Clinical Research Open Access
Copyright ©2006 Baishideng Publishing Group Co., Limited. All rights reserved.
World J Gastroenterol. Feb 28, 2006; 12(8): 1243-1248
Published online Feb 28, 2006. doi: 10.3748/wjg.v12.i8.1243
Short- and medium-term reproducibility of gastric emptying of a solid meal determined by a low dose of 13C-octanoic acid and nondispersive isotope-selective infrared spectrometry
Anna Kasicka-Jonderko, Magdalena Kamińska, Krzysztof Jonderko, Olga Setera, Barbara Błońska-Fajfrowska, Department of Basic Biomedical Science, School of Pharmacy, Medical University of Silesia, Sosnowiec, Poland
Krzysztof Jonderko, Department of Physiology, Institute of Occupational Medicine and Environmental Health, Sosnowiec, Poland
Author contributions: All authors contributed equally to the work.
Supported by a research grant (3 P05D 054 24) from the Ministry of Scientific Research and Information Technology (formerly: State Committee For Scientific Research) of the Republic of Poland - contract # 0617/P05/2003/24
Correspondence to: Dr. Anna Kasicka-Jonderko, MD, Department of Basic Biomedical Science, School of Pharmacy, Medical University of Silesia, 3 Kasztanowa street, PL-41-205 Sosnowiec, Poland. akj@slam.katowice.pl
Telephone: +48-32-2919272 Fax: +48-32-2945548
Received: April 18, 2005
Revised: July 12, 2005
Accepted: July 20, 2005
Published online: February 28, 2006

Abstract

AIM: To evaluate the reproducibility of a modified 13C breath test-based measurement of solid phase gastric emptying (GE) within the frames of a simple-repeated measure study protocol.

METHODS: Twelve healthy subjects (6 females and 6 males, mean age 24.9 ± 0.7 years) were recruited to undergo three identical GE examinations. In six subjects the first two examinations were performed 2 d apart, and the third session was carried out at a median interval of 19.5 d (range 18 - 20 d) from the second one. In another six subjects the first two measurements were taken 20 d apart (median, range: 17-23 d), whereas the third session took place 2 d after the second one. Probes of expiratory air collected before and during six hours after intake of a solid meal (378 kcal) labelled with 75 μL (68 mg) 13C-octanoic acid, were measured for 13CO2 enrichment with the nondispersive isotope-selective infrared spectrometry NDIRS apparatus.

RESULTS: Taking coefficients of variation for paired examinations into account, the short-term reproducibility of the GE measurement was slightly but not significantly better than the medium-term one: 7.7% and 11.2% for the lag phase (T-Lag), 7.3% and 10.9% for the gastric half emptying time (T½). The least differences in GE parameters detectable at P = 0.05 level in the 12 paired examinations were 9.6 and 15.6 min for T-Lag, 11.6 and 19.7 min for T½ by a two-day or two to three-week time gap, respectively.

CONCLUSION: The low-cost modification of the breath test involving a lower dose of 13C-octanoic acid and NDIRS, renders good short- and medium-term reproducibility, as well as sensitivity of the measurement of gastric emptying of solids.

Key Words: 13C breath test, Gastric emptying, Nondispersive isotope-selective infrared spectrometry, 13C-octanoic acid, Reproducibility



INTRODUCTION

Since its first description and validation in 1993[1], 13C-octanoic acid breath test (13C-OABT) has dug its way towards the top of the list of the most widely used methods for the measurement of gastric emptying of solids. For example, recently published epidemiologically-oriented studies addressing the features of gastric emptying kinetics in large cohorts of patients involving hundreds of subjects suffering from functional dyspepsia, have been performed with 13C-OABT[2-4]. Also the introduction of less expensive and technically demanding apparatus, based on the non-dispersive isotope-selective infrared spectrometry (NDIRS), is an undeniable milestone which has opened the gate for a widespread use of 13C breath tests[5-7], the 13C-OABT making no exception in this respect[8-13].

