Copyright
©The Author(s) 2019.
World J Clin Cases. Dec 6, 2019; 7(23): 3934-3944
Published online Dec 6, 2019. doi: 10.12998/wjcc.v7.i23.3934
Published online Dec 6, 2019. doi: 10.12998/wjcc.v7.i23.3934
Table 3 Analysis of receiver operating characteristic for diagnosis of septic acute kidney injury by potential indicators
AUC | 95%CI | Cut-off point | Sensitivity | Specificity | |
SIRS | 0.555a | 0.446 - 0.660 | 2.69 | 27.03% | 92.45% |
Lac | 0.674a | 0.567 - 0.769 | 2.67 mmol/L | 62.16% | 64.15% |
Scr | 0.825a | 0.730 - 0.897 | 129.98 μmol/L | 56.76% | 100.00% |
BUN | 0.658a | 0.551 - 0.755 | 2.84 mmol/L | 37.74% | 91.89% |
PI | 0.912 | 0.833 - 0.961 | 15.93 dB | 100.00% | 75.47% |
RT | 0.758a | 0.656 - 0.842 | 8.1 s | 83.78% | 58.49% |
WIS | 0.928 | 0.853 - 0.972 | 1.48 dB/s | 100.00% | 71.70% |
Combination | 0.943 | 0.873 - 0.981 | 0.48 | 94.59% | 81.13% |
- Citation: Wang XY, Pang YP, Jiang T, Wang S, Li JT, Shi BM, Yu C. Value of early diagnosis of sepsis complicated with acute kidney injury by renal contrast-enhanced ultrasound. World J Clin Cases 2019; 7(23): 3934-3944
- URL: https://www.wjgnet.com/2307-8960/full/v7/i23/3934.htm
- DOI: https://dx.doi.org/10.12998/wjcc.v7.i23.3934