Randomized Clinical Trial
Copyright ©The Author(s) 2024.
World J Clin Cases. Jul 6, 2024; 12(19): 3882-3889
Published online Jul 6, 2024. doi: 10.12998/wjcc.v12.i19.3882
Table 3 Comparison of objective visual quality between the two groups before and after operation
Index
Observation group (70 eyes)
Control group (64 eyes)
t
P value
OSI
Preoperative1.89 ± 0.331.92 ± 0.31-0.5410.589
6 months after operation0.62 ± 0.21a1.32 ± 0.26a-17.2090.000
MTF cut off (c/deg)
Preoperative8.28 ± 2.218.60 ± 2.03-0.8700.386
6 months after operation22.32 ± 5.12a14.44 ± 3.82a10.0220.000
100% OV
Preoperative0.26 ± 0.080.28 ± 0.09-1.3620.176
6 months after operation0.88 ± 0.20a0.54 ± 0.18a10.3080.000
20% OV
Preoperative0.28 ± 0.090.29 ± 0.07-0.7130.477
6 months after operation0.78 ± 0.10a0.40 ± 0.11a20.9470.000
9% OV
Preoperative0.09 ± 0.030.10 ± 0.03-1.9270.056
6 months after operation0.36 ± 0.06a0.18 ± 0.04a20.2350.000