Reproducibility is a vital feature of any measurement or diagnostic method used in medical practice. Few data are available on the repeatability of the 13C-OABT in humans, and reports addressing this subject appear unsatisfactory[14,18]. Moreover, no previous study has reported reproducibility of the NDIRS variety of the 13C-OABT. The aim of this study was to establish the short- and medium-term reproducibility of the 13C-OABT with NDIRS and a reduced dose of the 13C substrate.

MATERIALS AND METHODS
Subjects

Twelve healthy subjects (6 females and 6 males) were recruited to participate in this study, their mean age was 24.9 ± 0.7 years, and the average body mass index amounted to 22.37 ± 1.06 kg/m2.

During a screening interview, the participants declared themselves to be in full health according to the World Health Organisation criteria. Exclusion criteria comprised a history of surgery affecting the digestive tract anatomy with the exception of appendectomy, current use of any drugs which might affect gastrointestinal motility, and pregnancy. The recruitment procedure involved performance of a standard breath test with 13C-urea, so that exclusively subjects with a negative test result for Helicobacter pylori infection were admitted. Except for three persons, all the participants were non-smokers. The study was conducted in accordance with the Helsinki Declaration, and each volunteer gave a written consent after getting information as to the aim, protocol and methodology of the study. During the introductory interview, the subjects were committed not to eat any food of naturally increased 13C content, such as products made of maize, cane sugar, pineapple, kiwi fruit for 48 h preceding the examination.

Experimental protocol

Each subject underwent three sessions of gastric emptying measurement held on separate days. In six subjects the first two examinations were performed 2 d apart, and the third session was carried out at a median interval of 19.5 d (range 18-20 d) from the second one. In another six subjects, the first two gastric emptying measurements were taken 20 d apart (median, range 17-23 d), whereas the third session took place 2 d after the second one. The assignment of the order of intervals separating the sessions (short-long or long-short) was randomized. Ultimately the short-term reproducibility assessment involved performance of 12 pairs of gastric emptying examinations separated by a two-day break, whereas twelve pairs of examinations accomplished at a median interval of 21.5 d (range 17-23 d) were dedicated for the evaluation of the medium-term reproducibility.

The research was performed on volunteers who reported themselves to the laboratory in the morning, after a 12-h overnight fasting and abstaining from cigarette smoking (if applicable). At the beginning, a basal fasted probe of the exhaled air was put into an aluminium-covered plastic bag of about 1 L capacity (Fisher Analysen Instrumente GmbH, Germany). At the time point of “0”, the subjects were given a solid test meal, a pancake made of two eggs, 30 g wheat flour and 0.1 g baking powder, which was additionally smeared with 50 g of strawberry jam before serving. The total energy content of the meal was 1574 kJ (378 kcal) and it contained 15.5 g proteins, 16.8 g fat, and 43.0 g carbohydrates. During the preparation procedure of the pancake, the two-egg yolks were temporarily separated from the egg whites and thoroughly mixed with 75 μL (68 mg) of 13C-octanoic acid (INC610P, lot #T012A-L3241, Euriso-Top, France) which was instilled with a precision digital micropipette (Calibra 822-20/200, Socorex, Switzerland). Thereafter the yolks were added to and stirred with the remaining ingredients with an electric mixer. Finally the dough was transferred into a pan and fried to firm consistency with addition of 5 mL of sunflower oil. The time needed to consume the test meal did not exceed 10 min. No drink was served with the meal because the study intended to assess strictly the reproducibility of the solid phase gastric emptying.

Reckoning the passage of time from the defined “0” point, 26 probes of the expiratory air were collected postprandially every 10 min during the first hour, and then every 15 min for an additional 5 h. After ingestion of the meal, the subjects were asked not to take any additional food or drink for 6 h. They were enabled to rest sitting in a comfortably furnished room and allowed to watch video films.

Measurement of 13CO2 and derivation of gastric emptying parameters

Concentrations of 13CO2 in the probes of the exhaled air were measured with the NDIRS apparatus (IRIS, Wagner Analysen Technik Vertriebs GmbH, Germany; a model equipped with 16 ports for simultaneous mounting of bags with air samples was used). Repeatability of the 13CO2 measurement with the NDIRS technique was checked by double measurements performed on 96 probes of the exhaled air originating from 3 randomly selected gastric emptying examinations. The procedure was performed in such a way that the second measurement was taken instantly without removing the bags containing the probes from the apparatus.

