24, fixed model: OR 0.12, 95%CI: 0.03-0.52, P < 0.01)
Rokkas et al[25]Does purgative preparation influence the diagnostic yield of small bowel video capsule endoscopy? A meta-analysisN/A - Feb 2008Meta-analysis of RCTs and cohort studiesPurgative use vs fasting alone for SBCE219412718 pts purgative; 444 controls►12 eligible studies (6 prospective/6 retrospective), including 16 sets of data;
►Significant difference in DY between pts prepared with purgatives (n = 263) vs pts prepared with clear liquids (n = 213): OR = 1.813 (95%CI: 1.251-2.628, P = 0.002);
►Significant difference in SBVQ between pts prepared with purgatives (n = 404) vs pts prepared with clear liquids (n = 249): OR = 2.113 (95%CI: 1.252-3.566, P = 0.005); There was no statistically significant difference regarding CR rate. Purgatives did not affect VCE GTT or VCE SBTT
Dionisio et al[26]CE has a significantly higher DY in patients with suspected and established small-bowel CD: A meta-analysis2000 - May 2009Meta-analysis of diagnostic test accuracyDY of CE vs modalities in patients with suspected/ established CD229112428 pts►8 studies (n = 236 pts) compared CE vs C + IL, 4 (n = 119 pts) CE vs CTE, 2 (n = 102 pts) vs PE, 4 (n = 123 pts) vs MRE;
►For suspected CD, several comparisons met statistical significance; Yields in this subgroup were: CE vs SBR: 52% vs 16% (IYw = 32%, P < 0.0001, 95%CI: 16%-48%), CE vs CTE: 68% vs 21% (IYw = 47%, P < 0.00001, 95%CI: 31%-63%), CE vs C + IL: 47% vs 25% (IYw = 22%, P = 0.009, 95%CI: 5%-39%);
►For established CD, statistically significant yields for CE vs an alternate diagnostic modality in patients were seen: CE vs PE: 66 vs 9% (IYw = 57%, P < 0.00001, 95%CI: 43-71%), CE vs SBR: 71 vs 36% (IYw = 38%, P < 0.00001, 95%CI: 22%-54%), CE vs CTE: 71 vs 39% (IYw = 32%, P ≤ 0.0001, 95%CI: 16%-47%)
Wu et al[27]Systematic review and meta-analysis of RCTs of Simethicone for GI endoscopic visibilityN/A- Nov 2009Meta-analysis of RCTsSimethicone and CE21284121 pts►Adequate or excellent/good SB mucosa visualization in pts receiving Simethicone vs those who did not (66.1% vs 37.2%);
►Pooled OR = 2.84 (95%CI: 1.74-4.65, P = 0.00); no significant heterogeneity (P = 0.16, I2 = 38.8%) or publication bias (P = 0.251);
►Sens analysis: studies stratified by factors such as bowel preparation (purgative vs fasting): Significant results for bowel preparation + fasting (OR = 4.43, 95%CI: 1.82-10.76, P = 0.00) with P = 0.78, I2 = 0.0%, No significant results for bowel preparation + purgative (OR = 1.59, 95%CI: 0.78-3.27, P = 0.203) with P = 0.20, I2 = 38.9%
Rokkas et al[25]Does purgative preparation influence the diagnostic yield of small bowel video capsule endoscopy? A meta-analysisN/A - Feb 2008Meta-analysis of RCTs and cohort studiesPurgative use vs fasting alone for SBCE219412718 pts purgative; 444 controls►12 eligible studies (6 prospective/6 retrospective), including 16 sets of data;
►Significant difference in DY between pts prepared with purgatives (n = 263) vs pts prepared with clear liquids (n = 213): OR = 1.813 (95%CI: 1.251-2.628, P = 0.002);
►Significant difference in SBVQ between pts prepared with purgatives (n = 404) vs pts prepared with clear liquids (n = 249): OR = 2.113 (95%CI: 1.252-3.566, P = 0.005); There was no statistically significant difference regarding CR rate. Purgatives did not affect VCE GTT or VCE SBTT
Dionisio et al[26]CE has a significantly higher DY in patients with suspected and established small-bowel CD: A meta-analysis2000 - May 2009Meta-analysis of diagnostic test accuracyDY of CE vs modalities in patients with suspected/ established CD229112428 pts►8 studies (n = 236 pts) compared CE vs C + IL, 4 (n = 119 pts) CE vs CTE, 2 (n = 102 pts) vs PE, 4 (n = 123 pts) vs MRE;
►For suspected CD, several comparisons met statistical significance; Yields in this subgroup were: CE vs SBR: 52% vs 16% (IYw = 32%, P < 0.0001, 95%CI: 16%-48%), CE vs CTE: 68% vs 21% (IYw = 47%, P < 0.00001, 95%CI: 31%-63%), CE vs C + IL: 47% vs 25% (IYw = 22%, P = 0.009, 95%CI: 5%-39%);
►For established CD, statistically significant yields for CE vs an alternate diagnostic modality in patients were seen: CE vs PE: 66 vs 9% (IYw = 57%, P < 0.00001, 95%CI: 43-71%), CE vs SBR: 71 vs 36% (IYw = 38%, P < 0.00001, 95%CI: 22%-54%), CE vs CTE: 71 vs 39% (IYw = 32%, P ≤ 0.0001, 95%CI: 16%-47%)
Wu et al[27]Systematic review and meta-analysis of RCTs of Simethicone for GI endoscopic visibilityN/A - Nov 2009Meta-analysis of RCTsSimethicone and CE21284121 pts►Adequate or excellent/good SB mucosa visualization in pts receiving Simethicone vs those who did not (66.1% vs 37.2%);
►Pooled OR = 2.84 (95%CI: 1.74-4.65, P = 0.00); no significant heterogeneity (P = 0.16, I2 = 38.8%) or publication bias (P = 0.251);
►Sens analysis: studies stratified by factors such as bowel preparation (purgative vs fasting): Significant results for bowel preparation + fasting (OR = 4.43, 95%CI: 1.82-10.76, P = 0.00) with P = 0.78, I2 = 0.0%, No significant results for bowel preparation + purgative (OR = 1.59, 95%CI: 0.78-3.27, P = 0.203) with P = 0.20, I2 = 38.9%
Cohen et al[28]Use of CE in diagnosis and management of pediatric patients, based on meta-analysisJan 2001 - May 2010Systematic review of evidence baseSystematic compilation of data on indications and outcomes of CE in paediatric patients2N/A15740 examinations; 723 pts►Most common indication for CE (in pts < 18 yr): suspicion or evaluation of IBD (overall 54%), Breakdown: suspected CD (34%), known CD (16%), UC (1%), indeterminate colitis (3%)
►CR and RR: 86.2% (95%CI: 81.5-90.3%) and 2.6% (95%CI: 1.5-4.0%), respectively;
►CE RR (gastric and SB): 0.5% and 1.9%, respectively, similar to those of adults, by indication;
►CE with positive findings: 65.4% (95%CI: 54.8%-75.2%);
►CE resulting in new diagnosis: 69.4% (95%CI: 46.9%-87.9%); CE leading to change in therapy: 68.3% (95%CI: 43.6%-88.5%)
Teshima et al[29]DBE and CE for OGIB: An updated meta-analysisN/A - June 2010Meta-analysis of diagnostic test accuracyOGIB; CE or DBE214710651 CE; 642 DBE►Pooled DY for CE: 62% (95%CI: 47.3%-76.1%)
►Pooled DY for DBE 56% (95%CI: 48.9%-62.1%); OR for CE vs DBE of 1.39 (95%CI: 0.88-2.20; P = 0.16);
Subgroup analyses
►DBE-DY after (+)ve CE: 75.0% (95%CI: 60.1%-90.0%)
►DBE-DY after (-)ve CE: 27.5% (95%CI: 16.7%-37.8%)
►DBE-OR (for successful diagnosis after (+)ve CE) compared with DBE: 1.79 (95%CI: 1.09-2.96, P = 0.02)
►In OGIB CE and DBE have similar DY, DBE-DY significantly higher when performed in pts with prior positive CE
Belsey et al[30]Meta-analysis: efficacy of SB preparation for SBCEJan 2000 - Dec 2010Meta-analysis of RCTsPurgative use vs fasting alone for SBCE2338291 PEG; 133 NaP; 322 fasting►8 studies, using PEG or NaP-based bowel cleansing regimens;
►Any form of purgative significantly better visibility than fasting alone (OR = 2.31; 95%CI: 1.46-3.63, P < 0.0001);
►Similar results on DY (OR = 1.88; 95%CI: 1.24-2.84; P = 0.023);
Subgroup analyses (per cleansing regimen used):
►PEG-based regimens showed benefit (OR = 3.11; 95%CI: 1.96-4.94, P < 0.0001);
►NaP-based regimens no significant difference from fasting alone (OR = 1.32; 95%CI: 0.59-2.96, P < 0.0001);
►Use of purgatives (alongside fasting) is recommended in SBCE; PEG-based regimens offer a clear advantage over NaP;
►Lower volume PEG regimens as efficacious as higher volumes traditionally used for colonoscopy preparation
Rokkas et al[31]The role of video CE in the diagnosis of coeliac disease: A meta-analysisN/A - April 2011Meta-analysis of diagnostic test accuracyCoeliac and CE24616166 pts►Pooled CE Sens: 89% (95%CI: 82%-94%) and Spec: 95% (95%CI: 89%-98%), AuROC: 0.9584;
►Although not as accurate as pathology, CE a reasonable alternative method of diagnosing coeliac disease
Koulaouzidis et al[32]Diagnostic yield of SBCE in patients with IDA: A systematic reviewJan 2001 - Nov 2011Systematic review of evidence baseIDA and CE21225241960 pts►Pooled SBCE-DY in IDA: 47% (95%CI: 42%-52%), with significant heterogeneity among included studies (I2 = 78.8%, P < 0.0001);
WHICH IS THE BEST PREPARATION REGIMEN FOR SMALL-BOWEL CAPSULE ENDOSCOPY?

This certainly is one of the most contentious issues in CE. Since the introduction of CE in clinical practice, it was clear that small-bowel cleanliness is one of the key factors (as in fact is often the case for endoscopic examinations) to guarantee high diagnostic performance. Thus far, several studies have been performed in order to test whether the administration of different purgatives and/or prokinetics would impact on small-bowel cleanliness. It is noteworthy that these studies are rather heterogeneous in terms of type of laxatives administered, dosages and/or administration schedule (Table 3)[22,25,30]. Furthermore, in some studies laxatives and prokinetics were administered concurrently, which is probably a further source of bias. Essentially, the current evidence base suggests that a preparation regimen based on laxatives [more specifically polyethylene glycol (PEG)] is more effective -than fasting alone- in improving the small-bowel mucosa visualization. Among the PEG-based laxatives, a low volume schedule seems to be at least equally effective than high volume regimens[25,30]. Therefore, a 2-L PEG-based purge, administered the day before the procedure, is the most widely practiced preparation regimen. Whether this regimen can be further improved (i.e., by further decreasing its volume, changing the timing of administration, coupling it with prokinetics and/or other pharmaceutical factors) or if it can really affect the DY, is still under discussion[37].

IS THERE A ROLE FOR FAECAL TESTING (CALPROTECTIN) AS "SELECTION TOOL" FOR CAPSULE ENDOSCOPY

Due to its high DY and its negative predictive value (NPV), CE has shown considerable cost-effectiveness[38]. However, CE still remains less widely available and likely more expensive, when compared to other diagnostic modalities for the small-bowel[39]. Furthermore, although CE is generally considered overall a safe modality, it can lead to severe complications (capsule retention in some patients’ subgroups is reported as high as 15%[13-15,40]. Consequently, any tool or methods that allows selection of candidates, hence a more targeted and/or smooth “delivery” of SBCE, is a welcome approach. However, any pre-CE selection tool should be easy to perform, safe, inexpensive and fast[41]. In light of all these issues, faecal inflammation tests [of which, faecal calprotectin (FC) is the more widely available] have been proposed. In fact, FC has been used in SBCE studies in two settings: in patients taking non-steroidal anti-inflammatory drugs, to evaluate the type and extent of mucosal damage (Table 4)[41-44] and, more importantly from a clinical point of view, in patients with known or suspected CD for assessment of inflammation activity (Table 4)[45-48]. In these patients, although there is no clear agreement on a cut-off level, FC seems to be a cost-effective “screening test”, able to identify those with higher possibility to present small-bowel lesions.

