Copyright
©The Author(s) 2024.
World J Clin Cases. Jun 26, 2024; 12(18): 3378-3384
Published online Jun 26, 2024. doi: 10.12998/wjcc.v12.i18.3378
Published online Jun 26, 2024. doi: 10.12998/wjcc.v12.i18.3378
Table 4 Comparison of pregnancy complications and pregnancy outcomes between the two groups
Group | n | Amniotic fluid contamination | Oligohydramnios | Preeclampsia | Premature rupture of membranes | Macrosomia | Fetal distress |
Insulin pump group | 210 | 8 | 6 | 6 | 2 | 2 | 2 |
Insulin subcutaneous injection group | 210 | 14 | 10 | 8 | 26 | 4 | 16 |
Statistical value | - | 1.727 | 1.04 | 0.296 | 22.041 | 0.676 | 11.376 |
P value | - | 0.189 | 0.308 | 0.586 | < 0.001 | 0.411 | 0.001 |
- Citation: Wang Y, Gao W, Wang XJ. Comparative effects of insulin pump and injection on gestational diabetes mellitus pregnancy outcomes and serum biomarkers. World J Clin Cases 2024; 12(18): 3378-3384
- URL: https://www.wjgnet.com/2307-8960/full/v12/i18/3378.htm
- DOI: https://dx.doi.org/10.12998/wjcc.v12.i18.3378