The determined 13CO2 content within the total pool of the exhaled CO2 was expressed in δ‰ PDB units, i.e. relative to the international standard - the calcium carbonate of the fossil Belemnitella of the cretaceous Pee Dee formation in South Carolina, USA (zero δ‰ PDB corresponds to 1.12372% 13C atoms within CaCO3). The obtained δ‰ PDB data were exported to an ASCII file for a subsequent analysis with a user-created Excel spreadsheet.

The changes in 13CO2 concentration were recalculated to net increments expressed in ‰ DOB (delta over baseline) units according to the formula:

DOBi = δ PDBi-δ PDB0

where i stands for the probe number, and the 0 index pertains to the basal probe of the expiratory air.

The momentary 13C recovery at time i, D%i_13C, expressed in percent age of administered dose per hour (% dose per hour), was computed according to the equation:

D%i_13C = 100 . (DOBi/1000 . 0.0112372 . TCO2) / dose

where TCO2 = total expiratory CO2 production in mmol/h and dose = amount in mmol of 13C-octanoic acid given to the subjects. The TCO2 was derived by multiplication by the rate of 300 mmol/m2 per hour by the body surface area computed according to the formula by Haycock et al[19].

The 13C recovery within a given period, Ci_13C, expressed in percent age of dose, was computed following the trapezoid rule:

Ci_13C = 0.5 . (DOBi-1 + DOBi)/1000 . △t . 0.0112372 . TCO2 / dose

where △t = the time span between consecutive DOB measurements

The cumulative 13C recovery Ti -13C in percent age of administered dose was then derived from a stepwise summation of Ci_13C for i within the domain of 1 - 26.

Using algorithms of non-linear regression implemented in the Statistica 6.1 software[20], the curves of momentary 13C recovery were fitted to the function:

D%i_13C = atbe-ct

where t stands for time, and a, b, c are parameters of the function

which enables computation of three gastric emptying parameters[1,21]: the lag phase, T-Lag = b/c; the gastric half emptying time, T½ = Gamma inv. (0.5; b+1; 1/c); and the gastric emptying coefficient, GEC = ln(a)

Statistical analysis

A null hypothesis, assuming a zero difference between repeated measurements, was checked with the paired Student’s t test. The reproducibility of the gastric emptying parameters was expressed in terms of the coefficient of variation for paired examinations, CVp[22,23]. Moreover Bland and Altman statistics was applied in order to calculate the repeatability coefficient, RC[24,25]. Finally, △0.05 - the least statistically significant difference detectable at P=0.05 level (two-tailed) was calculated for each gastric emptying parameter[26]. Results were presented as mean ± SE. All statistical analyses were performed with the Statistica 6.1 software, licence # adbp409a903816ar[20].

RESULTS
Repeatability of NDIRS measurement of 13CO2 enrichment in exhaled air

Bland and Altman statistics performed on the paired measurements of the 13CO2 content within 96 samples of the expiratory air yielded a repeatability coefficient of 0.40‰, and the mean difference between the repeated measurements amounted to 0.07‰ (95% confidence interval: 0.34 - 0.46‰) (Figure 1). If the data pertaining to the 13CO2 content within the expiratory air were expressed in terms of the delta over baseline values, the respective repeatability coefficient amounted to 0.62‰, with a mean difference of 0.28‰ between repeated measurements (95% confidence interval: 0.34 - 0.90‰).

