Copyright
©The Author(s) 2015.
World J Meta-Anal. Dec 26, 2015; 3(6): 232-253
Published online Dec 26, 2015. doi: 10.13105/wjma.v3.i6.232
Published online Dec 26, 2015. doi: 10.13105/wjma.v3.i6.232
Table 3 Safety of self-expandable metal stent placement
Category and subgroups | Studies | Event rate (%) | 95%CI | P value | I2 value | |
Overall complication rate | 25 | 23.1 | 18.5-28.6 | 0.000 | 81.86 | |
Indication | Palliation | 10 | 27.3 | 18.7-38 | 0.000 | 80.60 |
BTS | 3 | 13.8 | 8.3-22.2 | 0.371 | 0.00 | |
Center | Single Center | 20 | 25.2 | 20.1-31.1 | 0.000 | 78.20 |
Multicenter | 5 | 16.2 | 10.8-23.6 | 0.058 | 56.11 | |
Design | Prospective | 8 | 20.6 | 13.6-30.0 | 0.000 | 82.64 |
Retrospective | 16 | 25.0 | 19.1-31.8 | 0.000 | 79.08 | |
Center | Asia | 9 | 25.1 | 16.1-36.9 | 0.000 | 84.93 |
Europe | 12 | 21.3 | 15.1-29.1 | 0.000 | 81.28 | |
North America | 3 | 28.0 | 21.9-35 | 1.000 | 0.00 | |
Obstruction rate | 25 | 8.3 | 6.0-11.4 | 0.000 | 68.79 | |
Indication | Palliation | 10 | 9.5 | 5.4-16.4 | 0.001 | 69.55 |
BTS | 3 | 1.9 | 0.5-7.1 | 0.959 | 0.00 | |
Center | Single Center | 20 | 8.7 | 6.2-12.1 | 0.000 | 63.23 |
Multicenter | 5 | 3.1 | 1.8-5.4 | 0.000 | 80.21 | |
Design | Prospective | 8 | 8.2 | 4.9-13.5 | 0.001 | 70.11 |
Retrospective | 16 | 8.7 | 5.7-13.0 | 0.000 | 67.79 | |
Region | Asia | 9 | 9.8 | 5.3-17.2 | 0.000 | 74.58 |
Europe | 12 | 7.7 | 4.8-12.1 | 0.001 | 63.77 | |
North America | 3 | 7.5 | 5.1-10.9 | 0.961 | 0.00 | |
Migration rate | 29 | 7.6 | 5.7-10.0 | 0.000 | 55.48 | |
Indication | Palliation | 10 | 10.2 | 7.1-14.5 | 0.150 | 32.56 |
BTS | 7 | 4.1 | 2.0-8.1 | 0.687 | 0.00 | |
Center | Single Center | 23 | 9.7 | 7.7-12.1 | 0.061 | 33.51 |
Multicenter | 6 | 2.1 | 1.2-3.6 | 0.977 | 0.00 | |
Design | Prospective | 10 | 5.5 | 2.6-11.3 | 0.000 | 79.25 |
Retrospective | 18 | 9.0 | 7.3-11.1 | 0.389 | 5.55 | |
Center | Asia | 12 | 10.2 | 7.9-13.0 | 0.434 | 0.95 |
Europe | 13 | 5.4 | 2.9-10.0 | 0.000 | 75.80 | |
North America | 3 | 7.8 | 5.4-11.3 | 0.972 | 0.00 | |
Perforation rate | 29 | 4.9 | 3.6-6.6 | 0.037 | 34.39 | |
Indication | Palliation | 10 | 5.4 | 2.9-9.8 | 0.054 | 46.00 |
BTS | 7 | 4.0 | 1.9-8.2 | 0.646 | 0.00 | |
Center | Single Center | 23 | 5.1 | 3.6-7.2 | 0.042 | 36.56 |
Multicenter | 6 | 4.0 | 2.6-4.7 | 0.586 | 0.00 | |
Design | Prospective | 10 | 3.1 | 2.1-4.7 | 0.722 | 0.00 |
Retrospective | 18 | 6.2 | 4.4-8.6 | 0.117 | 29.48 | |
Center | Asia | 12 | 3.6 | 1.8-7.0 | 0.024 | 50.02 |
Europe | 13 | 4.4 | 3.2-6.0 | 0.472 | 0.00 | |
North America | 3 | 8.4 | 5.8-11.9 | 0.463 | 0.00 |
- Citation: Thosani N, Banerjee S, Khanijow V, Rao B, Priyanka P, Ertan A, Guha S. Role of self-expanding metal stents in patients with malignant colorectal obstruction: A systematic review and meta-analysis. World J Meta-Anal 2015; 3(6): 232-253
- URL: https://www.wjgnet.com/2308-3840/full/v3/i6/232.htm
- DOI: https://dx.doi.org/10.13105/wjma.v3.i6.232