Ref. | Number of procedures | Technique | Key outcomes |
Beller et al[29], 2007 | 33 open liver resections | Stereotactic optical navigation system, combined with a virtual 3D model and ultrasound, dissection device tracked and navigated on ultrasound image | Navigation successful in 32/33 cases, difference between projected and actual vascular dissection lever 6mm, R0 resection in 30 cases |
Peterhans et al[10], 2011 | 9 open liver resections | Stereotactic navigation system, combined with a virtual 3D model and ultrasound, landmark acquisition on the liver surface, dissection device tracked and navigated on the virtual 3D model | Navigation successful in all cases, median accuracy 6.3 mm |
Banz et al[32], 2016 | 65 open liver resections | Stereotactic optical navigation system, combined with a virtual 3D model and ultrasound, dissection device tracked and navigated on the virtual 3D model, landmark acquisition with ultrasound possible | Combination of 3 d navigated resection and thermal ablation in 16 patients, accuracy optimized to 4.5 ± 3.6 mm |
Tinguely et al[35], 2017 | 54 laparoscopic image guided microwave ablation | Laparoscopic stereotactic navigation system, combined with a virtual 3D model, landmark acquisition on the liver surface, ablation device tracked and navigated on the virtual 3D model, standard 2D laparoscopic display | Registration time 4:38 min, accuracy 8.1 ± 2.8 mm, early local recurrence rate 32% |
Aoki et al[37], 2021 | 27 laparoscopic liver lesions | virtual real-time CT-guided volume navigation, electromagnetic tracking of the surgical instruments displayedon the preoperatively acquired CT images | Registration time < 2 min, registration error 12 mm, histologic resection margin 9 mm |
Prevost et al[26], 2020 | 10 laparoscopic liver resections | stereotactic augmented reality navigation, virtual 3D liver model superimposed on the real liver with a 3D laparoscopic system, instruments tracked | Registration time 8:50 min, registration error 9.2 mm, facilitates to find disappeared liver lesions |