Figure 1
Figure 1 Repeatability of the measurement of 13CO2 enrichment (d) in expiratory air after intake of a solid meal labeled with 75 mL (68 mg) 13C-octanoic acid. Ninety-six pairs of d measurements taken from three randomly selected examinations were considered.
Reproducibility of parameters characterizing gastric emptying kinetics

Ingestion of the solid test meal labeled with 75 μL of 13C-octanoic acid brought about an expected increase of the 13CO2 concentration in the exhaled air (Figure 2). The maximum net increment in the 13CO2 concentration amounted to 9.1‰ (mean, 95% confidence intervals 5.3‰ to 12.9‰) during the 36 gastric emptying examinations. The maximum momentary 13C recovery in the exhaled air was observed at 165 min (mean, 95% confidence intervals 112 min to 219 min) postprandially, and amounted on average to 11.50 ± 0.36 % dose per hour (Figure 3). During the whole 6 h observation period 41.80 ± 1.13 % of the administered tracer was eliminated in the form of 13CO2 within the expiratory air (Figure 3).

Figure 2
Figure 2 Individual curves reflecting the increment in 13CO2 enrichment in exhaled air after intake of a 378 kcal solid meal containing 75 mL (68 mg) 13C-octanoic acid (the 36 curves were obtained in 12 healthy subjects at three separate days).
Figure 3
Figure 3 Momentary (empty squares) and cumulative (filled squares) 13C recovery in exhaled air after ingestion of a 378 kcal solid meal containing 75 mL (68 mg) 13C-octanoic acid. The data are grand means with standard errors (bars) calculated on average values obtained in 12 healthy volunteers during three examinations carried out on separate days.

A graphical depiction of the Bland and Altman statistics pertaining to the gastric emptying parameters is given in Figure 4, and a comprehensive statistical description of the reproducibility data is provided in Table 1. In no instance the null hypothesis of a zero difference between the repeated measurements had to be discarded. According to the data assembled in Table I, greater values of RC and CVp characterized the medium-term compared to the short-term reproducibility. A comparison of the absolute values of the differences between the paired measurements implied rejection of a hypothesis that reproducibility of the gastric emptying was significantly worse when the examinations were separated by an extended time gap.

Table 1 Reproducibility of solid gastric emptying measurement with breath test at a 68 mg (75 μL) dose of 13C-Octanoic acid and isotope-selective nondispersive infrared spectrometry.
Observed values1T-Lag,lag phase149.7 ± 4.6 min
T½,gastric half emptying time195.6 ± 4.2 min
GEC,gastric emptying coefficient2.56 ± 0.09
Short-termMedium-termShort-termMedium-termShort-termMedium-term
RC (min)31.646.739.159.10.610.87
CVp (%)7.711.27.310.98.312.5
△0.05 (min)9.615.611.619.70.170.29
Figure 4
Figure 4 Bland and Altman statistics (plot of differences between pairs vs their names) of the short-(open symbols) and medium-term( filled symbols) reproducibility of the measurement of the lag phase (T-Lag, panel A), the gastric half emptying time (T½ , panel B), and the gastric emptying coefficient (GEC, panel C) of the solid phase gastric emptying with a breath test using 75 mL (68 mg) 13C-octanoic acid and the isotope-selective nondispersive infrared spectrometry. On each panel the respective borders of the 95% confidence intervals are plotted - cf. the legend of the GEC graph, panel C.
DISCUSSION

The novelty of the results furnished by the current study consists in: for the first time the reproducibility of the 13C-OABT was evaluated with the NDIRS, a reduced dose of the 13C-octanoic acid was applied for the test, the test meal was administered without allowance of any intake of liquids so that pure repeatability of the solid phase gastric emptying could be discerned, and a distinguishment was made between the short- and medium-term reproducibility.

Typically the 13C-OABT is performed with 100 μL of 13C-octanoic acid which is equivalent to 91 mg[2-5,8-12,14,16-18]. It was reported that a lower dose - 50 mg 13C-octanoic acid can be used to examine the solid phase gastric emptying[21]. The NDIRS apparatus coped well with the 68 mg (75 μL) amount of 13C-octanoic acid applied for labelling the test meal in the current study. This contention is supported by the finding of a low value of the repeatability coefficient (0.40‰) and a narrow 95% confidence interval of the differences between paired measurements of 13CO2 enrichment (0.34 - 0.46‰) derived from a large number of breath samples covering a typical range of 13CO2 concentration encountered throughout the 6 h of the 13C-OABT. Since baseline fluctuation of 13CO2 concentration in breath is expected to approach a standard deviation of 0.72‰[27], our results clearly indicate that the measurement error involved in the NDIRS technique is less than the natural baseline fluctuation of 13CO2 concentration in breath. The finding quoted is in concordance with our previously published results[6,7,28].