Table 4 Studies evaluating the clinical application of faecal calprotectin in the setting of small-bowel capsule endoscopy.
Ref.CountryCentreStudy typeDesignParticipantsFCCEObjective(s)Outcome(s)
Goldstein et al[41]United StatesMulti-centreProspectiveDouble-blind, triple-dummy, placebo controlled334 healthy subjectsN/AM2A®; Given®Imaging, Yokneam, IsraelEvaluate incidence of SB injury and correlation with FC in healthy subjects on celecoxib or ibuprofen + omeprazole►Mean increase in FC higher in subjects on ibuprofen+omeprazole compared with celecoxib alone (P < 0.001);
►No correlation between FC and SB mucosal breaks
Hawkey et al[42]Germany, United KingdomMulti-centreProspectiveDouble-blind, double-dummy, placebo controlled139 healthy subjectsPhical Calprotectin Test Kit NovaTec Immunodiagnostica, GmbH Dietzenbac, GermanyM2A®; Given®Imaging, Yokneam, IsraelInvestigate SB injury lumiracoxib reduces vs naproxen + omeprazole►More SB mucosal breaks on naproxen+omeprazole (77.8% vs 40.4%, P < 0.001);
►Furthermore, higher FC vs placebo (96.8 vs 14.5 μg/g, P < 0.001);
►27.7% on lumiracoxib had SB mucosal breaks (vs placebo, P = 0.196; vs naproxen, P < 0.001)
►No increase in FC (-5.7 μg/g; vs placebo, P = 0.377; vs naproxen, P < 0.001)
Smecuol et al[43]Argentina, Spain, CanadaMulti-centreProspectiveNon-blinded study20 healthy subjectsCalprest® Eurospital SpA, Trieste, ItalyM2A®; Given®Imaging, Yokneam, IsraelDetermine SB damage by low-dose ASA (on a short-term basis)►Short-term administration of low-dose ASA associated with mucosal abnormalities of the SB mucosa;
►Median baseline FC (6.05 μg/g; range: 1.9-79.2 μg/g) increased significantly after ASA use
Werlin et al[44]United States, Israel, United KingdomMulti-centreProspectiveN/A42 pts with CF* (aged 10-36 yr); 29 had pancreatic insufficiencyCalprest® Eurospital SpA, Trieste, ItalyPillCam®SB; Given®Imaging, Yokneam, IsraelExamine the SB of pts with CF without overt evidence of GI disease using CE►Varying degrees of diffuse areas of inflammatory findings in the SB: oedema, erythema, mucosal breaks and frank ulcerations;
►No adverse events recorded;
FC markedly high in pts with pancreatic insufficiency, 258 μg/g (normal < 50)
Koulaouzidis et al[45]United KingdomSingle centreRetrospectiveChart review70 pts with suspected CD and (-) ve bi-directional endoscopyCALPRO NovaTec Immunodiagnostica GmbH, Dietzenbac, Germany(1) PillCam®SB; Given®Imaging, Yokneam, Israel; (2) MiroCam®; IntroMedic Co., Seoul, South KoreaValue of FC as selection tool for further investigation of the SB with SBCE, in a cohort of pts with suspected CD►FC = 50-100 μg/g: normal SBCE, despite symptoms suggestive of IBD;
►FC > 100 μg/g: good predictor of positive SBCE;
►FC > 200 μg/g: associated with higher SBCE DY (65%); confirmed CD in 50%;
►Measurement of FC prior SBCE: useful tool to select patients for referral. If FC < 100 μg/g: SBCE is not indicated (NPV 1.0)
Jensen et al[46]DenmarkSingle centreProspectiveBlinded study83 pts from GI OPD clinics with suspected CDCalprotectin ELISA, BÜHLMANN Laboratories AG, Basel, SwitzerlandPillCam®SB; Given®Imaging, Yokneam, IsraelDetermine FC levels in CD restricted to SB compared to colonic CD, in pts on first diagnostic work-up; Assess the Sens and Spec of FC in suspected CD►In pts with SB or colonic CD FC is equal: median 890 μg/g vs 830 mg/kg, respectively (P = 1.0);
►FC cut-off = 50 μg/g: 92% and 94% Sens for SB and colonic CD, respectively;
►Overall, Sens and Spec for FC: 95% and 56%;
►CD was ruled out with NPV of 92%;
►In suspected CD, FC is effective marker to r/o CD and select patients for endoscopy
Koulaouzidis et al[47]United KingdomSingle centreRetrospectiveChart review49 pts; known or suspected CDCALPRO NovaTec Immunodiagnostica GmbH, Dietzenbac, GermanyPillCam®; Given®Imaging, Yokneam, Israel; MiroCam®; IntroMedic Co., Seoul, South KoreaAssess performance of 2 SBCE inflammation scoring systems (LS and CECDAI) correlating them with FC; Define threshold levels for CECDAI►LS performs better than CECDAI in describing SB inflammation, especially at FC < 100 μg/g
►CECDAI levels of 3.8 and 5.8 correspond to LS thresholds of 135 and 790, respectively
Sipponen et al[48]FinlandSingle centreProspectiveBlinded study84 pts; known or suspected CDCalprest® Eurospital SpA, Trieste, ItalyPillCam®; Given®Imaging, Yokneam, Israel; MiroCam®; IntroMedic Co., Seoul, South KoreaStudy the role of FC and S100A12 in predicting SB inflammatory lesions►CE abnormal in 35/84 (42%) pts: 14 CD, 8 NSAID-enteropathy, 8 angioectasias, 4 polyps/tumours, 1 ischemic stricture
►Median FC/S100A12: 22 μg/g (range: 2-342 μg/g)/0.048 μg/g (range: 0.003-1.215 μg/g)
►FC significantly higher in CD pts (median 91, range: 2-312) compared with pts with normal CE or other abnormalities (P = 0.008)
►Faecal S100A12 (0.087 μg/g, range: 0.008-0.896 μg/g): no difference between the groups (P = 0.166)
►Sens, Spec, PPV, NPV in detecting SB inflammation; FC (cut-off 50 μg/g): 59%, 71%, 42%, 83%; S100A12 (cut-off 0.06 μg/g): 59%, 66%, 38%, 82%, respectively
HAS CE THE SAME DIAGNOSTIC CAPABILITY ALONG THE SMALL BOWEL?

There are several papers, mostly case presentations and/or case series, reporting patients in whom CE failed to identify small-bowel lesions which were subsequently diagnosed by other modalities[49-52]. Such missed lesions (including neoplastic pathology) were occasionally large and often located in the proximal small-bowel[50,51]. Although there is still a lot of debate about the reasons of poor SBCE performance[53], it is worth remembering that for any non-steerable capsule progress is more rapid in the proximal than in lower segments of the small-bowel[53]; furthermore, opaque bile secretions and/or intra-luminal content might consequently hamper/prevent detailed mucosa visualization. Table 5 summarises all studies reporting the number of exams in which one of the few small-bowel landmarks, the ampulla of Vater (AoV), was visible during CE[54-66]. Hence, this evidence base provides an indirect confirmation of the limitations of SBCE in evaluating the proximal small-bowel. Interestingly, even in earlier studies[54] which have not been confirmed since by other investigators, the AoV was missed in > 50% of SBCE examinations. This is obviously an important drawback, especially when SBCE is used as surveillance tool, in patients with small-bowel polyposis syndromes.

Table 5 Studies looking at the identification rate of the ampulla in capsule endoscopy.
Ref.CEType of CE model; CompanyAoV seen, n (%)ReviewersReviewing speed (fps)Frames AoV visible2Comments
Wijeratne et al[53]1138NS9 (6.0)1NSNS4 FAP patients (AoV not seen)
Kong et al[54]110M2A®; Given®Imaging Ltd.48 (43.6)2153.5 ± 2.5
Clarke et al[55]125M2A®; Given®Imaging Ltd.13 (10.4)25NS
Iaquinto et al[56]23PillCam®SB; Given®Imaging Ltd.0 (0.0)2NSN/AFAP patients (11/23 had duodenal polyps)
Metzger et al[57]20PillCam®SB1; Given®Imaging Ltd.1 (5.0)NSNSNSRepeat examinations
PillCam®SB2; Given®Imaging Ltd.5 (25.0)NSNSNS
Katsinelos et al[58]14NS0 (0.0)1NSN/AFAP patients
Nakamura et al[59]96PillCam®SB1; Given®Imaging Ltd.18 (18.0)210NS
Karagiannis et al[60]10PillCam®Colon; Given®Imaging Ltd.6 (60.0)NSNSNSTwo-headed PillCam®
Lee et al[61]130PillCam®SB; Given®Imaging Ltd.13 (43.3)NSNSNS
30PillCam®SB2; Given®Imaging Ltd.15 (50.0)NSNSNS
50PillCam®SB1; Given®Imaging Ltd.0 (0.0)2NSN/A
Selby et al[62]50PillCam®SB2; Given®Imaging Ltd.9 (18.0)2NSNS
8PillCam®ESO1; Given®Imaging Ltd.0 (0.0)2NSN/ATwo-headed PillCam®
12PillCam®ESO2; Given®Imaging Ltd.1 (8.0)2NSNSTwo-headed PillCam®
Koulaouzidis et al[63]11PillCam®ESO1; Given®Imaging Ltd.4 (36.4)17NSTwo-headed PillCam®
7PillCam®ESO2; Given®Imaging Ltd.1 (14.3)19NSTwo-headed PillCam®
Park et al[64]30PillCam®SB; Given®Imaging Ltd.13 (43.3)673.1 ± 1.1
30PillCam®SB2; Given®Imaging Ltd.15 (50.0)693.1 ± 1.5
262PillCam®SB1; Given®Imaging Ltd.28 (10.7)1636.35 ± 73.24
Koulaouzidis et al[65]148PillCam®SB2; Given®Imaging Ltd.13 (8.8)1642.46 ± 69.3
209MiroCam®; IntroMedic Ltd.18 (8.6)1687.20 ± 248.4
Friedrich et al[66]25CapsoCam®SV1; Capsovision Ltd.22 (71)3NS3.1 ± 1.8
CAPSULE ENDOSCOPE ASPIRATION; HOW COMMON IS THIS?

Capsule enteroscopy is generally considered safe, having an overall complication rate of about 1%-3%[13,14]. Undoubtedly, the most feared complication of CE is capsule retention in the small bowel (overall retention rate 1.5%-2%), which seems directly related with the clinical indication for SBCE[13,14,40]. Interestingly enough, other possible complications - which were postulated at the time of CE introduction (i.e., retention inside colonic diverticula, interaction with pacemakers, etc.) to represent potential hurdles for the method, were shown to be very infrequent and/or without clinically relevant consequences[67-71]. Conversely, capsule aspiration - an unexpected complication - has been reported with increasing frequency (Table 6)[72-93]. Overall, this is probably related to the increase in the mean age of patients undergoing CE. In fact, capsule aspiration occurs in 1 out of 800-1000 procedures[88], mostly in elderly male patients with co-morbidities and/or swallowing disorders. In the majority of cases capsule aspiration resolves quickly, because patients expectorate the capsule. However, in selected cases, emergency bronchoscopy is required. Thus far, only one fatality-directly associated with capsule aspiration- has been reported[90].

