Part | Modulus of elasticity in MPa | Poisson’s ratio |
Pubic cartilage | 5.00 | 0.45 |
Interosseous sacroiliac ligament | 5610.00 | 0.20 |
Sacrum | 6140.00 | 0.30 |
Sacrospinous ligament | 12.60 | 0.20 |
Sacrotuberous ligament | 46.48 | 0.300 |
Sacroiliac joint cartilage | 54.00 | 0.40 |
Iliac cancellous bone | 132.00 | 0.20 |
Femur | 18200.00 | 0.38 |
Posterior sacroiliac ligament | 133.00 | 0.20 |
Acetabular cartilage | 12.00 | 0.42 |
Iliac cortical bone | 17000.00 | 0.30 |
Anterior sacroiliac ligament | 208.00 | 0.20 |