While performing the 13C-OABT, we generously allowed for a frequent sampling of the expiratory air (a total of 27 samples were collected throughout a single examination including the basal specimen) over a long observation period of 6 h. This approach was substantiated by findings of other authors clearly stating that too short a collection period and/or an infrequent sampling of the expiratory air may lead to erroneous estimation of the parameters of gastric emptying with the 13C-OABT[16,17,29]. According to Choi et al[16,17], duration of the 13C-OABT obligatory should be extended to six hours, since largely overestimated values of T_Lag and T½ would be derived from the data truncated to four hours.

Three parameters are originally proposed as quantitative descriptors of the gastric emptying kinetics examined with the 13C-OABT, namely: T_Lag, T½, and GEC[1,21]. Nowadays researchers are increasingly inclined to use the T½ only when reporting on their results with the 13C-OABT. This apparently minimalistic approach has quite firm grounds. The shortcomings of GEC consist in the fact that its estimation is not independent of the endogenous CO2 production, and in the case of fast gastric evacuation patterns this parameter may underestimate gastric emptying[1]. T_Lag of the 13C-OABT is originally conceived to reflect the duration of the first phase of gastric evacuation, while the solid meal is ground to particles of 1-2 mm in diameter before the actual emptying can start. This assumption has not found any convincing corroboration in validation studies of the 13C-OABT against the scintigraphic determination of gastric emptying, which is the so called ‘golden standard’ in the field of gastro-emptology[16,17]. Quite recently it was even demonstrated by Doppler ultrasonography that transpyloric flow starts already during ingestion of a 13C-labelled solid meal, which results in a detectable excretion of 13CO2[30]. It has been shown that trituration of the solid meal can lead to a pronounced shortening of this parameter[31]. Nevertheless, T_Lag will be more and more willingly replaced by the term ‘time to reach the maximum of the momentary 13CO2 excretion’ which is the revised representation of what the T-Lag derived mathematically from the function fitted to a 13CO2 excretion curve actually is[1,8,9,21].

In the present study, we controlled rigorously and kept constant a number of factors which might affect reproducibility of the 13C-OABT, namely meal composition, time of the day when the gastric emptying measurement was taken, posture of the subjects during the test. Ingestion of the test meal took place irrespective of actual phase of the duodenal migrating motor complex (MMC), because monitoring of the duodenal motor activity would require insertion of a manometric tube into the lumen of the duodenum - an invasive manoeuvre which might interfere with physiological conditions assumed for the 13C-OABT performance; observation of a particular phase of the duodenal MMC could not ameliorate the reproducibility of the scintigraphic measurement of the gastric empting of the solid phase of a meal[32]. Homogeneity was the important feature of the test meal we applied, that is the pancake was uniformly labelled with 13C-octanoic acid and eaten without addition of any liquid to assure the sole assessment of the reproducibility of the solid phase gastric emptying [33].

Because there are no other reports on the 13C-OABT performed with the NDIRS, our data can be compared only to the results obtained by other authors applying the isotope ratio mass spectrometry (IRMS). Choi et al[17] reported that the reproducibility of T-Lag and T½ is 14% and 15% respectively. In the study by Delbende et al[18] the pertinent RC and CVp amounted to 35.5 min and 14.3%, respectively. The reproducibility results of those two studies look very much alike indeed. The results of the present study indicated that the reproducibility of gastric emptying of solids determined by 13C-OABT and the NDIRS was not worse than that by IRMS. Moreover, both the reproducibility and sensitivity (as assessed by the magnitude of the least detectable differences in the gastric emptying parameters) were preserved when the examinations were separated by a two- three-week time gap. Finally, it should be emphasized that the results obtained by others[17,18] and coming from our current study clearly demonstrate that the reproducibility of the measurement of gastric emptying of solids by the 13C-OABT is equivalent to the intra-subject variability of the solid-phase gastric emptying observed with gamma scintigraphy[22,23]. This is an important finding due to the inherently indirect nature of 13C-OABT. The reproducibility of 13C-OABT would be affected by more factors than a scintigraphic GE measurement, namely the intestinal absorption of the 13C-octanoic acid, its oxidation to 13CO2 within the liver, as well as kinetics of the subsequent transfer of 13CO2 to the expiratory air.