Table 6 Case reports of aspiration of capsule endoscopes.
Ref.Case (age/gender)ComorbiditiesCE model/companySwallowing difficultiesNo. of attempts to swallow CE/gagging or coughingAspiration time/where in bronchial tree CE seenCapsule removal (if employed)Final diagnosis
Schneider et al[72]64/maleMechanical MV on phenprocoumon, BMI 15.5M2A®; Given®Imaging Ltd.No Hx of dysphagia4/gagging and spitting capsule - last attempt recurrent coughing (aspiration presumed)2 min/trachea-bronchiSpontaneous resolutionNS
Fleischer et al[73]76/maleHHTM2A®; Given®Imaging Ltd.No Hx of dysphagia1/lodged in his throat - no respiratory difficulty, could talk, vital signs normal60 min/cricopharyngeusEndoscopy-Roth net; 6 d post-dilation, patient ingested capsule with no problemSpasticity, prominence of cricopharyngeus; endoscopy and oesophageal dilation 1 wk later
Sinn et al[74]69/femaleOn phenprocoumonM2A®; Given®Imaging Ltd.No Hx of dysphagia1/coughed several times50 s/bifurcation of the tracheaSpontaneous resolutionNS
Tabib et al[75]87/femaleRecent onset IDA, CHF, IHD, AF, bladder cancer, CRFM2A®; Given®Imaging Ltd.No Hx of dysphagia, pre-CE barium meal2/choking, dyspnoea, CE felt lodged in the throatNS/right main-stem bronchus - bronchus intermediusRigid bronchoscopyNS
Buchkremer et al[76]74/maleRecent diagnosis of coeliac disease; past Hx of ankylosing spondylitisM2A®; Given®Imaging Ltd.No Hx of dysphagiaNS/dyspnoea started after CE ingestionNS/right main-stem bronchusFlexible bronchoscopyNS
Rondonotti et al[77]NSNSM2A®; Given®Imaging Ltd.NSNS/coughed several timesNS/NSSpontaneous resolutionNS
Nathan et al[78]93/maleNo significant past medical HxM2A®; Given®Imaging Ltd.No Hx of dysphagia1/coughed hours post-ingestionApproximately 8 h/bronchial treeSpontaneous resolutionNS
Shiff et al[79]75/maleNSM2A®; Given®Imaging Ltd.No Hx of dysphagia2/some coughingNS/bronchiSpontaneous resolutionNS
Eventually, CE endoscopic placement
Sepehr et al[80]67/maleHTN, DM, CVANSHx of dysphagia (intermittent)1/coughing, tachypnoea, and tachycardiaNS/tracheaEndoscopy-Roth netNS
Koulaouzidis et al[81]76/maleNSPillCam®SB; Given®Imaging Ltd.No Hx of dysphagia1/coughed weakly15 s/tracheaSpontaneous resolutionNS
Guy et al[82]90/maleIschaemic CVANSNo Hx of dysphagiaNS/no symptomsNS/bronchial treeRigid bronchoscopy - stone retrieval basketNS
Leeds et al[83]85/maleNSNSNo Hx of dysphagiaNS/difficulty swallowing CE, slightly painful8 h/lobar bronchusSpontaneous resolutionNS
Bredenoord et al[84]65/maleSigmoid colectomy for diverticulae; Ileal carcinoid resectedNSHx of dysphagiaLengthy swallowing attempt/coughing notedNS/right main bronchusSpontaneous resolution, eventually, CE was swallowed on same sessionNormal small-bowel
Choi et al[85]75/malePrior CVAPillCam®SB; Given®Imaging Ltd.No Hx of dysphagiaNS/coughed several times2 h/left main bronchusFlexible Bronchoscopy-Roth net and bronchial wall irrigation to induce coughNS, patient declined further investigations
Depriest et al[86]90/maleIHD, AF, PVD (warfarin + clopidogrel)PillCam®SB; Given®Imaging Ltd.No Hx of dysphagiaNS/some coughNS/left main bronchus, then right main bronchusChest percussive therapy + postural drainage; Flexible bronchoscopy + extraction basket + Roth netNS
Depriest et al[86]90/maleIHD, AF, PVD (warfarin + clopidogrel)PillCam®SB; Given®Imaging Ltd.No Hx of dysphagiaNS/some coughNS/left main bronchus, then right main bronchusChest percussive therapy + postural drainage; flexible bronchoscopy + extraction basket + Roth netNS
Kurtz et al[87]73/maleRenal cell cancer, MV (bovine), hyperlipidaemia, melaenaNSNo Hx of dysphagiaSips of water, 1st attempt, 2 min later non-productive cough (20 s)Level of carina; then right main stem bronchusBronchoscopy-retrieval basket (multiple spontaneous ejections from trachea prior bronchoscopy)NS
Lucendo et al[88]80/maleAdvanced PD, DM, walking + speech difficultiesPillCam®SB; Given®Imaging Ltd.No Hx of dysphagiaSeveral attempts/persistent coughing and some dyspnoea20 s/tracheobronchial treeSpontaneous resolutionOesophageal ulcer + ileal ulcer
Pezzoli et al[89]82/maleUnexplained anemia, HTNNSNo Hx of dysphagiaNS/asymptomatic (minimal cough)3 d/in the right bronchusSpontaneous resolutionNS
Parker et al[90]77/femaleHysterectomyNSNo Hx of dysphagiaInitial attempt unsuccessful/chocking episode, CE coughed-upNS/NSSpontaneous resolution, endoscopic placement with AdvanCE® devicePatient suffered intracranial bleed, eventually succumbed
Despott et al[91]65/maleCOPD, cirrhosis, pancreatitisNSNo Hx of dysphagiaNS/asymptomaticNS/right main bronchusRigid bronchoscopy-Roth netEndoscopic placement with AdvanCE® device
73/maleCOPDNSNSNS/brief coughingNS/left main bronchusBronchoscopy-snare + Roth netEndoscopic placement with AdvanCE® device
81/maleNSNSNSNS/fleeting choking sensationNS/right main bronchusRigid bronchoscopy-crocodile grasping forcepsNS
Girdhar et al[92]83/maleCOPD, GORDPillCam®SB; Given®Imaging Ltd.No Hx of dysphagiaDifficult, requiring multiple sips of water/some cough, after 1 h mild shortness of breathNS/left main bronchusFlexible bronchoscopy + rat-tooth alligator forceps + stiff-wire basket with a pin-vise handleNS
Poudel et al[93]80/maleAF, IHD, CVA on anti-coagulants, anaemia + melaenaM2A®; Given®Imaging Ltd.NSNS24 h/left main stem bronchus; then right bronchusFlexible bronchoscopy + net + snare forceps + tripod; eventually, grasped with basketNS
CAN WE SHORTEN OUR READING TIME IN CAPSULE ENDOSCOPY?

Few will disagree with the notion that CE is a time-consuming procedure. In fact, although capsule administration and swallowing requires only a couple of minutes, SBCE transit through the small bowel, although variable, on overage lasts about 2-5 h[94]. This results in 14400-72000 frames, depending on capsule frame rate (Table 1). This large amount of visual information requires careful evaluation by the CE reader. In addition, any small-bowel lesion may only be visible in just a few or even in a single frame[95]. Therefore, focused and undivided attention is required for the entire duration of each CE video evaluation. In light of all that, several attempts have been made to develop technical software features, in order to make CE video analysis easier and shorter (without jeopardising its accuracy). The first software feature designed for this purpose was the Suspected Blood Indicator (SBI), an automatic system able to pick up, in a completely automatic fashion, frames containing several red pixels and, therefore (theoretically), to detect blood and or other red-coloured lesions. Nevertheless, the accuracy profile of this tool (Table 7) is suboptimal and, at present time[96-102], it can be used only as supportive tool[102].

Table 7 Studies looking at the clinical validity of Suspected Blood Indicator, feature of capsule endoscopy reading software, in small-bowel capsule endoscopy.
Ref.CountryCentreObjective(s)Study typeDesignCE typeOutcome(s)Conclusions
Gross et al[96]United StatesSingle centreAccuracy of SBI to number of blood transfusionsRetrospective►Gold standard for lesions detected by experienced CE reviewerM2A; Given® Imaging Ltd.►Gold standard: 72 pts;Pts receiving blood transfusions are more likely to have a positive SBI correlating with the localization of active bleeding
►pts received blood transfusions ranging between 0-16 units;
►Overall: A total of 17 pts had positive SBI. Active bleeding in 16 pts, who were transfused an average of 8 units before the study;
►55 pts had a negative SBI and no active bleeding was seen on their capsule studies. In this group, the average number of PRBC transfused was 1 unit. There was one patient who had a false positive SBI with no active bleeding seen in the capsule study review
Liangpunsakul et al[97]United StatesSingle centreAssess accuracy of SBIRetrospective►Gold standard for lesions detected by experienced CE reviewer;M2A; Given® Imaging Ltd.►Gold standard: 109 lesions;SBI has good Sens and PPV for actively bleeding SB lesions
►SBI: 31 potential areas of blood; correctly identified lesions: 28;
►Significant lesions considered AVMs, ulcers, erosions, active bleeding;►Overall: SBI (Sens, PPV, accuracy): 25.7%, 90%, 34.8%, respectively;
►For actively bleeding SB lesions only: SBI (Sens, PPV, accuracy): 81.2%, 81.3%, 83.3%, respectively
►Reviewing speed: 15fps
D'Halluin et al[98]FranceMulti-centre (7 centres)Assess Sens/Spec of SBI (in OGIB)Retrospective►Gold standard for lesions detected by experienced CE reviewer, SBI tags marked by another investigator;M2A; Given® Imaging Ltd.►156 SBCE recordings evaluated: In 83 (normal): either no lesion (n = 71) or P0 lesion (n = 12); in 73 abnormal: P2 (n = 114) and P1 (n = 92) lesions;►SBI-based detection of SB lesions (with bleeding potential) is of limited clinical value
►Significant lesions considered Bleeding or having a bleeding potential: high (P2), low (P1), or absent (P0);►154 red tags analysed: SBI (Sens, Spec, PPV, NPV) for P2 or P1: 37%, 59%, 50%, 46%, respectively
►Concordance: same time code in frames selected by expert reader and those tagged by SBI;
►Reviewing speed: NS
Singnorelli et al[99]ItalySingle centreAssess Sens/Spec of SBI per lesion, overall, according to red findings (identified by the reader), and per patientRetrospective►Gold standard for lesions detected by four experienced CE reviewers;M2A; Given® Imaging Ltd.►95 patients; 209 red findings;►SBI has low Sens/Spec in per-lesion and per-patient SBCE evaluation;
►Overall Sens: 28%;
►Outcomes: Sens, Spec and accuracy calculated both per lesion/patient;►Sens higher for identification of blood (61%) than for nonbleeding “red” findings, e.g., AVMs (26%);
►Reviewing speed: NS►Per-patient Sens, Spec: 41%, 70%, respectively►Complementary/rapid screening tool;
►Complete review of the recordings is still necessary
Ponferrada et al[100]SpainSingle centreAssess accuracy/performance of SBIProspective►Gold standard for lesions detected by experienced CE reviewersM2A; Given® Imaging Ltd.►57 consecutive patients;
►Indications: OGIB (64.9%), CD (14%), malabsorption (14%), suspicion of SB tumour (7.1%);
►SBI Sens, Spec, PPV, NPV: 58.3%, 75.5%, 38.8%, 87.2%, respectively
Buscaglia et al[101]United StatesSingle centreAssess accuracy/performance of SBI according to CE indicationsRetrospective►Gold standard for lesions detected by experienced CE reviewer;M2A; Given® Imaging Ltd.►CE indications: OGIB (n = 112), suspected CD (n = 122), anaemia of unknown origin (n = 53), other (n = 4);►SBI performance characteristics suboptimal/insufficient to screen for SB lesions with bleeding potential;
►Significant lesions:AVMs, varices, venous ectasias, red spots, ulcers, erosions, blood, blood clots►221 lesions with bleeding potential;
►Overall: SBI (Sens, Spec, PPV, NPV): 56.4%, 33.5%, 24.0%, 67.3%, respectively;
►Concordant and discordant findings between CE reviewer and SBI;
►For actively bleeding lesions: SBI (Sens, PPV): 58.3%, 70%, respectively;►Even in pts with active intestinal bleeding, SBI Sens was only < 60%
►Reviewing speed: 8-15 fps►For suspected CD: SBI (Sens, NPV): 64%, 80.4%, respectively;
►For OGIB: SBI Sens 58.3%;
►For anaemia: SBI Sens 41.3%;
Park et al[102]South KoreaSingle centreInvestigate whether SBI is affected by background colour and CE velocityExperimental►Paper-made phantom SB models in a variety of colours to simulate the background colours observed in CE;M2A; Given® Imaging Ltd.►SBI red spots detection rate differed significantly per background colour of SB model, P < 0.001;►SBI Sens affected by background colour and capsule passage velocity in the models
►SBI red spots detection rate highest for very pale magenta, burnt sienna, yellow background;
►Red spots were attached inside them;
►CE manually passed through models;
►SBI red spots detection rate was evaluated based on colours of SB models and CE velocities (0.5, 1, 2 cm/s)►SBI red spots detection rate lowest for dark brown, very pale yellow background

Given®Imaging Ltd. has also introduced another software tool, which aims specifically at shortening the CE reading time, the QuickView. This sampling tool is able to select one frame every X CE frames (the sampling rate can be set by the reader) and therefore present, with the click of a tag-button, a shortened CE video which can be reviewed in a few minutes. Although the sampling method of the QuickView system is only quantitative, it has showed a promising sensitivity and specificity in identifying small-bowel lesions (Table 8), and reveals promising potential when coupled with other image enhancing systems[104-112]. Olympus has similar software function (express mode) and we are aware of a single relevant study with very similar results[113].