In conclusion, the low-cost modification of the breath test involving a lower dose of 13C-octanoic acid and NDIRS, renders a good short- and medium-term reproducibility, as well as sensitivity of the measurement of gastric emptying of a solid meal.

Footnotes

S- Editor Guo SY L- Editor Wang XL E- Editor Bai SH

References
1.  Ghoos YF, Maes BD, Geypens BJ, Mys G, Hiele MI, Rutgeerts PJ, Vantrappen G. Measurement of gastric emptying rate of solids by means of a carbon-labeled octanoic acid breath test. Gastroenterology. 1993;104:1640-1647.  [PubMed]  [DOI]  [Cited in This Article: ]
2.  Haag S, Talley NJ, Holtmann G. Symptom patterns in functional dyspepsia and irritable bowel syndrome: relationship to disturbances in gastric emptying and response to a nutrient challenge in consulters and non-consulters. Gut. 2004;53:1445-1451.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 53]  [Cited by in F6Publishing: 33]  [Article Influence: 1.7]  [Reference Citation Analysis (0)]
3.  Corsetti M, Caenepeel P, Fischler B, Janssens J, Tack J. Impact of coexisting irritable bowel syndrome on symptoms and pathophysiological mechanisms in functional dyspepsia. Am J Gastroenterol. 2004;99:1152-1159.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 119]  [Cited by in F6Publishing: 115]  [Article Influence: 5.8]  [Reference Citation Analysis (0)]
4.  Talley NJ, Verlinden M, Jones M. Can symptoms discriminate among those with delayed or normal gastric emptying in dysmotility-like dyspepsia. Am J Gastroenterol. 2001;96:1422-1428.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 131]  [Cited by in F6Publishing: 128]  [Article Influence: 5.6]  [Reference Citation Analysis (0)]
5.  Schadewaldt P, Schommartz B, Wienrich G, Brösicke H, Piolot R, Ziegler D. Application of isotope-selective nondispersive infrared spectrometry (IRIS) for evaluation of [13C]octanoic acid gastric-emptying breath tests: comparison with isotope ratio-mass spectrometry (IRMS). Clin Chem. 1997;43:518-522.  [PubMed]  [DOI]  [Cited in This Article: ]
6.  Jonderko K, Kasicka-Jonderko A, Syrkiewicz-Trepiak D, Błońska-Fajfrowska B. Feasibility of a breath test with a substrate of natural 13C-abundance and isotope-selective non-dispersive infrared spectrometry: a preliminary study. J Gastroenterol Hepatol. 2005;20:1228-1234.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 13]  [Cited by in F6Publishing: 12]  [Article Influence: 0.6]  [Reference Citation Analysis (0)]
7.  Kasicka-Jonderko A, Szymszal M, Jonderko K, Piekarska A, B ońska-Fajfrowska B. Reproducibility of liquid gastric emptying measurement with the use of an ultra low dose of 13C-Sodium acetate and isotope-selective nondispersive infrared spectrometry. Ann Acad Med Sil. 2005;59:144-152.  [PubMed]  [DOI]  [Cited in This Article: ]
8.  Toepfer M, Folwaczny C, Lochmüller H, Schroeder M, Riepl RL, Pongratz D, Müller-Felber W. Noninvasive 13C-octanoic acid breath test shows delayed gastric emptying in patients with amyotrophic lateral sclerosis. Digestion. 1999;60:567-571.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 32]  [Cited by in F6Publishing: 30]  [Article Influence: 1.2]  [Reference Citation Analysis (0)]
9.  Peracchi M, Gebbia C, Ogliari C, Fraquelli M, Viganò R, Baldassarri A, Bianchi PA, Conte D. Influence of caloric intake on gastric emptying of solids assessed by 13C-octanoic acid breath test. Scand J Gastroenterol. 2000;35:814-818.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 26]  [Cited by in F6Publishing: 27]  [Article Influence: 1.1]  [Reference Citation Analysis (0)]
10.  Cappello G, Malatesta MG, Ferri A, Ciccaglione AF, Toracchio S, Grossi L, Marzio L. Gastric emptying of a solid-liquid meal measured with 13C octanoic acid breath test and real-time ultrasonography: a comparative study. Am J Gastroenterol. 2000;95:3097-3100.  [PubMed]  [DOI]  [Cited in This Article: ]
11.  Chen CP, Chen CY, Lu CL, Chang FY, Lee SD, Chu LS, Liu RS, Wu HC. Infrared spectrometry based 13C-octanoic acid breath test in measuring human solid gastric emptying. J Gastroenterol Hepatol. 2003;18:41-46.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 21]  [Cited by in F6Publishing: 21]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
12.  Le Blanc-Louvry I, Savoye G, Maillot C, Denis P, Ducrotté P. An impaired accommodation of the proximal stomach to a meal is associated with symptoms after distal gastrectomy. Am J Gastroenterol. 2003;98:2642-2647.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 19]  [Cited by in F6Publishing: 20]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
13.  Yamamoto T, Ishii T, Sanaka M, Osanai Y, Kawakami T, Anjiki H, Hattori K, Saitoh M, Kuyama Y. Modified 13C-octanoate breath test and impact of sampling points. J Clin Gastroenterol. 2004;38:669-670.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 8]  [Cited by in F6Publishing: 7]  [Article Influence: 0.4]  [Reference Citation Analysis (0)]
14.  Ziegler D, Schadewaldt P, Pour Mirza A, Piolot R, Schommartz B, Reinhardt M, Vosberg H, Brösicke H, Gries FA. [13C]octanoic acid breath test for non-invasive assessment of gastric emptying in diabetic patients: validation and relationship to gastric symptoms and cardiovascular autonomic function. Diabetologia. 1996;39:823-830.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 106]  [Cited by in F6Publishing: 101]  [Article Influence: 3.6]  [Reference Citation Analysis (1)]
15.  Chey WD, Shapiro B, Zawadski A, Goodman K. Gastric emptying characteristics of a novel (13)C-octanoate-labeled muffin meal. J Clin Gastroenterol. 2001;32:394-399.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 23]  [Cited by in F6Publishing: 23]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
16.  Choi MG, Camilleri M, Burton DD, Zinsmeister AR, Forstrom LA, Nair KS. [13C]octanoic acid breath test for gastric emptying of solids: accuracy, reproducibility, and comparison with scintigraphy. Gastroenterology. 1997;112:1155-1162.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 145]  [Cited by in F6Publishing: 149]  [Article Influence: 5.5]  [Reference Citation Analysis (0)]
17.  Choi MG, Camilleri M, Burton DD, Zinsmeister AR, Forstrom LA, Nair KS. Reproducibility and simplification of 13C-octanoic acid breath test for gastric emptying of solids. Am J Gastroenterol. 1998;93:92-98.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 92]  [Cited by in F6Publishing: 94]  [Article Influence: 3.6]  [Reference Citation Analysis (0)]
18.  Delbende B, Perri F, Couturier O, Leodolter A, Mauger P, Bridgi B, Bizais Y, des Varannes SB, Andriulli A, Galmiche JP. 13C-octanoic acid breath test for gastric emptying measurement. Eur J Gastroenterol Hepatol. 2000;12:85-91.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 64]  [Cited by in F6Publishing: 62]  [Article Influence: 2.6]  [Reference Citation Analysis (0)]
19.  Haycock GB, Schwartz GJ, Wisotsky DH. Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults. J Pediatr. 1978;93:62-66.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 1186]  [Cited by in F6Publishing: 1165]  [Article Influence: 25.3]  [Reference Citation Analysis (0)]
20.  Statistica (data analysis software system), version 6 0. Tulsa, OK, USA: StatSoft Inc 2001; .  [PubMed]  [DOI]  [Cited in This Article: ]