Table 8 Studies looking at the clinical validity of QuickView, feature of capsule endoscopy reading software, in small-bowel capsule endoscopy.
Ref.QuickView sampling rateQuickView reading frame mode/reading speed (fps)Average reading time (mean)Comparison with/reading frame mode/reading speed used (fps)Rapid®Reader versionReviewersCases
QuickView
Lesions missed
TotalOGIBCDPolyposisOtherSensitivity (%)Specificity (%)
Ponferrada et al[100]NS25, 15, 5NSConventional/NS/15, 15, 5257378N/A1296.5 (5 fps)NSNS
Schmelkin[104]NSNSNSNS4.014747N/AN/AN/A100100N/A
Appalaneni et al[105]NSSingle frame, 253 minNSNS250NSNSNSNSNSNS2
Westerhof et al[106]High (17)NS4.4 min (median)Conventional/dual view/184.021005630212NSNS13
Shiotani et al[107]High (17)Single, 617.9 minNS5.0344NSNSNS14NSNS10
Hosoe et al[108]NormalNSNSNS5.0345NSNSNS14NSNSNS
Saurin et al[109]NSNS11.6 minConventional/NS/NS5.012106106N/AN/AN/A89.2Jul-848
Shiotani et al[110]5, 15, 25, 35Single, NSNSNS6.5487NSNSNSNSNSNSNS
Koulaouzidis et al[111]35Dual view (WL + BM)475 s (QuickView WL)Conventional/single or dual view/12-207.01200106814992.3 (QVWL P1 + P2)96.3 (QVWL P1 + P2)
18450 s (QuickView BM)91 (QVBM P1+P2)96 (QVBM P1 + P2)
Kyriakos et al[112]NSNS, 316.3 min (6.7)Conventional/NS/NS5.021005522320NSNS12

In the last few years, Given®Imaging Ltd., through a collaboration with Fujinon Inc., Japan introduced the electronic chromo-endoscopy (Fujinon Intelligent Chromo Endoscopy, FICE) in the field of capsule enteroscopy. Data available thus far, show that application of FICE in SBCE videos, leads to improved image quality and definition of the surface texture of small-bowel lesions (Table 9)[114-120]. Although this seems to facilitate the detectability of small-bowel findings, it is still under question whether it proves to be clinically significant[121]. Similar function from Olympus Inc., shows promising results[122].

Table 9 Studies looking at the clinical validity of Fujinon® intelligent chromoendoscopy enhancement/Blue mode, feature of capsule endoscopy reading software, in small-bowel capsule endoscopy.
Ref.CountryCentreStudy typeObjective(s)DesignImagesFICECEOutcome(s)
Imagawa et al[114]JapanSingle centreRetrospectiveAssess whether visualization of SB lesions improves with FICE►5 experienced readers compared CE-WL images to their FICE counterparts►Angiectasis (n = 23);FICE 1,2,3PillCam®SB1; Given®Imaging Ltd.►FICE 1: AVMs: improvement in 87% (20/23) cases; erosion/ulceration: improvement 53.3% (26/47) cases; tumour images: improvement 25.3% (19/75) cases;
►Erosion/ulcers (n = 47);
►FICE 2: AVMs: improvement in 87% (20/23) cases; erosion/ulceration: improvement in 25.5% (12/47) cases; tumour images: improvement in 20.0% (15/75) cases;
►Tumour (n = 75)
►FICE 3: All images groups: only equivalence achieved in all cases; intra-observer agreement: good to satisfactory (5.4 or higher)
Imagawa et al[115]JapanSingle centreProspectiveAssess whether FICE improves detection rate of SB lesions in CE►A CE reader reviewed CE-WL videos;50 ptsFICE 1,2,3PillCam®SB1; Given®Imaging Ltd.►Angioectasias detection: CE-WL: 17 AVMs; CE-FICE 1: 48 AVMs; CE-FICE 2: 45 AVMs; CE-FICE 3: 24 AVMs; significant CE-FICE 1 and 2 (P = 0.0003 and P < 0.0001, respectively)
►Another reader, reviewed CE-FICE videos with FICE 1,2,3
►Detection rate for erosion, ulceration and tumour did not differ statistically between CE-WL and CE-FICE 1,2,3;
Gupta et al[116]BelgiumSingle centreRetrospectiveAssess potential benefit of FICE for SB lesion detection in patients with OGIBCE videos analysed by 2 GI fellows with and without FICE 1,2,3;60 pts with OGIBFICE 1,2,3PillCam®SB1; Given®Imaging Ltd.►Overall, 157 lesions diagnosed with CE-FICE vs 114 with CE-WL (P = 0.15);
►For P2 lesions; CE-FICE Sens/Spec: 94%/95% vs CE-WL Sens/Spec: 97%/96%, respectively; 5/55 AVMs better characterized with CE-FICE than CE-WL
Reference standard: Senior consultant described findings as P0, P1 and P2 lesions
►More P0 diagnosed by CE-FICE than CE-WL (39 vs 8, P < 0.001);
►Intra-class kappa correlations between fellows and reference: CE-FICE vs CE-WL for P2 lesions: 0.88 vs 0.92; CE-FICE vs CE-WL for P1 lesions: 0.61 vs 0.79
Krystallis et al[117]United KingdomSingle centreRetrospectiveAssess FICE and Blue mode visualisation of SB lesions in CE►2 experienced reviewers CE-WL images to FICE/Blue mode counterparts►Angioectasias (n = 18);Blue mode; FICE 1,2,3Pillcam®SB1/SB2; Given®Imaging Ltd.►Total of 167 images, for all lesion categories:
►Erosion/ulcers (n = 60);►Blue mode vs WL: image improvement in 83%; κ = 0.786
►Villi oedema (n = 17);►FICE 1 vs WL: image improvement in 34%; κ = 0.646
►Cobblestone (n = 11);►FICE 2 vs WL: image improvement in 8.6%; κ = 0.617
►Blood lumen (n = 15);►FICE 3 vs WL: image improvement in 7.7%; κ = 0.669
►LICS/other (n = 46)
Duque et al[118]PortugalSingle centreProspectiveAssess reproducibility and diagnostic accuracy of CE-FICE►4 physicians reviewed 150 FICE images;20 patients with OGIBBlue mode; FICE 1,2,3PillCam®SB2; Given®Imaging Ltd.►Concordance between the 4 gastroenterologists: 0.650;
►CE-WL identified 75 findings and the CE-FICE 95;
►2 experienced physicians analysed 20 CE; 1 interpreted CE-WL; the other, CE-FICE videos►CE-FICE did not miss any lesions identified by CE-WL and allowed the identification of a higher number of AVMs (35 vs 32) and erosions (41 vs 24)
Nakamura et al[119]JapanSingle centreProspectiveAssess preview of angioectasias by CE-FICE preview (compared to CE-WL)►One experienced physician analysed CEs in QuickView mode;50 pts with angiodysplasia were randomly assigned to 2 equally sized groups of CE-WL reading and CE-FICE readingSBI; Blue mode; FICE 1,2,3PillCam®SB2; Given®Imaging Ltd.►Mean reading time: 14min for both CE-WL and CE-FICE reading;
►The two previews for angiodysplasia were significantly superior to the function of SBI (P < 0.01);
►Mean reading time, sensitivity and specificity for angiodysplasia detection were evaluated including SBI
►Sens and Spec of CE-WL: 80% and 100%, respectively;
►Sens and Spec of CE-FICE: 91% and 86%, respectively;
►FICE reading was superior in Sens, while it resulted in more false (+) ve lesion findings and lower Spec
Sakai et al[120]JapanSingle centreProspective►Assess whether CE-FICE improves detectability of SB lesions by CE trainees and if it contributes to reducing the bile-pigment effect;►4 gastroenterology trainees interpreted 12 CE videos with WL and FICE 1,2,3;►60 AVMs; ►82 erosions/ulcersFICE 1,2,3PillCam®SB2; Given®Imaging Ltd.►60 angioectasias; CE trainees identified: 26 by CE-WL, 40 by CE-FICE1, 38 by CE-FICE2, 31 by CE-FICE3;
►82 erosions/ulcerations, CE trainees identified: 38 by CE-WL, 62 by CE-FICE1, 60 CE- FICE2, 20 by CE-FICE3;
►Lesion detection rate under each of the three FICE settings was compared with that by conventional CE-WL
►CE-FICE 1 and 2 significantly improved detectability of angioectasias (P = 0.0017 and P = 0.014, respectively) and erosions/ulcers (P = 0.0012 and P = 0.0094, respectively);
►Evaluate whether poor bowel preparing affects the accuracy of lesion recognition by FICE►Detectability of SB lesions by CE-FICE1 was not affected (P = 0.59) by the presence of bile-pigments;
►Detectability of SB lesions by CE-WL (P = 0.020) and CE-FICE2 (P = 0.0023) was reduced by the presence of bile-pigments;
►In poor bowel visibility conditions, CE-FICE yielded a high rate of false-positive findings
WHAT’S NEW ON THE FIELD OF SMALL-BOWEL CAPSULE ENDOSCOPY?

As aforementioned, there are differences among different capsule models (Table 1). Since its introduction in clinical practice in 2001, CE technology has been significantly. For instance, battery life is longer, image capture frame rate has increased, angle of view is now wider, light control has been optimized, and many real time viewing systems are now available. Nevertheless, these impressive advancements, do not allow overcoming the main current limitation of CE, i.e., uncontrolled propulsion; CE relies totally on natural bowel peristalsis, i.e., it still remains a rather “passive” diagnostic technique.

Several research groups are working to design brand new capsules able to actively move or to be remotely manoeuvred through their descent in the small bowel[123]. These new capsules would allow not only recognizing a small bowel lesion but also, in a near future, to collect targeted tissue samples or to deliver drugs (Table 10)[124-141].

Table 10 Experimental and models in development for capsule-endoscopy the future?.
Ref.ProjectStatusActive actuationMagnetic propulsionTherapeutic capabilities
Johannessen et al[124]IDEAS: A miniature lab-in-a-pill multi-Sens or microsystemPrototypeNoYesYes
Karagozler et al[125]Miniature endoscopy capsule robot using biomimetic micro-patterned adhesivesPrototypeYesNoNo
Quirini et al[126]An approach to capsular endoscopy with active motionPrototypeYesNoNo
Valdastri et al[127]Wireless therapeutic endoscopic capsule: in vivo experimentPrototypeNoYesYes
Glass et al[128]A legged anchoring mechanism for capsule endoscopes using micro-patterned adhesivesPrototypeYesNoNo
Valdastri et al[129]An endoscopic capsule robot: a meso-scale engineering case studyConceptYesNoNo
Tortora et al[130]Propeller-based wireless device for active capsular endoscopy in the gastric districtPrototypeYesNoNo
Valdastri et al[131]A magnetic internal mechanism for precise orientation of the camera in wireless endoluminal applicationsPrototypeNoYesNo
Ciuti et al[132]Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal proceduresPrototypeNoYesYes
Bourbakis et al[133]Design of new-generation robotic capsules for therapeutic and diagnostic endoscopyConceptYesNoYes
Gao et al[134]Design and fabrication of a magnetic propulsion system for self-propelled capsule endoscopeConceptNoYesNo
Simi et al[135]Design, fabrication, and testing of a capsule with hybrid locomotion for gastrointestinal tract explorationConceptNoYesNo
Morita et al[136]A further step beyond wireless capsule endoscopyConceptNoYesNo
Yang et al[137]Autonomous locomotion of capsule endoscope in gastrointestinalConceptYesNoNo
Filip et al[138]Electronic stool (e-Stool): A novel self-stabilizing video capsule endoscope for reliable non-invasive colonic imagingPrototypeYesNoNo
Yim et al[139]Design and rolling locomotion of a magnetically actuated soft capsule endoscopePrototypeYesNoNo
Kong et al[140]A robotic biopsy device for capsule endoscopyPrototypeYesNoYes
Woods et al[141]Wireless capsule endoscope for targeted drug delivery: Mechanics and design considerationsPrototypeYesNoYes
CONCLUSION

Since CE introduction in clinical practice in 2001, over 1500 papers, focused on SBCE, have been published (PubMed search 17/03/2012; keyword term: “small bowel capsule endoscopy”; available from: http://www.ncbi.nlm.nih.gov/pubmed/?term=small+bowel+capsule+endoscopy).

Out of those, < 20% are clinical trials; case reports and reviews account for about 40% of published evidence. As the amount of information has increased exponentially, and in fact continues to do so[12], it is often difficult for the busy clinician to retrieve and filter data or extract answers to questions arising from the daily clinical practice. In the present review, we opted to answer certain pertinent questions on contentious and important issues in CE through comprehensive tables. Essentially, we aim to present an easy-to-read review with all the necessary evidence to support opinions expressed herein.