21.  Maes BD, Ghoos YF, Geypens BJ, Hiele MI, Rutgeerts PJ. Relation between gastric emptying rate and energy intake in children compared with adults. Gut. 1995;36:183-188.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 61]  [Cited by in F6Publishing: 64]  [Article Influence: 2.2]  [Reference Citation Analysis (0)]
22.  Loo FD, Palmer DW, Soergel KH, Kalbfleisch JH, Wood CM. Gastric emptying in patients with diabetes mellitus. Gastroenterology. 1984;86:485-494.  [PubMed]  [DOI]  [Cited in This Article: ]
23.  Jonderko K. Short- and long-term reproducibility of radioisotopic examination of gastric emptying. Int J Rad Appl Instrum B. 1990;17:297-301.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 2]  [Cited by in F6Publishing: 3]  [Article Influence: 0.1]  [Reference Citation Analysis (0)]
24.  Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 32742]  [Cited by in F6Publishing: 31744]  [Article Influence: 835.4]  [Reference Citation Analysis (2)]
25.  Brennan P, Silman A. Statistical methods for assessing observer variability in clinical measures. BMJ. 1992;304:1491-1494.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 679]  [Cited by in F6Publishing: 712]  [Article Influence: 22.3]  [Reference Citation Analysis (2)]
26.  Armitage P Metody statystyczne w badaniach medycznych. Warszawa: PZWL 1978; Statistical Methods in Medical Research. 3rd ed. Oxford London Edinburgh Melbourne: Blackwell Sci Pub, 1971.  [PubMed]  [DOI]  [Cited in This Article: ]
27.  Schoeller DA, Schneider JF, Solomons NW, Watkins JB, Klein PD. Clinical diagnosis with the stable isotope 13C in CO2 breath tests: methodology and fundamental considerations. J Lab Clin Med. 1977;90:412-421.  [PubMed]  [DOI]  [Cited in This Article: ]
28.  Jonderko K, Kasicka-Jonderko A, Blonska-Fajfrowska B. The reproducibility of 13CO2 measurement. Aliment Pharmacol Ther. 2004;19:142-144.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 4]  [Cited by in F6Publishing: 3]  [Article Influence: 0.2]  [Reference Citation Analysis (0)]
29.  Maes BD, Hiele MI, Geypens BJ, Rutgeerts PJ, Ghoos YF, Vantrappen G. Pharmacological modulation of gastric emptying rate of solids as measured by the carbon labelled octanoic acid breath test: influence of erythromycin and propantheline. Gut. 1994;35:333-337.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 52]  [Cited by in F6Publishing: 52]  [Article Influence: 1.7]  [Reference Citation Analysis (0)]
30.  Minderhoud IM, Mundt MW, Roelofs JM, Samsom M. Gastric emptying of a solid meal starts during meal ingestion: combined study using 13C-octanoic acid breath test and Doppler ultrasonography. Absence of a lag phase in 13C-octanoic acid breath test. Digestion. 2004;70:55-60.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 22]  [Cited by in F6Publishing: 19]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
31.  Pera P, Bucca C, Borro P, Bernocco C, De LA, Carossa S. Influence of mastication on gastric emptying. J Dent Res. 2002;81:179-181.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 21]  [Cited by in F6Publishing: 21]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
32.  Rasmussen L, Øster-Jørgensen E, Qvist N, Hovendal CP, Pedersen SA. Gastric emptying in normal subjects: reproducibility and relationship to characteristics of the migrating motor complex. J Gastrointest Mot. 1993;5:233-238.  [PubMed]  [DOI]  [Cited in This Article: ]
33.  Roland J, Dobbeleir A, Vandevivere J, Ham HR. Evaluation of reproducibility of solid-phase gastric emptying in healthy subjects. Eur J Nucl Med. 1990;17:130-133.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 10]  [Cited by in F6Publishing: 9]  [Article Influence: 0.3]  [Reference Citation Analysis (0)]