The analysis of the publications listed in the tables clearly demonstrates how SBCE, although much “younger” than other endoscopic techniques, has found a definite role in the diagnostic work-up of certain patient-subgroups. Further success of this modality depends not only on continuous technological progress (i.e., introduction of new capsule models, improved battery life and/or development of new reading software features)[142] but also on the search for new diagnostic strategies, aiming to select for SBCE those patients with higher potential for positive DY[32,45,81,111,117].

Certain issues (i.e., best small-bowel preparation for CE[143,144], occurrence of some potentially life-threatening complications, visualisation quality of the proximal small-bowel) remain open and they will surely be the target of further clinical studies and technical improvements.

Footnotes

P- Reviewer Driscoll D S- Editor Wen LL L- Editor A E- Editor Xiong L

References
1.  Gong F, Swain CP, Mills TN. An endorobot for gastrointestinal endoscopy. Gut. 1994;35:S52.  [PubMed]  [DOI]  [Cited in This Article: ]
2.  Adler SN, Bjarnason I. What we have learned and what to expect from capsule endoscopy. World J Gastrointest Endosc. 2012;4:448-452.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 12]  [Cited by in F6Publishing: 12]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
3.  Iddan G, Meron G, Glukhovsky A, Swain P. Wireless capsule endoscopy. Nature. 2000;405:417.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 1994]  [Cited by in F6Publishing: 1330]  [Article Influence: 55.4]  [Reference Citation Analysis (0)]
4.  Muñoz-Navas M. Capsule endoscopy. World J Gastroenterol. 2009;15:1584-1586.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 38]  [Cited by in F6Publishing: 25]  [Article Influence: 1.7]  [Reference Citation Analysis (0)]
5.  Eliakim R. Video capsule endoscopy of the small bowel. Curr Opin Gastroenterol. 2013;29:133-139.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 54]  [Cited by in F6Publishing: 56]  [Article Influence: 5.1]  [Reference Citation Analysis (0)]
6.  Fisher LR, Hasler WL. New vision in video capsule endoscopy: current status and future directions. Nat Rev Gastroenterol Hepatol. 2012;9:392-405.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 50]  [Cited by in F6Publishing: 56]  [Article Influence: 4.7]  [Reference Citation Analysis (0)]
7.  Hartmann D, Eickhoff A, Damian U, Riemann JF. Diagnosis of small-bowel pathology using paired capsule endoscopy with two different devices: a randomized study. Endoscopy. 2007;39:1041-1045.  [PubMed]  [DOI]  [Cited in This Article: ]
8.  Cave DR, Fleischer DE, Leighton JA, Faigel DO, Heigh RI, Sharma VK, Gostout CJ, Rajan E, Mergener K, Foley A. A multicenter randomized comparison of the Endocapsule and the Pillcam SB. Gastrointest Endosc. 2008;68:487-494.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 88]  [Cited by in F6Publishing: 72]  [Article Influence: 4.5]  [Reference Citation Analysis (0)]
9.  Kim HM, Kim YJ, Kim HJ, Park S, Park JY, Shin SK, Cheon JH, Lee SK, Lee YC, Park SW. A Pilot Study of Sequential Capsule Endoscopy Using MiroCam and PillCam SB Devices with Different Transmission Technologies. Gut Liver. 2010;4:192-200.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 33]  [Cited by in F6Publishing: 34]  [Article Influence: 2.4]  [Reference Citation Analysis (0)]
10.  Pioche M, Gaudin JL, Filoche B, Jacob P, Lamouliatte H, Lapalus MG, Duburque C, Chaput U, Ben Soussan E, Daudet J. Prospective, randomized comparison of two small-bowel capsule endoscopy systems in patients with obscure GI bleeding. Gastrointest Endosc. 2011;73:1181-1188.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 40]  [Cited by in F6Publishing: 46]  [Article Influence: 3.5]  [Reference Citation Analysis (0)]
11.  Dolak W, Kulnigg-Dabsch S, Evstatiev R, Gasche C, Trauner M, Püspök A. A randomized head-to-head study of small-bowel imaging comparing MiroCam and EndoCapsule. Endoscopy. 2012;44:1012-1020.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 27]  [Cited by in F6Publishing: 25]  [Article Influence: 2.1]  [Reference Citation Analysis (0)]
12.  Liao Z, Gao R, Li F, Xu C, Zhou Y, Wang JS, Li ZS. Fields of applications, diagnostic yields and findings of OMOM capsule endoscopy in 2400 Chinese patients. World J Gastroenterol. 2010;16:2669-2676.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 59]  [Cited by in F6Publishing: 43]  [Article Influence: 3.1]  [Reference Citation Analysis (0)]
13.  Liao Z, Gao R, Xu C, Li ZS. Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review. Gastrointest Endosc. 2010;71:280-286.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 472]  [Cited by in F6Publishing: 431]  [Article Influence: 30.8]  [Reference Citation Analysis (0)]
14.  Rondonotti E, Soncini M, Girelli C, Ballardini G, Bianchi G, Brunati S, Centenara L, Cesari P, Cortelezzi C, Curioni S. Small bowel capsule endoscopy in clinical practice: a multicenter 7-year survey. Eur J Gastroenterol Hepatol. 2010;22:1380-1386.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 52]  [Cited by in F6Publishing: 49]  [Article Influence: 3.5]  [Reference Citation Analysis (0)]
15.  Rondonotti E, de Franchis R. Diagnosing coeliac disease: is the videocapsule a suitable tool? Dig Liver Dis. 2007;39:145-147.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 11]  [Cited by in F6Publishing: 14]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
16.  Pennazio M, Rondonotti E, de Franchis R. Capsule endoscopy in neoplastic diseases. World J Gastroenterol. 2008;14:5245-5253.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 47]  [Cited by in F6Publishing: 41]  [Article Influence: 2.6]  [Reference Citation Analysis (0)]
17.  Marmo R, Rotondano G, Piscopo R, Bianco MA, Cipolletta L. Meta-analysis: capsule enteroscopy vs. conventional modalities in diagnosis of small bowel diseases. Aliment Pharmacol Ther. 2005;22:595-604.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 153]  [Cited by in F6Publishing: 122]  [Article Influence: 6.4]  [Reference Citation Analysis (0)]
18.  Triester SL, Leighton JA, Leontiadis GI, Fleischer DE, Hara AK, Heigh RI, Shiff AD, Sharma VK. A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with obscure gastrointestinal bleeding. Am J Gastroenterol. 2005;100:2407-2418.  [PubMed]  [DOI]  [Cited in This Article: ]
19.  Leighton JA, Triester SL, Sharma VK. Capsule endoscopy: a meta-analysis for use with obscure gastrointestinal bleeding and Crohn’s disease. Gastrointest Endosc Clin N Am. 2006;16:229-250.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 69]  [Cited by in F6Publishing: 73]  [Article Influence: 4.1]  [Reference Citation Analysis (0)]
20.  Triester SL, Leighton JA, Leontiadis GI, Gurudu SR, Fleischer DE, Hara AK, Heigh RI, Shiff AD, Sharma VK. A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with non-stricturing small bowel Crohn’s disease. Am J Gastroenterol. 2006;101:954-964.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 392]  [Cited by in F6Publishing: 355]  [Article Influence: 19.7]  [Reference Citation Analysis (0)]
21.  Pasha SF, Leighton JA, Das A, Harrison ME, Decker GA, Fleischer DE, Sharma VK. Double-balloon enteroscopy and capsule endoscopy have comparable diagnostic yield in small-bowel disease: a meta-analysis. Clin Gastroenterol Hepatol. 2008;6:671-676.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 270]  [Cited by in F6Publishing: 255]  [Article Influence: 15.9]  [Reference Citation Analysis (0)]
22.  Niv Y. Efficiency of bowel preparation for capsule endoscopy examination: a meta-analysis. World J Gastroenterol. 2008;14:1313-1317.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 70]  [Cited by in F6Publishing: 70]  [Article Influence: 4.4]  [Reference Citation Analysis (1)]
23.  El-Matary W, Huynh H, Vandermeer B. Diagnostic characteristics of given video capsule endoscopy in diagnosis of celiac disease: a meta-analysis. J Laparoendosc Adv Surg Tech A. 2009;19:815-820.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 22]  [Cited by in F6Publishing: 22]  [Article Influence: 1.6]  [Reference Citation Analysis (0)]
24.  Chen X, Ran ZH, Tong JL. A meta-analysis of the yield of capsule endoscopy compared to double-balloon enteroscopy in patients with small bowel diseases. World J Gastroenterol. 2007;13:4372-4378.  [PubMed]  [DOI]  [Cited in This Article: ]
25.  Rokkas T, Papaxoinis K, Triantafyllou K, Pistiolas D, Ladas SD. Does purgative preparation influence the diagnostic yield of small bowel video capsule endoscopy?: A meta-analysis. Am J Gastroenterol. 2009;104:219-227.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 119]  [Cited by in F6Publishing: 133]  [Article Influence: 8.9]  [Reference Citation Analysis (0)]
26.  Dionisio PM, Gurudu SR, Leighton JA, Leontiadis GI, Fleischer DE, Hara AK, Heigh RI, Shiff AD, Sharma VK. Capsule endoscopy has a significantly higher diagnostic yield in patients with suspected and established small-bowel Crohn’s disease: a meta-analysis. Am J Gastroenterol. 2010;105:1240-1248; quiz 1249.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 262]  [Cited by in F6Publishing: 253]  [Article Influence: 18.1]  [Reference Citation Analysis (0)]
27.  Wu L, Cao Y, Liao C, Huang J, Gao F. Systematic review and meta-analysis of randomized controlled trials of Simethicone for gastrointestinal endoscopic visibility. Scand J Gastroenterol. 2011;46:227-235.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 78]  [Cited by in F6Publishing: 86]  [Article Influence: 6.6]  [Reference Citation Analysis (0)]
28.  Cohen SA, Klevens AI. Use of capsule endoscopy in diagnosis and management of pediatric patients, based on meta-analysis. Clin Gastroenterol Hepatol. 2011;9:490-496.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 49]  [Cited by in F6Publishing: 55]  [Article Influence: 4.2]  [Reference Citation Analysis (0)]
29.  Teshima CW, Kuipers EJ, van Zanten SV, Mensink PB. Double balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding: an updated meta-analysis. J Gastroenterol Hepatol. 2011;26:796-801.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 173]  [Cited by in F6Publishing: 193]  [Article Influence: 14.8]  [Reference Citation Analysis (0)]
30.  Belsey J, Crosta C, Epstein O, Fischbach W, Layer P, Parente F, Halphen M. Meta-analysis: efficacy of small bowel preparation for small bowel video capsule endoscopy. Curr Med Res Opin. 2012;28:1883-1890.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 50]  [Cited by in F6Publishing: 53]  [Article Influence: 4.4]  [Reference Citation Analysis (0)]
31.  Rokkas T, Niv Y. The role of video capsule endoscopy in the diagnosis of celiac disease: a meta-analysis. Eur J Gastroenterol Hepatol. 2012;24:303-308.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 71]  [Cited by in F6Publishing: 72]  [Article Influence: 6.0]  [Reference Citation Analysis (0)]
32.  Koulaouzidis A, Rondonotti E, Giannakou A, Plevris JN. Diagnostic yield of small-bowel capsule endoscopy in patients with iron-deficiency anemia: a systematic review. Gastrointest Endosc. 2012;76:983-992.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 84]  [Cited by in F6Publishing: 82]  [Article Influence: 6.8]  [Reference Citation Analysis (0)]
33.  Sidhu R, Sanders DS, Morris AJ, McAlindon ME. Guidelines on small bowel enteroscopy and capsule endoscopy in adults. Gut. 2008;57:125-136.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 155]  [Cited by in F6Publishing: 171]  [Article Influence: 10.7]  [Reference Citation Analysis (0)]
34.  Fisher L, Lee Krinsky M, Anderson MA, Appalaneni V, Banerjee S, Ben-Menachem T, Cash BD, Decker GA, Fanelli RD, Friis C. The role of endoscopy in the management of obscure GI bleeding. Gastrointest Endosc. 2010;72:471-479.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 184]  [Cited by in F6Publishing: 162]  [Article Influence: 11.6]  [Reference Citation Analysis (0)]
35.  Ladas SD, Triantafyllou K, Spada C, Riccioni ME, Rey JF, Niv Y, Delvaux M, de Franchis R, Costamagna G. European Society of Gastrointestinal Endoscopy (ESGE): recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases. Endoscopy. 2010;42:220-227.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 167]  [Cited by in F6Publishing: 165]  [Article Influence: 11.8]  [Reference Citation Analysis (0)]
36.  Rondonotti E, Marmo R, Petracchini M, de Franchis R, Pennazio M. The American Society for Gastrointestinal Endoscopy (ASGE) diagnostic algorithm for obscure gastrointestinal bleeding: eight burning questions from everyday clinical practice. Dig Liver Dis. 2013;45:179-185.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 48]  [Cited by in F6Publishing: 52]  [Article Influence: 4.7]  [Reference Citation Analysis (0)]
37.  Niv E, Ovadia B, Ron Y, Santo E, Mahajna E, Halpern Z, Fireman Z. Ensure preparation and capsule endoscopy: a two-center prospective study. World J Gastroenterol. 2013;19:1264-1270.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 6]  [Cited by in F6Publishing: 6]  [Article Influence: 0.5]  [Reference Citation Analysis (0)]
38.  Rondonotti E, Soncini M, Girelli C, Villa F, Russo A, de Franchis R. Cost estimation of small bowel capsule endoscopy based on “real world” data: inpatient or outpatient procedure? Dig Liver Dis. 2010;42:798-802.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 6]  [Cited by in F6Publishing: 7]  [Article Influence: 0.5]  [Reference Citation Analysis (0)]
39.  McAlindon ME, Parker CE, Hendy P, Mosea H, Panter S, Davison C, Fraser C, Despott EJ, Sidhu R, Sanders DS. Research: Provision of service and training for small bowel endoscopy in the UK. Frontline Gastroenterol. 2012;3:298-103.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 12]  [Cited by in F6Publishing: 16]  [Article Influence: 1.3]  [Reference Citation Analysis (0)]
40.  Höög CM, Bark LÅ, Arkani J, Gorsetman J, Broström O, Sjöqvist U. Capsule retentions and incomplete capsule endoscopy examinations: an analysis of 2300 examinations. Gastroenterol Res Pract. 2012;2012:518718.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 90]  [Cited by in F6Publishing: 108]  [Article Influence: 8.3]  [Reference Citation Analysis (0)]
41.  Goldstein JL, Eisen GM, Lewis B, Gralnek IM, Aisenberg J, Bhadra P, Berger MF. Small bowel mucosal injury is reduced in healthy subjects treated with celecoxib compared with ibuprofen plus omeprazole, as assessed by video capsule endoscopy. Aliment Pharmacol Ther. 2007;25:1211-1222.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 141]  [Cited by in F6Publishing: 114]  [Article Influence: 6.7]  [Reference Citation Analysis (0)]
42.  Hawkey CJ, Ell C, Simon B, Albert J, Keuchel M, McAlindon M, Fortun P, Schumann S, Bolten W, Shonde A. Less small-bowel injury with lumiracoxib compared with naproxen plus omeprazole. Clin Gastroenterol Hepatol. 2008;6:536-544.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 41]  [Cited by in F6Publishing: 46]  [Article Influence: 2.9]  [Reference Citation Analysis (0)]
43.  Smecuol E, Pinto Sanchez MI, Suarez A, Argonz JE, Sugai E, Vazquez H, Litwin N, Piazuelo E, Meddings JB, Bai JC. Low-dose aspirin affects the small bowel mucosa: results of a pilot study with a multidimensional assessment. Clin Gastroenterol Hepatol. 2009;7:524-529.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 83]  [Cited by in F6Publishing: 90]  [Article Influence: 6.0]  [Reference Citation Analysis (0)]
44.  Werlin SL, Benuri-Silbiger I, Kerem E, Adler SN, Goldin E, Zimmerman J, Malka N, Cohen L, Armoni S, Yatzkan-Israelit Y. Evidence of intestinal inflammation in patients with cystic fibrosis. J Pediatr Gastroenterol Nutr. 2010;51:304-308.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 123]  [Cited by in F6Publishing: 128]  [Article Influence: 9.1]  [Reference Citation Analysis (0)]
45.  Koulaouzidis A, Douglas S, Rogers MA, Arnott ID, Plevris JN. Fecal calprotectin: a selection tool for small bowel capsule endoscopy in suspected IBD with prior negative bi-directional endoscopy. Scand J Gastroenterol. 2011;46:561-566.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 62]  [Cited by in F6Publishing: 69]  [Article Influence: 5.3]  [Reference Citation Analysis (0)]
46.  Jensen MD, Kjeldsen J, Nathan T. Fecal calprotectin is equally sensitive in Crohn’s disease affecting the small bowel and colon. Scand J Gastroenterol. 2011;46:694-700.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 69]  [Cited by in F6Publishing: 75]  [Article Influence: 5.8]  [Reference Citation Analysis (0)]
47.  Koulaouzidis A, Douglas S, Plevris JN. Lewis score correlates more closely with fecal calprotectin than Capsule Endoscopy Crohn’s Disease Activity Index. Dig Dis Sci. 2012;57:987-993.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 66]  [Cited by in F6Publishing: 63]  [Article Influence: 5.3]  [Reference Citation Analysis (0)]
48.  Sipponen T, Haapamäki J, Savilahti E, Alfthan H, Hämäläinen E, Rautiainen H, Koskenpato J, Nuutinen H, Färkkilä M. Fecal calprotectin and S100A12 have low utility in prediction of small bowel Crohn’s disease detected by wireless capsule endoscopy. Scand J Gastroenterol. 2012;47:778-784.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 61]  [Cited by in F6Publishing: 65]  [Article Influence: 5.4]  [Reference Citation Analysis (0)]
49.  Khalife S, Soyer P, Alatawi A, Vahedi K, Hamzi L, Dray X, Placé V, Marteau P, Boudiaf M. Obscure gastrointestinal bleeding: preliminary comparison of 64-section CT enteroclysis with video capsule endoscopy. Eur Radiol. 2011;21:79-86.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 54]  [Cited by in F6Publishing: 46]  [Article Influence: 3.3]  [Reference Citation Analysis (0)]
50.  Postgate A, Despott E, Burling D, Gupta A, Phillips R, O’Beirne J, Patch D, Fraser C. Significant small-bowel lesions detected by alternative diagnostic modalities after negative capsule endoscopy. Gastrointest Endosc. 2008;68:1209-1214.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 111]  [Cited by in F6Publishing: 122]  [Article Influence: 7.6]  [Reference Citation Analysis (0)]
51.  Ross A, Mehdizadeh S, Tokar J, Leighton JA, Kamal A, Chen A, Schembre D, Chen G, Binmoeller K, Kozarek R. Double balloon enteroscopy detects small bowel mass lesions missed by capsule endoscopy. Dig Dis Sci. 2008;53:2140-2143.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 144]  [Cited by in F6Publishing: 135]  [Article Influence: 8.4]  [Reference Citation Analysis (0)]
52.  Chong AK, Chin BW, Meredith CG. Clinically significant small-bowel pathology identified by double-balloon enteroscopy but missed by capsule endoscopy. Gastrointest Endosc. 2006;64:445-449.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 96]  [Cited by in F6Publishing: 108]  [Article Influence: 6.0]  [Reference Citation Analysis (0)]
53.  Wijeratne R, Condon D. Ampulla of Vater Is Infrequently Visualized By Capsule Endoscopy. Gastrointest Endosc. 2006;63:AB172.  [PubMed]  [DOI]  [Cited in This Article: ]
54.  Kong H, Kim YS, Hyun JJ, Cho YJ, Keum B, Jeen YT, Lee HS, Chun HJ, Um SH, Lee SW. Limited ability of capsule endoscopy to detect normally positioned duodenal papilla. Gastrointest Endosc. 2006;64:538-541.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 33]  [Cited by in F6Publishing: 38]  [Article Influence: 2.1]  [Reference Citation Analysis (0)]
55.  Clarke JO, Giday SA, Magno P, Shin EJ, Buscaglia JM, Jagannath SB, Mullin GE. How good is capsule endoscopy for detection of periampullary lesions? Results of a tertiary-referral center. Gastrointest Endosc. 2008;68:267-272.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 42]  [Cited by in F6Publishing: 44]  [Article Influence: 2.8]  [Reference Citation Analysis (0)]
56.  Iaquinto G, Fornasarig M, Quaia M, Giardullo N, D’Onofrio V, Iaquinto S, Di Bella S, Cannizzaro R. Capsule endoscopy is useful and safe for small-bowel surveillance in familial adenomatous polyposis. Gastrointest Endosc. 2008;67:61-67.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 76]  [Cited by in F6Publishing: 71]  [Article Influence: 4.4]  [Reference Citation Analysis (0)]
57.  Metzger YC, Adler SN, Shitrit AB, Koslowsky B, Bjarnason I. Comparison of a new PillCam™ SB2 video capsule versus the standard PillCam™ SB for detection of small bowel disease. Reports in Medical Imaging. 2009;2:7-11.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 22]  [Cited by in F6Publishing: 23]  [Article Influence: 1.5]  [Reference Citation Analysis (0)]
58.  Katsinelos P, Kountouras J, Chatzimavroudis G, Zavos C, Pilpilidis I, Fasoulas K, Paroutoglou G. Wireless capsule endoscopy in detecting small-intestinal polyps in familial adenomatous polyposis. World J Gastroenterol. 2009;15:6075-6079.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 27]  [Cited by in F6Publishing: 22]  [Article Influence: 1.5]  [Reference Citation Analysis (0)]
59.  Nakamura M, Ohmiya N, Shirai O, Takenaka H, Kenji R, Ando T, Watanabe O, Kawashima H, Itoh A, Hirooka Y. Advance of video capsule endoscopy and the detection of anatomic landmarks. Hepatogastroenterology. 2009;56:1600-1605.  [PubMed]  [DOI]  [Cited in This Article: ]
60.  Karagiannis S, Dücker C, Dautel P, Strubenhoff J, Faiss S. Identification of the duodenal papilla by colon capsule endoscope. Z Gastroenterol. 2010;48:753-755.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 11]  [Cited by in F6Publishing: 10]  [Article Influence: 0.7]  [Reference Citation Analysis (0)]
61.  Lee HS, Lee KG, Kim J, Hyun JJ, Kim ES, Park SC, Park S, Keum B, Seo YS, Jeen YT. Comparison of PillCam SB and SB2 - Study of Normally Positioned Ampulla of Vater Detection. Gastrointest Endosc. 2010;71:AB370-371.  [PubMed]  [DOI]  [Cited in This Article: ]
62.  Selby WS, Prakoso E. The inability to visualize the ampulla of Vater is an inherent limitation of capsule endoscopy. Eur J Gastroenterol Hepatol. 2011;23:101-103.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 16]  [Cited by in F6Publishing: 17]  [Article Influence: 1.3]  [Reference Citation Analysis (0)]
63.  Koulaouzidis A, Douglas S, Plevris JN. Identification of the ampulla of Vater during oesophageal capsule endoscopy: two heads and viewing speed make a difference. Eur J Gastroenterol Hepatol. 2011;23:361; author reply 362.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 7]  [Cited by in F6Publishing: 8]  [Article Influence: 0.6]  [Reference Citation Analysis (0)]
64.  Park S, Chun HJ, Keum B, Seo YS, Kim YS, Jeen YT, Lee HS, Um SH, Kim CD, Ryu HS. Capsule Endoscopy to Detect Normally Positioned Duodenal Papilla: Performance Comparison of SB and SB2. Gastroenterol Res Pract. 2012;2012:202935.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 7]  [Cited by in F6Publishing: 9]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
65.  Koulaouzidis A, Plevris JN. Detection of the ampulla of Vater in small bowel capsule endoscopy: experience with two different systems. J Dig Dis. 2012;13:621-627.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 6]  [Cited by in F6Publishing: 10]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
66.  Friedrich K, Gehrke S, Sieg A. First clinical trial of a newly developed capsule endoscope with panoramic side view for small bowel. A pilot study. J Gastroenterol Hepatol. 2013;.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 37]  [Cited by in F6Publishing: 34]  [Article Influence: 3.1]  [Reference Citation Analysis (0)]
67.  Cuschieri JR, Osman MN, Wong RC, Chak A, Isenberg GA. Small bowel capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter defibrillators: Outcome analysis using telemetry review. World J Gastrointest Endosc. 2012;4:87-93.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 23]  [Cited by in F6Publishing: 19]  [Article Influence: 1.6]  [Reference Citation Analysis (0)]
68.  Bandorski D, Irnich W, Brück M, Beyer N, Kramer W, Jakobs R. Capsule endoscopy and cardiac pacemakers: investigation for possible interference. Endoscopy. 2008;40:36-39.  [PubMed]  [DOI]  [Cited in This Article: ]
69.  Yang XY, Chen CX, Zhang BL, Yang LP, Su HJ, Teng LS, Li YM. Diagnostic effect of capsule endoscopy in 31 cases of subacute small bowel obstruction. World J Gastroenterol. 2009;15:2401-2405.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 25]  [Cited by in F6Publishing: 26]  [Article Influence: 1.7]  [Reference Citation Analysis (0)]
70.  Cheon JH, Kim YS, Lee IS, Chang DK, Ryu JK, Lee KJ, Moon JS, Park CH, Kim JO, Shim KN. Can we predict spontaneous capsule passage after retention? A nationwide study to evaluate the incidence and clinical outcomes of capsule retention. Endoscopy. 2007;39:1046-1052.  [PubMed]  [DOI]  [Cited in This Article: ]
71.  Ordubadi P, Blaha B, Schmid A, Krampla W, Hinterberger W, Gschwantler M. Capsule endoscopy with retention of the capsule in a duodenal diverticulum. Endoscopy. 2008;40 Suppl 2:E247-E248.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 9]  [Cited by in F6Publishing: 10]  [Article Influence: 0.6]  [Reference Citation Analysis (0)]
72.  Schneider AR, Hoepffner N, Rösch W, Caspary WF. Aspiration of an M2A capsule. Endoscopy. 2003;35:713.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 31]  [Cited by in F6Publishing: 31]  [Article Influence: 1.5]  [Reference Citation Analysis (0)]
73.  Fleischer DE, Heigh RI, Nguyen CC, Leighton JA, Sharma VK, Musil D. Videocapsule impaction at the cricopharyngeus: a first report of this complication and its successful resolution. Gastrointest Endosc. 2003;57:427-428.  [PubMed]  [DOI]  [Cited in This Article: ]
74.  Sinn I, Neef B, Andus T. Aspiration of a capsule endoscope. Gastrointest Endosc. 2004;59:926-927.  [PubMed]  [DOI]  [Cited in This Article: ]
75.  Tabib S, Fuller C, Daniels J, Lo SK. Asymptomatic aspiration of a capsule endoscope. Gastrointest Endosc. 2004;60:845-848.  [PubMed]  [DOI]  [Cited in This Article: ]
76.  Buchkremer F, Herrmann T, Stremmel W. Mild respiratory distress after wireless capsule endoscopy. Gut. 2004;53:472.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 19]  [Cited by in F6Publishing: 17]  [Article Influence: 0.9]  [Reference Citation Analysis (0)]
77.  Rondonotti E, Herrerias JM, Pennazio M, Caunedo A, Mascarenhas-Saraiva M, de Franchis R. Complications, limitations, and failures of capsule endoscopy: a review of 733 cases. Gastrointest Endosc. 2005;62:712-716; quiz 752, 754.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 195]  [Cited by in F6Publishing: 181]  [Article Influence: 9.5]  [Reference Citation Analysis (0)]
78.  Nathan SR, Biernat L. Aspiration--an important complication of small-bowel video capsule endoscopy. Endoscopy. 2007;39 Suppl 1:E343.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 20]  [Cited by in F6Publishing: 21]  [Article Influence: 1.2]  [Reference Citation Analysis (0)]
79.  Shiff AD, Leighton JA, Heigh RI. Pulmonary aspiration of a capsule endoscope. Am J Gastroenterol. 2007;102:215-216.  [PubMed]  [DOI]  [Cited in This Article: ]
80.  Sepehr A, Albers GC, Armstrong WB. Aspiration of a capsule endoscope and description of a unique retrieval technique. Otolaryngol Head Neck Surg. 2007;137:965-966.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 13]  [Cited by in F6Publishing: 15]  [Article Influence: 0.9]  [Reference Citation Analysis (0)]
81.  Koulaouzidis A, Pendlebury J, Douglas S, Plevris JN. Aspiration of video capsule: rare but potentially life-threatening complication to include in your consent form. Am J Gastroenterol. 2009;104:1602-1603.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 11]  [Cited by in F6Publishing: 14]  [Article Influence: 0.9]  [Reference Citation Analysis (0)]
82.  Guy T, Jouneau S, D’Halluin PN, Lena H. Asymptomatic bronchial aspiration of a video capsule. Interact Cardiovasc Thorac Surg. 2009;8:568-570.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 11]  [Cited by in F6Publishing: 12]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
83.  Leeds JS, Chew TS, Sidhu R, Elliot CA, Sanders DS, McAlindon ME. Asymptomatic bronchial aspiration and retention of a capsule endoscope. Gastrointest Endosc. 2009;69:561-562.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 8]  [Cited by in F6Publishing: 10]  [Article Influence: 0.7]  [Reference Citation Analysis (0)]
84.  Bredenoord AJ, Stolk MF, Al-toma A. Unintentional video capsule bronchoscopy. Eur J Gastroenterol Hepatol. 2009;21:593.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 4]  [Cited by in F6Publishing: 4]  [Article Influence: 0.3]  [Reference Citation Analysis (0)]
85.  Choi HS, Kim JO, Kim HG, Lee TH, Kim WJ, Cho WY, Cho JY, Lee JS. A case of asymptomatic aspiration of a capsule endoscope with a successful resolution. Gut Liver. 2010;4:114-116.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 9]  [Cited by in F6Publishing: 10]  [Article Influence: 0.7]  [Reference Citation Analysis (0)]
86.  Depriest K, Wahla AS, Blair R, Fein B, Chin R. Capsule endoscopy removal through flexible bronchoscopy. Respiration. 2010;79:421-424.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 5]  [Cited by in F6Publishing: 6]  [Article Influence: 0.4]  [Reference Citation Analysis (0)]
87.  Kurtz LE, Devito B, Sultan K. Electronic image of the month. Small bowel video capsule aspiration with bronchoscopic-assisted extraction. Clin Gastroenterol Hepatol. 2010;8:e37-e38.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 1]  [Cited by in F6Publishing: 2]  [Article Influence: 0.1]  [Reference Citation Analysis (0)]
88.  Lucendo AJ, González-Castillo S, Fernández-Fuente M, De Rezende LC. Tracheal aspiration of a capsule endoscope: a new case report and literature compilation of an increasingly reported complication. Dig Dis Sci. 2011;56:2758-2762.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 21]  [Cited by in F6Publishing: 23]  [Article Influence: 1.8]  [Reference Citation Analysis (0)]
89.  Pezzoli A, Fusetti N, Carella A, Gullini S. Asymptomatic bronchial aspiration and prolonged retention of a capsule endoscope: a case report. J Med Case Rep. 2011;5:341.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 8]  [Cited by in F6Publishing: 10]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
90.  Parker C, Davison C, Panter S. Tracheal aspiration of a capsule endoscope: not always a benign event. Dig Dis Sci. 2012;57:1727-1728.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 10]  [Cited by in F6Publishing: 12]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
91.  Despott EJ, O’Rourke A, Anikin V, Davison C, Panter S, Bromley J, Plaice J, Corbett M, Fraser C. Tracheal aspiration of capsule endoscopes: detection, management, and susceptibility. Dig Dis Sci. 2012;57:1973-1974.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 6]  [Cited by in F6Publishing: 8]  [Article Influence: 0.7]  [Reference Citation Analysis (0)]
92.  Girdhar A, Usman F, Bajwa A. Aspiration of capsule endoscope and successful bronchoscopic extraction. J Bronchology Interv Pulmonol. 2012;19:328-331.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 8]  [Cited by in F6Publishing: 9]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
93.  Poudel A, Yarlagadda R, Lingutla D, Dytoc J, Fayyaz J, Das V, Khan A. Bronchial aspiration of a video capsule: A rare complication.  Available from: http: //www.unityhealthresidency.com/academic_national.asp.  [PubMed]  [DOI]  [Cited in This Article: ]
94.  Westerhof J, Koornstra JJ, Hoedemaker RA, Sluiter WJ, Kleibeuker JH, Weersma RK. Diagnostic yield of small bowel capsule endoscopy depends on the small bowel transit time. World J Gastroenterol. 2012;18:1502-1507.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 35]  [Cited by in F6Publishing: 36]  [Article Influence: 3.0]  [Reference Citation Analysis (0)]
95.  Lo SK. How Should We Do Capsule Reading? Tech Gastrointest Endosc. 2006;8:146-148.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 16]  [Cited by in F6Publishing: 18]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
96.  Gross SA, Schmelkin IJ, Kwak GS. Relationship of suspected blood indicator and blood transfusions in wireless capsule endoscopy. Am J Gastroenterol. 2003;98:S288.  [PubMed]  [DOI]  [Cited in This Article: ]
97.  Liangpunsakul S, Mays L, Rex DK. Performance of Given suspected blood indicator. Am J Gastroenterol. 2003;98:2676-2678.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 61]  [Cited by in F6Publishing: 63]  [Article Influence: 3.0]  [Reference Citation Analysis (0)]
98.  D’Halluin PN, Delvaux M, Lapalus MG, Sacher-Huvelin S, Ben Soussan E, Heyries L, Filoche B, Saurin JC, Gay G, Heresbach D. Does the “Suspected Blood Indicator” improve the detection of bleeding lesions by capsule endoscopy? Gastrointest Endosc. 2005;61:243-249.  [PubMed]  [DOI]  [Cited in This Article: ]
99.  Signorelli C, Villa F, Rondonotti E, Abbiati C, Beccari G, de Franchis R. Sensitivity and specificity of the suspected blood identification system in video capsule enteroscopy. Endoscopy. 2005;37:1170-1173.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 32]  [Cited by in F6Publishing: 35]  [Article Influence: 1.8]  [Reference Citation Analysis (0)]
100.  Ponferrada AD, Viso LM, Gonzalez CA, Cos Arregui E, Fernandez-Pacheco PM. Evaluation of Quickview® System and Suspected Blood Indicator® Test from of Given M2A Plus® Capsule Endoscopy Software in the Clinical Setting. Gastrointest Endosc. 2006;63:AB227.  [PubMed]  [DOI]  [Cited in This Article: ]
101.  Buscaglia JM, Giday SA, Kantsevoy SV, Clarke JO, Magno P, Yong E, Mullin GE. Performance characteristics of the suspected blood indicator feature in capsule endoscopy according to indication for study. Clin Gastroenterol Hepatol. 2008;6:298-301.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 64]  [Cited by in F6Publishing: 71]  [Article Influence: 4.4]  [Reference Citation Analysis (0)]
102.  Park SC, Chun HJ, Kim ES, Keum B, Seo YS, Kim YS, Jeen YT, Lee HS, Um SH, Kim CD. Sensitivity of the suspected blood indicator: an experimental study. World J Gastroenterol. 2012;18:4169-4174.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 30]  [Cited by in F6Publishing: 25]  [Article Influence: 2.1]  [Reference Citation Analysis (0)]
103.  Beejay NUA, Marcos D. Should we use the suspected blood indicator in wireless capsule endoscopy? A prospective analysis of 17689 frames from the Royal London Hospital. Gastrointest Endosc. 2009;69:AB199.  [PubMed]  [DOI]  [Cited in This Article: ]
104.  Schmelkin I. RAPID® 4 quickview v4 has 100% negative and positive predictive values. Boca Raton, FL: ICCE 2006; 89-90 Available from: http://icce.info/en-int/Documents/ICCE2006AbstractBook.pdf.  [PubMed]  [DOI]  [Cited in This Article: ]
105.  Appalaneni V, Glenn T, Hoffman BJ. Video capsule endoscopy: accuracy of QuickView. Gastrointest Endosc. 2007;65:AB313.  [PubMed]  [DOI]  [Cited in This Article: ]
106.  Westerhof J, Koornstra JJ, Weersma RK. Can we reduce capsule endoscopy reading times? Gastrointest Endosc. 2009;69:497-502.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 32]  [Cited by in F6Publishing: 39]  [Article Influence: 2.6]  [Reference Citation Analysis (0)]
107.  Shiotani A, Honda K, Kawakami M, Murao T, Matsumoto H, Tarumi K, Kusunoki H, Hata J, Haruma K. Evaluation of RAPID(®) 5 Access software for examination of capsule endoscopies and reading of the capsule by an endoscopy nurse. J Gastroenterol. 2011;46:138-142.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 19]  [Cited by in F6Publishing: 25]  [Article Influence: 1.9]  [Reference Citation Analysis (0)]
108.  Hosoe N, Rey JF, Imaeda H, Bessho R, Ichikawa R, Ida Y, Naganuma M, Kanai T, Hibi T, Ogata H. Evaluations of capsule endoscopy software in reducing the reading time and the rate of false negatives by inexperienced endoscopists. Clin Res Hepatol Gastroenterol. 2012;36:66-71.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 20]  [Cited by in F6Publishing: 28]  [Article Influence: 2.3]  [Reference Citation Analysis (0)]
109.  Saurin JC, Lapalus MG, Cholet F, D’Halluin PN, Filoche B, Gaudric M, Sacher-Huvelin S, Savalle C, Frederic M, Lamarre PA. Can we shorten the small-bowel capsule reading time with the “Quick-view” image detection system? Dig Liver Dis. 2012;44:477-481.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 37]  [Cited by in F6Publishing: 44]  [Article Influence: 3.7]  [Reference Citation Analysis (0)]
110.  Shiotani A, Honda K, Kawakami M, Kimura Y, Yamanaka Y, Fujita M, Matsumoto H, Tarumi K, Manabe N, Haruma K. Analysis of small-bowel capsule endoscopy reading by using Quickview mode: training assistants for reading may produce a high diagnostic yield and save time for physicians. J Clin Gastroenterol. 2012;46:e92-e95.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 30]  [Cited by in F6Publishing: 28]  [Article Influence: 2.3]  [Reference Citation Analysis (0)]
111.  Koulaouzidis A, Smirnidis A, Douglas S, Plevris JN. QuickView in small-bowel capsule endoscopy is useful in certain clinical settings, but QuickView with Blue Mode is of no additional benefit. Eur J Gastroenterol Hepatol. 2012;24:1099-1104.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 25]  [Cited by in F6Publishing: 31]  [Article Influence: 2.6]  [Reference Citation Analysis (0)]
112.  Kyriakos N, Karagiannis S, Galanis P, Liatsos C, Zouboulis-Vafiadis I, Georgiou E, Mavrogiannis C. Evaluation of four time-saving methods of reading capsule endoscopy videos. Eur J Gastroenterol Hepatol. 2012;24:1276-1280.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 8]  [Cited by in F6Publishing: 17]  [Article Influence: 1.4]  [Reference Citation Analysis (0)]
113.  Subramanian V, Mannath J, Telakis E, Ragunath K, Hawkey CJ. Efficacy of new playback functions at reducing small-bowel wireless capsule endoscopy reading times. Dig Dis Sci. 2012;57:1624-1628.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 13]  [Cited by in F6Publishing: 18]  [Article Influence: 1.5]  [Reference Citation Analysis (0)]
114.  Imagawa H, Oka S, Tanaka S, Noda I, Higashiyama M, Sanomura Y, Shishido T, Yoshida S, Chayama K. Improved visibility of lesions of the small intestine via capsule endoscopy with computed virtual chromoendoscopy. Gastrointest Endosc. 2011;73:299-306.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 55]  [Cited by in F6Publishing: 59]  [Article Influence: 4.5]  [Reference Citation Analysis (0)]
115.  Imagawa H, Oka S, Tanaka S, Noda I, Higashiyama M, Sanomura Y, Shishido T, Yoshida S, Chayama K. Improved detectability of small-bowel lesions via capsule endoscopy with computed virtual chromoendoscopy: a pilot study. Scand J Gastroenterol. 2011;46:1133-1137.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 32]  [Cited by in F6Publishing: 39]  [Article Influence: 3.0]  [Reference Citation Analysis (0)]
116.  Gupta T, Ibrahim M, Deviere J, Van Gossum A. Evaluation of Fujinon intelligent chromo endoscopy-assisted capsule endoscopy in patients with obscure gastroenterology bleeding. World J Gastroenterol. 2011;17:4590-4595.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in CrossRef: 21]  [Cited by in F6Publishing: 30]  [Article Influence: 2.3]  [Reference Citation Analysis (0)]
117.  Krystallis C, Koulaouzidis A, Douglas S, Plevris JN. Chromoendoscopy in small bowel capsule endoscopy: Blue mode or Fuji Intelligent Colour Enhancement? Dig Liver Dis. 2011;43:953-957.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 24]  [Cited by in F6Publishing: 33]  [Article Influence: 2.5]  [Reference Citation Analysis (0)]
118.  Duque G, Almeida N, Figueiredo P, Monsanto P, Lopes S, Freire P, Ferreira M, Carvalho R, Gouveia H, Sofia C. Virtual chromoendoscopy can be a useful software tool in capsule endoscopy. Rev Esp Enferm Dig. 2012;104:231-236.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in F6Publishing: 1]  [Reference Citation Analysis (0)]
119.  Nakamura M, Ohmiya N, Miyahara R, Ando T, Watanabe O, Kawashima H, Itoh A, Hirooka Y, Goto H. Usefulness of flexible spectral imaging color enhancement (FICE) for the detection of angiodysplasia in the preview of capsule endoscopy. Hepatogastroenterology. 2012;59:1474-1477.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in F6Publishing: 9]  [Reference Citation Analysis (0)]
120.  Sakai E, Endo H, Kato S, Matsuura T, Tomeno W, Taniguchi L, Uchiyama T, Hata Y, Yamada E, Ohkubo H. Capsule endoscopy with flexible spectral imaging color enhancement reduces the bile pigment effect and improves the detectability of small bowel lesions. BMC Gastroenterol. 2012;12:83.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 24]  [Cited by in F6Publishing: 28]  [Article Influence: 2.3]  [Reference Citation Analysis (0)]
121.  Spada C, Hassan C, Costamagna G. Virtual chromoendoscopy: will it play a role in capsule endoscopy? Dig Liver Dis. 2011;43:927-928.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 8]  [Cited by in F6Publishing: 11]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
122.  Aihara H, Ikeda K, Tajiri H. Image-enhanced capsule endoscopy based on the diagnosis of vascularity when using a new type of capsule. Gastrointest Endosc. 2011;73:1274-1279.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 8]  [Cited by in F6Publishing: 11]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
123.  Kusuda Y. A further step beyond wireless capsule endoscopy. Sens Rev. 2005;25:259-260.  [PubMed]  [DOI]  [Cited in This Article: ]
124.  Johannessen EA, Wang L, Cui L, Tang TB, Ahmadian M, Astaras A, Reid SW, Yam PS, Murray AF, Flynn BW. Implementation of multichannel sensors for remote biomedical measurements in a microsystems format. IEEE Trans Biomed Eng. 2004;51:525-535.  [PubMed]  [DOI]  [Cited in This Article: ]
125.  Karagozler ME, Cheung E, Kwon J, Sitti M.  Miniature Endoscopic Capsule Robot using Biomimetic Micro-Patterned Adhesives. 2006;Institute of Electrical and Electronics Engineers, 2006: 105-111.  [PubMed]  [DOI]  [Cited in This Article: ]
126.  Quirini M, Scapellato S, Valdastri P, Menciassi A, Dario P. An approach to capsular endoscopy with active motion. Conf Proc IEEE Eng Med Biol Soc. 2007;2007:2827-2830.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 17]  [Cited by in F6Publishing: 10]  [Article Influence: 0.6]  [Reference Citation Analysis (0)]
127.  Valdastri P, Quaglia C, Susilo E, Menciassi A, Dario P, Ho CN, Anhoeck G, Schurr MO. Wireless therapeutic endoscopic capsule: in vivo experiment. Endoscopy. 2008;40:979-982.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 77]  [Cited by in F6Publishing: 53]  [Article Influence: 3.3]  [Reference Citation Analysis (0)]
128.  Glass P, Cheung E, Sitti M. A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives. IEEE Trans Biomed Eng. 2008;55:2759-2767.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 126]  [Cited by in F6Publishing: 77]  [Article Influence: 5.1]  [Reference Citation Analysis (0)]
129.  Valdastri P, Webster III RJ, Quaglia C, Quirini M, Menciassi A, Dario P. A New Mechanism for Meso-Scale Legged Locomotion in Compliant Tubular Environments. IEEE T Robot. 2009;25:1047-1057.  [PubMed]  [DOI]  [Cited in This Article: ]
130.  Tortora G, Valdastri P, Susilo E, Menciassi A, Dario P, Rieber F, Schurr MO. Propeller-based wireless device for active capsular endoscopy in the gastric district. Minim Invasive Ther Allied Technol. 2009;18:280-290.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 83]  [Cited by in F6Publishing: 52]  [Article Influence: 3.7]  [Reference Citation Analysis (0)]
131.  Valdastri P, Quaglia C, Buselli E, Arezzo A, Di Lorenzo N, Morino M, Menciassi A, Dario P. A magnetic internal mechanism for precise orientation of the camera in wireless endoluminal applications. Endoscopy. 2010;42:481-486.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 43]  [Cited by in F6Publishing: 48]  [Article Influence: 3.4]  [Reference Citation Analysis (0)]
132.  Ciuti G, Valdastri P, Menciassi A, Dario P. Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal procedures. Robotica. 2010;28:199-207.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 203]  [Cited by in F6Publishing: 105]  [Article Influence: 7.0]  [Reference Citation Analysis (0)]
133.  Bourbakis N, Giakos G, Karargyris A.  Design of new-generation robotic capsules for therapeutic and diagnostic endoscopy. 2010;Institute of Electrical and Electronics Engineers, 2010: 1-6.  [PubMed]  [DOI]  [Cited in This Article: ]
134.  Gao M, Hu C, Chen Z, Zhang H, Liu S. Design and fabrication of a magnetic propulsion system for self-propelled capsule endoscope. IEEE Trans Biomed Eng. 2010;57:2891-2902.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 75]  [Cited by in F6Publishing: 79]  [Article Influence: 5.6]  [Reference Citation Analysis (0)]
135.  Simi M, Valdastri P, Quaglia C, Menciassi A, DarioP . Design, fabrication, and testing of a capsule with hybrid locomotion for gastrointestinal tract exploration. IEEE-ASME T Mech. 2010;15:170-180.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 121]  [Cited by in F6Publishing: 48]  [Article Influence: 3.4]  [Reference Citation Analysis (0)]
136.  Morita E, Ohtsuka N, Shindo Y, Nouda S, Kuramoto T, Inoue T, Murano M, Umegaki E, Higuchi K. In vivo trial of a driving system for a self-propelling capsule endoscope using a magnetic field (with video). Gastrointest Endosc. 2010;72:836-840.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 52]  [Cited by in F6Publishing: 54]  [Article Influence: 3.9]  [Reference Citation Analysis (0)]
137.  Yang S, Park K, Kim J, Kim TS, Cho IJ, Yoon ES. Autonomous locomotion of capsule endoscope in gastrointestinal tract. Conf Proc IEEE Eng Med Biol Soc. 2011;2011:6659-6663.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 6]  [Cited by in F6Publishing: 10]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
138.  Filip D, Eggermont M, Nagel J, Andrews CN.  Electronic Stool (e-Stool): A Novel Self-Stabilizing Video Capsule Endoscope for Reliable Non-Invasive Colonic Imaging. In: Proceedings of the ASME 2011; ASME, 2011: 711-722.  [PubMed]  [DOI]  [Cited in This Article: ]
139.  Yim S, Sitti M. Design and rolling locomotion of a magnetically actuated soft capsule endoscope. IEEE T Robot. 2012;28:183-194.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 237]  [Cited by in F6Publishing: 238]  [Article Influence: 19.8]  [Reference Citation Analysis (0)]
140.  Kong K, Yim S, Choi S, Jeon D. A Robotic Biopsy Device for Capsule Endoscopy. J Med Devices. 2012;6.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 49]  [Cited by in F6Publishing: 50]  [Article Influence: 4.2]  [Reference Citation Analysis (0)]
141.  Woods SP, Constandinou TG. Wireless capsule endoscope for targeted drug delivery: mechanics and design considerations. IEEE Trans Biomed Eng. 2013;60:945-953.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 119]  [Cited by in F6Publishing: 71]  [Article Influence: 5.9]  [Reference Citation Analysis (0)]
142.  Basar MR, Malek F, Juni KM, Shaharom Idris M, Iskandar M. Saleh M. Ingestible Wireless Capsule Technology: A Review of Development and Future Indication. Int J Antenn Propag. 2012;2012.  [PubMed]  [DOI]  [Cited in This Article: ]
143.  Song HJ, Moon JS, Do JH, Cha IH, Yang CH, Choi MG, Jeen YT, Kim HJ. Korean Gut Image Study Group. Guidelines for Bowel Preparation before Video Capsule Endoscopy. Clin Endosc. 2013;46:147-154.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 32]  [Cited by in F6Publishing: 38]  [Article Influence: 3.5]  [Reference Citation Analysis (0)]
144.  Koulaouzidis A, Giannakou A, Yung DE, Dabos KJ, Plevris JN. Do prokinetics influence the completion rate in small-bowel capsule endoscopy? - A systematic review and meta-Analysis. Curr Med Res Opin. 2013;Jun 21.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 53]  [Cited by in F6Publishing: 61]  [Article Influence: 5.5]  [Reference Citation Analysis (0)]